<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Maxell &#8211; UseManuals</title>
	<atom:link href="http://usemanuals.com/maxell/feed/" rel="self" type="application/rss+xml" />
	<link>https://usemanuals.com</link>
	<description>Owner&#039;s manuals for all sorts of products</description>
	<lastBuildDate>Mon, 07 Aug 2023 16:09:44 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.7.2</generator>

<image>
	<url>https://usemanuals.com/wp-content/uploads/2025/02/favicon-32x32-2.png</url>
	<title>Maxell &#8211; UseManuals</title>
	<link>https://usemanuals.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>maxell llexam PA1777-00 Manual</title>
		<link>https://usemanuals.com/maxell/llexam-pa1777-00/</link>
		
		<dc:creator><![CDATA[ItsManual]]></dc:creator>
		<pubDate>Mon, 07 Aug 2023 16:09:44 +0000</pubDate>
				<category><![CDATA[Maxell]]></category>
		<guid isPermaLink="false">https://usemanuals.com/?p=190234</guid>

					<description><![CDATA[PA1777-00 Intense Pulsed Light Device MXIP -100 User Manual Thank you for purchasing Maxell product. Please read the user manual in advance and use the product safely. Content of the package Introduction About the user manual Contents of this user manual might be changed in the future without prior notice. For product improvement, change of appearance or specification might not be announced in advance. Except for personal use, any unauthorized copying of part or all parts of this manual is prohibited. Unauthorized republication is strictly prohibited. Disclaimer Maxell shall not be responsible for any damage caused by fires, earthquakes, the action of a third party, any accidents, intended or unintended misuse, or another usage under abnormal conditions. All explicit and implicit contents not stated in the warranty card are not covered. Maxell shall not be responsible for failure due to any damage caused by usage other than described in the instruction manual. This product is not being designed to be any equipment or device which could be concerned with human life such as medical device, nuclear device, astronomic device, transportation device, etc., nor equipment or devices which requires high reliability. In case this product is used for the above equipment and/or systems, Maxell do not responsible for any injuries or fire accidents caused by the failure of this product. Safety Precaution Please strictly follow and use safely. Danger Danger refers to misuse which might lead to death or serious injury *1 to a high degree. Warning The warning refers to misuse which might lead to death or serious injury *1 Caution Caution refers to misuse which might lead to injury *2 or damage *3. *1: Serious injury refers to blindness or injuries, burnt, electric shock, bone fracture, poisoned or injury with after-effect, or resulted in hospitalization or long-term follow-up consultation. *2: Injury refers to burnt, electric shock which do not result in hospitalization or long-term follow-up consultation. *3: Damages refers broad damages to houses or properties and domestic animals/pets. Example of symbols Prohibited actions when handling the product. The shape of graphic symbol that indicates specific notes is shown in black. Caution to fire, explosion, high temperature when handling the product. The shape of graphic symbol that indicates specific notes is shown in black. instruction which must be followed when handling the product. The shape of graphic symbol that indicates specific notes is shown in black. Danger Those who use electric medical devices implanted in the body such as pacemakers should keep the main unit away from these medical devices It may cause an accident or poor physical condition. Warning The following people do not use this device ・Person being treated by a doctor ・People under 18 ・Pregnant or menstruating ・Skin perception disorders ・ People with fever. ・Person with allergies, person who is prone to rashes caused by cosmetics, clothing, metals, etc ・People with acute diseases, tuberculosis, infectious, malignant tumours, etc.・Person with allergies, dermatitis, eczema, herpes and other skin diseases ・Person whose skin is sensitive to sunlight ・Those who cannot express their intentions ・People who are recently consumed alcohol. It may cause accidents or physical deterioration. Do not use in the following areas ・Sunburned skin ・Dark spots, such as freckles, stains and black moles ・Scabs, cuts, rashes, bruises, warts, pimples, rashes, insect bites ・Skin cancer, ringworm, folliculitis, varicose veins ・Hemangiomas ・Cosmetic surgery area ・Around eyes, eyebrows, lips, neck, abdomen (female only), genital parts, back ・Tattoos, and permanent make-up ・ On make-up Do not use over the area that had peeling treatment. It may cause skin trouble. Do not use directly on eyes It may damage your eyes. Do not irradiate on hair or clothes It may cause burn or deformation. Do not use perfume or make-up products immediately after the treatment. (Excluding cream or lotion for moisturizing) It may cause skin trouble. If you are taking medication continuously, please consult your doctor before use. It may cause accidents or physical deterioration. Store in a place out of reach of children It may cause burn, electric shock or injury. If an abnormality occurs, immediately stop using and disconnect the power plug It may cause smoke, fire, electric shock or injury. Do not modify, disassemble or repair It may cause smoke, electric shock or injury. Plug the AC adaptor to AC outlet firmly Partially plugged AC adaptor may cause to fire or electric shock. Do not use loose plugs It may cause electric shock, short circuit or fire. Do not use any voltage other than the specified power supply voltage This may cause electric shock or fire. The power input of the AC adaptor of this product is AC100~240. Do not damage, forcibly bend, twist, put heavy objects on, pinch, bundle, or modify the power cable and power adapter It may cause smoke or fire. Warning Do not cover the power adapter with a cloth or a cover Heat will accumulate and cause deformation of the case, fire or electric shock. Do not use a power adapter other than the provided power adapter This may cause overheat, smoke, fire, malfunction or injury. Check whether the main unit is deformed, cracked or damaged before use. This may cause malfunction or injury. Immediately stop use if the main unit dropped or damaged Continuation of use may cause electric shock, fire or injury. Do not use in a dark room This may damage your eyes. Do not look directly or let others look directly at the irradiation