<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>VOLTECRAFT &#8211; UseManuals</title>
	<atom:link href="http://usemanuals.com/voltecraft/feed/" rel="self" type="application/rss+xml" />
	<link>https://usemanuals.com</link>
	<description>Owner&#039;s manuals for all sorts of products</description>
	<lastBuildDate>Fri, 28 Jul 2023 09:38:26 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.7.2</generator>

<image>
	<url>https://usemanuals.com/wp-content/uploads/2025/02/favicon-32x32-2.png</url>
	<title>VOLTECRAFT &#8211; UseManuals</title>
	<link>https://usemanuals.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>VOLTECRAFT Clamp Meter Manual</title>
		<link>https://usemanuals.com/voltecraft/clamp-meter/</link>
		
		<dc:creator><![CDATA[ItsManual]]></dc:creator>
		<pubDate>Fri, 28 Jul 2023 09:38:26 +0000</pubDate>
				<category><![CDATA[VOLTECRAFT]]></category>
		<guid isPermaLink="false">https://usemanuals.com/?p=179244</guid>

					<description><![CDATA[VOLTECRAFT Clamp Meter Instructions VOLTCRAFT® – TOP PERFORMANCE IN EVERY WAY “For more than 35 years, our product range has been dynamically adapting to the constant changes in the industry. We commit to offering first-class quality to our customers while delivering an excellent cost-performance ratio. This philosophy remains the cornerstone of Voltcraft’s success.” CLAMP METER Nº 1693351 // VC-522 Nº 1693352 // VC-523 Nº 2139578 // VC-523 SE Nº 1693353 // VC-532 Nº 1693354 // VC-533 Robust and ergonomic measuring callipers. All models are equipped with True RMS for reliable measurement of balanced and unbalanced voltages and currents, non-contact AC Voltage Test (NCV), and switch to light up the measuring area. Perfect for servicing machines, in control cabinets and also for measuring high currents in automotive and truck electrics. PACKAGE CONTENTS: Current probe Safety test leads Temperature sensor Type-K Measuring adapter type-K Pocket 3 micro batteries (type AAA)  Safety data sheet Operating instructions FEATURES: CAT III 600 V True RMS Measuring point illumination TECHNICAL DATA: VC-522 VC-523 / VC-523 SE VC-532 VC-533 Item no. 1693351 1693352/2139578 1693353 1693354 Display (counts) 4000 6000 Voltage measurement AC/DC Measurement range voltage AC 0.001 – 600 V Frequency range 50 – 400 Hz Measurement range voltage DC 0.1 mV – 600 V Current measurement AC AC/DC AC AC/DC Measurement range current AC 0.01 A – 400 A 0.1 A – 1000 A Frequency range 50 – 60 Hz Measurement range current DC 0.01 A – 400 A 0.1 A – 1000 A Resistance 0.1 Ω – 40 MΩ 0.1 Ω – 60 MΩ Frequency 10 Hz – 10 kHz Temperature -20 to +760 °C -20 to +1000 °C Capacity 0.01 nF – 4000 µF 0.01 nF – 6000 µF Basic accuracy ±0.8 % Opening for current probe 32 mm 36 mm Power supply 3 micro batteries (AAA, LR3) Dimensions (L x W x H) 208 x 68 x 32 mm 237 x 56 x 34 mm Weight 220 g 328 g EQUIPMENT: Measuring functions: current, voltage, resistance, temperature, capac- itance, frequency, continuity test, diode testing Auto manual range Data hold function Relative reference value function Auto power off function Non-contact AC voltage detection Multi-function thread for optional accessories. Additionally for VC-530 series: Illuminated buttons and rotary switch areas Bar graph display Low-pass filter Max./min. value memory Pulse ratio (duty cycle) Low-impedance function (LoZ) This data sheet is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D 92240 Hirschau (www.conrad.com). All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. This publication represent the technical status at the time of printing. © Copyright 2019 by Conrad Electronic SE. &#160; [...]<p><a class="btn btn-secondary understrap-read-more-link" href="https://usemanuals.com/voltecraft/clamp-meter/">Read More...</a></p>]]></description>
										<content:encoded><![CDATA[<p><strong>VOLTECRAFT Clamp Meter Instructions<br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/0-141-214x300-1.webp" /></strong></p>
<p><strong>VOLTCRAFT® – TOP PERFORMANCE IN EVERY WAY</strong></p>
<p>“For more than 35 years, our product range has been dynamically adapting to the constant changes in the industry. We commit to offering first-class quality to our customers while delivering an excellent cost-performance ratio. This philosophy remains the cornerstone of Voltcraft’s success.”</p>
<p><strong>CLAMP METER</strong></p>
<ul>
<li>Nº 1693351 // VC-522</li>
<li>Nº 1693352 // VC-523</li>
<li>Nº 2139578 // VC-523 SE</li>
<li>Nº 1693353 // VC-532</li>
<li>Nº 1693354 // VC-533</li>
</ul>
<p>Robust and ergonomic measuring callipers.<br />
All models are equipped with True RMS for reliable measurement of balanced and unbalanced voltages and currents, non-contact AC Voltage Test (NCV), and switch to light up the measuring area.<br />
Perfect for servicing machines, in control cabinets and also for measuring high currents in automotive and truck electrics.</p>
