<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>RZ &#8211; UseManuals</title>
	<atom:link href="http://usemanuals.com/rz/feed/" rel="self" type="application/rss+xml" />
	<link>https://usemanuals.com</link>
	<description>Owner&#039;s manuals for all sorts of products</description>
	<lastBuildDate>Sun, 02 Jul 2023 10:16:25 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.7.2</generator>

<image>
	<url>https://usemanuals.com/wp-content/uploads/2025/02/favicon-32x32-2.png</url>
	<title>RZ &#8211; UseManuals</title>
	<link>https://usemanuals.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>RZ GM816 Measuring instrument Anemometer Manual</title>
		<link>https://usemanuals.com/rz/gm816-anemometer/</link>
		
		<dc:creator><![CDATA[ItsManual]]></dc:creator>
		<pubDate>Sun, 02 Jul 2023 10:16:25 +0000</pubDate>
				<category><![CDATA[RZ]]></category>
		<guid isPermaLink="false">https://usemanuals.com/?p=137553</guid>

					<description><![CDATA[RZ GM816 Measuring instrument Anemometer FUNCTION Air Velocity &#38; Temperature Measurement； Max/Average/Current air velocity measurement; ℃/℉ Temperature unit selection; Five units of air velocity: M/s, Km/h, ft/min, Knots, mph Beaufort scale; Backlight display; Manual/Auto power shut off; Wind chill indication; Low battery indication. LCD Display Operation Turn on: Press “MODE” button for 2 seconds to turn on the unit. LCD will display Air velocity, temperature and battery icon. LCD backlight will last for 12 seconds. Set unit of air velocity and measuring mode: Press “MODE” button more than 3 seconds until “m/s” starts to blink. Press “SET” button to select desired air velocity unit. To confirm the unit, press “MODE” button. For setting MAX/AVG/CU mode, press “SET” button again and again until CU/MAX/AVG blink, then press “MODE” button to confirm. The setting will be stored when turn off the unit. But if you change the battery, the setting will go back to the factory preset. Unit of Air velocity: m/s, Km/hr, ft/min, Knots, mph Measuring mode: CU: current air velocity MAX: max air velocity AVG: average air velocity Set temperature unit: Temperature switch key (℃/℉) conceal in the rear cabinet, please use a little push-pin to press the key for ℃/℉ conversion. Backlight display: The backlight will be activated for 12 seconds by press any key Measurement: when the wind vane (impeller) turns, LCD will instant display wind speed, temperature and. beaufort scale. When temperature below 0 ℃, “WIND CHIU” will be shown on the LCD. Turn off: Press “MODE” + “SET” buttons at the same time to turn off the unit. Auto power shut off: The unit will be shut off without any operation for 14 minutes Change battery: When the symbol ” ” shown on the LCD, please change the battery. Specification A. Air velocity Unit Range Resolution Threshold Accuracy M/s 0~30 0.1 0.1 ±5% Ft/min 0~5860 19 39 Knots 0~55 0.2 0.1 Km/hr 0~90 0.3 0.3 Mph 0~65 0.2 0.2 Temperature. B Unit Range Resolution Accuracy ℃ -10℃~+45℃ 0.2 ±2℃ °F 14°F~113°F 0.36 ±3.6°F Battery CR2032 3.0V (Included) Thermometer NTC thermometer Operating temperature -10℃~+45℃(14°F~113°F) Operating humidity Less than 90%RH Store temperature -40℃~+60℃(-40°F~140°F) Current consumption Approx. 3mA Weight 52g Dimension 40x18x105mm [...]<p><a class="btn btn-secondary understrap-read-more-link" href="https://usemanuals.com/rz/gm816-anemometer/">Read More...</a></p>]]></description>
										<content:encoded><![CDATA[<h3></h3>
<h4>RZ GM816 Measuring instrument Anemometer</h4>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/RZ-GM816-Measuring-instrument-Anemometer-119x300-1.webp" /></p>
<h4>FUNCTION</h4>
<ol>
<li>Air Velocity &amp; Temperature Measurement；</li>
<li>Max/Average/Current air velocity measurement;</li>
<li>℃/℉ Temperature unit selection;</li>
<li>Five units of air velocity:<br />
M/s, Km/h, ft/min, Knots, mph</li>
<li>Beaufort scale;</li>
<li>Backlight display;</li>
<li>Manual/Auto power shut off;</li>
<li>Wind chill indication;</li>
<li>Low battery indication.</li>
</ol>
<h4>LCD Display</h4>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/Display-300x195-1.webp" /></p>
<h4>Operation</h4>
<ol>
<li>Turn on: Press “MODE” button for 2 seconds to turn on the unit. LCD will display Air velocity, temperature and battery icon. LCD backlight will last for 12 seconds.</li>
<li>Set unit of air velocity and measuring mode:<br />