window This may damage your eyes. Do not block the air inlet or outlet ports This may cause overheat, smoke, fire. Do not use for any purpose other than that described in the instruction manual This may cause malfunction, injury. Do not use for pets This may cause burns or injury. Do not put into heating appliances such as microwave ovens or pressure cookers This may cause smoke or fire. Do not put into a fire This may cause overheat, fire or leakage. Do not use or store near heating devices such as stoves This may cause overheat or fire. Do not place the product in direct sunlight or outdoor This may cause malfunction. Do not put into refrigerators This may cause malfunction. Do not splash or soak in water It may cause electric shock or malfunction. Do not use with wet hands This may cause overheat, electric shock or malfunction. Do not use the product in a humid place such as the bathroom This may cause overheat or malfunction. When unplugging the power plug, always hold the plug without pulling the cable It may cause electric shock, short circuit or fire. Always unplug the power plug from the power outlet when cleaning It may cause electric shock. Caution Do not use while wearing wet clothes This may cause electric shock. Do not irradiate the same site repeatedly This may cause burn or injury Do not touch the irradiated site during or immediately after use This may cause burn Do not use while wearing metal ornaments such as necklaces This may cause malfunction or burn Do not drop or throw against something This may cause malfunction or burn Regularly check the irradiation part for contamination This may cause malfunction or burn Unplug the power plug from the power outlet when not in use This may cause electric shock, smoke, fire. Features This product is a device that irradiates the skin with light to remove unwanted hair. A cooling plate is installed around the irradiation window to cool down the skin at the same  time as irradiation. It lessens the pain and heat during irradiation and gently cares for the skin. Cooling Plate The plate gets cold when the power is turned on. It cools the skin while irradiating. Irradiation times 500,000times 5-Levels Output Setting Mode Switching Single Mode: Irradiate manually each time. Continuous Mode: Automatic continuous irradiation. LCD Display The remaining irradiation count, output level, mode, and irradiation preparation status can be checked on the LCD display. Skin Detection Sensor Sensors on both sides of the irradiation window. When the sensor detects skin contact, the device can irradiate. Auto-oﬀ Function If there is no operation for 3 minutes with the power on, the power will turn off automatically. Part Names Recommended Treatment Area The time is an approximate time when used at level 1. Frequency of Use week First 1~4 1 week  once week 5~8 1 or 2 weeks once week 9~12 2 weeks or 1 month once If hair growth is no longer seen, it is not necessary to perform the treatment as often as above. If hair becomes visible again, perform the treatment as needed. Caution ・The efiect depends on the area of use and personal constitution. ・Do not exceed the above frequency of use. Preparation before use Check the skin and hair color Please check the attached color chart. Remove make-ups Use on bare skin (Remove all make-up, lotion, cream and perfume) It may cause skin trouble if used on make-up. Removing hair Be sure to remove hair before using. Hair growth or hair remaining on the skin surface can cause burns. Please do not remove the hair from the root, such as waxing or pulling out hair with a tweezer. Remove the protective film attached to the display. Allergy Test When using for the first time, or has not used for a period of time, please perform an allergy test to make sure that no skin trouble occurs. (See P.10 for how to use) Irradiate the  area where you want to use once with output level 1. After 48 hours, check the tested area for any abnormalities. Please consult your doctor if any abnormalities are seen such as redness Caution ・Do not irradiate the allergy-tested area within a week. ・Stop using if skin irritation occurs (such as redness) and consult a dermatologist if irritation continues after 2 days. Operating Instructions Caution ・Please keep the room bright when using.・Storage light will be generated when irradiating, please make sure that there are no people or pets nearby.・Strong light is emitted  during use. Be careful not to look directly at the area of use. • When using on face, please close your eyes. Connect Power Turn on the Power Press and hold the power button (for 2 seconds) to turn on the power. A beep sounds and the display lights up. When the power is turned on, the setting is single-mode and output is level 1. Switch Output Level The output level can be switched by short pressing the power button. Select the output level you are using. ※If you are using the device for the first time, we recommend that you start from output level 1. Switch the mode The mode can be switched by long pressing the multi button (for 2 seconds). Select the mode to use. Single Mode When you want to perform a treatment for a small area or sensitive area Continuous irradiation mode When you want to effciently care for a wide area *Continuous mode is a mode of continuously irradiated with preset output level. *The level cannot be changed in continuous mode. For each mode, see the mode description below to use . Single Mode Press against the area you want to use. Make sure there is no gap between the irradiation window and the area you want to irradiate. The display flashes while the skin detection sensor is in contact with the skin. *If the skin detection sensor is not in contact with the skin, the device cannot irradiate. Ready for irradiation Irradiation is ready when the entire display flashes. IrradiationIt irradiates when the multi-button is pressed. Repeat irradiation Move the irradiation position and repeat steps❶ to ❸ The irradiation interval is approx. 1 to 3 seconds. It depends on the output level. Continuous Mode Press against the area you want to use Make sure there is no gap between the irradiation window and the area you want to irradiate. ※If the skin detection sensor is not in contact with the skin, the device cannot irradiate. Irradiate automatically When the skin detection sensor detects the skin, irradiation will start immediately. Repeat irradiation Slide the main unit at the same speed. Be careful not to overlap the irradiated area. The irradiation interval is about 1 to 3 seconds. It depends on the output level. Cool-down Function When the temperature inside the main unit rises, it stops operating and cools down for 20 seconds. ※the timing to cool down depends on the output level and the surrounding environment. 