Z-Wave Plus – UseManuals https://usemanuals.com Owner's manuals for all sorts of products Wed, 16 Aug 2023 07:52:12 +0000 en-US hourly 1 https://wordpress.org/?v=6.7.2 https://usemanuals.com/wp-content/uploads/2025/02/favicon-32x32-2.png Z-Wave Plus – UseManuals https://usemanuals.com 32 32 Z-WAVE PLUS Minoston MPZ Mini Smart Plug Manual https://usemanuals.com/z-wave-plus/minoston-plug/ Mon, 24 Jul 2023 16:56:28 +0000 https://usemanuals.com/?p=174124 Read More...

]]>

Z-WAVE PLUS Minoston MPZ Mini Smart Plug

Federal Communications Commission (FCC) Statement
FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. This device must accept any interference received, including interference that may cause undesired operation.

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna.Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which is connected. Consult the dealer or an experienced radio/TV technician for help. This equipment should be installed and operated with minimum distance 20cm between the radiator and you

IC Caution:
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions:

  1. This device may not cause interference, and
  2. This device must accept any interference, including interference that may cause undesired operation of the device.

WARRANTY

EVALOGIK Products warrants this product to be free from manufacturing defects for a period of two years from the original date of consumer purchase. This warranty is limited to the repair or replacement of this product only and does not extend to consequential or incidental damage to other products that may be used with this product.

This warranty is in lieu of all other warranties, expressed or implied. Some states do not allow limitations on how long an implied warranty lasts or permit the exclusion or limitation
of incidental or consequential damage, so the above limitations may not apply to you.

This warranty gives you specific rights, and you may also have other rights which vary from state to state. if the unit should prove defective within the warranty period.

SPECIFICATIONS

  • Model: MP21Z
  • Power: 120 VAC, 60 Hz.
  • Signal (Frequency): 908.42 MHZ.
  • Maximum load for outlet 15A, 1200W Resistive
  • Maximum load for the Z-Wave controlled outlet: 600W Incandescent, ½ HP Motor or 1200W Resistive
  • Range: Up to 100 feet line of sight between the Wireless Controller and the closest Z-Wave receiver module.
  • Operating Temperature Range: 32-104° F (0-40° C) For Outdoor use

Specifications subject to change without notice due to continuing product improvement
Website: www.NIE-TECH.com

WARNING

RISK OF FIRE
RISK OF ELECTRICAL SHOCK
RISK OF BURNS
CONTROLLING APPLIANCES:
EXERCISE EXTREME CAUTION WHEN USING Z-Wave DEVICES TO CONTROL APPLIANCES. OPERATION OF THE Z-Wave DEVICE MAY BE IN A DIFFERENT ROOM THAN THE CONTROLLED APPLIANCE, ALSO AN UNINTENTIONAL ACTIVATION MAY OCCUR IF THE WRONG BUTTON ON THE REMOTE IS PRESSED. Z-Wave DEVICES MAY AUTOMATICALLY BE POWERED ON DUE TO TIMED EVENT PROGRAMMING.
DEPENDING UPON THE APPLIANCE, THESE UNATTENDED OR UNINTENTIONAL OPERATIONS COULD POSSIBLY RESULT IN A HAZARDOUS CONDITION. FOR THESE REASONS, WE RECOMMEND DO NOT RETURN THIS PRODUCT TO THE STORE THE FOLLOWING:

  • DO NOT USE Z-Wave DEVICES TO CONTROL ELECTRIC
  • HEATERS OR ANY OTHER APPLIANCES WHICH MAY PRESENT
  • A HAZARDOUS CONDITION DUE TO UNATTENDED OR
  • UNINTENTIONAL OR AUTOMATIC POWER ON CONTROL.

Introduction:

The MP21Z is a Z-Wave enabled device and is fully compatible with any Z-Wave Plus™ enabled network.
Each module is designed to act as a repeater,which will re-transmit a radio frequency (RF) signal by routing the around obstacles and radio dead spots to ensure that the signal is received at its intended destination.
MP21Z is a security enabled Z-Wave Plus device. A security Enabled Z-Wave Plus Controller must be used in order to fully utilize the

Key Features:

  • Remote ON/OFF control via the Z-Wave controller
  • Manual ON/OFF control with the front panel push button
  • Support Association Group and Auto Report switch status
  • Over temperature protection
  • Support firmware upgrades via Over-the-air (need Gateways support)

Product Overview:

  1. AC plug
  2. Z-Wave controlled outlet
  3. ON/OFF/PROG Push button/ Status LED

Z-Wave Remote Control

ADD or Remove the MP21Z from the existing Z-Wave home control network with your primary controller.

