<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Sika &#8211; UseManuals</title>
	<atom:link href="http://usemanuals.com/sika/feed/" rel="self" type="application/rss+xml" />
	<link>https://usemanuals.com</link>
	<description>Owner&#039;s manuals for all sorts of products</description>
	<lastBuildDate>Fri, 28 Apr 2023 05:47:43 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.7.2</generator>

<image>
	<url>https://usemanuals.com/wp-content/uploads/2025/02/favicon-32x32-2.png</url>
	<title>Sika &#8211; UseManuals</title>
	<link>https://usemanuals.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Sika AnchorFix-2 manual</title>
		<link>https://usemanuals.com/sika/anchorfix-2/</link>
		
		<dc:creator><![CDATA[ItsManual]]></dc:creator>
		<pubDate>Fri, 28 Apr 2023 05:47:43 +0000</pubDate>
				<category><![CDATA[Sika]]></category>
		<guid isPermaLink="false">https://usemanuals.com/?p=95676</guid>

					<description><![CDATA[&#160; Sika® AnchorFix-2 SUPER STRENGTH, TWO COMPONENT ADHESIVE ANCHORING SYSTEM PRODUCT DESCRIPTION Sika® AnchorFix-2 adhesive anchor system is solvent/styrene free, epoxy acrylate based, and has been specifically formulated as a high performance, two component adhesive anchor system for threaded bars in uncracked concrete. USES Sika® AnchorFix-2 may only be used by experienced professionals. As a fast curing anchoring adhesive for all grades of: Rebars / reinforcing steel Threaded rods Bolts and special fastening systems In the following substrates: Concrete Solid masonry Steel Hard natural stone* Solid rock* * These substrates may vary greatly, in particular with regard to strength, composition and porosity. Therefore, for each application the suitability of Sika® AnchorFix-2 Adhesive must be tested by first applying the Product only to a sample area. Check in particular bond strength, surface staining and discoloration. CHARACTERISTICS / ADVANTAGES Fast curing Standard guns can be used High load capacity Drinking Water certified Non-sag, even overhead Styrene-free epoxy acrylate Low wastage Fixing close to free edges. Versatile range of embedment depths. Anchoring without expansion forces. APPROVALS / STANDARDS EESR to AC308 by ICC-ES PENDING. ESR to AC308 by IAPMO-UES. Certified to ANSI / NSF – 61 by UL. PRODUCT INFORMATION TECHNICAL INFORMATION Tensile Adhesion Strength Service Temperature Design Considerations SYSTEM INFORMATION System Structure APPLICATION INFORMATION Mixing Ratio Component A : component B = 10 : 1 by volume Coverage Sag Flow Non-sag, even overhead Product Temperature Sika® AnchorFix-2 must be at a temperature of between 41 °F (5 °C) to 68 °F (20 °C) for application. Dew Point Beware of condensation. Beware of frost. Open Time APPLICATION INSTRUCTIONS SUBSTRATE QUALITY Mortar and concrete must be older than 28 days. Substrate strength (concrete, masonry, natural stone) must be verified. Pull-out tests must be carried out if the substrate strength is unknown. The anchor hole must always be clean, dry, free from oil and grease etc. Loose particles must be removed from the holes. Threaded rods and rebars have to be cleaned thoroughly from any oil, grease or any other substances and particles such as dirt etc. MIXING Getting the cartridge ready 1. Unscrew the cap 2. Cut the film 3. Screw on the static mixer 4. Place the cartridge into the gun and start application When the work is interrupted the static mixer can remain on the cartridge after the gun pressure has been relieved. If the resin has hardened in the nozzle when work is resumed, a new nozzle must be attached. APPLICATION METHOD / TOOLS Anchors in solid masonry/concrete: Drilling of hole with an electric drill to the diameter and depth required. Drill hole diameter must be in accordance with anchor size. The drill hole must be cleaned with a blow pump or by compressed air, starting from the bottom of the hole. (at least 2×) Important: use oil-free compressors. The drill hole must be thoroughly cleaned with the special steel brush (brush at least 2×). The diameter of the brush must be larger than the diameter of the drill hole. The drill hole must be cleaned with a blow pump or by compressed air, starting from the bottom of the hole (at least 2×). Important: use oil-free compressors. The drill hole must be thoroughly cleaned with the special steel brush (brush at least 2×). The diameter of the brush must be larger than the diameter of the drill hole. The drill hole must be cleaned with a blow pump or by compressed air, starting from the bottom of the hole (at least 2×). Important: use oil-free compressors. Pump approx. twice until