<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Navien &#8211; UseManuals</title>
	<atom:link href="http://usemanuals.com/navien/feed/" rel="self" type="application/rss+xml" />
	<link>https://usemanuals.com</link>
	<description>Owner&#039;s manuals for all sorts of products</description>
	<lastBuildDate>Sat, 08 Apr 2023 05:33:47 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.7.2</generator>

<image>
	<url>https://usemanuals.com/wp-content/uploads/2025/02/favicon-32x32-2.png</url>
	<title>Navien &#8211; UseManuals</title>
	<link>https://usemanuals.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Navien NPE-180A2 Tankless Water Heater manual</title>
		<link>https://usemanuals.com/navien/npe-180a2-water-heater/</link>
		
		<dc:creator><![CDATA[ItsManual]]></dc:creator>
		<pubDate>Sat, 08 Apr 2023 05:33:47 +0000</pubDate>
				<category><![CDATA[Navien]]></category>
		<guid isPermaLink="false">https://usemanuals.com/?p=63770</guid>

					<description><![CDATA[&#160; Navien NPE-180A2 Tankless Water Heater Installation Guide Model NPE-180A2 / 210A2 / 240A2 NPE-150S2/180S2 / 210S2 / 240S2 Before Installing Read the Installation Manual before installing.  This product must be installed and serviced by a licensed plumber, a licensed gas fitter, or a professional service technician. Navien is not liable for any damages or defects resulting from improper installation. When applicable, the installation must conform with Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 and/or CAN/CSA Z240 MH Series, Mobile Homes. Do not install this water heater in a recreational vehicle, trailer, boat or other vehicular type unit as it will result in a Carbon Monoxide Poisoning Hazard. WARNING Follow all local codes and/or the most recent edition of the National Fuel Gas Code (ANSI Z223.1/NFPA 54) in the USA, or the Natural Gas and Propane Installation Code in Canada (CAN/CGA B149.1). Safety DO NOT install in areas with excessively high humidity. Location Requirements Select the best location on “Choosing an Installation Location” in the Installation Manual. Allowable minimum clearances Installing Unpacking Checking the Rating Plate This water heaters come from the factory configured for use with Natural Gas (NG). Before starting the installation, check the rating plate located on the side of the water heater to ensure that the water heater matches the gas type, gas pressure, water pressure, and electrical supply available in the installation location. If the water heater does not match each of these ratings, do not install the water heater. If conversion to Propane Gas is required, the included Propane conversion kit must be used. WARNING Before connecting the gas supply, determine the gas type and pressure for the water heater by referring to the rating plate. Use only the same gas type indicated on the rating plate. Using a different gas type will result in abnormal combustion and malfunction of the water heater. Gas supplies should be connected by a licensed professional only. The appliance and its gas connection must be leak tested before placing the appliance in operation. This water heater cannot be converted from natural gas to propane or vice versa without a Navien gas conversion kit. Do not attempt a field  conversion of this water heater without a Navien gas conversion kit. Doing so will result in dangerous operating conditions and will void the  warranty. Navien Inc. is not liable for any property damage and/or personal injury resulting from improper conversions. Mounting on the Wall CAUTION Do not install the water heater on drywall without proper reinforcement. Drill in the supplied anchor bolts after considering where the vent termination will be located. Secure the mounting bracket to the wall with the tapping screws and anchors. Lift up the water heater, rest the unit on the hooks provided on the wall bracket on the wall. Install two set screws through the bracket at the bottom of the water heater to secure the water heater on the wall. Removing the Front Cover Gas Piping Connections Example: * 1 CFH=1,020 Btuh 1/2″ rigid pipe can be used; refer to the sizing tables in the Installation Manual for limitations. Avoid using 1/2″ corrugated connectors or tubing as noise may occur. Water Piping Connections (NPE-180A2/210A2/240A2) Internal Recirculation External Recirculation using the Cold Water Inlet External Recirculation using the Recirculation Inlet Internal Recirculation Settings Press the Menu button () to access