<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Thermostates &#8211; UseManuals</title>
	<atom:link href="http://usemanuals.com/thermostates/feed/" rel="self" type="application/rss+xml" />
	<link>https://usemanuals.com</link>
	<description>Owner&#039;s manuals for all sorts of products</description>
	<lastBuildDate>Mon, 14 Aug 2023 10:43:37 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.7.2</generator>

<image>
	<url>https://usemanuals.com/wp-content/uploads/2025/02/favicon-32x32-2.png</url>
	<title>Thermostates &#8211; UseManuals</title>
	<link>https://usemanuals.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Thermostats Temperature and Humidity Controller XY-WTH1 Manual</title>
		<link>https://usemanuals.com/thermostates/thermostats-xy-wth1/</link>
		
		<dc:creator><![CDATA[ItsManual]]></dc:creator>
		<pubDate>Mon, 14 Aug 2023 10:39:20 +0000</pubDate>
				<category><![CDATA[Thermostates]]></category>
		<guid isPermaLink="false">https://usemanuals.com/?p=197555</guid>

					<description><![CDATA[Thermostats Temperature and Humidity Controller Feature Model: XY-WTH1 Temperature range: -20 ° C ~ 60 ° C Humidity range: 00%~100%RH Control accuracy: 0.1 °C 0.1% RH Detection probe: integrated sensor Output type: relay output Output capacity: up to 10A Function Product features are two main types of classification: the functions of temperature and humidity. The function of temperature are as follows: The automatic identification of work mode: The system automatically according to the start/stop temperature, identify work mode; Start temperature &#62; stop temperature, cooling mode’C’. Start temperature &#60; stop temperature, heating mode ‘H’. Cooling mode: When the temperature≥Start temperature, relay conduction, red led on, refrigeration equipment begin to work; When the temperature≤Stop temperature, relay disconnect, red led off, refrigeration equipment stop to work; Heating mode: When the temperature≤Start temperature, relay conduction, red led on, heating equipment begin to work; When the temperature≥Stop temperature, relay disconnect, red led off, heating equipment stop to work; Temperature correction function OFE (-10.0 ~ 10℃): The system is working for a long time and may be biased, through this function correctly, the actual temperature = measuring temperature + calibration value; How to set the start/stop temperature In the running interface, Long Press ‘ TM+ ‘ key more than 3 seconds, into the start temperature settings interface, can be modified by TM+ TM-key, to be modified, waiting for 6s automatic exit and save; In the running interface, Long Press ‘ TM-‘ key more than 3 seconds, into the stop temperature settings interface, can be modified by TM+ TM-key, to be modified after the parameters, waiting for 6s automatic exit and save; The humidity function is as follows The automatic identification of work mode: The system automatically according to the start/stop humidity, identify work mode; Start humidity &#62; stop humidity, dehumidification mode ‘D’. Start humidity &#60; stop humidity, humidification mode ‘E’. Dehumidification mode: When the humidity ≥ Start humidity, relay conduction, green led on, dehumidification equipment begin to work; When the humidity ≤ Shop humidity, relay disconnect, green led off, dehumidification equipment stops to work; Humidification mode: When the humidity ≤ Start humidity, relay conduction, green led on, humidification equipment begin to work; When the humidity ≥ Shop humidity, relay disconnect, green led off, humidification equipment stops to work; Humidification correction function RH (-10.0 ~ 10%): The system is working for a long time and may be biased, through this function correctly, the actual humidity= measuring humidity + calibration value; How to set the start/stop humidity In the running interface, Long Press ‘ RH+ ‘ key more than 3 seconds, into the start humidity settings interface, can be modified by RH+ RH- key, to be modified, waiting for 6s automatic exit and save; In the running interface, Long Press ‘ RH-‘ key more than 3 seconds, into the stop humidity settings interface, can be modified by RH+ RH- key, to be modified after the parameters, waiting for 6s automatic exit and save; Running Interface Description The working mode shows that the current mode (“H/C”, “E/d”) will be synchronized at the front of temperature/humidity, when the setting of temperature/humidity and stop temperature/humidity are completed. Any relay conduction, the upper-left corner of the interface display “out”, if the temperature relay conduction, the flashing display temperature working mode “H/C” to show reminders; if the humidity relay conduction, then flashing display humidity working mode “E/d”, as a reminder; Other features Parameter remote read/set: Through the UART, set the starting temperature/humidity, stop temperature/humidity, temperature/humidity correction parameters; Temperature/Humidity Real-time reporting: If the temperature/humidity reporting function is turned on, the product will detect the temperature/humidity and relay status by the 1s interval, and pass the UART to the terminal to facilitate data collection; Relay enabling (by default): If the relay is disabled, the relay remains disconnected; How to modify the temperature/humidity correction value In the operating interface, double-click the ‘ TM+ ‘ key to enter the correction of the set interface, the downward display correction of the type, the upward display of specific values; (OFE: Temperature correction value RH: Humidity correction value) At this time by a short press ‘ TM-‘ key, switch to modify the parameters, through the RH+ RH-key, modify the specific value of the support long press short; When the parameters have been modified, double-click the ‘ TM+ ‘ key, exit the correction positive setting interface, and save the data; How to enable/disable relay In the running interface, Short press ‘ TM-‘ key, enable/disable the temperature relay(ON: enable OFF: disable), back to the running interface, if the temperature relay is disabled, the temperature symbol ‘ ℃ ‘ flashes to remind. In the running interface, Short press ‘ RH-‘ key, enable/disable the humidity relay (ON: enable OFF: disable), back to the running interface, if the humidity relay is disabled, the humidity symbol ‘% ‘ flashes, as a reminder. Serial control(TTL level) Baud Rate: 9600bps Data bits :8 stop bits :1 crc :none Flow control :none CMD Description Start start data upload Stop stop data upload Read Read the param setting T: ON Temperature relay enable T: OFF Temperature relay disable H: ON Humidity relay enable H: OFF Humidity relay disable TS: XX.X Set start Temperature (-20.0~60.0) TP: XX.X Set stop Temperature (-20.0~60.0) HS: XX.X Set start Humidity (00.0~100.0) HP: XX.X Set stop Humidity (00.0~100.0) TC: XX.X Set Temperature Calibration (-10.0~10.0) HC: XX.X Set Humidity Calibration (-10.0~10.0) Temperature and humidity Data upload format Description Temperature format: Operating mode (H/C), temperature value, temperature relay status; Humidity Format: Operating mode (E/D), humidity value, humidity relay status; H, 20.5℃, CL: Heating operating mode, the current temperature of 20.5 degrees, temperature relay disconnection state; D, 50.4%,OP:Dehumidification working mode, current humidity 50.4%, humidity relay connection; [...]<p><a class="btn btn-secondary understrap-read-more-link" href="https://usemanuals.com/thermostates/thermostats-xy-wth1/">Read More...</a></p>]]></description>
										<content:encoded><![CDATA[<p><b>Thermostats</b><strong> Temperature and Humidity Controller</strong></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/asc-1-300x300-1.webp" /></p>
<h4>Feature</h4>
<ul>
<li><strong>Model:</strong> XY-WTH1</li>
<li><strong>Temperature range:</strong> -20 ° C ~ 60 ° C</li>
<li><strong>Humidity range:</strong> 00%~100%RH</li>
<li><strong>Control accuracy:</strong> 0.1 °C 0.1% RH</li>
<li><strong>Detection probe:</strong> integrated sensor</li>
<li><strong>Output type:</strong> relay output</li>
