Sanitas – UseManuals https://usemanuals.com Owner's manuals for all sorts of products Wed, 19 Jul 2023 11:01:44 +0000 en-US hourly 1 https://wordpress.org/?v=6.7.2 https://usemanuals.com/wp-content/uploads/2025/02/favicon-32x32-2.png Sanitas – UseManuals https://usemanuals.com 32 32 Sanitas SFT 40 Thermometer Manual https://usemanuals.com/sanitas/sft-40-thermometer/ Sat, 08 Jul 2023 14:41:00 +0000 https://usemanuals.com/?p=147594 Read More...

]]>
INSTRUCTION MANUAL

Forehead contact thermometer
Model: SFT 40

Please read these instructions for use carefully and observe the information they contain.

1. Safety notes

1.1 Risks to the user

  • Only use the device once you have read and understood these instructions for use.
  • Retain these instructions for use. The instructions for use must be accessible to all users. All instructions must be followed.
  • The device is only intended for the purpose stated in these instructions for use.
  • Children must not be allowed to use the device. Medical products are not toys.
  • Do not use the device if it is damaged or if error messages appear in the display.
  • The device has been designed for practical use, but is not a substitute for a visit to the doctor.
  • This device is not intended for commercial or clinical use.
  • Should you have any questions about using the device, please contact either your retailer or Customer Services.
  • Do not open the device, except to replace the batteries.
  • Clean the device after every use. Cleaning the device 8. Cleaning and maintenance.

1.2 Risks to the device

  • Do not subject the device to mechanical impacts.
  • Do not expose the device to direct sunlight.
  • Do not expose the device to liquids. The device is not waterproof. Avoid all direct contact with water or other liquids.
  • Have the device repaired by authorised service centres only, otherwise its warranty is invalidated.
  • Portable and mobile HF communication systems may interfere with this device. For more details, please contact Customer Services at the address indicated.

1.3 Usage instructions

  • Measure the temperature exclusively at the temple artery between the end of the eyebrow and the hairline.
  • Use the thermometer only on dry, clean skin; wipe away any perspiration with a dry cloth.
  • Keep hair away from the measuring area, and use only on bare skin.
  • Do not use on scars, irritated skin, open wounds or grazes.
  • Do not use if the skin has been warmed or cooled by sunlight, open fi res, the fl ow of air from air-conditioning systems or cold/warm compresses.
  • Wait at least 2 minutes between 2 successive measurements, so that the device can adjust back to room temperature.
  • If the device is stored outside the operating temperature (see Technical data), it must be allowed to adjust to room temperature before the measurement is taken. We therefore recommend storing the device in living spaces to ensure immediate operational readiness.

2. Information about this thermometer
The temperature measurement varies depending on the part of the body where the measurement is taken. In a healthy person, the variance can be between 0.4°F – 1.8°F (0.2 °C – 1 °C) in different parts of the body.

Normal temperature range with various thermometers

Normal temperature range with various thermometers

Tip

  • Temperatures measured with diff erent thermometers should never be compared with one another.
  • Tell your doctor what type of thermometer you used to take your temperature and in what part of the body. Also bear this in mind if you are diagnosing yourself.

Influences on body temperature

• A person’s individual metabolism
• Age
Body temperature is higher in babies and toddlers than in adults. Greater temperature fl uctuations occur faster and more often in children. Normal body temperature decreases with age.
• Clothing
• Ambient temperature
• Time of day
Body temperature is lower in the morning and increases throughout the day towards evening.
• Activities
Physical and, to a lesser extent, mental activities increase body temperature.

Tip
Taking the body temperature provides a current measurement of a person’s temperature. If you are uncertain about interpreting the results or if the values are abnormal (e.g. fever), please consult your doctor. This also applies in the case of slight temperature changes if there are other symptoms of illness such as agitation, severe sweating, fl ushed skin, fast pulse rate, tendency to collapse, etc.

3. Unit description

Unit description

1. Measuring sensor
2. Display
3. On/Off button
4. Battery compartment (rear)

4. Measuring temperature

Press the On/Off button. A beep is output. All segments in the display light up.