the Main menu, and select 1. Recirculation Setting &#62; 3. Internal Recirculation by pressing the OK button (OK). External Recirculation Settings Press the Menu button () to access the Main menu, and select 1. Recirculation Setting &#62; 2. External Recirculation by pressing the OK button (OK). Condensate Drain Connection A condensate drain pipe must be connected to the ½2″ condensate outlet fitting at the bottom of the unit and water must be poured into the exhaust connection to fill the condensate trap. The end of the ½” (NPT) plastic piping should drain into a laundry tub or into a floor drain. Note Do not submerge the end of the pipe in water. Venting Vent Termination Options Indoor Horizontal Vent Termination  Vertical vent termination Sidewall vent termination Concentric Vent Termination Sidewall installation Roof installation Image of outdoor vent cap Venting Length Exhaust Vent Piping Materials Venting requirements differ in the US and Canada. Consult the following chart or the most recent edition of ANSI Z223.1/NFPA 54 or CAN/CGA B149.1, as well as all applicable local codes and regulations when selecting vent pipe materials. Do not use cellular core PVC (ASTM F891), cellular core CPVC, Radel® (polyphenolsulfone) for the exhaust vent. Navien recommended venting materials * Refer to the manufacturer’s literature for detailed information on approved vent materials. ** For installation in Canada, field-supplied plastic vent piping must comply with CAN/CGA B149.1 (latest edition) and be certified to the Standard. For Type BH Gas Venting Systems, ULC-S636. Components of this listed system must not be interchanged with other vent systems or unlisted pipes or fittings. All plastic components and specified primers and glues of the certified vent system must be from a single system manufacturer and must not be intermixed with another system manufacturer’s parts. The supplied vent connector and vent termination are certified as part of the water heater. Electrical Connections After Installing Opening All the Valves Gas Valve Operating the Water Heater Power ON To turn the water heater on, press the Power button (). When the power is on for the first time, you must complete the start-up wizard. The temperature will appear on the front panel display after then when the power is on. Adjust the Water Temperature Press the Up button () or the Down button () until the desired temperature appears on the display. You can adjust the temperature while the display is flashing. Once the display stops flashing, the temperature setting is stored. View Basic Information To access to view the water heater’s operating conditions, configure the DHW temperature, or review the error history, press the Menu button (). Note If resetting does not solve the problem, refer to the troubleshooting section of the User’s Information Manual or contact the service center. Resetting the Water Heater If an error message appears, you can try resetting the water heater to resolve the problem. To reset the water heater, press the Back button (). Measuring the Inlet Gas Pressure CAUTION The Navien water heater cannot operate properly without sufficient inlet gas pressure and volume. The instructions on how to check the inlet gas  pressure are stated above. THIS IS ONLY TO BE DONE BY A LICENSED PROFESSIONAL. Installing the Front Cover Ensure Maximum Water Flow After using the water heater for the first 10 minutes, please stop using it and clean the cold water filter and recirculation water filter of any trapped debris. Final Check A trial run should be performed in accordance with the Installation checklist listed in the Installation Manual. Navien, Inc. 20 Goodyear, Irvine, CA 92618 Tel: 1-800-519-8794, Fax: 1-949-420-0430 www.navieninc.com [...]<p><a class="btn btn-secondary understrap-read-more-link" href="https://usemanuals.com/navien/npe-180a2-water-heater/">Read More...</a></p>]]></description>
										<content:encoded><![CDATA[<p>&nbsp;</p>
<h3>Navien NPE-180A2 Tankless Water Heater Installation Guide</h3>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/03/Navien-Logo-1.webp" /></p>
<p><strong>Model<br />
</strong><strong>NPE-180A2 / 210A2 / 240A2</strong><br />
<strong>NPE-150S2/180S2 / 210S2 / 240S2</strong></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/03/Navien-Barcode.webp" /></p>
<h4>Before Installing</h4>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/03/Warning-Symbol-5.webp" /></p>