  • Refer to your primary controller instructions to process the inclusion / exclusion setup procedure.
  • When prompted by your primary controller, click the PROG button five times in one second.

Include MP21Z to/from a Z-Wave Gateway with supporting Security. The MP21Z can support the Primary Controller that implemented the se

Notice: Including a node ID allocated by Z-WaveTM Controller means “Add” or “Inclusion”. Excluding a node ID allocated by
Z-WaveTM Controller means “Remove” or “Exclusion”.

Z-Wave protocol Command Class Node Info
  • COMMAND_CLASS_ZWAVEPLUS_INFO,
  • COMMAND_CLASS_VERSION,
  • COMMAND_CLASS_MANUFACTURER_SPECIFIC,
  • COMMAND_CLASS_DEVICE_RESET_LOCALLY,
  • COMMAND_CLASS_ASSOCIATION,
  • COMMAND_CLASS_ASSOCIATION_GRP_INFO,
  • COMMAND_CLASS_POWERLEVEL,
  • COMMAND_CLASS_SWITCH_BINARY,
  • COMMAND_CLASS_CONFIGURATION,
  • COMMAND_CLASS_NOTIFICATION_V8,
  • COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V2,
  • COMMAND_CLASS_TRANSPORT_SERVICE_V2,
  • COMMAND_CLASS_SECURITY,
  • COMMAND_CLASS_SECURITY_2,
  • COMMAND_CLASS_SUPERVISION
  • COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4

The Below listed Command Class are all supported the Security S2

  • COMMAND_CLASS_VERSION,
  • COMMAND_CLASS_MANUFACTURER_SPECIFIC, COMMAND_CLASS_DEVICE_RESET_LOCALLY, COMMAND_CLASS_ASSOCIATION,
  • COMMAND_CLASS_ASSOCIATION_GRP_INFO, COMMAND_CLASS_POWERLEVEL,
  • COMMAND_CLASS_SWITCH_BINARY,
  • COMMAND_CLASS_CONFIGURATION,
  • COMMAND_CLASS_NOTIFICATION_V8,
  • COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V2, COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4
Z-Wave Configuration Parameters

You may use the below configuration parameters to change settings of the corresponding functionality.

  1. Status LED Configuration
    • Paramter No: 1(0x01)
    • Size:1 Byte
    • Value: 00(default)
    • outlet on,led on.
      • Value: 01
      • Value: 02
    • outlet on, led off.
    • led off, led no work.
  2. Count Down Configuration(The countdown time, the socket closed)
    • Paramter No: 2(0x02) Size:2 Byte Value: 00 00(default) – no timer.
    • Value Scope :0—-36000S(Countdown time can be set up for 10 hours)

Support for Association Groups

MP21Z supports 2 association groups. A maximum of 5 node ID’s (nonmulti-channel devices) can be assigned to these association group Association group_1: Z-Wave Plus Lifeline Maximum 5 node

Association group_1 is default to associate with the primary controller (Gateway/Hub/Controller) for MP21Z Status change report

  1. MP21Z will trigger AUTO report function if the Switch status had been changed.
  2. Device Reset Locally Notification(Only report when the MP21Z Switch Module has been triggered the RESET TO DEFAULT)

Association group_2: basic set command
When the output of the MP21Z socket is changed, On (0xFF) or Off (0x00). The MP21Z will automatically send out a related basic Once (t 0cxoFmF) manord. Off (0x00) to its associated group.

Support for Over Temperature Protection

MP21Z support Over temperature protection,When the temperature is greater than 105 degrees Celsius, the Heat Alarm signal is sent ou Notification Type : Heat Alarm 0x04 .

Event :Overheat detected 0x02
Restoring Factory Defaults
All Configuration Parameters values and Association information will be restored to factory default settings and excluded from the n When the device is removed from the host, it is returned to the factory settings

MANUAL RESET

  • Power off MP21Z
  • keep holding the PROG button
  • Power on,Press and keep holding the PROG button for no less than 10 seconds.

Remark: All the setting and data will be permanently deleted.
Please use this procedure only when the network primary controller is missing or otherwise inoperable.

]]>
Z-WAVE PLUS PAU Range Extender Repeater Manual https://usemanuals.com/z-wave-plus/pau-repeater/ Mon, 24 Jul 2023 16:57:59 +0000 https://usemanuals.com/?p=174133 Read More...