<li><strong>Output capacity:</strong> up to 10A</li>
</ul>
<h4>Function</h4>
<p>Product features are two main types of classification: the functions of temperature and humidity.<br />
<strong>The function of temperature are as follows:</strong></p>
<ol>
<li><strong>The automatic identification of work mode:</strong><br />
The system automatically according to the start/stop temperature, identify work mode;<br />
Start temperature &gt; stop temperature, cooling mode’C’.<br />
Start temperature &lt; stop temperature, heating mode ‘H’.</li>
<li><strong>Cooling mode:</strong><br />
When the temperature≥Start temperature, relay conduction, red led on, refrigeration equipment begin to work;<br />
When the temperature≤Stop temperature, relay disconnect, red led off, refrigeration equipment stop to work;</li>
<li><strong>Heating mode:</strong><br />
When the temperature≤Start temperature, relay conduction, red led on, heating equipment begin to work;<br />
When the temperature≥Stop temperature, relay disconnect, red led off, heating equipment stop to work;</li>
<li><strong>Temperature correction function OFE (-10.0 ~ 10℃):</strong><br />
The system is working for a long time and may be biased, through this function correctly, the actual temperature = measuring temperature + calibration value;</li>
</ol>
<h4>How to set the start/stop temperature</h4>
<ol>
<li>In the running interface, Long Press ‘ TM+ ‘ key more than 3 seconds, into the start temperature settings interface, can be modified by TM+ TM-key, to be modified, waiting for 6s automatic exit and save;</li>
<li>In the running interface, Long Press ‘ TM-‘ key more than 3 seconds, into the stop temperature settings interface, can be modified by TM+ TM-key, to be modified after the parameters, waiting for 6s automatic exit and save;</li>
</ol>
<h4>The humidity function is as follows</h4>
<ol>
<li><strong>The automatic identification of work mode:</strong><br />
The system automatically according to the start/stop humidity, identify work mode;<br />
Start humidity &gt; stop humidity, dehumidification mode ‘D’.<br />
Start humidity &lt; stop humidity, humidification mode ‘E’.</li>
<li><strong>Dehumidification mode:</strong><br />
When the humidity ≥ Start humidity, relay conduction, green led on, dehumidification equipment begin to work;<br />
When the humidity ≤ Shop humidity, relay disconnect, green led off, dehumidification equipment stops to work;</li>
<li><b>Humidification mode:</b><br />
When the humidity ≤ Start humidity, relay conduction, green led on, humidification equipment begin to work;<br />
When the humidity ≥ Shop humidity, relay disconnect, green led off, humidification equipment stops to work;</li>
<li><b>Humidification correction function RH (-10.0 ~ 10%):</b><br />
The system is working for a long time and may be biased, through this function correctly, the actual humidity= measuring humidity + calibration value;</li>
</ol>
<h4>How to set the start/stop humidity</h4>
<ol>
<li>In the running interface, Long Press ‘ RH+ ‘ key more than 3 seconds, into the start humidity settings interface, can be modified by RH+ RH- key, to be modified, waiting for 6s automatic exit and save;</li>
<li>In the running interface, Long Press ‘ RH-‘ key more than 3 seconds, into the stop humidity settings interface, can be modified by RH+ RH- key, to be modified after the parameters, waiting for 6s automatic exit and save;</li>
</ol>
<h4>Running Interface Description</h4>
<p>The working mode shows that the current mode (“H/C”, “E/d”) will be synchronized at the front of temperature/humidity, when the setting of temperature/humidity and stop temperature/humidity are completed.<br />
Any relay conduction, the upper-left corner of the interface display “out”, if the temperature relay conduction, the flashing display temperature working mode “H/C” to show reminders;<br />
if the humidity relay conduction, then flashing display humidity working mode “E/d”, as a reminder;</p>
<h4>Other features</h4>
<ol>
<li>Parameter remote read/set:<br />
