<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>OLUTRON &#8211; UseManuals</title>
	<atom:link href="http://usemanuals.com/olutron/feed/" rel="self" type="application/rss+xml" />
	<link>https://usemanuals.com</link>
	<description>Owner&#039;s manuals for all sorts of products</description>
	<lastBuildDate>Sat, 22 Jul 2023 17:34:36 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.7.2</generator>

<image>
	<url>https://usemanuals.com/wp-content/uploads/2025/02/favicon-32x32-2.png</url>
	<title>OLUTRON &#8211; UseManuals</title>
	<link>https://usemanuals.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>OLUTRON PD4-16-F Lighting Control Panels Manual</title>
		<link>https://usemanuals.com/olutron/pd4-16-f-lighting/</link>
		
		<dc:creator><![CDATA[ItsManual]]></dc:creator>
		<pubDate>Wed, 19 Jul 2023 11:14:36 +0000</pubDate>
				<category><![CDATA[OLUTRON]]></category>
		<guid isPermaLink="false">https://usemanuals.com/?p=167634</guid>

					<description><![CDATA[OLUTRON PD4-16-F Lighting Control Panels DIN Panels and Accessories The Lutron myRoom and HomeWorks families of DIN rail panels are designed to accept DIN Power Modules (DPMs). The DPMs can be configured in the panel to control multiple load types to fit the size, lighting plan and design of the space. Features Panels house up to four DIN Power Modules (DPMs) or up to three DIN Power Modules (DPMs) and one QSPS power supply. Compatible DPMs Digital Controllers LQSE-2ECO-D LQSE-2DAL-D Dimming MQSE-4A1-D MQSE-3A1-D MQSE-2A1-D LQSE-4A1-D LQSE-4T5-120-D QSNE-4T10-D LQSE-4T10-D Switching MQSE-4S1-D MQSE-3S1-D MQSE-2S1-D LQSE-4S5-230-D LQSE-4S8-120-D QSNE-4S10-D LQSE-4S10-D Power Supplies and Motor Controllers MQSPS-DH-1-30 (requires MQSPS-BRK) QSPS-DH-1-75-H LQSE-4M-D Feed-through panel. Panels extensively tested to ensure optimal thermal performance with maximum load in 32 °F to 104 °F (0 °C to 40 °C) ambient environment. Panels are rated for 120–240 V~ ULR, CE and non-CE applications. Models Available PD4-16-F 120–240 V~ Non-CE Line / Mains Voltage Enclosure PD4-16-F-CE 220–240 V~ CE Line / Mains Voltage Enclosure Specifications Regulatory Approvals PD4-16-F model only Complies with ULR 508 Complies with CSA C22.2, #14 Complies with NMX-J-515-ANCE-2008 PD4-16-F-CE model only Complies with EN 50178 Power 120 –240 V~ 50/60 Hz Environment Mount where ambient temperature is 32 °F to 104 °F (0 ºC to 40 ºC). Relative humidity 0%–90%, non-condensing. Indoor use only. Passive cooling. International Protection Marking: IP20 Mounting Surface-mount only. Enclosure with a maximum number of DPMs installed generates heat, maximum 140 BTUs / hour. Meets NEC® requirements for installation in “other space used for environmental air”. Construction 16-gauge (1.5 mm) powder-coated sheet metal enclosure. 16-gauge (1.5 mm) powder-coated metal cover with ventilation holes and hinged access door. Cover is attached using four Phillips-head screws. Includes two DIN rails for mounting DPMs or power supplies. Line / Mains Voltage Connections Wires land directly on DPMs or power supplies. Modules in the panel can be wired using one power feed or up to four power feeds. If feeding through Lutron power modules using Line / Mains terminals, the total load current must be less than or equal to 15 A. It is recommended that all feed splicing be done outside of this enclosure. Grounding Terminals 15 position aluminum ground bar (PD4-16-F) 23 position copper ground bar (PD4-16-F-CE) Capacity Enclosure can accommodate 4 DPMs or power supplies. Mounting for Panels For indoor use only. Surface-mount only. Install in accordance with all local and national electrical codes. Equipment is passively air-cooled. Panels weigh up to 30 lb (14 kg). Reinforce wall structure for weight and local codes. Use keyholes with bolts sufficient for 30 lb (14 kg) load, 1/4 in (M6) bolts recommended. Mount panel(s) within 7º of true vertical. Leave 6 in (153 mm) clearance on each side of panel. Mount in a location where the cover will not be blocked. 