]]>
Z-WAVE PLUS PAU Range Extender Repeater User Guide

Introduction

The Range Extender Repeater is a Z-Wave™ enabled device (interoperable, two way RF mesh networking technology) and is fully compatible with any Z Wave™ enabled network. Every main powered Z-Wave enabled device acts as a signal repeater and multiple devices result in more possible transmission routes which helps eliminate “RF dead-sports” Z-Wave™ enabled devices displaying the ZWave™ logo can also be used with it regardless of the manufacturer, and ours can also be used in other manufacturer’s Z-Wave™ enabled networks.
The product supports Over The Air(OTA) feature for the products firmware upgrade.

Adding to Z-Wave™ Network

This product can be operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.

The table below lists an operation summary of basic Z-Wave functions. Please refer to the instructions for your Z-WaveTM Certificated Primary Controller to access the Setup function, and to Add/Remove/associate devices

Function Description Annotation
No node ID The Z-Wave Controller does not allocate a node ID to the Switch. LED 2-second on, 2-second off (Blue LED)
Add (Inclusion) Put your Z-Wave controller into inclusion mode by following the instructions provided by the controller manufacturer
Pressing Include button of PAU05 three times within 2 seconds will enter inclusion mode
Remove (Exclusion) Put your Z-Wave controller into exclusion mode by following the instructions provided by the controller manufacturer
Pressing Include button of PAU05 three times within 2 seconds will enter exclusion mode.
Node ID has been excluded. LED 2-second on, 2-second off (Blue LED)
SmartStart
  1. Product has a DSK string, you can key in first five digit to increment smart start process, or you can scan QR code.
  2. SmartStart enabled products can be added into a Z-Wave network by scanning the Z-Wave QR Code present on the product with a controller providing SmartStart inclusion. No further action is required and the SmartStart product will be added automatically within 10 minutes of being switched on in the network vicinity.
    • notice1: The
Association The PAU05 is an always listening Z-Wave device, so associations may be added or removed by a controller at any time. Or If your controller requires to have the PAU05 send a ‘node information frame’ or NIF for associations, then pressing the On/Off button three times within 2 seconds will cause the PAU05 to send its NIF.

Note: The device support 1 groups. The group 1 is for receiving the report message etc. A group one support 5 nodes maximum.

  • dding a node ID allocated by Z-Wave Controller means inclusion. Removing a node ID allocated by Z-Wave Controller means exclusion.
  • Failed or success in including/excluding the node ID can be viewed from the Z-Wave Controller.

LED Indication

To distinguish what mode the switch is in, view from the blue LED for identification.

State Type LED Indication
Normal When the power is turned on, its LED is always on. (Blue LED)
No node ID Under normal operation, when the Switch has not been allocated a node ID, the blue LED flashes on and off alternately at 2-second intervals. By pressing On/Off button, it will stop flashing temporarily.
Learning When PAU05 is in learning mode, blue LED flashes on and off alternately and repeatedly at 2 second intervals.

Programming

  1. Network health
    Press the button once to enter the network health test. According to the test results, the LED light will flash three times. LED color meaning is as follows:

    LED color Description
    Green Network health is good.
    Yellow Network health is acceptable but latency can be observed occasionally.
    Red Network health is insufficient because frames are dropped.
  2. Z-Wave’s Configuration
    Configuration Parameter Function Size

    (Byte)

    Value Unit Default Description
    1 LED mode (Blue LED) 1 0-1 0
    • 0: LED on
    • 1: LED off
  3. LED mode (Blue LED):
    Whenever the AC power return from lost, PAU05 will restore the LED mode which could be LED off、LED on. The default setting is LED on.
  4. Firmware update over the air (OTA)
    PAU05 is based on 500 series SoC and supports Firmware Update Command Class, it can receives the updated firmware image sent by controller via the Zwave RF media. It is a helpful and convenient way to improve some function if needed.

Command Classes

The Repeater supports Command Classes including…

Command Class Version Required Security Class
Z-Wave Plus Info 2 None
Version 3 Highest granted Security Class
Manufacturer Specific 2 Highest granted Security Class
Security 2 1 None
Device Reset Locally 1 Highest granted Security Class
Association 2 Highest granted Security Class
Association Group Information 1 Highest granted Security Class
Powerlevel 1 Highest granted Security Class
Configuration 1 Highest granted Security Class
Firmware Update Meta Data 4 Highest granted Security Class
Supervision 1 None
Transport Service 2 None

Overview

Specifications

Operating Voltage DC5V (USB Type A)
Operating Temperature -10°C ~ 55°C (85% humidity)
Storage Temperature -20 C ~ 60°C
RF Range (distance) Minimum 40M in door and 100M in outdoor, line of sight
Frequency Range
  • 868.40MHz; 869.85MHz (EU)
  • 908.40MHz; 916.00MHz (US)
  • 916.00 MHz (IL), (Israel), (PAU05-IL) 922~927MHz (Japan)
  • 920~924MHz (Taiwan; Korea)
  • 865.20 MHz (IN),
  • 869.00 MHz (RU),
  • 921.40 MHz, 919.80 MHz (ANZ),
RF Maximum Power (peak) +5dBm (peak)
RF Maximum Power -10dBm (Average)
(Average)
RF Modulation Type FSK (Frequency-Shift Keying)

** Specifications are subject to change and improvement without notice.

FCC ID: RHHPAU05

FCC Interference Statement

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. This device must accept any interference received, including interference that may cause undesired operation.

FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.

This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.

Disposal


This marking indicates that this product should not be disposed with other household wastes throughout the EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return your used device, please use the return and collection systems or contact the retailer where the product was purchased. They can take this product for environmental safe recycling.

www.philio-tech.com
Philio Technology Corporation
8F., No.653-2, Zhongzheng Rd., Xinzhuang Dist., New Taipei City 24257, Taiwan

Warning

Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities. Contact your local government for information regarding the collection systems available. If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the groundwater and get into the food chain, damaging your health and well-being.

When replacing old appliances with new once, the retailer is legally obligated to take back your old appliance for disposal at least for free of charge.

]]>
Z-Wave PLUS EVA LOGIK Smart Dimmer Switch S2 Manual https://usemanuals.com/z-wave-plus/s2-switch/ Wed, 16 Aug 2023 07:52:12 +0000 https://usemanuals.com/?p=200963 Read More...

]]>

Z-Wave PLUS EVA LOGIK Smart Dimmer Switch

Federal Communications Commission (FCC) Statement
FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may caus harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body

IC Caution:
This device complies with Industry Canada licence-exempt RSS standard(s).
Operation is subject to the following two conditions:

  1. this device may not cause interference, and
  2. this device must accept any interference, including interference that may cause undesired operation of the device.

DECLARATION DE CONFORMITE D’INDUSTRIE CANADA

WARRANTY

Evalogik Products warrants this product to be free from manufacturing defects for a period of two years from the original date of consumer purchase. This warranty is limited to the repair or replacement of this product only and does not extend to consequential or incidental damage to other products that may be used with this product.

This warranty is in lieu of all other warranties, expressed or implied. Some states do not allow limitations on how long an implied warranty lasts or permit the exclusion or limitation of incidental or consequential damage, so the above limitations may not apply to you.

This warranty gives you specific rights, and you may also have other rights which vary from state to state. if the unit should prove defective within the warranty period.

SPECIFICATIONS

Model: ZW31
Power: 120 VAC, 60 Hz.
Signal (Frequency): 908.42 MHZ.
Maximum Loads: 500W, 2-gang 400W or 3-gang 300W incandescent, 100W CFL/LED
Range: Up to 100 feet line of sight between the Wireless Controller and the closest Z-Wave receiver module.
Operating Temperature Range: 32-104° F (0-40° C)
For Ourdoor use
Specifications subject to change without notice due to continuing product improvement

WARNING

  • RISK OF FIRE
  • RISK OF ELECTRICAL SHOCK
  • RISK OF BURNS
  • CONTROLLING APPLIANCES:
    EXERCISE EXTREME CAUTION WHEN USING Z-Wave DEVICES TO CONTROL APPLIANCES. OPERATION OF THE Z-Wave DEVICE MAY BE IN A DIFFERENT
    ROOM THAN THE CONTROLLED APPLIANCE, ALSO ANUNINTENTIONAL ACTIVATION MAY OCCUR IF THE WRONG BUTTON ON THE REMOTE IS PRESSED. Z-Wave DEVICES MAY AUTOMATICALLY BE POWERED ON DUE TO TIMED EVENT PROGRAMMING. DEPENDING UPON THE APPLIANCE, THESE UNATTENDED OR UNINTENTIONAL OPERATIONS COULD POSSIBLY RESULT IN A HAZARDOUS CONDITION. FOR THESE REASONS, WE RECOMMEND DO NOT RETURN THIS PRODUCT TO THE STORE
    THE FOLLOWING:
  • DO NOT USE Z-Wave DEVICES TO CONTROL ELECTRIC
  • HEATERS OR ANY OTHER APPLIANCES WHICH MAY PRESENT
  • A HAZARDOUS CONDITION DUE TO UNATTENDED OR UNINTENTIONAL OR AUTOMATIC POWER ON CONTROL.