Through the UART, set the starting temperature/humidity, stop temperature/humidity, temperature/humidity correction parameters;</li>
<li>Temperature/Humidity Real-time reporting:<br />
If the temperature/humidity reporting function is turned on, the product will detect the temperature/humidity and relay status by the 1s interval, and pass the UART to the terminal to facilitate data collection;</li>
<li>Relay enabling (by default):<br />
If the relay is disabled, the relay remains disconnected;</li>
</ol>
<p><img fetchpriority="high" decoding="async" class="alignnone wp-image-339178 ezlazyloaded" src="images/6.webp" sizes="" srcset="" alt="" width="523" height="371" data-ezsrcset="https://manuals.plus/wp-content/uploads/2021/07/1-201-300x213.png?ezimgfmt=ng:webp/ngcb1 300w,https://manuals.plus/wp-content/uploads/2021/07/1-201-768x544.png?ezimgfmt=ng:webp/ngcb1 768w,https://manuals.plus/wp-content/uploads/2021/07/1-201.png?ezimgfmt=ng:webp/ngcb1 838w" data-ezsrc="https://manuals.plus/wp-content/uploads/2021/07/1-201-300x213.png?ezimgfmt=rs:523x371/rscb1/ng:webp/ngcb1" /></p>
<h4>How to modify the temperature/humidity correction value</h4>
<ol>
<li>In the operating interface, double-click the ‘ TM+ ‘ key to enter the correction of the set interface, the downward display correction of the type, the upward display of specific values; (OFE: Temperature correction value RH: Humidity correction value)</li>
<li>At this time by a short press ‘ TM-‘ key, switch to modify the parameters, through the RH+ RH-key, modify the specific value of the support long press short;</li>
<li>When the parameters have been modified, double-click the ‘ TM+ ‘ key, exit the correction positive setting interface, and save the data;</li>
</ol>
<h4>How to enable/disable relay</h4>
<p>In the running interface, Short press ‘ TM-‘ key, enable/disable the temperature relay(ON: enable OFF: disable), back to the running interface, if the temperature relay is disabled, the temperature symbol ‘ ℃ ‘ flashes to remind.<br />
In the running interface, Short press ‘ RH-‘ key, enable/disable the humidity relay (ON: enable OFF: disable), back to the running interface, if the humidity relay is disabled, the humidity symbol ‘% ‘ flashes, as a reminder.</p>
<p><strong>Serial control(TTL level)</strong><br />
<strong>Baud Rate:</strong> 9600bps Data bits :8<br />
<strong>stop bits</strong> :1<br />
<strong>crc</strong> :none<br />
<strong>Flow control</strong> :none</p>
<table width="1080">
<tbody>
<tr>
<td width="102"><strong>CMD</strong></td>
<td width="453"><strong>Description</strong></td>
</tr>
<tr>
<td width="102">Start</td>
<td width="453">start data upload</td>
</tr>
<tr>
<td width="102">Stop</td>
<td width="453">stop data upload</td>
</tr>
<tr>
<td width="102">Read</td>
<td width="453">Read the param setting</td>
</tr>
<tr>
<td width="102">T: ON</td>
<td width="453">Temperature relay enable</td>
</tr>
<tr>
<td width="102">T: OFF</td>
<td width="453">Temperature relay disable</td>
</tr>
<tr>
<td width="102">H: ON</td>
<td width="453">Humidity relay enable</td>
</tr>
<tr>
<td width="102">H: OFF</td>
<td width="453">Humidity relay disable</td>
</tr>
<tr>
<td width="102">TS: XX.X</td>
<td width="453">Set start Temperature (-20.0~60.0)</td>
</tr>
<tr>
<td width="102">TP: XX.X</td>
<td width="453">Set stop Temperature (-20.0~60.0)</td>
</tr>
<tr>
<td width="102">HS: XX.X</td>
<td width="453">Set start Humidity (00.0~100.0)</td>
</tr>
<tr>
<td width="102">HP: XX.X</td>
<td width="453">Set stop Humidity (00.0~100.0)</td>
</tr>
<tr>
<td width="102">TC: XX.X</td>
<td width="453">Set Temperature Calibration (-10.0~10.0)</td>
</tr>
<tr>
<td width="102">HC: XX.X</td>
<td width="453">Set Humidity Calibration (-10.0~10.0)</td>
</tr>
</tbody>
</table>
<h4>Temperature and humidity Data upload format Description</h4>
<p>Temperature format: Operating mode (H/C), temperature value, temperature relay status; Humidity Format: Operating mode (E/D), humidity value, humidity relay status;<br />
H, 20.5℃, CL: Heating operating mode, the current temperature of 20.5 degrees, temperature relay disconnection state;<br />