12 in (304 mm) of clearance is recommended in front of the panel, however a minimum of 3.03 in (77 mm) can be achieved: see Wall Cavity Mounting guidelines for more information. Panel can be installed in a minimum of 8.125 cubic feet (0.23 cubic meter) of confined space providing intake and exhaust venting requirements are met. See Wall Cavity Mounting section for details. Mount panel so Line / Mains voltage wiring is at least 6 ft (1.8 m) from sound or electronic equipment and wiring. Mount panel where audible noise is acceptable (internal relays on modules click). Panel(s) should be a minimum of 6in (153mm) from the floor and ceiling. Panel can be installed above a suspended ceiling. See Suspended Ceiling Installation section for details. Consult Dimensions page for panel size, conduit knockouts, and mounting hole locations. Panel Stacking Do not mount more than two PD4-16-F panels vertically. A single LV16 panel may be installed under as many as two PD4-16-F panels. A minimum vertical spacing of 6 in (153 mm) is required between each panel. If stacking two PD4-16-F panels above an LV16 panel, PDUs should only be provided by the LV16 panel. No PDUs should be provided by any modules located in the PD4-16-F panels. Suspended Ceiling Installation Panel(s) can be a minimum of 1 in (25 mm) from the top of the suspended ceiling and ceiling. Panels cannot be vertically stacked when installed above a suspended ceiling. Maintain 12 in (304 mm) of clearance in front of panel when mounting in a suspended ceiling. NOTE: Installation must comply with all working space requirements. Consult with your jurisdiction for local requirements. Wall Cavity Mounting In addition to the Panel Mounting requirements found in this document, the following is required when mounting panels into a wall cavity. Wall Cavity Mounting requires a minimum of 8.125 cubic feet (0.23 cubic meter) of confined space. This confined space requires a minimum of 27 square inches (442 square millimeters) of venting (area of vent openings / aperture) for each of the intake and exhaust vents. Intake vent must be located below the bottom panel while the exhaust vent must be located above the top panel. The confined space must have a Removable Access Panel large enough to service the equipment. Panels should only be surface-mounted. Panels should be mounted a minimum of 6 in (153 mm) from the floor and 6 in (153 mm) from the ceiling to ensure proper ventilation. NOTE: Installation must comply with all working space requirements. Consult with your jurisdiction for local requirements. NOTE: Installation must comply with all working space requirements. Consult with your jurisdiction for local requirements. Vent orientation: Proper venting is required to cool equipment correctly when installed behind a removable access panel. If louvered vents are used, they must be installed as shown below to allow required air flow and cooling. A minimum of 27 square inches (442 square millimeters) of venting (area of vent openings / aperture) required for each of the intake and exhaust vents. Panel Dimensions All dimensions shown as: in (mm) [...]<p><a class="btn btn-secondary understrap-read-more-link" href="https://usemanuals.com/olutron/pd4-16-f-lighting/">Read More...</a></p>]]></description>