The result of the previous measurement is shown in the display for approx. 2 seconds.

Wait until the measured value and the hourglass symbol have disappeared from the display. 2 beeps indicate that the thermometer is ready to take a measurement. Do not begin measuring until both beeps have been output.

Hold the measuring sensor of the thermometer in the centre of the temple between the eyesocket and the hairline. Correct placement and good skin contact are the prerequisites for reliable measuring values!

The measurement starts automatically as soon as the measuring sensor is placed at the measuring point. A status bar indicates that the measurement is in progress.

To avoid falsifying the measuring result, it is important to remain still during the measurement and not to move the thermometer!

After approx. 6-8 seconds, a long beep is output and the measuring result is shown in the display. After 1 minute, the device switches off automatically. You can also switch off the thermometer manually by pressing the On/Off button.

5. Setting the measurement unit
The thermometer can display the temperature in both degrees Celsius (°C) and degrees Fahrenheit (°F). To switch between these measurement units, proceed as follows with the device switched off :
Press and hold the On/Off button until the device switches from °C to °F or vice versa.

6. Error messages

7. Batteries
The device requires two AAA (LR03) batteries.

  • Open the battery compartment. For this purpose, slide down the battery compartment lid on the back.
  • Take the used batteries out of the battery compartment.
  • Insert new batteries. Make sure that the batteries are inserted the right way round.
  • Close the battery compartment. The battery compartment lid must engage audibly.
  • Remove the batteries from the device if you do not intend to use it for longer periods, so that the thermometer cannot be damaged by leaking batteries.

Used batteries should not be disposed of in normal household waste. You are legally required to dispose of the batteries. Dispose of them via your electronics retailer or your local recycling point. Notes: The codes below are printed on batteries containing harmful substances: Pb = Battery contains lead, Cd = Battery contains cadmium, Hg = Battery contains mercury. The batteries in this device do not contain any pollutants.

8. Cleaning and maintenance

Clean the measuring head and the sensor with an alcohol swab (available from pharmacies) or with a cotton cloth soaked in 70% isopropyl alcohol.
Make sure that no liquid penetrates into the interior of the thermometer. Clean the housing with a dry cloth. Do not use any abrasive cleaning agents, thinners or benzene, and never immerse the device in water or other cleaning liquids.
After cleaning, please wait 2 minutes before taking a measurement, so that the thermometer can adjust back to room temperature.

9. Storing the device

The device must not be stored or used at an excessively high or low temperature or humidity (see technical specifi cations), in sunlight, in association with an electrical current or in dusty locations. Otherwise inaccuracies can occur.
If prolonged storage is planned, you should remove the batteries. The device must be tested for accuracy (calibrated) after 3 years. For this, please send the complete device to the retailer’s or the service address.

10. Disposing of the device

Dispose of the device in accordance with EC Directive 2002/96/EC – WEEE (Waste Electrical and Electronic Equipment). If you have any questions, please contact the local authorities responsible for waste disposal.

11. Technical data
If the device is used other than in accordance with the specifi cations, perfect functioning cannot be guaranteed! We reserve the right to make technical changes to improve and develop the product.

12. Guidelines

  • This device complies with the EU Directive 93/42 EEC.
  • This device complies with ASTM E 1112.
  • This device complies with European Standard EN60601-1-2 and is subject to particular precautions with regard to electromagnetic compatibility.

13. Included in delivery

  • Thermometer
  • 2 x AAA (LR03) batteries
  • Instructions for use
]]>
SANITAS SIL 06/SIL16 Infrared Lamp Manual https://usemanuals.com/sanitas/sil-06-lamp/ Wed, 19 Jul 2023 11:01:44 +0000 https://usemanuals.com/?p=167484 Read More...

]]>
SANITAS SIL 06/SIL 16 Infrared Lamp Instruction for Use

1. About the infrared lamp

Application

This infrared lamp is only intended for radiating the human body.