D, 50.4%,OP:Dehumidification working mode, current humidity 50.4%, humidity relay connection;</p>
<p><img decoding="async" class="alignnone wp-image-339179 ezlazyloaded" src="images/7.webp" sizes="" srcset="" alt="" width="472" height="321" data-ezsrcset="https://manuals.plus/wp-content/uploads/2021/07/2-213-300x204.png?ezimgfmt=ng:webp/ngcb1 300w,https://manuals.plus/wp-content/uploads/2021/07/2-213-768x523.png?ezimgfmt=ng:webp/ngcb1 768w,https://manuals.plus/wp-content/uploads/2021/07/2-213.png?ezimgfmt=ng:webp/ngcb1 873w" data-ezsrc="https://manuals.plus/wp-content/uploads/2021/07/2-213-300x204.png?ezimgfmt=rs:472x321/rscb1/ng:webp/ngcb1" /></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/3-197-300x236-1.webp" /></p>
<form id="commentform" class="comment-form" action="https://manuals.plus/wp-comments-post.php" method="post" novalidate="">
<p class="form-submit">
</form>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Thermostates Digital Thermostat Switch XY-WT01 Manual</title>
		<link>https://usemanuals.com/thermostates/xy-wt01-thermostat/</link>
		
		<dc:creator><![CDATA[ItsManual]]></dc:creator>
		<pubDate>Mon, 14 Aug 2023 10:43:37 +0000</pubDate>
				<category><![CDATA[Thermostates]]></category>
		<guid isPermaLink="false">https://usemanuals.com/?p=197613</guid>

					<description><![CDATA[XY-WT01 Digital Thermostat Switch Features: Set Temperature –Set T; Backlash Temperature–Back T Heating Mode H: When Temperature ≤ Set T ­ Back T; Relay conduction, heating equipment begin to work; when temperature ≥ Set T, Relay disconnect, heating equipment stop work; Refrigeration mode C: When Temperature ≥ Set T+Back T; Relay conduction, refrigeration equipment begin to work; When Temperature ≤ Set T; Relay conduction, refrigeration equipment stop work; High-Temperature Alarm ALA When Temperature ≥ Alarm Temperature, The system opens the sound and light alarm and disconnects the relay, any key stops the sound light; Delay Start OPH: When a normal heating or refrigeration work is done, the system starts to time T, and only after the T ≥ OPH, the system can carry out the next round of heating or refrigeration work; Temperature Correction Function OFE(-10.0 ~ 10.0): The system will work for a long time and may have deviations that can be corrected by this function, Temperature = Measured + Calibration Parameter Remote Read/Set: The parameters such as setting temperature, backlash temperature, and temperature correction can be set through UART. Real-time Temperature Report: If the temperature reporting function is turned on, the product is transmitted to the terminal by the UART at 1s intervals, which facilitates data collection; Relay enable (default enable): If the relay is disabled, the relay remains disconnected; Restore Factory Settings: At the same time press the STOP, set key more than 3S, restore factory settings; Working mode setting /backlash temperature : In the running interface, short press SET key, enter the Quick setting interface; After entering the Quick Setup interface, switch the parameters Through the UP DOWN key, modify the parameter value, support short press/long press; Long press SET to build more than 3S or continuous 6S without any key operation, exit quickly set the interface, and save parameters; Alarm temperature/Delay Start /temperature correction: In the operating interface, long press SET more than 3s, enter the parameters to set the interface; Enter the parameter to set the interface, through the short press SET key to switch to set the parameters; Through the UP DOWN key, modify the parameter value, support short press/long press; Long press SET3s above or continuous 6S without any key operation, exit parameter set interface, and save parameters; How to turn on high-temperature alarm (default off): Enter the parameter setting interface, switch to the alarm parameter ALA, turn on or off the high-temperature alarm function by short pressing the STOP button, and if the high-temperature alarm