										<content:encoded><![CDATA[<h3><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/Lutron-Logo-3-1024x149-1.webp" /></h3>
<h4>OLUTRON PD4-16-F Lighting Control Panels</h4>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/Product-221.webp" /></p>
<h4>DIN Panels and Accessories</h4>
<p>The Lutron myRoom and HomeWorks families of DIN rail panels are designed to accept DIN Power Modules (DPMs). The DPMs can be configured in the panel to control multiple load types to fit the size, lighting plan and design of the space.</p>
<h4>Features</h4>
<ul>
<li>Panels house up to four DIN Power Modules (DPMs) or up to three DIN Power Modules (DPMs) and one QSPS power supply.</li>
<li>Compatible DPMs
<ul>
<li>Digital Controllers</li>
</ul>
</li>
<li>LQSE-2ECO-D</li>
<li>LQSE-2DAL-D
<ul>
<li>Dimming</li>
</ul>
</li>
<li>MQSE-4A1-D</li>
<li>MQSE-3A1-D</li>
<li>MQSE-2A1-D</li>
<li>LQSE-4A1-D</li>
<li>LQSE-4T5-120-D</li>
<li>QSNE-4T10-D</li>
<li>LQSE-4T10-D
<ul>
<li>Switching</li>
</ul>
</li>
<li>MQSE-4S1-D</li>
<li>MQSE-3S1-D</li>
<li>MQSE-2S1-D</li>
<li>LQSE-4S5-230-D</li>
<li>LQSE-4S8-120-D</li>
<li>QSNE-4S10-D</li>
<li>LQSE-4S10-D
<ul>
<li>Power Supplies and Motor Controllers</li>
</ul>
</li>
<li>MQSPS-DH-1-30 (requires MQSPS-BRK)</li>
<li>QSPS-DH-1-75-H</li>
<li>LQSE-4M-D</li>
<li>Feed-through panel.</li>
<li>Panels extensively tested to ensure optimal thermal performance with maximum load in 32 °F to 104 °F (0 °C to 40 °C) ambient environment.</li>
<li>Panels are rated for 120–240 V~ ULR, CE and non-CE applications.</li>
</ul>
<h4>Models Available</h4>
<ul>
<li>PD4-16-F<br />
120–240 V~ Non-CE<br />
Line / Mains Voltage Enclosure</li>
<li>PD4-16-F-CE<br />
220–240 V~ CE<br />
Line / Mains Voltage Enclosure</li>
</ul>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/Image-01-79.webp" /></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/Image-02-71.webp" /></p>
<h4>Specifications</h4>
<p><strong>Regulatory Approvals PD4-16-F model only</strong></p>
<ul>
<li>Complies with ULR 508</li>
<li>Complies with CSA C22.2, #14</li>
<li>Complies with NMX-J-515-ANCE-2008</li>
</ul>
<p><strong>PD4-16-F-CE model only</strong></p>
<ul>
<li>Complies with EN 50178</li>
</ul>
<p><strong>Power</strong></p>
<ul>
<li>120 –240 V~ 50/60 Hz</li>
</ul>
<p><strong>Environment</strong></p>
<ul>
<li>Mount where ambient temperature is 32 °F to 104 °F (0 ºC to 40 ºC). Relative humidity 0%–90%, non-condensing.</li>
<li>Indoor use only.</li>
<li>Passive cooling.</li>
<li>International Protection Marking: IP20</li>
</ul>
<p><strong>Mounting</strong></p>
<ul>
<li>Surface-mount only.</li>
<li>Enclosure with a maximum number of DPMs installed generates heat, maximum 140 BTUs / hour.</li>
<li>Meets NEC® requirements for installation in “other space used for environmental air”.</li>
</ul>
<p><strong>Construction</strong></p>
<ul>
<li>16-gauge (1.5 mm) powder-coated sheet metal enclosure.</li>
<li>16-gauge (1.5 mm) powder-coated metal cover with ventilation holes and hinged access door. Cover is attached using four Phillips-head screws.</li>
<li>Includes two DIN rails for mounting DPMs or power supplies.</li>
</ul>
<p><strong>Line / Mains Voltage Connections</strong></p>
<ul>
<li>Wires land directly on DPMs or power supplies.</li>
<li>Modules in the panel can be wired using one power feed or up to four power feeds. If feeding through Lutron power modules using Line / Mains terminals, the total load current must be less than or equal to 15 A. It is recommended that all feed splicing be done outside of this enclosure.</li>