Infrared radiation causes warmth to be transported to the human body. The blood supply in the radiated skin is increased and the metabolic turnover in the field of temperature enhanced. The mode of action of the infrared light encourages the body to heal; healing processes are thus assisted in a specific area.

Infrared light can be used as a parallel treatment in diseases of the ear, nose and throat and to assist in facial and beauty care, especially in case of impure skin.

However, first ask your family doctor whether application in the individual case is advisable from a medical standpoint.

Included in delivery:

  • Infrared lamp
  • Protective eyewear
  • These operating instructions

Note: Warranty restriction
The infrared bulb included – as with all light sources – is not subject to the warranty.

2. Signs and symbols

The following symbols appear in these instructions or on the device.

3. Notes

Please read these instructions for use carefully and keep them for later use, be sure to make them accessible to other users and observe the information they contain.

Safety notes

Warning

  • This infrared lamp is only intended for radiating the human body.
  • Always use the protective eyewear supplied during usage.
  • Before use, ensure that all packaging materials are removed and that there is no visible damage to the unit or accessories. When in doubt, do not use the unit and contact your dealer or the customer service address provided.
  • Always ensure that the appliance is on a secure and even surface.
  • The lamp housing and the infrared lamp become very hot during operation. There is a risk of burning if these are touched. Always let the lamp cool down first before touching it.
  • Inflammable objects must be kept at a distance of at least 1.0 m from the infrared lamp. Do not hang the appliance on the wall or from the ceiling.
  • Connect the unit only to the mains voltage listed on the type plate.
  • Do not dip the unit into water and do not use it in wet rooms.
  • This device is not intended for use by persons (including children) with restricted physical, sensory or mental capabilities and/or by persons lacking the required understanding of the equipment and how it is used, unless they are supervised by a person who is responsible for their safety or they are given instructions on how to use the device.
  • Do not use on babies and small children.
  • Children should be supervised to ensure that they do not use the device as a toy.
  • This device is not intended for use on changing units, cots or similar.
  • Do not use it on persons sensitive to heat. The sensitivity to heat can be reduced or increased in the following cases:
    – diabetic patients
    – persons with sleepiness, dementia or difficulties concentrating
    – persons with illness-related skin changes or persons with scarred skin areas in the application area
    – persons with allergies
    – children and older persons
    – after consuming medications or alcohol
  • Do not operate the device if you are wearing an implant, particularly if it is located in the area of the body to be treated. If you have any doubts, consult your doctor.
  • If you are pregnant, do not operate the device near your abdomen, in order to prevent this area from overheating. If you have any doubts, consult your doctor.
  • In case of acutely inflammatory processes, radiation should only be carried out after consulting a doctor.
  • Always limit the period of use and check the reaction of the skin.
  • Medications, cosmetics or food can lead to a over-sensitive or allergic reaction of the skin under certain conditions. Radiation must be ended immediately in this case.
  • An appropriate distance between the infrared lamp and the desired treatment area must be maintained during treatment so that no skin irritation, such as tingling, itching, burning or too high heat sensitivity occurs. Stop the treatment if this occurs. Alternatively, increase the radiation distance and/or reduce the radiation duration.
  • This device is not intended for radiation from above.
  • The minimum distances described in these instructions for use must be adhered to.
  • If the appliance is operated continuously, caution and attention are advisable – never fall asleep during radiation!
  • Prolonged use can cause burns to the skin.
  • Do not touch the infrared lamp or unscrew it when it is connected to the mains.
  • Children do not understand the risks associated with electrical appliances. Make sure the appliance is not used by children without appropriate supervision.
  • The appliance may be used only under supervision.
  • Keep children away from packaging materials (risk of suffocation).
  • Do not cover up or pack away the unit while it is warm.
  • Always remove the mains plug and let the unit cool off before you touch it.
  • Do not touch the unit with wet hands while it is plugged in; do not allow any water to be sprayed onto the unit. The unit must be operated only when it is completely dry.
  • Protect the unit from strong impacts.
  • Do not pull the mains plug from the socket by the cord.
  • In the event of a defect or malfunction, switch the device off immediately and disconnect it from the power supply.
    If the power cord of the device is damaged, it must be replaced by the manufacturer or an authorised customer service technician in order to avoid hazard.
  • Disconnection from the mains supply is only guaranteed if the mains plug has been removed from the socket.
  • There is a risk of strangulation for babies and children who become trapped in the mains cable.

