<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>solplanet &#8211; UseManuals</title>
	<atom:link href="http://usemanuals.com/solplanet/feed/" rel="self" type="application/rss+xml" />
	<link>https://usemanuals.com</link>
	<description>Owner&#039;s manuals for all sorts of products</description>
	<lastBuildDate>Wed, 23 Aug 2023 05:20:41 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.7.2</generator>

<image>
	<url>https://usemanuals.com/wp-content/uploads/2025/02/favicon-32x32-2.png</url>
	<title>solplanet &#8211; UseManuals</title>
	<link>https://usemanuals.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>solplanet Single Phase Inverter Solar ASW1000S-S, ASW1500S-S Manual</title>
		<link>https://usemanuals.com/solplanet/inverter-solar-asw1000s-s/</link>
		
		<dc:creator><![CDATA[ItsManual]]></dc:creator>
		<pubDate>Wed, 23 Aug 2023 05:20:41 +0000</pubDate>
				<category><![CDATA[solplanet]]></category>
		<guid isPermaLink="false">https://usemanuals.com/?p=206254</guid>

					<description><![CDATA[Solplanet Single Phase Inverter Solar Installation Guide Safety Instruction The contents of this document will be updated irregularly for product version up- grade or other reasons. Unless otherwise specified,this document only works as guide. All statements, information and suggestions in this document do not constitute any guarantee. This product can only be installed, commissioned, operated and maintained by technicians who have carefully read and fully understood the user manual. This product must only be connected with PV modules of protection class II( in  accordance with IEC 61730, application class A).PV modules with a high capacitance to ground must only be used if their capacity does not exceed 1 F.Do not connect any sources of energyother than PV modules to the product. When exposed to sunlight, the PV modules generate dangerous high DC voltage which is present in the DC cable conductors and live components. Touching live DC cable conductors and live components can result in lethal injuries due to electric shock. Allcomponents must remain within their permitted operating ranges at all times. Theproduct complies with Electromagnetic compatibility 2014/30/EU, Low Voltage Directive 2014/35/EU and Radio Equipment Directive 2014/53/EU. Mounting Environment Ensure that the inverter is installed out of the reach of children. To ensure best operating status and prolonged service life, the mounting ambient temperature of the inverter shoul dbe ≤40°C. To avoid direct sunlight, rain, snow, pounding on the inverter, it is suggested to mount the inverter in places with a top protective  roof. Do not completely cover the top of the inverter. Themounting condition must be suitable for the weight and size of the inverter. The inverter is suitable to be mounted on solid wall that is vertical or tilted backwards (Max. 15°). It is not recommended to install the inverter on wall made of plaster- boards or similar materials. The inverter may make noise when working. To ensure adequate heat dissipation, the clearances between the inverter and other objects are recommended as follows: Scope of delivery Inverter x1 Wall mounting bracket x1 DC connector x2 Communication cover x1 (optional) Documentation x1 Screw accessory x1 GPRS/WiFi stick x1 (optional) AC connector x1 Smart meter terminal x1 Magnetic ring x1 (optional) Inverter’smounting Use a Φ10mm bit to drill 3 holes at a depth  of about 70mm according to the location of the wall mounting bracket. Insert wall plugs into the wall and fix the wall mounting bracket to the wall by screwing three self-tappingscrews(SW10). Hang the inverter to the wall mounting bracket. Secure the inverter to the wall mounting bracket using M4 screw. V.ACconnection All electrical installations must be done in accordance with all local and national rules. Make sure that all DC switches and AC circuit breakers have been discon- nected before establishing electrical connection. Otherwise, the high voltage within the inverter may lead to electrical shock. In accordance with safety regulations, the inverter need be grounded