</ul>
<p><strong>Grounding Terminals</strong></p>
<ul>
<li>15 position aluminum ground bar (PD4-16-F)</li>
<li>23 position copper ground bar (PD4-16-F-CE)</li>
</ul>
<p><strong>Capacity</strong></p>
<ul>
<li>Enclosure can accommodate 4 DPMs or power supplies.</li>
</ul>
<h4>Mounting for Panels</h4>
<ul>
<li>For indoor use only.</li>
<li>Surface-mount only.</li>
<li>Install in accordance with all local and national electrical codes.</li>
<li>Equipment is passively air-cooled.</li>
<li>Panels weigh up to 30 lb (14 kg). Reinforce wall structure for weight and local codes.</li>
<li>Use keyholes with bolts sufficient for 30 lb (14 kg) load, 1/4 in (M6) bolts recommended.</li>
<li>Mount panel(s) within 7º of true vertical.</li>
<li>Leave 6 in (153 mm) clearance on each side of panel.</li>
<li>Mount in a location where the cover will not be blocked. 12 in (304 mm) of clearance is recommended in front of the panel, however a minimum of 3.03 in (77 mm) can be achieved: see Wall Cavity Mounting guidelines for more information.</li>
<li>Panel can be installed in a minimum of 8.125 cubic feet (0.23 cubic meter) of confined space providing intake and exhaust venting requirements are met. See Wall Cavity Mounting section for details.</li>
<li>Mount panel so Line / Mains voltage wiring is at least 6 ft (1.8 m) from sound or electronic equipment and wiring.</li>
<li>Mount panel where audible noise is acceptable (internal relays on modules click).</li>
<li>Panel(s) should be a minimum of 6in (153mm) from the floor and ceiling.</li>
<li>Panel can be installed above a suspended ceiling. See Suspended Ceiling Installation section for details.</li>
<li>Consult Dimensions page for panel size, conduit knockouts, and mounting hole locations.</li>
</ul>
<h4>Panel Stacking</h4>
<ul>
<li>Do not mount more than two PD4-16-F panels vertically.</li>
<li>A single LV16 panel may be installed under as many as two PD4-16-F panels.</li>
<li>A minimum vertical spacing of 6 in (153 mm) is required between each panel.</li>
<li>If stacking two PD4-16-F panels above an LV16 panel, PDUs should only be provided by the LV16 panel. No PDUs should be provided by any modules located in the PD4-16-F panels.</li>
</ul>
<h4>Suspended Ceiling Installation</h4>
<ul>
<li>Panel(s) can be a minimum of 1 in (25 mm) from the top of the suspended ceiling and ceiling.</li>
<li>Panels cannot be vertically stacked when installed above a suspended ceiling.</li>
<li>Maintain 12 in (304 mm) of clearance in front of panel when mounting in a suspended ceiling.</li>
</ul>
<p><img fetchpriority="high" decoding="async" class="aligncenter wp-image-467870 ezlazyloaded" src="images/8.webp" sizes="" srcset="" alt="Image 03" width="242" height="532" data-ezsrcset="https://manuals.plus/wp-content/uploads/2021/08/Image-03-62.png?ezimgfmt=ng:webp/ngcb1 315w,https://manuals.plus/wp-content/uploads/2021/08/Image-03-62-136x300.png?ezimgfmt=ng:webp/ngcb1 136w" data-ezsrc="https://manuals.plus/wp-content/uploads/2021/08/Image-03-62.png?ezimgfmt=rs:242x532/rscb1/ng:webp/ngcb1" /></p>
<p><strong>NOTE:</strong> Installation must comply with all working space requirements. Consult with your jurisdiction for local requirements.</p>
<h4>Wall Cavity Mounting</h4>
<p><strong>In addition to the Panel Mounting requirements found in this document, the following is required when mounting panels into a wall cavity.</strong></p>
<ul>
<li>Wall Cavity Mounting requires a minimum of 8.125 cubic feet (0.23 cubic meter) of confined space.</li>