function closes, ALA displays ‘—-‘ as a reminder; How to turn on delay start (default 0ff): Enter parameter setting interface, switch to alarm parameter OPH, turn on or off high-temperature alarm function by short Press STOP button if high-temperature alarm function closes, OPH show ‘—‘ to remind; Serial Control (MCU UART) Communication standards: 9600bpsData bits: 8 Stop Bits: 1 CRC: none Flow control: none CMD Description Start start data upload Stop stop data upload Read Read the param setting T: ON Temperature relay enable T: OFF Temperature relay disable H: ON Humidity relay enable H: OFF Humidity relay disable TS: XX.X Set start Temperature (-20.0-60.0) TP: XX.X Set stop Temperature (-20.0-60.0) HS: XX.X Set start Humidity (00.0100.0) HP: XX.X Set stop Humidity (00.0100.0) TC: XX.X Set Temperature Calibration (-10.0-10.0) HC: XX.X Set Humidity Calibration (-10.0-10.0) Product Name: digital temperature controller Product model : XY-WT0O1 Power supply: DC6.0~30V Temp range: -50°C~110°C ; «4 EEL xe) , , Control accuracy: 0.1°C Measurement input: NTC10K/B3950 Refresh frequency : 0.5second Output type: relay output 10A Type of probe: L:0.5 meter of waterproof probe Temperature range-20-110 ºC [...]<p><a class="btn btn-secondary understrap-read-more-link" href="https://usemanuals.com/thermostates/xy-wt01-thermostat/">Read More...</a></p>]]></description>
										<content:encoded><![CDATA[<p><strong>XY-WT01 Digital Thermostat Switch</strong></p>
<h4>Features:</h4>
<h4><strong>Set Temperature –Set T; Backlash Temperature–Back T</strong></h4>
<ol>
<li><strong>Heating Mode H:</strong><br />
When Temperature ≤ Set T ­ Back T; Relay conduction, heating equipment begin to work; when temperature ≥ Set T, Relay disconnect, heating equipment stop work;</li>
<li><strong>Refrigeration mode C:</strong><br />
When Temperature ≥ Set T+Back T; Relay conduction, refrigeration equipment begin to work; When Temperature ≤ Set T; Relay conduction, refrigeration equipment stop work;</li>
<li><strong>High-Temperature Alarm ALA</strong><br />
When Temperature ≥ Alarm Temperature, The system opens the sound and light alarm and disconnects the relay, any key stops the sound light;</li>
<li><strong>Delay Start OPH:</strong><br />
When a normal heating or refrigeration work is done, the system starts to time T, and only after the T ≥ OPH, the system can carry out the next round of heating or refrigeration work;</li>
<li><strong>Temperature Correction Function OFE(-10.0 ~ 10.0):</strong><br />
The system will work for a long time and may have deviations that can be corrected by this function, Temperature = Measured + Calibration</li>
<li><strong>Parameter Remote Read/Set:</strong><br />
The parameters such as setting temperature, backlash temperature, and temperature correction can be set through UART.</li>
<li><strong>Real-time Temperature Report:</strong><br />
If the temperature reporting function is turned on, the product is transmitted to the terminal by the UART at 1s intervals, which facilitates data collection;</li>
<li><strong>Relay enable (default enable):</strong><br />
If the relay is disabled, the relay remains disconnected;</li>
<li><strong>Restore Factory Settings:</strong><br />
At the same time press the STOP, set key more than 3S, restore factory settings;</li>
</ol>
<h4><strong>Working mode setting /backlash temperature :</strong></h4>
<ol>
<li>In the running interface, short press SET key, enter the Quick setting interface;</li>
<li>After entering the Quick Setup interface, switch the parameters</li>
<li>Through the UP DOWN key, modify the parameter value, support short press/long press;</li>
<li>Long press SET to build more than 3S or continuous 6S without any key operation, exit quickly set the interface, and save parameters;</li>
</ol>
<h4><strong>Alarm temperature/Delay Start /temperature correction:</strong></h4>
<ol>
<li>In the operating interface, long press SET more than 3s, enter the parameters to set the interface;</li>