Press “MODE” button more than 3 seconds until “m/s” starts to blink. Press “SET” button to select desired air velocity unit. To confirm the unit, press “MODE” button. For setting MAX/AVG/CU mode, press “SET” button again and again until CU/MAX/AVG blink, then press “MODE” button to confirm.</p>
<ol>
<li>The setting will be stored when turn off the unit. But if you change the battery, the setting will go back to the factory preset.</li>
<li>Unit of Air velocity: m/s, Km/hr, ft/min, Knots, mph<br />
<strong>Measuring mode:</strong><br />
<strong>CU:</strong> current air velocity<br />
<strong>MAX:</strong> max air velocity<br />
<strong>AVG:</strong> average air velocity</li>
</ol>
</li>
<li><strong>Set temperature unit:</strong><br />
Temperature switch key (℃/℉) conceal in the rear cabinet, please use a little push-pin to press the key for ℃/℉ conversion.</li>
<li>Backlight display: The backlight will be activated for 12 seconds by press any key</li>
<li>Measurement: when the wind vane (impeller) turns, LCD will instant display wind speed, temperature and. beaufort scale. When temperature below 0 ℃, “WIND CHIU” will be shown on the LCD.</li>
<li>Turn off: Press “MODE” + “SET” buttons at the same time to turn off the unit.</li>
<li>Auto power shut off: The unit will be shut off without any operation for 14 minutes</li>
<li>Change battery: When the symbol ” ” shown on the LCD, please change the battery.</li>
</ol>
<h4>Specification</h4>
<table width="633">
<tbody>
<tr>
<td colspan="7" width="195"><strong>A. Air velocity</strong></td>
</tr>
<tr>
<td width="35">Unit</td>
<td colspan="2" width="34">Range</td>
<td colspan="2" width="38">Resolution</td>
<td width="35">Threshold</td>
<td width="53">Accuracy</td>
</tr>
<tr>
<td width="35">M/s</td>
<td colspan="2" width="34">0~30</td>
<td colspan="2" width="38">0.1</td>
<td width="35">0.1</td>
<td rowspan="5" width="53">±5%</td>
</tr>
<tr>
<td width="35">Ft/min</td>
<td colspan="2" width="34">0~5860</td>
<td colspan="2" width="38">19</td>
<td width="35">39</td>
</tr>
<tr>
<td width="35">Knots</td>
<td colspan="2" width="34">0~55</td>
<td colspan="2" width="38">0.2</td>
<td width="35">0.1</td>
</tr>
<tr>
<td width="35">Km/hr</td>
<td colspan="2" width="34">0~90</td>
<td colspan="2" width="38">0.3</td>
<td width="35">0.3</td>
</tr>
<tr>
<td width="35">Mph</td>
<td colspan="2" width="34">0~65</td>
<td colspan="2" width="38">0.2</td>
<td width="35">0.2</td>
</tr>
<tr>
<td colspan="7" width="195"><strong>Temperature. B</strong></td>
</tr>
<tr>
<td colspan="2" width="40">Unit</td>
<td colspan="2" width="47">Range</td>
<td colspan="2" width="54">Resolution</td>
<td width="53">Accuracy</td>
</tr>
<tr>
<td colspan="2" width="40">℃</td>
<td colspan="2" width="47">-10℃~+45℃</td>
<td colspan="2" width="54">0.2</td>
<td width="53">±2℃</td>
</tr>
<tr>
<td colspan="2" width="40">°F</td>
<td colspan="2" width="47">14°F~113°F</td>
<td colspan="2" width="54">0.36</td>
<td width="53">±3.6°F</td>
</tr>
<tr>
<td colspan="4" width="88">Battery</td>
<td colspan="3" width="107">CR2032 3.0V (Included)</td>
</tr>
<tr>
<td colspan="4" width="88">Thermometer</td>
<td colspan="3" width="107">NTC thermometer</td>
</tr>
<tr>
<td colspan="4" width="88">Operating temperature</td>
<td colspan="3" width="107">-10℃~+45℃(14°F~113°F)</td>
</tr>
<tr>
<td colspan="4" width="88">Operating humidity</td>
<td colspan="3" width="107">Less than 90%RH</td>
</tr>
<tr>
<td colspan="4" width="88">Store temperature</td>
<td colspan="3" width="107">-40℃~+60℃(-40°F~140°F)</td>
</tr>
<tr>
<td colspan="4" width="88">Current consumption</td>
<td colspan="3" width="107">Approx. 3mA</td>
</tr>
<tr>
<td colspan="4" width="88">Weight</td>
<td colspan="3" width="107">52g</td>
</tr>
<tr>
<td colspan="4" width="88">Dimension</td>
<td colspan="3" width="107">40x18x105mm</td>
</tr>
</tbody>
</table>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/RZ-logo-1.webp" /></p>
<form id="commentform" class="comment-form" action="https://manuals.plus/wp-comments-post.php" method="post" novalidate="">
<p class="form-submit">
</form>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>

<!--
Performance optimized by W3 Total Cache. Learn more: https://www.boldgrid.com/w3-total-cache/

Page Caching using Disk: Enhanced 

Served from: usemanuals.com @ 2026-09-06 09:22:03 by W3 Total Cache
-->