both parts come out uniformly. Do not use this material. Release the gun pressure and clean the cartridge opening with a cloth. Inject the adhesive into the hole, starting from the bottom, while slowly drawing back the static mixer. In any case avoid entrapping air. For deep holes extension tubing can be used. Insert the anchor with a rotary motion into the filled drill hole. Some adhesive must come out of the hole. Important: the anchor must be placed within the open time. During the resin hardening time the anchor must not be moved or loaded. Wash tools immediately with Sika® Colma Cleaner. Wash hands and skin thoroughly with warm soap water. CLEANING OF TOOLS Tools must be cleaned as soon as possible with a clean rag. BASIS OF PRODUCT DATA Results may differ based upon statistical variations depending upon mixing methods and equipment, temperature, application methods, test methods, actual site conditions and curing conditions. OTHER RESTRICTIONS See Legal Disclaimer. ENVIRONMENTAL, HEALTH AND SAFETY For further information and advice regarding transportation, handling, storage and disposal of chemical products, user should refer to the actual Safety Data Sheets containing physical, environmental, toxicological and other safety related data. User must read the current actual Safety Data Sheets before using any products. In case of an emergency, call CHEMTREC at 1-800-424-9300, International 703-527-3887. LEGAL DISCLAIMER KEEP CONTAINER TIGHTLY CLOSED KEEP OUT OF REACH OF CHILDREN NOT FOR INTERNAL CONSUMPTION FOR INDUSTRIAL USE ONLY FOR PROFESSIONAL USE ONLY Prior to each use of any product of Sika Corporation, its subsidiaries or affiliates (“SIKA”), the user must always read and follow the warnings and instructions on the product’s most current product label, Product Data Sheet and Safety Data Sheet which are available at usa.sika.com or by calling SIKA’s Technical Service Department at 1-800-933-7452. Nothing contained in any SIKA literature or materials relieves the user of the obligation to read and follow the warnings and instructions for each SIKA product as set forth in the current product label, Product Data Sheet and Safety Data Sheet prior to use of the SIKA product. SIKA warrants this product for one year from date of installation to be free from manufacturing defects and to meet the technical properties on the current Product Data Sheet if used as directed within the product’s shelf life. User determines suitability of product for intended use and assumes all risks. User’s and/or buyer’s sole remedy shall be limited to the purchase price or replacement of this product exclusive of any labor costs. NO OTHER WARRANTIES EXPRESS OR IMPLIED SHALL APPLY INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SIKA SHALL NOT BE LIABLE UNDER ANY LEGAL THEORY FOR SPECIAL OR CONSEQUENTIAL DAMAGES. SIKA SHALL NOT BE RESPONSIBLE FOR THE USE OF THIS PRODUCT IN A MANNER TO INFRINGE ON ANY PATENT OR ANY OTHER INTELLECTUAL PROPERTY RIGHTS HELD BY OTHERS. Sale of SIKA products are subject to the Terms and Conditions of Sale which are available at https://usa.sika.com/en/group/SikaCorp/termsandconditions.html or by calling 1-800-933-7452. [...]<p><a class="btn btn-secondary understrap-read-more-link" href="https://usemanuals.com/sika/anchorfix-2/">Read More...</a></p>]]></description>
										<content:encoded><![CDATA[<p>&nbsp;</p>
<h3>Sika® AnchorFix-2</h3>
<p>SUPER STRENGTH, TWO COMPONENT ADHESIVE ANCHORING SYSTEM</p>
<h4>PRODUCT DESCRIPTION</h4>
<p>Sika® AnchorFix-2 adhesive anchor system is solvent/styrene free, epoxy acrylate based, and has been specifically formulated as a high performance, two component adhesive anchor system for threaded bars in uncracked concrete.</p>
<h4>USES</h4>
<p>Sika® AnchorFix-2 may only be used by experienced professionals.</p>
<p><strong>As a fast curing anchoring adhesive for all grades of:</strong></p>
<ul>
<li>Rebars / reinforcing steel</li>
<li>Threaded rods</li>
<li>Bolts and special fastening systems</li>
</ul>
<p><strong>In the following substrates:</strong></p>
<ul>
<li>Concrete</li>
<li>Solid masonry</li>
<li>Steel</li>
<li>Hard natural stone*</li>
<li>Solid rock*</li>
</ul>
<p>* These substrates may vary greatly, in particular with regard to strength, composition and porosity. Therefore, for each application the suitability of Sika® AnchorFix-2 Adhesive must be tested by first applying the Product only to a sample area. Check in particular bond strength, surface staining and discoloration.</p>
<h4>CHARACTERISTICS / ADVANTAGES</h4>
<ul>
<li>Fast curing</li>
<li>Standard guns can be used</li>