firmly. When poor groundconnection(PE) occurs, the inverter will report PE grounding error. Please check and ensure that the inverter is grounded firmly or contact AISWEI service. AC cable requirements are as follows. Insert the conductor into a suitable ferrule acc. to DIN 46228-4 and  crimp the contact . Object Description  Value A External diameter 9-14mm B Copper conductor cross-section 2.5-6mm 2 C Stripping length of the insulated conductors 13mm D Stripping length of the cable outer sheath 53mm The PE conductor must be 2 mm longer than the Land N conductors. Loosen the swivel nut of AC connector. Insert the crimped conductors into correspondingterminalsandtighten screws  with the accompanied Allen key. Torque: 2.0Nm Insert the adapter to the socket element,  stuff the seal ring into the adapter and  tighten the swivel nut. Plug the AC connector into the socket for the AC connection. If required, you can connect a second protective conductor as potentiality bonding. Object Explanation M4×10 screw Screwdriver type: PH2,torque: 1.6Nm OT terminal lug Customer provided,type :M4 Grounding cable Copper conductor cross-section: 2.5-6mm 2 VI.DC connection Make sure PV modules have good insulation against ground. On the coldest day based on statistical records, the Max. open-circuit volt- age of  the PV modules must not exceed the  Max. input voltage of the inverter. Check the polarit of DC cables. Ensure that DC switch has been disconnected. Do not disconnect  DC connectors under load. Please refer to “DC Connector Installation Guide”. Before DC connection, insert the DC plug connectors with sealing plugs into DC input connectors of the inverter toensureprotectiondegree. VII.Communication setup Separate communication cables from power cables and serious interference sources. The communication cables must be CAT-5E or higher-level shield cables. Pin assignment complies with EIA/TIA 568B standard. For outdoor use, the communication cables must be UV-resistant. The total length of communication cable cannot exceed 1000m. If only one communication cable is connected, insert a sealing plug into the unused hole of sealingringofthecablegland. Beforeconnecting communication cables, ensure the protective film or  communication plate attached to the communication opening on the inverter is sealed tightly. COM1: RS485(optional) RS485 cable pin assignment as below. Pin 1=TX_RS485A Pin 2=TX_RS485B Pin 3=NC Pin 4=GND Pin 5=GND Pin 6=NC Pin 7=+7V Pin 8=+7V 2.Loosen the swivel nut of the cable gland on the communication cover, remove sealing plugs and lead the cable through the swivel nut, sealing ring, communicationcover and magnetic ring. 3.Insert the cable into the socket, attach the communication cover to inverter with M4 screws and tighten the swivel nut. Screwdriver type: PH2, torque: 1.6Nm. COM2:GPRS/WiFi PIN PIN1 PIN2 PIN3 PIN4 Assignment VCC GND RS485A RS485B Theconnectionrefersto“GPRS/WiFi-stickUserManual” Smart meter Remove the communication plate from the inverter. Loosen the swivel nut of the cable  gland on     thecommunication plate, remove the sealing plug and lead  the strippedcable through the cable gland and communication plate, press the latch of the smart meter terminaland insert thestripped cable accordingly. Make sure the cableis connected firmly. Insert the smart meter terminal to the socket, attach communication plate tithe inverter with M4 screws, and tighten the swivelnut.Screwdrivertype: PH2, torque: 1.6Nm If communication cover used, remove only one sealing plug of the cable gland to thread the cable.Detailed installation process follows above steps. VIII.Commissioning Check that the inverter is grounded reliably. Check that the ventilationcondition surrounding the inverter is good. Check that the grid voltage at the point of connection of the inverter is within thepermittedrange. Check that the sealing plugs in DC connectors and the communication cable glandare sealed tightly. Check that grid connection regulations and other parameter settings meet safety requirements. Switch on AC circuit breaker between the inverter and the grid. Switch