5. Finish Press and hold the power button (for 2 seconds) to turn off the power. Unplug the power plug from the power outlet. ※When the power is turned off, the temperature inside the main body is transmitted to the cooling plate, which may cause the cooling plate to become warm. Allow time for it to cool down before cleaning. Caution As the level gets higher, more heat is felt. However, it is not abnormal. Smoke and odor may occur due to the burning of hair during use. Do not continuously irradiate at the same area. This product has a cooling function as being used, however, if you are concerned about the heat of your skin or burning sensation or redness, cool the skin down with a towel soaked with cold water, etc. If you experience severe pain, stop using immediately. Caution If an irradiation error occurs, “E30” is displayed and the operation will stop for 30 seconds. If there is no operation for 3 minutes with the power on, the power will turn off automatically. Do not leave it plugged in after use. Depending on the ambient temperature, the cooling plate may not cool suficiently and may not feel cold. Maintenance Always stop operation and unplug the power plug from the power outlet when cleaning. Just after use, the irradiation window and cooling plate will still keep the temperature, so please cool down a little before cleaning. Gently wipe off the irradiation window, cooling plate, and main unit with a dry cloth. For parts that are dificult to wipe, wipe them gently with a cotton swab. Caution This product is not waterproof. Do not soak it in water or splash it with water. Do not use chemicals such as benzine, thinner, and alcohol. Troubleshooting (when problem arise) Problem Cause Solution The display is not showing Power is off Connect the power adapter and power cable securely Not using a dedicated power adapter Use the provided power adapter and cable The time to press and hold the power button is too short Press and hold the power button (for 2 seconds) Not irradiating The skin detection sensor is not responding Both skin detection sensors should be in contact with the skin The remaining counts of irradiation are insufficient The number of counts of irradiations that can be used is 500,000 Cannot switch modes The time to press and hold the multi-button is too short Press and hold the multi button (for 2 seconds) Cannot switch levels The mode is set to continuous irradiation mode Press and hold the multi-button (for 2 seconds) to switch to single mode Power turns off Not operating for 3 minutes The auto-off function is working There is an error Unplug the power plug and wait a while Insert the power plug and turn on the power The cooldown function is repeated frequently It is used continuously for a long period of time and the inside the main body is generating heat Stop using the device for a while until it reaches room temperature The cooling plate is wet during use Condensation on the cooling plate It is not abnormal If you are concerned, wipe it off before using Cooling plate does not cool The ambient temperature is too high Please use within the operating temperature range If the symptom does not improve, unplug the power plug. After a while, plug it in and turn on the power. Device Disposal When disposing of this product, please follow the instructions(local regulations) of each local government. Specification Main Unit Dimension W74×H207×D51ｍｍ Weight Approx. 290g Input voltage / current DC12V/4A Max. Power consumption Max. 48W Operation Temperature 5ºC ~ 35°C Power Adapter Input AC100-240V 50/60Hz Output DC12V/4A Max. Length approx. 1.8m Power Cable Length Approx. 1.5m Maxell, Ltd. 30-13 Motoyoyogi-Cho, Shibuya-Ku, Tokyo 151-8527 http://www.maxell.co.jp [...]<p><a class="btn btn-secondary understrap-read-more-link" href="https://usemanuals.com/maxell/llexam-pa1777-00/">Read More...</a></p>]]></description>
										<content:encoded><![CDATA[<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/maxell-llexam-LOGO.webp" /><br />
<strong>PA1777-00</strong><br />
<strong>Intense Pulsed Light Device</strong><br />
<strong>MXIP -100</strong></p>
<p><strong>User Manual</strong><br />
Thank you for purchasing Maxell product. Please read the user manual in advance and use the product safely.</p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/maxell-llexam-MXIP.webp" /></p>
<h4>Content of the package</h4>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/maxell-llexam-Content-of-the-package.webp" /></p>
<h4>Introduction</h4>
<p><strong>About the user manual</strong></p>
<ul>
<li>Contents of this user manual might be changed in the future without prior notice.</li>
<li>For product improvement, change of appearance or specification might not be announced in advance.</li>
<li>Except for personal use, any unauthorized copying of part or all parts of this manual is prohibited. Unauthorized republication is strictly prohibited.</li>
</ul>
<p><strong>Disclaimer</strong></p>
<ul>
<li>Maxell shall not be responsible for any damage caused by fires, earthquakes, the action of a third party, any accidents, intended or unintended misuse, or another usage under abnormal conditions.</li>
<li>All explicit and implicit contents not stated in the warranty card are not covered.</li>
<li>Maxell shall not be responsible for failure due to any damage caused by usage other than described in the instruction manual.</li>
<li>This product is not being designed to be any equipment or device which could be concerned with human life such as medical device, nuclear device, astronomic device, transportation device, etc., nor equipment or devices which requires high reliability. In case this product is used for the above equipment and/or systems, Maxell do not responsible for any injuries or fire accidents caused by the failure of this product.</li>
</ul>
<h4>Safety Precaution</h4>
<p>Please strictly follow and use safely.</p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/warning-cion-3.webp" /><strong> Danger</strong><br />
Danger refers to misuse which might lead to death or serious injury *1 to a high degree.<br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/warning-cion-3.webp" /><strong>Warning</strong><br />
The warning refers to misuse which might lead to death or serious injury *1<br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/warning-cion-3.webp" /><strong>Caution<br />