<h4>PACKAGE CONTENTS:</h4>
<ul>
<li>Current probe</li>
<li>Safety test leads</li>
<li>Temperature sensor Type-K</li>
<li>Measuring adapter type-K</li>
<li>Pocket</li>
<li>3 micro batteries (type AAA)</li>
<li> Safety data sheet</li>
<li>Operating instructions</li>
</ul>
<h4>FEATURES:</h4>
<ul>
<li>CAT III 600 V</li>
<li>True RMS</li>
<li>Measuring point illumination</li>
</ul>
<h4>TECHNICAL DATA:</h4>
<table width="975">
<tbody>
<tr>
<td width="135"></td>
<td width="48">VC-522</td>
<td width="75">VC-523 / VC-523 SE</td>
<td width="44">VC-532</td>
<td width="63">VC-533</td>
</tr>
<tr>
<td width="135"><strong>Item no.</strong></td>
<td width="48">1693351</td>
<td width="75">1693352/2139578</td>
<td width="44">1693353</td>
<td width="63">1693354</td>
</tr>
<tr>
<td width="135"><strong>Display (counts)</strong></td>
<td colspan="2" width="123">4000</td>
<td colspan="2" width="107">6000</td>
</tr>
<tr>
<td width="135"><strong>Voltage measurement</strong></td>
<td colspan="4" width="229">AC/DC</td>
</tr>
<tr>
<td width="135"><strong>Measurement range voltage AC</strong></td>
<td colspan="4" width="229">0.001 – 600 V</td>
</tr>
<tr>
<td width="135"><strong>Frequency range</strong></td>
<td colspan="4" width="229">50 – 400 Hz</td>
</tr>
<tr>
<td width="135"><strong>Measurement range voltage DC</strong></td>
<td colspan="4" width="229">0.1 mV – 600 V</td>
</tr>
<tr>
<td width="135"><strong>Current measurement</strong></td>
<td width="48">AC</td>
<td width="75">AC/DC</td>
<td width="44">AC</td>
<td width="63">AC/DC</td>
</tr>
<tr>
<td width="135"><strong>Measurement range current AC</strong></td>
<td colspan="2" width="123">0.01 A – 400 A</td>
<td colspan="2" width="107">0.1 A – 1000 A</td>
</tr>
<tr>
<td width="135"><strong>Frequency range</strong></td>
<td colspan="4" width="229">50 – 60 Hz</td>
</tr>
<tr>
<td width="135"><strong>Measurement range current DC</strong></td>
<td width="48"></td>
<td width="75">0.01 A – 400 A</td>
<td width="44"></td>
<td width="63">0.1 A – 1000 A</td>
</tr>
<tr>
<td width="135"><strong>Resistance</strong></td>
<td colspan="2" width="123">0.1 Ω – 40 MΩ</td>
<td colspan="2" width="107">0.1 Ω – 60 MΩ</td>
</tr>
<tr>
<td width="135"><strong>Frequency</strong></td>
<td colspan="4" width="229">10 Hz – 10 kHz</td>
</tr>
<tr>
<td width="135"><strong>Temperature</strong></td>
<td colspan="2" width="123">-20 to +760 °C</td>
<td colspan="2" width="107">-20 to +1000 °C</td>
</tr>
<tr>
<td width="135"><strong>Capacity</strong></td>
<td colspan="2" width="123">0.01 nF – 4000 µF</td>
<td colspan="2" width="107">0.01 nF – 6000 µF</td>
</tr>
<tr>
<td width="135"><strong>Basic accuracy</strong></td>
<td colspan="4" width="229">±0.8 %</td>
</tr>
<tr>
<td width="135"><strong>Opening for current probe</strong></td>
<td colspan="2" width="123">32 mm</td>
<td colspan="2" width="107">36 mm</td>
</tr>
<tr>
<td width="135"><strong>Power supply</strong></td>
<td colspan="4" width="229">3 micro batteries (AAA, LR3)</td>
</tr>
<tr>
<td width="135"><strong>Dimensions (L x W x H)</strong></td>
<td colspan="2" width="123">208 x 68 x 32 mm</td>
<td colspan="2" width="107">237 x 56 x 34 mm</td>
</tr>
<tr>
<td width="135"><strong>Weight</strong></td>
<td colspan="2" width="123">220 g</td>
<td colspan="2" width="107">328 g</td>
</tr>
</tbody>
</table>
<h4>EQUIPMENT:</h4>
<p><strong>Measuring functions:</strong> current, voltage, resistance, temperature, capac- itance, frequency, continuity test, diode testing</p>
<ul>
<li>Auto</li>
<li>manual range</li>
<li>Data hold function</li>
<li>Relative reference value function</li>
<li>Auto power off function</li>
<li>Non-contact AC voltage detection</li>
<li>Multi-function thread for optional accessories.</li>
</ul>
<p><strong>Additionally for VC-530 series:</strong> Illuminated buttons and rotary switch areas</p>
<ul>
<li>Bar graph display</li>
<li>Low-pass filter</li>
<li>Max./min. value memory</li>
<li>Pulse ratio (duty cycle)</li>
<li>Low-impedance function (LoZ)</li>
</ul>
<p>This data sheet is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D 92240 Hirschau (<a href="http://www.conrad.com/" target="_blank" rel="noopener">www.conrad.com</a>). All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. This publication represent the technical status at the time of printing.</p>
<p>© Copyright 2019 by Conrad Electronic SE.</p>
<p>&nbsp;</p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/2-322-300x50-1.webp" /></p>
<form id="commentform" class="comment-form" action="https://manuals.plus/wp-comments-post.php" method="post" novalidate="">
<p class="form-submit">
</form>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>

<!--
Performance optimized by W3 Total Cache. Learn more: https://www.boldgrid.com/w3-total-cache/

Page Caching using Disk: Enhanced 

Served from: usemanuals.com @ 2026-06-13 02:05:58 by W3 Total Cache
-->