on DC switch. When there is sufficient DC power applied and the grid conditions are met, the inverter will start to operate automatically. IX.EU Declaration of Conformity Within the scope of the EU directives: – Electromagnetic compatibility 2014/30/EU (L 96/79-106 ，March 29, 2014  (EMC)- Low voltagedirective 2014/35/EU (L 96/357-374 ，March 29, 2014 (LVD)- Radio equipment directive 2014/53/EU (L 153/62-106，May 22, 2014)(RED) AISWEI New Energy Technology Jiangsu Co., Ltd. confirms here with that the inerternmentionedin this document are in compliance with the fundamental requirements and other relevant provisions of the above mentioned directives. The entire EU Declaration of Conformity can be found at www.aiswei-tech.com. X.Technical Data Technical Data ASW1000S-S ASW1500S-S ASW2000S-S ASW3000S-S DC Input Max. PV modules power(STC) 1500W 2250W 3000W 4500W Max. DC input voltage 580V MPP voltage range 80-550V Max. DC input current 12A Max. DC input short current 18A Max. DC input current, per MPPT 12A Number of MPPT/strings per MPPT AC Output 1/1 Rated active power 1000W 1500W 2000W 3000W Max. apparent power 1000VA 1500VA 2000VA 3000VA Rated grid voltage 220/230V Rated grid frequency 50/60Hz Max. AC output current 5A 7.5A 10A 13.6A Adjustable displacement power factor 0.8 ind    0.8 cap Harmonic distortion (THD) at Pac.r General Data &#60; 3% Dimensions (W x H x D) 320×264×94mm Weight 6.5kg &#60; 25dB(A)@1m Noise emission (typical) DC connection Plug-in DC connector AC connection Plug-in AC connector Communication GPRS/WiFi , RS485(Optional) Display LED Mounting Wall mounting Cooling Convection Operating temperature range -25…+60℃ Relative  humidity  (non-condensing) 4000m(           0…100%                  ) Max. operating altitude Derating above 3000m Degree of protection IP65 Climate Category 4K4H Topology Transformerless XI.Contact If you have any technical problems with our products, please contact our service. We require the following information in order to provide you with the necessary  assistance: -Inverterdevice type -Inverterserialnumber Type and number of connected PV modules -Error code -Mounting location -Warrantycard AISWEI New Energy Technology(Jiangsu)Co., Ltd.  Tel.: +865126937  0998Fax: +86 5126937 3159 Web: service.china@aiswei tech.com Add.: Building 9, No. 198 Xiangyang Road, Suzhou, China AISWEI Pty Ltd. Tel.: +61 3909 88674 Add.: Level 40, 140 William Street, Melbourne VIC 3000 AISWEI B.V. Add.: Muiderstraat 9/G, 1011 PZ Amsterdam North Holland, Netherlands http://www.aisweicloud.com/data/download.jsp [...]<p><a class="btn btn-secondary understrap-read-more-link" href="https://usemanuals.com/solplanet/inverter-solar-asw1000s-s/">Read More...</a></p>]]></description>
										<content:encoded><![CDATA[<p><strong>Solplanet Single Phase Inverter Solar Installation Guide</strong></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/00-37-259x300-1.webp" /></p>
<h4>Safety Instruction</h4>
<ol>
<li>The contents of this document will be updated irregularly for product version up- grade or other reasons. Unless otherwise specified,this document only works as guide. All statements, information and suggestions in this document do not constitute any guarantee.</li>
<li>This product can only be installed, commissioned, operated and maintained by technicians who have carefully read and fully understood the user manual.</li>
<li>This product must only be connected with PV modules of protection class II( in  accordance with IEC 61730, application class A).PV modules with a high capacitance to ground must only be used if their capacity does not exceed 1 F.Do not connect any sources of energyother than PV modules to the product.</li>
<li>When exposed to sunlight, the PV modules generate dangerous high DC voltage which is present in the DC cable conductors and live components. Touching live DC cable conductors and live components can result in lethal injuries due to electric shock.</li>
<li>Allcomponents must remain within their permitted operating ranges at all times.</li>