</strong>Caution refers to misuse which might lead to injury *2 or damage *3.</p>
<p>*1: Serious injury refers to blindness or injuries, burnt, electric shock, bone fracture, poisoned or injury with after-effect, or resulted in hospitalization or long-term follow-up consultation.<br />
*2: Injury refers to burnt, electric shock which do not result in hospitalization or long-term follow-up consultation.<br />
*3: Damages refers broad damages to houses or properties and domestic animals/pets.</p>
<table width="1413">
<tbody>
<tr>
<td rowspan="3" width="103">Example of symbols</td>
<td width="94"><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/maxell-llexam-ICON-01.webp" /></td>
<td width="697">Prohibited actions when handling the product.<br />
The shape of <img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/maxell-llexam-ICON-01-1.webp" />graphic symbol that indicates specific notes is shown in black.</td>
</tr>
<tr>
<td><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/maxell-llexam-ICON-02.webp" /></td>
<td>Caution to fire, explosion, high temperature when handling the product.<br />
The shape of<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/maxell-llexam-ICON-02-1.webp" /> graphic symbol that indicates specific notes is shown in black.</td>
</tr>
<tr>
<td><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/maxell-llexam-ICON-03.webp" /></td>
<td>instruction which must be followed when handling the product.<br />
The shape of<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/maxell-llexam-ICON-03-1.webp" /> graphic symbol that indicates specific notes is shown in black.</td>
</tr>
</tbody>
</table>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/warning-cion-3.webp" /><strong> Danger</strong></p>
<p>Those who use electric medical devices implanted in the body such as pacemakers should keep the main unit away from these medical devices<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/maxell-llexam-ICON-01.webp" /><br />
It may cause an accident or poor physical condition.<br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/warning-cion-3.webp" /><strong> Warning<br />
</strong>The following people do not use this device<br />
・Person being treated by a doctor ・People under 18 ・Pregnant or menstruating ・Skin perception disorders ・ People with fever. ・Person with allergies, person who is prone to rashes caused by cosmetics, clothing, metals, etc ・People with acute diseases, tuberculosis, infectious, malignant tumours, etc.・Person with allergies, dermatitis, <img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/maxell-llexam-ICON-01.webp" /> eczema, herpes and other skin diseases ・Person whose skin is sensitive to sunlight ・Those who cannot express their intentions ・People who are recently consumed alcohol. It may cause accidents or physical deterioration.</p>
<p><strong>Do not use in the following areas<br />
</strong>・Sunburned skin ・Dark spots, such as freckles, stains and black moles ・Scabs, cuts, rashes, bruises, warts, pimples, rashes, insect bites ・Skin cancer, ringworm, folliculitis, <img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/maxell-llexam-ICON-01.webp" /> varicose veins ・Hemangiomas ・Cosmetic surgery area ・Around eyes, eyebrows, lips, neck, abdomen (female only), genital parts, back ・Tattoos, and permanent make-up ・ On make-up</p>
<p>Do not use over the area that had peeling treatment. <img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/maxell-llexam-ICON-01.webp" /><br />
It may cause skin trouble.<br />
Do not use directly on eyes<br />
It may damage your eyes.<strong><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/maxell-llexam-ICON-01.webp" /></strong><br />
Do not irradiate on hair or clothes<br />
It may cause burn or deformation.</p>
<p><strong>Do not use perfume or make-up products immediately after the treatment. (Excluding cream or lotion for moisturizing)<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/maxell-llexam-ICON-01.webp" /></strong><br />
It may cause skin trouble.</p>
<p>If you are taking medication continuously, please consult your doctor before use.<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/maxell-llexam-ICON-07.webp" /><br />
It may cause accidents or physical deterioration.<br />
Store in a place out of reach of children <img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/warning-cion-3.webp" /><br />
It may cause burn, electric shock or injury.</p>
<p><strong>If an abnormality occurs, immediately stop using and disconnect the power plug</strong><br />
It may cause smoke, fire, electric shock or injury.<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/maxell-llexam-ICON-04.webp" /><br />
<strong>Do not modify, disassemble or repair</strong><br />
It may cause smoke, electric shock or injury.<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/maxell-llexam-ICON-05.webp" /><br />
<strong>Plug the AC adaptor to AC outlet firmly</strong><br />
Partially plugged AC adaptor may cause to fire or electric shock.<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/maxell-llexam-ICON-07.webp" /></p>
<p><strong>Do not use loose plugs</strong><br />
It may cause electric shock, short circuit or fire.<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/maxell-llexam-ICON-01.webp" /><br />
<strong>Do not use any voltage other than the specified power supply voltage</strong><br />
This may cause electric shock or fire.<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/maxell-llexam-ICON-01.webp" /><br />
The power input of the AC adaptor of this product is AC100~240.</p>
<p>Do not damage, forcibly bend, twist, put heavy objects on, pinch, bundle, or modify the power cable and power adapter<br />
It may cause smoke or fire.<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/maxell-llexam-ICON-01.webp" /></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/warning-cion-3.webp" /><strong> Warning</strong></p>
<p><strong>Do not cover the power adapter with a cloth or a cover</strong><br />
Heat will accumulate and cause deformation of the case, fire or electric shock.<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/maxell-llexam-ICON-01.webp" /><br />
<strong>Do not use a power adapter other than the provided power adapter</strong><br />
This may cause overheat, smoke, fire, malfunction or injury.<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/maxell-llexam-ICON-01.webp" /><br />
<strong>Check whether the main unit is deformed, cracked or damaged before use.</strong><br />