<p><strong><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/03/Manual-2.webp" />Read the Installation Manual before installing. </strong></p>
<p><strong>This product must be installed and serviced by a licensed plumber, a licensed gas fitter, or a professional service technician. Navien is not liable for any damages or defects resulting from improper installation. When applicable, the installation must conform with Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 and/or CAN/CSA Z240 MH Series, Mobile Homes.</strong></p>
<p><strong>Do not install this water heater in a recreational vehicle, trailer, boat or other vehicular type unit as it will result in a Carbon Monoxide Poisoning Hazard.</strong></p>
<p><strong><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/03/Warning-Symbol-5.webp" />WARNING</strong></p>
<p><strong>Follow all local codes and/or the most recent edition of the National Fuel Gas Code (ANSI Z223.1/NFPA 54) in the USA, or the Natural Gas and Propane Installation Code in Canada (CAN/CGA B149.1).</strong></p>
<p><strong>Safety</strong></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/03/Safety-1.webp" /></p>
<p><strong>DO NOT install in areas with excessively high humidity.</strong></p>
<p><strong>Location Requirements</strong></p>
<p>Select the best location on “Choosing an Installation Location” in the Installation Manual.</p>
<p><strong>Allowable minimum clearances</strong></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/03/Allowable-minimum-clearances.webp" /></p>
<h4>Installing</h4>
<h5>Unpacking</h5>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/03/Unpacking-7.webp" /></p>
<h5>Checking the Rating Plate</h5>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/03/Checking-the-Rating-Plate.webp" /></p>
<p>This water heaters come from the factory configured for use with Natural Gas (NG). <strong>Before starting the installation</strong>, check the rating plate located on the side of the water heater to ensure that the water heater matches the gas type, gas pressure, water pressure, and electrical supply available in the installation location. <strong>If the water heater does not match each of these ratings, do not install the water heater</strong>.<br />
If conversion to Propane Gas is required, the included Propane conversion kit must be used.</p>
<p><strong><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/03/Warning-Symbol-5.webp" />WARNING</strong></p>
<ul>
<li>Before connecting the gas supply, determine the gas type and pressure for the water heater by referring to the rating plate. Use only the same gas type indicated on the rating plate. Using a different gas type will result in abnormal combustion and malfunction of the water heater. Gas supplies should be connected by a licensed professional only.</li>
<li>The appliance and its gas connection must be leak tested before placing the appliance in operation.</li>
<li>This water heater cannot be converted from natural gas to propane or vice versa without a Navien gas conversion kit. Do not attempt a field  conversion of this water heater without a Navien gas conversion kit. Doing so will result in dangerous operating conditions and will void the  warranty.</li>
</ul>
<p><strong>Navien Inc. is not liable for any property damage and/or personal injury resulting from improper conversions.</strong></p>
<h5>Mounting on the Wall</h5>
<p><strong><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/03/Warning-Symbol-5.webp" />CAUTION</strong></p>
<p><strong>Do not install the water heater on drywall without proper reinforcement.</strong></p>
<ol>
<li>Drill in the supplied anchor bolts after considering where the vent termination will be located.</li>
<li>Secure the mounting bracket to the wall with the tapping screws and anchors.</li>
<li>Lift up the water heater, rest the unit on the hooks provided on the wall bracket on the wall.</li>
<li>Install two set screws through the bracket at the bottom of the water heater to secure the water heater on the wall.</li>
</ol>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/03/Mounting-on-the-Wall.webp" /></p>
<h5>Removing the Front Cover</h5>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/03/Removing-the-Front-Cover.webp" /></p>
<h5>Gas Piping Connections</h5>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/03/Gas-Piping-Connections.webp" /></p>
<p>Example:</p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/03/Example.webp" /></p>
<p>* 1 CFH=1,020 Btuh</p>