<li>Theproduct complies with Electromagnetic compatibility 2014/30/EU, Low Voltage Directive 2014/35/EU and Radio Equipment Directive 2014/53/EU.</li>
</ol>
<h4>Mounting Environment</h4>
<ol>
<li>Ensure that the inverter is installed out of the reach of children.<br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/02-6-105x300-1.webp" /></li>
<li>To ensure best operating status and prolonged service life, the mounting ambient temperature of the inverter shoul dbe ≤40°C.<br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/03-5-104x300-1.webp" /></li>
<li>To avoid direct sunlight, rain, snow, pounding on the inverter, it is suggested to mount the inverter in places with a top protective  roof. Do not completely cover the top of the inverter.<br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/04-5-111x300-1.webp" /></li>
<li>Themounting condition must be suitable for the weight and size of the inverter. The inverter is suitable to be mounted on solid wall that is vertical or tilted backwards<br />
(Max. 15°). It is not recommended to install the inverter on wall made of plaster-<br />
boards or similar materials. The inverter may make noise when working.<br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/05-4.webp" /></li>
<li>To ensure adequate heat dissipation, the clearances between the inverter and other objects are recommended as follows:<br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/06-3-278x300-1.webp" /></li>
</ol>
<h4>Scope of delivery</h4>
<p><strong>Inverter x1</strong></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/07-3.webp" /></p>
<p><strong>Wall mounting bracket x1</strong></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/08-3.webp" /></p>
<p><strong>DC connector x2</strong></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/09.webp" /></p>
<p><strong>Communication cover x1 (optional)</strong></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/10-173.webp" /></p>
<p><strong>Documentation x1</strong></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/11-164.webp" /></p>
<p><strong>Screw accessory x1</strong></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/12-153.webp" /></p>
<p><strong>GPRS/WiFi stick x1 (optional)</strong></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/13-142.webp" /></p>
<p><strong>AC connector x1</strong></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/14-133.webp" /></p>
<p><strong>Smart meter terminal x1</strong></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/15-128.webp" /></p>
<p><strong>Magnetic ring x1 (optional)</strong></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/16-119.webp" /></p>
<h4>Inverter’smounting</h4>
<p>Use a Φ10mm bit to drill 3 holes at a depth  of about 70mm according to the location of the wall mounting bracket.</p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/17-114.webp" /><br />
Insert wall plugs into the wall and fix the wall mounting bracket to the wall by screwing three self-tappingscrews(SW10).</p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/18-104.webp" /><br />
Hang the inverter to the wall mounting bracket.</p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/19-98.webp" /><br />
Secure the inverter to the wall mounting bracket using M4 screw.</p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/20-91.webp" /></p>
<h4>V.ACconnection</h4>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/26-77.webp" /><br />
All electrical installations must be done in accordance with all local and national rules.</p>
<ul>
<li>Make sure that all DC switches and AC circuit breakers have been discon-<br />
nected before establishing electrical connection. Otherwise, the high<br />
voltage within the inverter may lead to electrical shock.</li>
<li>In accordance with safety regulations, the inverter need be grounded firmly. When poor groundconnection(PE) occurs, the inverter will report PE<br />
grounding error. Please check and ensure that the inverter is grounded firmly or contact AISWEI service.</li>
</ul>
<ol>
<li>AC cable requirements are as follows. Insert the conductor into a suitable ferrule acc. to DIN 46228-4 and  crimp the contact .<br />