This may cause malfunction or injury.<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/maxell-llexam-ICON-01.webp" /><br />
<strong>Immediately stop use if the main unit dropped or damaged</strong><br />
Continuation of use may cause electric shock, fire or injury.<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/maxell-llexam-ICON-01.webp" /><br />
<strong>Do not use in a dark room</strong><br />
This may damage your eyes.<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/maxell-llexam-ICON-01.webp" /><br />
<strong>Do not look directly or let others look directly at the irradiation window</strong><br />
This may damage your eyes.<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/maxell-llexam-ICON-01.webp" /><br />
<strong>Do not block the air inlet or outlet ports</strong><br />
This may cause overheat, smoke, fire.<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/maxell-llexam-ICON-01.webp" /><br />
<strong>Do not use for any purpose other than that described in the instruction manual</strong><br />
This may cause malfunction, injury.<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/maxell-llexam-ICON-01.webp" /><br />
<strong>Do not use for pets</strong><br />
This may cause burns or injury.<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/maxell-llexam-ICON-01.webp" /><br />
<strong>Do not put into heating appliances such as microwave ovens or pressure cookers</strong><br />
This may cause smoke or fire.<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/maxell-llexam-ICON-01.webp" /><br />
<strong>Do not put into a fire</strong><br />
This may cause overheat, fire or leakage.<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/maxell-llexam-ICON-01.webp" /><br />
<strong>Do not use or store near heating devices such as stoves</strong><br />
This may cause overheat or fire.<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/maxell-llexam-ICON-01.webp" /><br />
<strong>Do not place the product in direct sunlight or outdoor</strong><br />
This may cause malfunction.<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/maxell-llexam-ICON-01.webp" /><br />
<strong>Do not put into refrigerators</strong><br />
This may cause malfunction.<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/maxell-llexam-ICON-01.webp" /><br />
<strong>Do not splash or soak in water</strong><br />
It may cause electric shock or malfunction.<strong><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/maxell-llexam-ICON-01.webp" /></strong><br />
<strong>Do not use with wet hands</strong><br />
This may cause overheat, electric shock or malfunction.<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/maxell-llexam-hands.webp" /><br />
<strong>Do not use the product in a humid place such as the bathroom</strong><br />
This may cause overheat or malfunction.<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/maxell-llexam-place-such.webp" /><br />
<strong>When unplugging the power plug, always hold the plug without pulling the cable</strong><br />
It may cause electric shock, short circuit or fire.<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/maxell-llexam-ICON-07.webp" /><br />
<strong>Always unplug the power plug from the power outlet when cleaning</strong><br />
It may cause electric shock.<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/maxell-llexam-ICON-07.webp" /></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/warning-cion-3.webp" /><strong>Caution</strong></p>
<p><strong>Do not use while wearing wet clothes</strong><br />
This may cause electric shock.<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/maxell-llexam-ICON-01.webp" /><br />
<strong>Do not irradiate the same site repeatedly</strong><br />
This may cause burn or injury<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/maxell-llexam-ICON-01.webp" /><br />
<strong>Do not touch the irradiated site during or immediately after use</strong><br />
This may cause burn<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/maxell-llexam-ICON-01.webp" /><br />
<strong>Do not use while wearing metal ornaments such as necklaces</strong><br />
This may cause malfunction or burn<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/maxell-llexam-ICON-01.webp" /><br />
<strong>Do not drop or throw against something</strong><br />
This may cause malfunction or burn<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/maxell-llexam-ICON-01.webp" /><br />
<strong>Regularly check the irradiation part for contamination</strong><br />
This may cause malfunction or burn<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/maxell-llexam-ICON-07.webp" /><br />
<strong>Unplug the power plug from the power outlet when not in use</strong><br />
This may cause electric shock, smoke, fire.<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/maxell-llexam-ICON-07.webp" /></p>
<h4>Features</h4>
<p>This product is a device that irradiates the skin with light to remove unwanted hair. A cooling plate is installed around the irradiation window to cool down the skin at the same  time as irradiation.<br />
It lessens the pain and heat during irradiation and gently cares for the skin.<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/maxell-llexam-Features.webp" /></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/maxell-llexam-Cooling.webp" /> Cooling Plate<br />
The plate gets cold when the power is turned on.<br />
It cools the skin while irradiating.</p>
<p><img decoding="async" class="attachment-post-thumbnail ezlazyloaded" src="images/21.webp" sizes="" srcset="" alt="maxell llexam --Irradiation" width="219" height="78" data-ezsrcset="https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Irradiation.png?ezimgfmt=ng:webp/ngcb1 410w,https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Irradiation-300x107.png?ezimgfmt=ng:webp/ngcb1 300w" data-ezsrc="https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Irradiation.png?ezimgfmt=rs:219x78/rscb1/ng:webp/ngcb1" /><strong>Irradiation times 500,000times</strong></p>
<p><img decoding="async" class="attachment-post-thumbnail ezlazyloaded" src="images/22.webp" sizes="" srcset="" alt="maxell llexam - 5-Levels" width="203" height="56" data-ezsrcset="https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-5-Levels.png?ezimgfmt=ng:webp/ngcb1 355w,https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-5-Levels-300x83.png?ezimgfmt=ng:webp/ngcb1 300w" data-ezsrc="https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-5-Levels.png?ezimgfmt=rs:203x56/rscb1/ng:webp/ngcb1" /><strong> 5-Levels Output Setting</strong></p>