General notes

Important

  • Do not open the device. Please do not attempt to repair the unit yourself. This could result in serious injuries. Failure to observe this regulation shall void the warranty.
  • If you need to have the unit repaired, contact customer service or an authorised dealer.

4. Initial use

Setup

Remove the unit from the packaging. Remove all packaging material before using the appliance. Before use, check whether the infrared lamp is properly screwed in. Place the device on flat surfaces. The appliance has an adjustable lampshade. Set the angle of the fluorescent screen in accordance with your individual requirements.

Mains connection

Connect the unit only to the mains voltage listed on the type plate.

Note:

  • Ensure that there is a socket near the place where the lamp will stand.
  • Lay the mains cable in such a way that no one can trip over it.

5. Operation

  1. Switching on the lamp
    • Push the plug completely into the mains socket.
  2. Enjoying the light
    The recommended duration of treatment is maximum 12 minutes. We recommend selecting a shorter radiation period to start with. However, the skin of some people may show an over-sensitive (e.g. with extreme redness, blistering, itching, heavy sweating) or allergic reaction to heat radiation, even when the lamp is used correctly. If symptoms are not relieved after 6 to 8 applications, stop using the device and consult your doctor.
  3. Important instructions
    The distance between the infrared lamp and the radiated part of the body should not be less than the following:
    SIL 06: at least 24 in (60 cm)
    SIL 16: at least 32 in (80 cm)
    Always use the protective eyewear supplied during usage. The protective eyewear corresponds to the requirements of EN 171:2002 and serves to protect the eyes.
    CAUTION: Never look directly into the infrared light without protective eyewear.
    Basically,
    examine the radiated section of the body regularly. Discontinue radiation immediately if any signs of an over-sensitive or allergic reaction appear and consult a physician.
  4. Switching off the lamp
    • Pull the mains plug from the socket.
      CAUTION!
      The lamp is hot after being used. Let the lamp cool off first long enough before you put it away and/or pack it up! Please note that the mains cable must not be wound round the infrared lamp either for storage or when in use.

6. Changing the infrared lamp

The device must be switched off and allowed to cool and the mains plug pulled out before cleaning and changing the infrared heat lamp.

Please note that only infrared lamps of the original type may be used as replacements.

Warning

  • Do not touch the infrared lamp or unscrew it when it is connected to the mains.
  • Unplug the device, to avoid the risk of electrocution.
  • In the interest of environmental protection, do not dispose of the device in household waste.

7. Cleaning and care of the unit

The unit should be cleaned occasionally.

Important

To avoid odours caused by fluff and dust, we recommend regularly cleaning the device as follows:

  • The device must be switched off and allowed to cool and the mains plug pulled out before cleaning and changing the infrared heat lamp.
  • Ensure that no water penetrates inside the unit!
  • Do not wash the unit in a washing machine! Clean using a damp cloth, to which you can apply a little detergent if necessary.
  • Do not touch the unit with wet hands while it is plugged in; do not allow any water to be sprayed onto the unit. The unit must be operated only when it is completely dry.
  • Do not use abrasive detergents and never immerse the unit in water.

8. Disposal

In the interest of protecting the environment, the unit must not be thrown out with the household waste at the end of its service life. Dispose of the unit at a suitable local collection or recycling point.

Please dispose of the device in accordance with EC Directive – WEEE (Waste Electrical and Electronic Equipment).

If you have any queries, please contact the appropriate local authorities.

9. Technical specifications

The serial number is located on the device or in the battery compartment.

Subject to technical modifications. This device meets the requirements of the European Medical Devices Directive 93/42/EEC with amendments as well as the German Medical Devices Act.

Hans Dinslage GmbH, Riedlinger Straße 28, 88524 Uttenweiler, Germany

www.sanitas-online.de

]]>