<table width="1003">
<tbody>
<tr>
<td width="73">Object</td>
<td width="330">Description</td>
<td width="235"> Value</td>
</tr>
<tr>
<td width="73">A</td>
<td width="330">External diameter</td>
<td width="235">9-14mm</td>
</tr>
<tr>
<td width="73">B</td>
<td width="330">Copper conductor cross-section</td>
<td width="235">2.5-6mm 2</td>
</tr>
<tr>
<td width="73">C</td>
<td width="330">Stripping length of the insulated conductors</td>
<td width="235">13mm</td>
</tr>
<tr>
<td width="73">D</td>
<td width="330">Stripping length of the cable outer sheath</td>
<td width="235">53mm</td>
</tr>
<tr>
<td colspan="3" width="638">The PE conductor must be 2 mm longer than the Land N conductors.</td>
</tr>
</tbody>
</table>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/21-93.webp" /></li>
<li>Loosen the swivel nut of AC connector. Insert the crimped conductors into correspondingterminalsandtighten screws  with the accompanied Allen key. Torque: 2.0Nm<br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/22-98.webp" /></li>
<li>Insert the adapter to the socket element,  stuff the seal ring into the adapter and  tighten the swivel nut.<br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/23-86.webp" /></li>
<li>Plug the AC connector into the socket for the AC connection.<br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/24-88.webp" /></li>
<li>If required, you can connect a second protective conductor as potentiality bonding.</li>
</ol>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/25-78.webp" /></p>
<table width="871">
<tbody>
<tr>
<td width="319"><strong>Object</strong></td>
<td width="319"><strong>Explanation</strong></td>
</tr>
<tr>
<td width="319">M4×10 screw</td>
<td width="319">Screwdriver type: PH2,torque: 1.6Nm</td>
</tr>
<tr>
<td width="319">OT terminal lug</td>
<td width="319">Customer provided,type :M4</td>
</tr>
<tr>
<td width="319">Grounding cable</td>
<td width="319">Copper conductor cross-section: 2.5-6mm 2</td>
</tr>
</tbody>
</table>
<h4>VI.DC connection</h4>
<ul>
<li>Make sure PV modules have good insulation against ground.</li>
<li>On the coldest day based on statistical records, the Max. open-circuit volt- age of  the PV modules must not exceed the  Max. input voltage of the inverter.</li>
<li>Check the polarit of DC cables.</li>
<li>Ensure that DC switch has been disconnected.</li>
<li>Do not disconnect  DC connectors under load.</li>
</ul>
<ol>
<li>Please refer to “DC Connector Installation Guide”.</li>
<li>Before DC connection, insert the DC plug connectors with sealing plugs into DC input connectors of the inverter toensureprotectiondegree.</li>
</ol>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/27-77-300x187-1.webp" /></p>
<h4>VII.Communication setup</h4>
<ul>
<li>Separate communication cables from power cables and serious interference sources.</li>
<li>The communication cables must be CAT-5E or higher-level shield cables. Pin<br />
assignment complies with EIA/TIA 568B standard. For outdoor use, the communication cables must be UV-resistant. The total length of communication<br />
cable cannot exceed 1000m.</li>
<li>If only one communication cable is connected, insert a sealing plug into the<br />
unused hole of sealingringofthecablegland.</li>
<li>Beforeconnecting communication cables, ensure the protective film or  communication plate attached to the communication opening on the inverter is sealed tightly.</li>
</ul>
<ol>
<li>COM1: RS485(optional)<br />
RS485 cable pin assignment as below.<br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/28-74.webp" /></li>
</ol>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/29-67-159x300-1.webp" /><br />
Pin 1=TX_RS485A<br />
Pin 2=TX_RS485B<br />
Pin 3=NC<br />
Pin 4=GND<br />
Pin 5=GND<br />
Pin 6=NC<br />
Pin 7=+7V<br />
Pin 8=+7V</p>
<p>2.Loosen the swivel nut of the cable gland<br />
on the communication cover, remove<br />
sealing plugs and lead the cable through<br />
the swivel nut, sealing ring, communicationcover and magnetic ring.</p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/30-70-300x128-1.webp" /></p>