<p><img decoding="async" class="attachment-post-thumbnail alignleft ezlazyloaded" src="images/23.webp" alt="maxell llexam - Mode" width="108" height="93" data-ezsrc="https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Mode.png?ezimgfmt=rs:108x93/rscb1/ng:webp/ngcb1" /><strong>Mode Switching</strong><br />
<strong>Single Mode:</strong> Irradiate manually each time.<br />
<strong>Continuous Mode:</strong> Automatic continuous irradiation.</p>
<p><img loading="lazy" decoding="async" class="attachment-post-thumbnail alignleft ezlazyloaded" src="images/24.webp" alt="maxell llexam - LCD" width="109" height="73" data-ezsrc="https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-LCD.png?ezimgfmt=rs:109x73/rscb1/ng:webp/ngcb1" /><strong>LCD Display</strong><br />
The remaining irradiation count, output level, mode, and irradiation preparation status can be checked on the LCD display.</p>
<p><img loading="lazy" decoding="async" class="attachment-post-thumbnail alignleft ezlazyloaded" src="images/25.webp" sizes="auto, " srcset="" alt="" width="63" height="64" data-ezsrcset="https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Skin.png?ezimgfmt=ng:webp/ngcb1 167w,https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Skin-120x120.png?ezimgfmt=ng:webp/ngcb1 120w" data-ezsrc="https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Skin.png?ezimgfmt=rs:63x64/rscb1/ng:webp/ngcb1" /><strong> Skin Detection Sensor</strong><br />
Sensors on both sides of the irradiation window. When the sensor detects skin contact, the device can irradiate.</p>
<p><img loading="lazy" decoding="async" class="attachment-post-thumbnail alignleft ezlazyloaded" src="images/26.webp" sizes="auto, " srcset="" alt="maxell llexam - Auto" width="76" height="76" data-ezsrcset="https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Auto.png?ezimgfmt=ng:webp/ngcb1 155w,https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Auto-150x150.png?ezimgfmt=ng:webp/ngcb1 150w,https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Auto-120x120.png?ezimgfmt=ng:webp/ngcb1 120w" data-ezsrc="https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Auto.png?ezimgfmt=rs:76x76/rscb1/ng:webp/ngcb1" /><strong>Auto-oﬀ Function</strong><br />
If there is no operation for 3 minutes with the power on, the power will turn off automatically.</p>
<h4>Part Names</h4>
<p><img loading="lazy" decoding="async" class="attachment-post-thumbnail aligncenter ezlazyloaded" src="images/27.webp" sizes="auto, " srcset="" alt="maxell llexam - Part Names" width="845" height="766" data-ezsrcset="https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Part-Names.png?ezimgfmt=ng:webp/ngcb1 820w,https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Part-Names-300x272.png?ezimgfmt=ng:webp/ngcb1 300w,https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Part-Names-768x696.png?ezimgfmt=ng:webp/ngcb1 768w" data-ezsrc="https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Part-Names.png?ezimgfmt=rs:612x555/rscb1/ng:webp/ngcb1" /><img loading="lazy" decoding="async" class="attachment-post-thumbnail aligncenter ezlazyloaded" src="images/28.webp" sizes="auto, " srcset="" alt="maxell llexam -Part Names-" width="948" height="382" data-ezsrcset="https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Part-Names-.png?ezimgfmt=ng:webp/ngcb1 974w,https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Part-Names--300x121.png?ezimgfmt=ng:webp/ngcb1 300w,https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Part-Names--768x309.png?ezimgfmt=ng:webp/ngcb1 768w" data-ezsrc="https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Part-Names-.png?ezimgfmt=rs:612x246/rscb1/ng:webp/ngcb1" /></p>
<h4>Recommended Treatment Area</h4>
<p>The time is an approximate time when used at level 1.</p>
<p><img loading="lazy" decoding="async" class="attachment-post-thumbnail aligncenter ezlazyloaded" src="images/29.webp" sizes="auto, " srcset="" alt="maxell llexam -Recommended" width="713" height="851" data-ezsrcset="https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Recommended.png?ezimgfmt=ng:webp/ngcb1 671w,https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Recommended-251x300.png?ezimgfmt=ng:webp/ngcb1 251w" data-ezsrc="https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Recommended.png?ezimgfmt=rs:612x731/rscb1/ng:webp/ngcb1" /><img loading="lazy" decoding="async" class="attachment-post-thumbnail aligncenter ezlazyloaded" src="images/30.webp" sizes="auto, " srcset="" alt="maxell llexam -Areas that can be irradiated" width="712" height="894" data-ezsrcset="https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Areas-that-can-be-irradiated.png?ezimgfmt=ng:webp/ngcb1 699w,https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Areas-that-can-be-irradiated-239x300.png?ezimgfmt=ng:webp/ngcb1 239w" data-ezsrc="https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Areas-that-can-be-irradiated.png?ezimgfmt=rs:612x768/rscb1/ng:webp/ngcb1" /></p>
<h4>Frequency of Use</h4>
<p><img loading="lazy" decoding="async" class="attachment-post-thumbnail ezlazyloaded" src="images/31.webp" alt="maxell llexam - week" width="99" height="93" data-ezsrc="https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-week.png?ezimgfmt=rs:99x93/rscb1/ng:webp/ngcb1" /></p>
<table width="558">
<tbody>
<tr>
<td width="241">week First 1~4</td>
<td width="697">1 week  once</td>
</tr>
<tr>
<td>week 5~8</td>
<td>1 or 2 weeks once</td>
</tr>
<tr>
<td>week 9~12</td>
<td>2 weeks or 1 month once</td>
</tr>
</tbody>
</table>
<p>If hair growth is no longer seen, it is not necessary to perform the treatment as often as above.<br />
If hair becomes visible again, perform the treatment as needed.</p>
<p><strong>Caution</strong><br />
・The efiect depends on the area of use and personal constitution.<br />
・Do not exceed the above frequency of use.</p>
<h4>Preparation before use</h4>
<p><strong>Check the skin and hair color</strong><br />
Please check the attached color chart.<br />
<img loading="lazy" decoding="async" class="attachment-post-thumbnail size-post-thumbnail aligncenter ezlazyloaded" src="images/32.webp" sizes="auto, " srcset="" alt="maxell llexam - Check the skin" width="640" height="255" data-ezsrcset="https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Check-the-skin.png?ezimgfmt=ng:webp/ngcb1 729w,https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Check-the-skin-300x119.png?ezimgfmt=ng:webp/ngcb1 300w" data-ezsrc="https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Check-the-skin.png?ezimgfmt=rs:612x243/rscb1/ng:webp/ngcb1" />Remove make-ups<br />