<li>This confined space requires a minimum of 27 square inches (442 square millimeters) of venting (area of vent openings / aperture) for each of the intake and exhaust vents.</li>
<li>Intake vent must be located below the bottom panel while the exhaust vent must be located above the top panel.</li>
<li>The confined space must have a Removable Access Panel large enough to service the equipment.</li>
<li>Panels should only be surface-mounted.</li>
<li>Panels should be mounted a minimum of 6 in (153 mm) from the floor and 6 in (153 mm) from the ceiling to ensure proper ventilation.</li>
</ul>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/Image-04-57.webp" /></p>
<p><strong>NOTE:</strong> Installation must comply with all working space requirements. Consult with your jurisdiction for local requirements.</p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/Image-05-50.webp" /></p>
<p><strong>NOTE:</strong> Installation must comply with all working space requirements. Consult with your jurisdiction for local requirements.</p>
<p><strong>Vent orientation:</strong> Proper venting is required to cool equipment correctly when installed behind a removable access panel. If louvered vents are used, they must be installed as shown below to allow required air flow and cooling. A minimum of 27 square inches (442 square millimeters) of venting (area of vent openings / aperture) required for each of the intake and exhaust vents.</p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/Image-06-44.webp" /></p>
<h4>Panel Dimensions</h4>
<p>All dimensions shown as: in (mm)</p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/Image-07-40.webp" /></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/Lutron-Logo-3-1024x149-1.webp" /></p>
<form id="commentform" class="comment-form" action="https://manuals.plus/wp-comments-post.php" method="post" novalidate="">
<p class="form-submit">
</form>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>OLUTRON Fan Controls Manual</title>
		<link>https://usemanuals.com/olutron/fan-controls/</link>
		
		<dc:creator><![CDATA[ItsManual]]></dc:creator>
		<pubDate>Sat, 22 Jul 2023 17:34:36 +0000</pubDate>
				<category><![CDATA[OLUTRON]]></category>
		<guid isPermaLink="false">https://usemanuals.com/?p=171495</guid>

					<description><![CDATA[OLUTRON Fan Controls Dim your LED lights &#38; adjust fan speed from one wall control. Eliminates the need for pull chains. LED+ dimmer for LEDs and incandescent/halogen bulbs 4-speed fan control Available in 26 colors Single pole; no neutral wire or canopy module required Note: Separate wire required for fan and light Did you know? Lutron LED+ dimmers: Don’t require a neutral or special wire temperature rating Take the hassle out of low-end adjustments Use patented technology to prevent dimmer interaction and minimize flicker, for beautiful LED dimming Name and Model No. Fan speeds Fan amp Light control Maximum Wattage Control locations Required wiring LED Inc/Hal Fan / light controls Maestro MACL-LFQ* 4 1.5 A Dimmer LED / Inc / Hal 75 W 250 W Single pole 3 wires Diva DVFSQ-LF* 3 1.5 A Switch LED / Inc / Hal 120 W 240 W Single pole 3 wires Skylark S2-LFSQ* 3 1.5 A Dimmer Inc / Hal N/A 300 W Single pole 3 wires Fan-only controls Skylark SFSQ 3 1.5 A N/A N/A N/A Single pole 2 wires Skylark Contour CTFSQ 3 1.5 A N/A N/A N/A Single pole / 3-way 2 wires Ariadni AYFSQ _____________ Toggler TGFSQ 3 1.5 A N/A N/A N/A Single pole / 3-way 2 wires Rotary FSQ-2F 3 1.5 A N/A N/A N/A Single pole 2 wires * Requires separate wires in the backbox for fan and light— see “Wiring” section More options available online—visit lutron.com to learn more. Make sure to