<p>1/2″ rigid pipe can be used; refer to the sizing tables in the Installation Manual for limitations. Avoid using 1/2″ corrugated connectors or tubing as noise may occur.</p>
<h5>Water Piping Connections (NPE-180A2/210A2/240A2)</h5>
<p><strong>Internal Recirculation</strong></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/03/Internal-Recirculation.webp" /></p>
<p><strong>External Recirculation using the Cold Water Inlet</strong></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/03/External-Recirculation-using-the-Cold-Water-Inlet.webp" /></p>
<p><strong>External Recirculation using the Recirculation Inlet</strong></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/03/External-Recirculation-using-the-Recirculation-Inlet.webp" /></p>
<p><strong>Internal Recirculation Settings</strong></p>
<p>Press the Menu button (<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/03/Menu-Button-1.webp" />) to access the Main menu, and select <strong>1. Recirculation Setting</strong> &gt; <strong>3. Internal Recirculation</strong> by pressing the OK button (OK).</p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/03/Internal-Recirculation-Settings.webp" /></p>
<p><strong>External Recirculation Settings</strong></p>
<p>Press the Menu button (<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/03/Menu-Button-1.webp" />) to access the Main menu, and select <strong>1. Recirculation Setting</strong> &gt; <strong>2. External Recirculation</strong> by pressing the OK button (OK).</p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/03/External-Recirculation-Settings.webp" /></p>
<h5>Condensate Drain Connection</h5>
<p>A condensate drain pipe must be connected to the ½2″ condensate outlet fitting at the bottom of the unit and water must be poured into the exhaust connection to fill the condensate trap.</p>
<p>The end of the ½” (NPT) plastic piping should drain into a laundry tub or into a floor drain.</p>
<p><strong>Note</strong> Do not submerge the end of the pipe in water.</p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/03/Condensate-Drain-Connection.webp" /></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/03/Condensate-Drain-Connection-Continued.webp" /></p>
<h5>Venting</h5>
<p><strong>Vent Termination Options</strong></p>
<p><strong>Indoor Horizontal Vent Termination </strong></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/03/Indoor-Horizontal-Vent-Termination-.webp" /></p>
<p><strong>Vertical vent termination</strong></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/03/Vertical-vent-termination.webp" /></p>
<p><strong>Sidewall vent termination</strong></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/03/Sidewall-vent-termination.webp" /></p>
<p><strong>Concentric Vent Termination</strong></p>
<p><strong>Sidewall installation</strong></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/03/Sidewall-installation.webp" /></p>
<p><strong>Roof installation</strong></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/03/Roof-installation.webp" /></p>
<p><strong>Image of outdoor vent cap</strong></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/03/Image-of-outdoor-vent-cap.webp" /></p>
<p><strong>Venting Length</strong></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/03/Venting-Length.webp" /></p>
<p><strong>Exhaust Vent Piping Materials</strong></p>
<p>Venting requirements differ in the US and Canada. Consult the following chart or the most recent edition of ANSI Z223.1/NFPA 54 or CAN/CGA B149.1, as well as all applicable local codes and regulations when selecting vent pipe materials. Do not use cellular core PVC (ASTM F891), cellular core CPVC, Radel® (polyphenolsulfone) for the exhaust vent.</p>
<p><strong>Navien recommended venting materials</strong></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/03/Navien-recommended-venting-materials.webp" /></p>
<p>* Refer to the manufacturer’s literature for detailed information on approved vent materials.</p>
<p>** For installation in Canada, field-supplied plastic vent piping must comply with CAN/CGA B149.1 (latest edition) and be certified to the Standard. For Type BH Gas Venting Systems, ULC-S636. Components of this listed system must not be interchanged with other vent systems or unlisted pipes or fittings. All plastic components and specified primers and glues of the certified vent system must be from a single system manufacturer and must not be intermixed with another system manufacturer’s parts. The supplied vent connector and vent termination are certified as part of the water heater.</p>