<li>Enter the parameter to set the interface, through the short press SET key to switch to set the parameters;</li>
<li>Through the UP DOWN key, modify the parameter value, support short press/long press;</li>
<li>Long press SET3s above or continuous 6S without any key operation, exit parameter set interface, and save parameters;</li>
</ol>
<h4><strong>How to turn on high-temperature alarm (default off):</strong></h4>
<p>Enter the parameter setting interface, switch to the alarm parameter ALA, turn on or off the high-temperature alarm function by short pressing the STOP button, and if the high-temperature alarm function closes, ALA displays ‘—-‘ as a reminder;</p>
<h4><strong>How to turn on delay start (default 0ff):</strong></h4>
<p>Enter parameter setting interface, switch to alarm parameter OPH, turn on or off high-temperature alarm function by short Press STOP button if high-temperature alarm function closes, OPH show ‘—‘ to remind;</p>
<p>Serial Control (MCU UART)<br />
Communication standards: 9600bpsData bits: 8<br />
Stop Bits: 1<br />
CRC: none<br />
Flow control: none</p>
<table width="1226">
<tbody>
<tr>
<td width="157"><strong>CMD</strong></td>
<td width="680"><strong>Description</strong></td>
</tr>
<tr>
<td width="157">Start</td>
<td width="680">start data upload</td>
</tr>
<tr>
<td width="157">Stop</td>
<td width="680">stop data upload</td>
</tr>
<tr>
<td width="157">Read</td>
<td width="680">Read the param setting</td>
</tr>
<tr>
<td width="157">T: ON</td>
<td width="680">Temperature relay enable</td>
</tr>
<tr>
<td width="157">T: OFF</td>
<td width="680">Temperature relay disable</td>
</tr>
<tr>
<td width="157">H: ON</td>
<td width="680">Humidity relay enable</td>
</tr>
<tr>
<td width="157">H: OFF</td>
<td width="680">Humidity relay disable</td>
</tr>
<tr>
<td width="157">TS: XX.X</td>
<td width="680">Set start Temperature (-20.0-60.0)</td>
</tr>
<tr>
<td width="157">TP: XX.X</td>
<td width="680">Set stop Temperature (-20.0-60.0)</td>
</tr>
<tr>
<td width="157">HS: XX.X</td>
<td width="680">Set start Humidity (00.0100.0)</td>
</tr>
<tr>
<td width="157">HP: XX.X</td>
<td width="680">Set stop Humidity (00.0100.0)</td>
</tr>
<tr>
<td width="157">TC: XX.X</td>
<td width="680">Set Temperature Calibration (-10.0-10.0)</td>
</tr>
<tr>
<td width="157">HC: XX.X</td>
<td width="680">Set Humidity Calibration (-10.0-10.0)</td>
</tr>
</tbody>
</table>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/Thermostates-Digital-Thermostat-Overview.webp" /></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/Thermostates-Digital-Thermostat-Overview-2.webp" /></p>
<p><strong>Product Name:</strong> digital temperature controller<br />
<strong>Product model :</strong> XY-WT0O1<br />
<strong>Power supply:</strong> DC6.0~30V<br />
<strong>Temp range:</strong> -50°C~110°C ; «4 EEL xe) , ,<br />
<strong>Control accuracy:</strong> 0.1°C<br />
<strong>Measurement input:</strong> NTC10K/B3950<br />
<strong>Refresh frequency :</strong> 0.5second<br />
<strong>Output type:</strong> relay output 10A<br />
<strong>Type of probe:</strong> L:0.5 meter of waterproof probe<br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/Thermostates-Digital-Thermostat-Overview-3.webp" /><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/Thermostates-Digital-Thermostat-Overview-4.webp" /></p>
<p>Temperature range-20-110 ºC<br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/Thermostates-Digital-Thermostat-Overview-5.webp" /></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/Thermostates-Digital-Thermostat-Overview-6.webp" /></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/Thermostates-Digital-Thermostat-Overview-7.webp" /></p>
<form id="commentform" class="comment-form" action="https://manuals.plus/wp-comments-post.php" method="post" novalidate="">
<p class="form-submit">
</form>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>

<!--
Performance optimized by W3 Total Cache. Learn more: https://www.boldgrid.com/w3-total-cache/

Page Caching using Disk: Enhanced 

Served from: usemanuals.com @ 2026-04-25 11:12:01 by W3 Total Cache
-->