choose your fan control based on the type of wiring in your backbox 2-wire Single wire for both fan and light 3-wire Separate wires for fan and light Some fan / lights have a limiter. Please note that Lutron fan controls with a dimmer may not perform as intended when used with a fan / light with a limiter. Although most fans are alternating current (AC) fans, some newer fans are available with DC. Please note that Lutron fan controls are not designed to control DC fans. Exhaust fan controls Maestro MA-T51 Rotary FS-5F lutron.com/fans &#160; &#160; [...]<p><a class="btn btn-secondary understrap-read-more-link" href="https://usemanuals.com/olutron/fan-controls/">Read More...</a></p>]]></description>
										<content:encoded><![CDATA[<p><strong>OLUTRON Fan Controls</strong></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/Screenshot_14-39-259x300-1.webp" /></p>
<h4></h4>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/1-237-198x300-1.webp" /></p>
<p><strong>Dim your LED lights &amp; adjust fan speed from one wall control. Eliminates the need for pull chains.</strong></p>
<ul>
<li>LED+ dimmer for LEDs and incandescent/halogen bulbs</li>
<li>4-speed fan control</li>
<li>Available in 26 colors</li>
<li>Single pole; no neutral wire or canopy module required<br />
<strong>Note:</strong> Separate wire required for fan and light</li>
</ul>
<p><strong>Did you know?</strong><br />
<strong>Lutron LED+ dimmers:</strong></p>
<ul>
<li>Don’t require a neutral or special wire temperature rating</li>
<li>Take the hassle out of low-end adjustments</li>
<li>Use patented technology to prevent dimmer interaction and minimize flicker, for beautiful LED dimming</li>
</ul>
<h4></h4>
<table width="1319">
<tbody>
<tr>
<td rowspan="2" width="138">N<strong>ame and Model No.</strong></td>
<td rowspan="2" width="60"><strong>Fan speeds</strong></td>
<td rowspan="2" width="48"><strong>Fan amp</strong></td>
<td rowspan="2" width="84"><strong>Light control</strong></td>
<td colspan="2" width="144"><strong>Maximum Wattage</strong></td>
<td rowspan="2" width="90"><strong>Control locations</strong></td>
<td rowspan="2" width="90"><strong>Required wiring</strong></td>
</tr>
<tr>
<td width="72"><strong>LED</strong></td>
<td width="72"><strong>Inc/Hal</strong></td>
</tr>
<tr>
<td colspan="4" width="330"><strong>Fan / light controls</strong></td>
<td width="72"><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/Screenshot_15-38.webp" /></td>
<td width="72"><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/Screenshot_16-38.webp" /></td>
<td colspan="2" width="180"></td>
</tr>
<tr>
<td width="138"><strong><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/Screenshot_3-76-199x300-1.webp" />Maestro</strong><br />
MACL-LFQ*</td>
<td width="60">4</td>
<td width="48">1.5 A</td>
<td width="84"><strong>Dimmer</strong><br />
LED / Inc / Hal</td>
<td width="72">75 W</td>
<td width="72">250 W</td>
<td width="90">Single pole</td>
<td width="90">3 wires</td>
</tr>
<tr>
<td width="138"><strong><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/Screenshot_4-75-194x300-1.webp" />Diva<br />
</strong>DVFSQ-LF*</td>
<td width="60">3</td>
<td width="48">1.5 A</td>
<td width="84"><strong>Switch</strong><br />
LED / Inc / Hal</td>
<td width="72">120 W</td>
<td width="72">240 W</td>
<td width="90">Single pole</td>
<td width="90">3 wires</td>
</tr>
<tr>
<td width="138"><strong><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/Screenshot_5-68-190x300-1.webp" />Skylark</strong><br />
S2-LFSQ*</td>
<td width="60">3</td>
<td width="48">1.5 A</td>
<td width="84"><strong>Dimmer<br />