<h5>Electrical Connections</h5>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/03/Electrical-Connections.webp" /></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/03/Electrical-Connections-Continued.webp" /></p>
<h4>After Installing</h4>
<h5>Opening All the Valves</h5>
<p><strong>Gas Valve</strong></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/03/Gas-Valve.webp" /></p>
<h5>Operating the Water Heater</h5>
<p><strong>Power ON</strong></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/03/Power-ON-9.webp" /></p>
<p>To turn the water heater on, press the Power button (<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/03/Power-button.webp" />).</p>
<p>When the power is on for the first time, you must complete the start-up wizard. The temperature will appear on the front panel display after then when the power is on.</p>
<p><strong>Adjust the Water Temperature</strong></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/03/Adjust-the-Water-Temperature.webp" /></p>
<p>Press the Up button (<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/03/Up-button.webp" />) or the Down button (<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/03/Down-button.webp" />) until the desired temperature appears on the display. You can adjust the temperature while the display is flashing. Once the display stops flashing, the temperature setting is stored.</p>
<p><strong>View Basic Information</strong></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/03/View-Basic-Information.webp" /></p>
<p>To access to view the water heater’s operating conditions, configure the DHW temperature, or review the error history, press the Menu button (<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/03/Menu-Button-1.webp" />).</p>
<p><strong>Note</strong> If resetting does not solve the problem, refer to the troubleshooting section of the User’s Information Manual or contact the service center.</p>
<p><strong>Resetting the Water Heater</strong></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/03/Resetting-the-Water-Heater.webp" /></p>
<p>If an error message appears, you can try resetting the water heater to resolve the problem. To reset the water heater, press the Back button (<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/03/Back-button.webp" />).</p>
<h5>Measuring the Inlet Gas Pressure</h5>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/03/Measuring-the-Inlet-Gas-Pressure-1.webp" /></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/03/Measuring-the-Inlet-Gas-Pressure-2.webp" /></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/03/Measuring-the-Inlet-Gas-Pressure-3.webp" /></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/03/Measuring-the-Inlet-Gas-Pressure-4.webp" /></p>
<p><strong><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/03/Warning-Symbol-5.webp" />CAUTION</strong></p>
<p>The Navien water heater cannot operate properly without sufficient inlet gas pressure and volume. The instructions on how to check the inlet gas  pressure are stated above. <strong>THIS IS ONLY TO BE DONE BY A LICENSED PROFESSIONAL</strong>.</p>
<h5>Installing the Front Cover</h5>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/03/Installing-the-Front-Cover.webp" /></p>
<h5>Ensure Maximum Water Flow</h5>
<p>After using the water heater for the first 10 minutes, please stop using it and clean the cold water filter and recirculation water filter of any trapped debris.</p>
<h5>Final Check</h5>
<p>A trial run should be performed in accordance with the Installation checklist listed in the Installation Manual.</p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/03/Navien-Logo-1.webp" /></p>
<p>Navien, Inc.<br />
20 Goodyear, Irvine, CA 92618<br />
Tel: 1-800-519-8794, Fax: 1-949-420-0430<br />
<a href="http://www.navieninc.com/" target="_blank" rel="noopener">www.navieninc.com</a></p>
<form id="commentform" class="comment-form" action="https://manuals.plus/wp-comments-post.php" method="post" novalidate="">
<p class="form-submit"><input id="comment_post_ID" name="comment_post_ID" type="hidden" value="1264202" /><br />
<input id="comment_parent" name="comment_parent" type="hidden" value="0" /></p>
</form>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>

<!--
Performance optimized by W3 Total Cache. Learn more: https://www.boldgrid.com/w3-total-cache/

Page Caching using Disk: Enhanced 

Served from: usemanuals.com @ 2026-08-26 05:38:13 by W3 Total Cache
-->