<li>High load capacity</li>
<li>Drinking Water certified</li>
<li>Non-sag, even overhead</li>
<li>Styrene-free epoxy acrylate</li>
<li>Low wastage</li>
<li>Fixing close to free edges.</li>
<li>Versatile range of embedment depths.</li>
<li>Anchoring without expansion forces.</li>
</ul>
<h4>APPROVALS / STANDARDS</h4>
<ul>
<li>EESR to AC308 by ICC-ES PENDING.</li>
<li>ESR to AC308 by IAPMO-UES.</li>
<li>Certified to ANSI / NSF – 61 by UL.</li>
</ul>
<h4>PRODUCT INFORMATION</h4>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/04/PRODUCT-INFORMATION-1.webp" /></p>
<h4>TECHNICAL INFORMATION</h4>
<p><strong>Tensile Adhesion Strength</strong></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/04/Tensile-Adhesion-Strength.png" /></p>
<p><strong>Service Temperature</strong></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/04/Service-Temperature-1.png" /></p>
<p><strong>Design Considerations</strong></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/04/Design-Considerations.png" /></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/04/Design-Considerations-1.png" /></p>
<h4>SYSTEM INFORMATION</h4>
<p><strong>System Structure</strong></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/04/System-Structure.png" /></p>
<h4>APPLICATION INFORMATION</h4>
<p><strong>Mixing Ratio</strong></p>
<p>Component A : component B = 10 : 1 by volume</p>
<p><strong>Coverage</strong></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/04/Coverage-1.png" /></p>
<p><strong>Sag Flow</strong></p>
<p>Non-sag, even overhead</p>
<p><strong>Product Temperature</strong></p>
<p>Sika® AnchorFix-2 must be at a temperature of between 41 °F (5 °C) to 68 °F (20 °C) for application.</p>
<p><strong>Dew Point</strong></p>
<ul>
<li>Beware of condensation.</li>
<li>Beware of frost.</li>
</ul>
<p><strong>Open Time</strong></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/04/Open-Time-1.png" /></p>
<h4>APPLICATION INSTRUCTIONS</h4>
<h5>SUBSTRATE QUALITY</h5>
<p>Mortar and concrete must be older than 28 days. Substrate strength (concrete, masonry, natural stone) must be verified. Pull-out tests must be carried out if the substrate strength is unknown. The anchor hole must always be clean, dry, free from oil and grease etc. Loose particles must be removed from the holes. Threaded rods and rebars have to be cleaned thoroughly from any oil, grease or any other substances and particles such as dirt etc.</p>
<h5>MIXING</h5>
<p>Getting the cartridge ready</p>
<p><strong>1.</strong> Unscrew the cap</p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/04/MIXING-1-1.png" /></p>
<p><strong>2.</strong> Cut the film</p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/04/MIXING-2-1.png" /></p>
<p><strong>3.</strong> Screw on the static mixer</p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/04/MIXING-3-1.png" /></p>
<p><strong>4.</strong> Place the cartridge into the gun and start application</p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/04/MIXING-4-1.png" /></p>
<p>When the work is interrupted the static mixer can remain on the cartridge after the gun pressure has been relieved. If the resin has hardened in the nozzle when work is resumed, a new nozzle must be attached.</p>
<h5>APPLICATION METHOD / TOOLS</h5>
<p><strong>Anchors in solid masonry/concrete:</strong></p>
<p>Drilling of hole with an electric drill to the diameter and depth required. Drill hole diameter must be in accordance with anchor size.</p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/04/Application-1-1.png" /></p>
<p>The drill hole must be cleaned with a blow pump or by compressed air, starting from the bottom of the hole. (at least 2×) Important: use oil-free compressors.</p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/04/Application-2-1.png" /></p>
<p>The drill hole must be thoroughly cleaned with the special steel brush (brush at least 2×). The diameter of the brush must be larger than the diameter of the drill hole.</p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/04/Application-3-1.png" /></p>
<p>The drill hole must be cleaned with a blow pump or by compressed air, starting from the bottom of the hole (at least 2×). Important: use oil-free compressors.</p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/04/Application-2-1.png" /></p>
<p>The drill hole must be thoroughly cleaned with the special steel brush (brush at least 2×). The diameter of the brush must be larger than the diameter of the drill hole.</p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/04/Application-3-1.png" /></p>