</strong>Inc / Hal</td>
<td width="72">N/A</td>
<td width="72">300 W</td>
<td width="90">Single pole</td>
<td width="90">3 wires</td>
</tr>
<tr>
<td colspan="8" width="654"><strong>Fan-only controls</strong></td>
</tr>
<tr>
<td width="138"><strong><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/Screenshot_6-63-189x300-1.webp" />Skylark</strong><br />
SFSQ</td>
<td width="60">3</td>
<td width="48">1.5 A</td>
<td width="84">N/A</td>
<td width="72">N/A</td>
<td width="72">N/A</td>
<td width="90">Single pole</td>
<td width="90">2 wires</td>
</tr>
<tr>
<td width="138"><strong><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/Screenshot_7-56-189x300-1.webp" />Skylark Contour</strong><br />
CTFSQ</td>
<td width="60">3</td>
<td width="48">1.5 A</td>
<td width="84">N/A</td>
<td width="72">N/A</td>
<td width="72">N/A</td>
<td width="90">Single pole / 3-way</td>
<td width="90">2 wires</td>
</tr>
<tr>
<td width="138"><strong><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/Screenshot_8-51-190x300-1.webp" />Ariadni</strong><br />
AYFSQ<br />
_____________<br />
<strong>Toggler</strong><br />
TGFSQ</td>
<td width="60">3</td>
<td width="48">1.5 A</td>
<td width="84">N/A</td>
<td width="72">N/A</td>
<td width="72">N/A</td>
<td width="90">Single pole / 3-way</td>
<td width="90">2 wires</td>
</tr>
<tr>
<td width="138"><strong><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/Screenshot_9-47-190x300-1.webp" />Rotary<br />
</strong>FSQ-2F</td>
<td width="60">3</td>
<td width="48">1.5 A</td>
<td width="84">N/A</td>
<td width="72">N/A</td>
<td width="72">N/A</td>
<td width="90">Single pole</td>
<td width="90">2 wires</td>
</tr>
</tbody>
</table>
<p>* Requires separate wires in the backbox for fan and light— see “Wiring” section<br />
More options available online—visit lutron.com to learn more.</p>
<h4></h4>
<p>Make sure to choose your fan control based on the type of wiring in your backbox</p>
<p><strong>2-wire</strong><br />
Single wire for both fan and light<br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/Screenshot_10-49-269x300-1.webp" /></p>
<p><strong>3-wire</strong><br />
Separate wires for fan and light<br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/Screenshot_11-49-269x300-1.webp" /></p>
<h4></h4>
<p>Some fan / lights have a limiter. Please note that Lutron fan controls with a dimmer may not perform as intended when used with a fan / light with a limiter.</p>
<h4></h4>
<p>Although most fans are alternating current (AC) fans, some newer fans are available with DC. Please note that Lutron fan controls are not designed to control DC fans.</p>
<h4></h4>
<h5>Exhaust fan controls</h5>
<p><strong>Maestro</strong><br />
MA-T51<br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/Screenshot_12-43-191x300-1.webp" /></p>
<p><strong>Rotary</strong><br />
FS-5F<br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/Screenshot_13-40-188x300-1.webp" /></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/Screenshot_2-97-300x37-1.webp" /><br />
<a href="http://lutron.com/fans" target="_blank" rel="noopener">lutron.com/fans</a></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/Screenshot_1-103-300x49-1.webp" /></p>
<form id="commentform" class="comment-form" action="https://manuals.plus/wp-comments-post.php" method="post" novalidate="">
<p class="form-submit">
</form>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>

<!--
Performance optimized by W3 Total Cache. Learn more: https://www.boldgrid.com/w3-total-cache/

Page Caching using Disk: Enhanced 

Served from: usemanuals.com @ 2026-06-08 17:20:25 by W3 Total Cache
-->