Introduction:

This product can be operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers.
All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network. Each module is designed to act as a repeater, which will re-transmit a radio frequency (RF) signal by routing the signal around obstacles and radio dead spots to ensure that the signal is received at its intended destination.
ZW31 is a security enabled Z-Wave plus device. A security Enabled Z-Wave Plus Controller must be used in order to fully utilize the product. The Device Type of the ZW31 is Dimmer power switch.
The Role Type of the ZW31 is Always On Slave Role Type

Key Features:

  • Remote ON/OFF control via the Z-Wave controller
  • Manual ON/OFF control with the front panel push button
  • Support Association Group and Auto Report switch status
  • Support firmware upgrades via Over-the-air (need Gateways support)
  • Support Scenes

Product Overview:

  • A. Up Push button
  • B. Down Push button
  • C. Load (Black)
  • D. Lin (Black) – Line in
  • E. Nin (White) – Nutral in
  • F. 3-way (RED)

ZW31 Installation Wiring Diagram

Key function description

Function 1: Press the up or down button to turn the output ON or OFF
Function 2: Hold Dimmer Up or Dimmer Down
Function 3: Press the up or down button three times quickly to ADD and REMOVE
Function 4: Press the up or down button six times quickly to change Status LED Configuration
Function 5: When switch is off and quickly press UPPER paddle 2 times, switch turns on to 100% brightness
Function 6: Press click Z-Wave button 3 times quickly, and hold for at least 10 seconds at the third time to restore the device to the factory
(Node: Please use this procedure only when the network primary controller is missing or otherwise inoperable.)
Function 7: Tap A(1x/2x/3x/4x/5x/Hold/Release) Activate the scene.
Function 8: Tap B(1x/2x/3x/4x/5x/Hold/Release) Activate the scene.

Led Indicate Function
  1. Flash two times
    When configuration parameter succeed LED flash two times
  2. quickly flash
    When inclusion or exclusion or reset, LED will quickly flash till operate complete

Z-Wave Remote Control
ADD or Remove the ZW31 from the existing Z-Wave home control network with your primary controller.

  • Refer to your primary controller instructions to process the inclusion / exclusion setup procedure.
  • When prompted by your primary controller, click the Up or Down button three times in one second.

Include ZW31 to/from a Z-Wave Gateway with supporting Security. The ZW31 can support the Primary Controller that implemented the security S2.
Notice: Including a node ID allocated by Z-WaveTM Controller means “Add” or “Inclusion”. Excluding a node ID allocated by Z-WaveTM Controller means “Remove” or “Exclusion”.

Z-Wave protocol Command Class Node Info

COMMAND_CLASS_ZWAVEPLUS_INFO,
COMMAND_CLASS_SWITCH_MULTILEVEL,
COMMAND_CLASS_ASSOCIATION,
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION,
COMMAND_CLASS_ASSOCIATION_GRP_INFO,
COMMAND_CLASS_TRANSPORT_SERVICE,
COMMAND_CLASS_VERSION,
COMMAND_CLASS_MANUFACTURER_SPECIFIC,
COMMAND_CLASS_CONFIGURATION,
COMMAND_CLASS_CENTRAL_SCENE,
COMMAND_CLASS_SECURITY_2,
COMMAND_CLASS_SUPERVISION
COMMAND_CLASS_FIRMWARE_UPDATE_MD

The Below listed Command Class are all supported the Security S2

COMMAND_CLASS_SWITCH_MULTILEVEL,
COMMAND_CLASS_ASSOCIATION,
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION,
COMMAND_CLASS_ASSOCIATION_GRP_INFO,
COMMAND_CLASS_VERSION,
COMMAND_CLASS_MANUFACTURER_SPECIFIC,
COMMAND_CLASS_DEVICE_RESET_LOCALLY,
COMMAND_CLASS_CENTRAL_SCENE,
COMMAND_CLASS_CONFIGURATION,
COMMAND_CLASS_POWERLEVEL
COMMAND_CLASS_FIRMWARE_UPDATE_MD

Support for Association Groups

ZW31 supports 2 association groups. Group 1 support 1 node ID,Group 2 Support maximum of 5 node ID’s Association group_1:Z-Wave Plus Lifeline

Association group_1 is default to associate with the primary controller (Gateway/Hub/Controller) for ZW31 Status change report, 1. ZW31 will trigger AUTO report function if the Switch status had been changed.

Association group_2:basic set command
When the output of the ZW31 is changed, The ZW31 will automatically send out a related basic set command.

Restoring Factory Defaults

ZW31 is removed from the network and will be restored to the factory setting
All Configuration Parameters values and Association information will be restored to factory default settings and excluded from the network. Remark : All the setting and data will be permanently deleted.
Please use this procedure only when the network primary controller is missing or otherwise inoperable.

]]>