<p>The drill hole must be cleaned with a blow pump or by compressed air, starting from the bottom of the hole (at least 2×). Important: use oil-free compressors.</p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/04/Application-2-1.png" /></p>
<p>Pump approx. twice until both parts come out uniformly. Do not use this material. Release the gun pressure and clean the cartridge opening with a cloth.</p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/04/Application-4-1.png" /></p>
<p>Inject the adhesive into the hole, starting from the bottom, while slowly drawing back the static mixer. In any case avoid entrapping air. For deep holes extension tubing can be used.</p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/04/Application-5-1.png" /></p>
<p>Insert the anchor with a rotary motion into the filled drill hole. Some adhesive must come out of the hole.<br />
Important: the anchor must be placed within the open time.</p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/04/Application-6-1.png" /></p>
<p>During the resin hardening time the anchor must not be moved or loaded. Wash tools immediately with Sika® Colma Cleaner. Wash hands and skin thoroughly with warm soap water.</p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/04/Application-7-1.png" /></p>
<h5>CLEANING OF TOOLS</h5>
<p>Tools must be cleaned as soon as possible with a clean rag.</p>
<h4>BASIS OF PRODUCT DATA</h4>
<p>Results may differ based upon statistical variations depending upon mixing methods and equipment, temperature, application methods, test methods, actual site conditions and curing conditions.</p>
<h4>OTHER RESTRICTIONS</h4>
<p>See Legal Disclaimer.</p>
<h4>ENVIRONMENTAL, HEALTH AND SAFETY</h4>
<p>For further information and advice regarding transportation, handling, storage and disposal of chemical products, user should refer to the actual Safety Data Sheets containing physical, environmental, toxicological and other safety related data. User must read the current actual Safety Data Sheets before using any products. In case of an emergency, call CHEMTREC at 1-800-424-9300, International 703-527-3887.</p>
<h4>LEGAL DISCLAIMER</h4>
<ul>
<li><strong>KEEP CONTAINER TIGHTLY CLOSED</strong></li>
<li><strong>KEEP OUT OF REACH OF CHILDREN</strong></li>
<li><strong>NOT FOR INTERNAL CONSUMPTION</strong></li>
<li><strong>FOR INDUSTRIAL USE ONLY</strong></li>
<li><strong>FOR PROFESSIONAL USE ONLY</strong></li>
</ul>
<p>Prior to each use of any product of Sika Corporation, its subsidiaries or affiliates (“SIKA”), the user must always read and follow the warnings and instructions on the product’s most current product label, Product Data Sheet and Safety Data Sheet which are available at usa.sika.com or by calling SIKA’s Technical Service Department at 1-800-933-7452. Nothing contained in any SIKA literature or materials relieves the user of the obligation to read and follow the warnings and instructions for each SIKA product as set forth in the current product label, Product Data Sheet and Safety Data Sheet prior to use of the SIKA product.</p>
<p>SIKA warrants this product for one year from date of installation to be free from manufacturing defects and to meet the technical properties on the current Product Data Sheet if used as directed within the product’s shelf life. User determines suitability of product for intended use and assumes all risks. User’s and/or buyer’s sole remedy shall be limited to the purchase price or replacement of this product exclusive of any labor costs.</p>
<p><strong>NO OTHER WARRANTIES EXPRESS OR IMPLIED SHALL APPLY INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SIKA SHALL NOT BE LIABLE UNDER ANY LEGAL THEORY FOR SPECIAL OR CONSEQUENTIAL DAMAGES. SIKA SHALL NOT BE RESPONSIBLE FOR THE USE OF THIS PRODUCT IN A MANNER TO INFRINGE ON ANY PATENT OR ANY OTHER INTELLECTUAL PROPERTY RIGHTS HELD BY OTHERS.</strong></p>
<p>Sale of SIKA products are subject to the Terms and Conditions of Sale which are available at https://usa.sika.com/en/group/SikaCorp/termsandconditions.html or by calling 1-800-933-7452.</p>
<form id="commentform" class="comment-form" action="https://manuals.plus/wp-comments-post.php" method="post" novalidate="">
<p class="form-submit"><input id="comment_post_ID" name="comment_post_ID" type="hidden" value="42707" /><br />
<input id="comment_parent" name="comment_parent" type="hidden" value="0" /></p>
</form>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>

<!--
Performance optimized by W3 Total Cache. Learn more: https://www.boldgrid.com/w3-total-cache/

Page Caching using Disk: Enhanced 

Served from: usemanuals.com @ 2026-08-27 13:01:55 by W3 Total Cache
-->