Use on bare skin (Remove all make-up, lotion, cream and perfume)<br />
It may cause skin trouble if used on make-up.<br />
<img loading="lazy" decoding="async" class="attachment-post-thumbnail size-post-thumbnail aligncenter ezlazyloaded" src="images/33.webp" sizes="auto, " srcset="" alt="maxell llexam - make-ups" width="290" height="472" data-ezsrcset="https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-make-ups.png?ezimgfmt=ng:webp/ngcb1 290w,https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-make-ups-184x300.png?ezimgfmt=ng:webp/ngcb1 184w" data-ezsrc="https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-make-ups.png?ezimgfmt=rs:290x472/rscb1/ng:webp/ngcb1" /><strong>Removing hair</strong><br />
Be sure to remove hair before using. Hair growth or hair remaining on the skin surface can cause burns. Please do not remove the hair from the root, such as waxing or pulling out hair with a tweezer.<br />
<img loading="lazy" decoding="async" class="attachment-post-thumbnail aligncenter ezlazyloaded" src="images/34.webp" sizes="auto, " srcset="" alt="maxell llexam - Removing" width="377" height="410" data-ezsrcset="https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Removing.png?ezimgfmt=ng:webp/ngcb1 522w,https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Removing-276x300.png?ezimgfmt=ng:webp/ngcb1 276w" data-ezsrc="https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Removing.png?ezimgfmt=rs:377x410/rscb1/ng:webp/ngcb1" />Remove the protective film attached to the display.</p>
<p><img loading="lazy" decoding="async" class="attachment-post-thumbnail size-post-thumbnail aligncenter ezlazyloaded" src="images/35.webp" alt="" width="285" height="280" data-ezsrc="https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-protective.png?ezimgfmt=rs:285x280/rscb1/ng:webp/ngcb1" /><strong>Allergy Test</strong><br />
When using for the first time, or has not used for a period of time, please perform an allergy test to make sure that no skin trouble occurs. (See P.10 for how to use)</p>
<ol>
<li>Irradiate the  area where you want to use once with output level 1.</li>
<li>After 48 hours, check the tested area for any abnormalities.<br />
Please consult your doctor if any abnormalities are seen such as redness</li>
</ol>
<p><strong>Caution</strong><br />
・Do not irradiate the allergy-tested area within a week.<br />
・Stop using if skin irritation occurs (such as redness) and consult a dermatologist if irritation continues after 2 days.</p>
<h4>Operating Instructions</h4>
<p>Caution<br />
・Please keep the room bright when using.・Storage light will be generated when irradiating, please make sure that there are no people or pets nearby.・Strong light is emitted  during use. Be careful not to look directly at the area of use. • When using on face, please close your eyes.</p>
<ol>
<li><strong>Connect Power</strong><br />
<img loading="lazy" decoding="async" class="attachment-post-thumbnail aligncenter ezlazyloaded" src="images/36.webp" sizes="auto, " srcset="" alt="maxell llexam - Connect Power" width="800" height="215" data-ezsrcset="https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Connect-Power.png?ezimgfmt=ng:webp/ngcb1 1384w,https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Connect-Power-300x81.png?ezimgfmt=ng:webp/ngcb1 300w,https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Connect-Power-1024x276.png?ezimgfmt=ng:webp/ngcb1 1024w,https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Connect-Power-768x207.png?ezimgfmt=ng:webp/ngcb1 768w" data-ezsrc="https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Connect-Power.png?ezimgfmt=rs:590x159/rscb1/ng:webp/ngcb1" /></li>
<li><strong>Turn on the Power</strong><br />
<img loading="lazy" decoding="async" class="attachment-post-thumbnail aligncenter ezlazyloaded" src="images/37.webp" sizes="auto, " srcset="" alt="maxell llexam - Turn on the" width="348" height="406" data-ezsrcset="https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Turn-on-the.png?ezimgfmt=ng:webp/ngcb1 450w,https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Turn-on-the-257x300.png?ezimgfmt=ng:webp/ngcb1 257w" data-ezsrc="https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Turn-on-the.png?ezimgfmt=rs:348x406/rscb1/ng:webp/ngcb1" />Press and hold the power button (for 2 seconds) to turn on the power. A beep sounds and the display lights up. When the power is turned on, the setting is single-mode and output is level 1.<br />
<img loading="lazy" decoding="async" class="attachment-post-thumbnail size-post-thumbnail aligncenter ezlazyloaded" src="images/38.webp" sizes="auto, " srcset="" alt="maxell llexam - Display" width="640" height="242" data-ezsrcset="https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Display.png?ezimgfmt=ng:webp/ngcb1 683w,https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Display-300x113.png?ezimgfmt=ng:webp/ngcb1 300w" data-ezsrc="https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Display.png?ezimgfmt=rs:590x223/rscb1/ng:webp/ngcb1" /></li>
<li>Switch Output Level<br />
<img loading="lazy" decoding="async" class="attachment-post-thumbnail aligncenter ezlazyloaded" src="images/39.webp" sizes="auto, " srcset="" alt="maxell llexam -Level" width="354" height="435" data-ezsrcset="https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Level.png?ezimgfmt=ng:webp/ngcb1 430w,https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Level-244x300.png?ezimgfmt=ng:webp/ngcb1 244w" data-ezsrc="https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Level.png?ezimgfmt=rs:354x435/rscb1/ng:webp/ngcb1" />The output level can be switched by short pressing the power button. Select the output level you are using.<br />
※If you are using the device for the first time, we recommend that you start from output level 1.<img loading="lazy" decoding="async" class="attachment-post-thumbnail size-post-thumbnail aligncenter ezlazyloaded" src="images/40.webp" sizes="auto, " srcset="" alt="maxell llexam - output" width="456" height="473" data-ezsrcset="https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-output.png?ezimgfmt=ng:webp/ngcb1 456w,https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-output-289x300.png?ezimgfmt=ng:webp/ngcb1 289w" data-ezsrc="https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-output.png?ezimgfmt=rs:456x473/rscb1/ng:webp/ngcb1" /></li>
<li><strong><strong>Switch the mode</strong></strong><br />