<p>3.Insert the cable into the socket, attach the communication cover to inverter with M4 screws and tighten the swivel nut. Screwdriver type: PH2, torque: 1.6Nm.</p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/31-64-300x244-1.webp" /></p>
<p><strong>COM2:GPRS/WiFi</strong></p>
<table width="721">
<tbody>
<tr>
<td width="85">PIN</td>
<td width="66">PIN1</td>
<td width="60">PIN2</td>
<td width="66">PIN3</td>
<td width="78">PIN4</td>
</tr>
<tr>
<td width="85">Assignment</td>
<td width="66">VCC</td>
<td width="60">GND</td>
<td width="66">RS485A</td>
<td width="78">RS485B</td>
</tr>
</tbody>
</table>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/32-59.webp" /></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/33-61-300x284-1.webp" /></p>
<p>Theconnectionrefersto“GPRS/WiFi-stickUserManual”</p>
<p><strong>Smart meter</strong></p>
<ol>
<li>Remove the communication plate from the inverter.<br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/34-56-300x124-1.webp" /></li>
<li>Loosen the swivel nut of the cable  gland on     thecommunication plate, remove the sealing plug and lead  the strippedcable through the cable gland and communication plate, press the latch of the smart meter terminaland insert thestripped cable accordingly. Make sure the cableis connected firmly.<br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/35-50-300x143-1.webp" /></li>
<li>Insert the smart meter terminal to the socket, attach communication plate tithe inverter with M4 screws, and tighten the swivelnut.Screwdrivertype: PH2, torque: 1.6Nm<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/36-48-300x179-1.webp" /></li>
<li>If communication cover used, remove only one sealing plug of the cable gland to thread the cable.Detailed installation process follows above steps.</li>
</ol>
<h4>VIII.Commissioning</h4>
<ul>
<li>Check that the inverter is grounded reliably.</li>
<li>Check that the ventilationcondition surrounding the inverter is good.</li>
<li>Check that the grid voltage at the point of connection of the inverter is within<br />
thepermittedrange.</li>
<li>Check that the sealing plugs in DC connectors and the communication cable glandare sealed tightly.</li>
<li>Check that grid connection regulations and other parameter settings meet<br />
safety requirements.</li>
</ul>
<ol>
<li>Switch on AC circuit breaker between the inverter and the grid.</li>
<li>Switch on DC switch.</li>
<li>When there is sufficient DC power applied and the grid conditions are met, the inverter will start to operate automatically.</li>
</ol>
<h4>IX.EU Declaration of Conformity</h4>
<p>Within the scope of the EU directives: – Electromagnetic compatibility 2014/30/EU (L 96/79-106 ，March 29, 2014  (EMC)- Low voltagedirective 2014/35/EU (L 96/357-374 ，March 29, 2014 (LVD)- Radio equipment directive 2014/53/EU (L 153/62-106，May 22, 2014)(RED)<br />
AISWEI New Energy Technology Jiangsu Co., Ltd. confirms here with that the</p>
<p>inerternmentionedin this document are in compliance with the fundamental requirements and other relevant provisions of the above mentioned directives. The entire EU Declaration of Conformity can be found at<a href="http://www.aiswei-tech.com./" target="_blank" rel="noopener"> www.aiswei-tech.com.</a></p>
<h4>X.Technical Data</h4>
<table width="1014">
<tbody>
<tr>
<td width="186">Technical Data</td>
<td width="68">ASW1000S-S</td>
<td width="68">ASW1500S-S</td>
<td width="68">ASW2000S-S</td>
<td width="68">ASW3000S-S</td>
</tr>
<tr>
<td width="186">DC Input</td>
<td colspan="4" width="270"></td>
</tr>
<tr>
<td width="186">Max. PV modules power(STC)</td>
<td width="68">1500W</td>
<td width="68">2250W</td>
<td width="68">3000W</td>
<td width="68">4500W</td>
</tr>
<tr>
<td width="186">Max. DC input voltage</td>
<td colspan="4" width="270">580V</td>
</tr>
<tr>
<td width="186">MPP voltage range</td>
<td colspan="4" width="270">80-550V</td>
</tr>
<tr>
<td width="186">Max. DC input current</td>
<td colspan="4" width="270">12A</td>
</tr>
<tr>
<td width="186">Max. DC input short current</td>
<td colspan="4" width="270">18A</td>
</tr>
<tr>
<td width="186">Max. DC input current, per MPPT</td>
