<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>WAND Blue &#8211; UseManuals</title>
	<atom:link href="http://usemanuals.com/wand-blue/feed/" rel="self" type="application/rss+xml" />
	<link>https://usemanuals.com</link>
	<description>Owner&#039;s manuals for all sorts of products</description>
	<lastBuildDate>Sun, 09 Apr 2023 15:48:29 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.7.2</generator>

<image>
	<url>https://usemanuals.com/wp-content/uploads/2025/02/favicon-32x32-2.png</url>
	<title>WAND Blue &#8211; UseManuals</title>
	<link>https://usemanuals.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>ThermoWorks WAND Blue manual</title>
		<link>https://usemanuals.com/wand-blue/thermoworks/</link>
		
		<dc:creator><![CDATA[ItsManual]]></dc:creator>
		<pubDate>Sun, 09 Apr 2023 15:48:29 +0000</pubDate>
				<category><![CDATA[WAND Blue]]></category>
		<guid isPermaLink="false">https://usemanuals.com/?p=66829</guid>

					<description><![CDATA[&#160; ThermoWorks WAND Blue How to Use Power on device. Pair with app. Use ours or integrate into your existing apps. Point at center of forehead 1–2 inches away. Press and hold START for 1 second— a single beep tells you it’s done. WAND Blue is pre-set to forehead mode and to display temperature in Fahrenheit. Three short beeps followed by one long beep while taking a forehead reading means that the temperature exceeded 99.5°F (37.5°C). Please wait 2 seconds between measurements. Functions Power Off Device Device will auto-off after 60 seconds to save battery life. Or, press and hold Power button for about 5 seconds. ‘Off’ will flash before powering off. View Readings With device turned on, press Power button momentarily to see the last reading, which is reading number 1. Each subsequent press of the Power button will show up to 25 readings in order. The reading number will flash before displaying the value. You can also see your saved readings in the app. Mute With device turned on, press and hold Power button for 3 seconds until speaker icon flashes, then release. Repeat steps to unmute. Change to Surface Mode With device turned on, press and hold Power button, then press Start to toggle between modes. Device will automatically return to forehead mode after powered off and back on again. Change from °F to °C Default unit is °F. With device turned off, press and hold Start and the Power button simultaneously for three seconds. Units will change. Cautions Forehead should be clean, dry, and unobstructed before taking readings. WAND Blue is not waterproof. Avoid wet areas and splashes. Do not expose device to temperatures above 100°F (38°C) or below 50°F (10°C). Replace batteries when battery icon flashes. Store device at room temperature where readings will be taken for best results. Avoid drops, bumps, and rough handling that could damage device. Sensor lens area is the most delicate part; keep clean and free from debris. Consult user manual before cleaning lens. The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by ThermoWorks, Inc. is under license. www.thermoworks.com/wand-blue &#124; 801-756-7705 For warranty, service, and technical assistance, please contact ThermoWorks’ Technical Support at (801) 756-7705 or email techsupport@thermoworks.com. [...]<p><a class="btn btn-secondary understrap-read-more-link" href="https://usemanuals.com/wand-blue/thermoworks/">Read More...</a></p>]]></description>
										<content:encoded><![CDATA[<p>&nbsp;</p>
<h3><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/03/logo-309.png" /></h3>
<h4>ThermoWorks WAND Blue</h4>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/03/product-253.png" /></p>
<h4>How to Use</h4>
<ol>
<li>Power on device.</li>
<li>Pair with app. Use ours or integrate into your existing apps.</li>
<li>Point at center of forehead 1–2 inches away.<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/03/image-1-232.png" /></li>
<li>Press and hold START for 1 second— a single beep tells you it’s done.</li>
</ol>
<p>WAND Blue is pre-set to forehead mode and to display temperature in Fahrenheit. Three short beeps followed by one long beep while taking a forehead reading means that the temperature exceeded 99.5°F (37.5°C). Please wait 2 seconds between measurements.</p>
<h4>Functions</h4>
<p><strong>Power Off Device<br />
</strong>Device will auto-off after 60 seconds to save battery life. Or, press and hold Power button for about 5 seconds. ‘Off’ will flash before powering off.</p>
<p><strong>View Readings<br />
</strong>With device turned on, press Power button momentarily to see the last reading, which is reading number 1. Each subsequent press of the Power button will show up to 25 readings in order. The reading number will flash before displaying the value. You can also see your saved readings in the app.</p>
<p><strong>Mute<br />
</strong>With device turned on, press and hold Power button for 3 seconds until speaker icon flashes, then release. Repeat steps to unmute.</p>
<p><strong>Change to Surface Mode<br />
</strong>With device turned on, press and hold Power button, then press Start to toggle between modes. Device will automatically return to forehead mode after powered off and back on again.</p>
<p><strong>Change from °F to °C</strong><br />
Default unit is °F. With device turned off, press and hold Start and the Power button simultaneously for three seconds. Units will change.</p>
<h4>Cautions</h4>
<ul>
<li>Forehead should be clean, dry, and unobstructed before taking readings.</li>
<li>WAND Blue is not waterproof. Avoid wet areas and splashes.</li>
<li>Do not expose device to temperatures above 100°F (38°C) or below 50°F (10°C).</li>
<li>Replace batteries when battery icon flashes.</li>
<li>Store device at room temperature where readings will be taken for best results.</li>
<li>Avoid drops, bumps, and rough handling that could damage device.</li>
<li>Sensor lens area is the most delicate part; keep clean and free from debris.</li>
<li>Consult user manual before cleaning lens.</li>
</ul>
<p>The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by ThermoWorks, Inc. is under license.</p>
<p><a href="http://www.thermoworks.com/wand-blue" target="_blank" rel="noopener">www.thermoworks.com/wand-blue</a> | 801-756-7705</p>
<p>For warranty, service, and technical assistance, please contact ThermoWorks’ Technical<br />
Support at<strong> (801) 756-7705</strong> or email <a href="http://techsupport@thermoworks.com." target="_blank" rel="noopener">techsupport@thermoworks.com.<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/03/logo-309.png" /></a></p>
<form id="commentform" class="comment-form" action="https://manuals.plus/wp-comments-post.php" method="post" novalidate="">
<p class="form-submit"><input id="comment_post_ID" name="comment_post_ID" type="hidden" value="339699" /><br />
<input id="comment_parent" name="comment_parent" type="hidden" value="0" /></p>
</form>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>

<!--
Performance optimized by W3 Total Cache. Learn more: https://www.boldgrid.com/w3-total-cache/

Page Caching using Disk: Enhanced 

Served from: usemanuals.com @ 2026-09-09 09:59:01 by W3 Total Cache
-->