<td colspan="4" width="270">12A</td>
</tr>
<tr>
<td width="186">Number of MPPT/strings per MPPT</p>
<p>AC Output</td>
<td colspan="4" width="270">1/1</td>
</tr>
<tr>
<td width="186"></td>
<td colspan="4" width="270"></td>
</tr>
<tr>
<td width="186">Rated active power</td>
<td width="68">1000W</td>
<td width="68">1500W</td>
<td width="68">2000W</td>
<td width="68">3000W</td>
</tr>
<tr>
<td width="186">Max. apparent power</td>
<td width="68">1000VA</td>
<td width="68">1500VA</td>
<td width="68">2000VA</td>
<td width="68">3000VA</td>
</tr>
<tr>
<td width="186">Rated grid voltage</td>
<td colspan="4" width="270">220/230V</td>
</tr>
<tr>
<td width="186">Rated grid frequency</td>
<td colspan="4" width="270">50/60Hz</td>
</tr>
<tr>
<td width="186">Max. AC output current</td>
<td width="68">5A</td>
<td width="68">7.5A</td>
<td width="68">10A</td>
<td width="68">13.6A</td>
</tr>
<tr>
<td width="186">Adjustable displacement power factor</td>
<td colspan="4" width="270">0.8 ind    0.8 cap</td>
</tr>
<tr>
<td width="186">Harmonic distortion (THD) at Pac.r</p>
<p>General Data</td>
<td colspan="4" width="270">&lt; 3%</td>
</tr>
<tr>
<td width="186"></td>
<td colspan="4" width="270"></td>
</tr>
<tr>
<td width="186">Dimensions (W x H x D)</td>
<td colspan="4" width="270">320×264×94mm</td>
</tr>
<tr>
<td width="186">Weight</td>
<td colspan="4" width="270">6.5kg</p>
<p>&lt; 25dB(A)@1m</td>
</tr>
<tr>
<td width="186">Noise emission (typical)</td>
<td colspan="4" width="270"></td>
</tr>
<tr>
<td width="186">DC connection</td>
<td colspan="4" width="270">Plug-in DC connector</td>
</tr>
<tr>
<td width="186">AC connection</td>
<td colspan="4" width="270">Plug-in AC connector</td>
</tr>
<tr>
<td width="186">Communication</td>
<td colspan="4" width="270">GPRS/WiFi , RS485(Optional)</td>
</tr>
<tr>
<td width="186">Display</td>
<td colspan="4" width="270">LED</td>
</tr>
<tr>
<td width="186">Mounting</td>
<td colspan="4" width="270">Wall mounting</td>
</tr>
<tr>
<td width="186">Cooling</td>
<td colspan="4" width="270">Convection</td>
</tr>
<tr>
<td width="186">Operating temperature range</td>
<td colspan="4" width="270">-25…+60℃</td>
</tr>
<tr>
<td width="186">Relative  humidity  (non-condensing)</td>
<td colspan="4" width="270">4000m(           0…100%                  )</td>
</tr>
<tr>
<td width="186">Max. operating altitude</td>
<td colspan="4" width="270">Derating above 3000m</td>
</tr>
<tr>
<td width="186">Degree of protection</td>
<td colspan="4" width="270">IP65</td>
</tr>
<tr>
<td width="186">Climate Category</td>
<td colspan="4" width="270">4K4H</td>
</tr>
<tr>
<td width="186">Topology</td>
<td colspan="4" width="270">Transformerless</td>
</tr>
</tbody>
</table>
<h4>XI.Contact</h4>
<p>If you have any technical problems with our products, please contact our service. We require the following information in order to provide you with the necessary  assistance:</p>
<p>-Inverterdevice type<br />
-Inverterserialnumber<br />
Type and number of connected PV modules<br />
-Error code<br />
-Mounting location<br />
-Warrantycard<br />
AISWEI New Energy Technology(Jiangsu)Co., Ltd.  Tel.: +865126937  0998Fax: +86 5126937 3159<br />
<a href="mailto:service.china@aiswei-tech.com">Web: service.china@aiswei tech.com</a><br />
Add.: Building 9, No. 198 Xiangyang Road, Suzhou, China</p>
<p>AISWEI Pty Ltd.</p>
<p>Tel.: +61 3909 88674 Add.: Level 40, 140 William Street, Melbourne VIC 3000</p>
<p>AISWEI B.V. Add.: Muiderstraat 9/G, 1011 PZ Amsterdam North Holland, Netherlands</p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/37-46.webp" /></p>
<p><a href="http://www.aisweicloud.com/data/download.jsp" target="_blank" rel="noopener">http://www.aisweicloud.com/data/download.jsp</a></p>
<form id="commentform" class="comment-form" action="https://manuals.plus/wp-comments-post.php" method="post" novalidate="">
<p class="form-submit">
</form>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>

<!--
Performance optimized by W3 Total Cache. Learn more: https://www.boldgrid.com/w3-total-cache/

Page Caching using Disk: Enhanced 

Served from: usemanuals.com @ 2026-06-13 02:05:02 by W3 Total Cache
-->