<img loading="lazy" decoding="async" class="attachment-post-thumbnail aligncenter ezlazyloaded" src="images/37.webp" sizes="auto, " srcset="" alt="maxell llexam - Turn on the" width="348" height="406" data-ezsrcset="https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Turn-on-the.png?ezimgfmt=ng:webp/ngcb1 450w,https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Turn-on-the-257x300.png?ezimgfmt=ng:webp/ngcb1 257w" data-ezsrc="https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Turn-on-the.png?ezimgfmt=rs:348x406/rscb1/ng:webp/ngcb1" /><br />
The mode can be switched by long pressing the multi button (for 2 seconds). Select the mode to use.<br />
<strong>Single Mode</strong><br />
<img loading="lazy" decoding="async" class="attachment-post-thumbnail size-post-thumbnail ezlazyloaded" src="images/41.webp" alt="maxell llexam -Single Mode" width="43" height="64" data-ezsrc="https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Single-Mode.png?ezimgfmt=rs:43x64/rscb1/ng:webp/ngcb1" /><br />
When you want to perform a treatment for a small area or sensitive area<br />
<strong>Continuous irradiation mode</strong><br />
When you want to effciently care for a wide area<br />
<img loading="lazy" decoding="async" class="attachment-post-thumbnail ezlazyloaded" src="images/42.webp" alt="maxell llexam - Continuous" width="60" height="57" data-ezsrc="https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Continuous.png?ezimgfmt=rs:60x57/rscb1/ng:webp/ngcb1" /><br />
*Continuous mode is a mode of continuously irradiated with preset output level.<br />
*The level cannot be changed in continuous mode.</li>
</ol>
<p>For each mode, see the mode description below to use .<br />
<img loading="lazy" decoding="async" class="attachment-post-thumbnail size-post-thumbnail ezlazyloaded" src="images/41.webp" alt="maxell llexam -Single Mode" width="43" height="64" data-ezsrc="https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Single-Mode.png?ezimgfmt=rs:43x64/rscb1/ng:webp/ngcb1" /><strong>Single Mode<br />
</strong></p>
<ol>
<li><strong>Press against the area you want to use.</strong><br />
<img loading="lazy" decoding="async" class="attachment-post-thumbnail size-post-thumbnail aligncenter ezlazyloaded" src="images/43.webp" sizes="auto, " srcset="" alt="" width="487" height="206" data-ezsrcset="https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Press-against.png?ezimgfmt=ng:webp/ngcb1 487w,https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Press-against-300x127.png?ezimgfmt=ng:webp/ngcb1 300w" data-ezsrc="https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Press-against.png?ezimgfmt=rs:487x206/rscb1/ng:webp/ngcb1" />Make sure there is no gap between the irradiation window and the area you want to irradiate.<br />
The display flashes while the skin detection sensor is in contact with the skin.<br />
<strong>*If the skin detection sensor is not in contact with the skin, the device cannot irradiate.</strong><br />
<img loading="lazy" decoding="async" class="attachment-post-thumbnail size-post-thumbnail aligncenter ezlazyloaded" src="images/44.webp" sizes="auto, " srcset="" alt="maxell llexam - Continuous-" width="453" height="209" data-ezsrcset="https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Continuous-.png?ezimgfmt=ng:webp/ngcb1 453w,https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Continuous--300x138.png?ezimgfmt=ng:webp/ngcb1 300w" data-ezsrc="https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Continuous-.png?ezimgfmt=rs:453x209/rscb1/ng:webp/ngcb1" /></li>
<li><strong>Ready for irradiation</strong><br />
<img loading="lazy" decoding="async" class="attachment-post-thumbnail size-post-thumbnail aligncenter ezlazyloaded" src="images/45.webp" alt="" width="202" height="250" data-ezsrc="https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Ready-for.png?ezimgfmt=rs:202x250/rscb1/ng:webp/ngcb1" />Irradiation is ready when the entire display flashes.<br />
<img loading="lazy" decoding="async" class="attachment-post-thumbnail size-post-thumbnail aligncenter ezlazyloaded" src="images/46.webp" sizes="auto, " srcset="" alt="maxell llexam - Flashing" width="640" height="168" data-ezsrcset="https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Flashing.png?ezimgfmt=ng:webp/ngcb1 710w,https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Flashing-300x79.png?ezimgfmt=ng:webp/ngcb1 300w" data-ezsrc="https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Flashing.png?ezimgfmt=rs:590x155/rscb1/ng:webp/ngcb1" /></li>
<li><strong>Irradiation</strong><img loading="lazy" decoding="async" class="attachment-post-thumbnail size-post-thumbnail aligncenter ezlazyloaded" src="images/47.webp" sizes="auto, " srcset="" alt="maxell llexam - Irradiation" width="352" height="249" data-ezsrcset="https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Irradiation-1.png?ezimgfmt=ng:webp/ngcb1 352w,https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Irradiation-1-300x212.png?ezimgfmt=ng:webp/ngcb1 300w" data-ezsrc="https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Irradiation-1.png?ezimgfmt=rs:352x249/rscb1/ng:webp/ngcb1" />It irradiates when the multi-button is pressed.<br />
<img loading="lazy" decoding="async" class="attachment-post-thumbnail size-post-thumbnail aligncenter ezlazyloaded" src="images/48.webp" sizes="auto, " srcset="" alt="maxell llexam - irradiates" width="370" height="265" data-ezsrcset="https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-irradiates.png?ezimgfmt=ng:webp/ngcb1 370w,https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-irradiates-300x215.png?ezimgfmt=ng:webp/ngcb1 300w" data-ezsrc="https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-irradiates.png?ezimgfmt=rs:370x265/rscb1/ng:webp/ngcb1" /></li>
<li><strong>Repeat irradiation</strong><br />
Move the irradiation position and repeat steps❶ to ❸ The irradiation interval is approx. 1 to 3 seconds. It depends on the output level.<br />
<img loading="lazy" decoding="async" class="attachment-post-thumbnail size-post-thumbnail aligncenter ezlazyloaded" src="images/49.webp" sizes="auto, " srcset="" alt="maxell llexam -Move the irradiation" width="609" height="217" data-ezsrcset="https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Move-the-irradiation.png?ezimgfmt=ng:webp/ngcb1 609w,https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Move-the-irradiation-300x107.png?ezimgfmt=ng:webp/ngcb1 300w" data-ezsrc="https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Move-the-irradiation.png?ezimgfmt=rs:590x210/rscb1/ng:webp/ngcb1" /></li>
</ol>
<p><img loading="lazy" decoding="async" class="attachment-post-thumbnail ezlazyloaded" src="images/42.webp" alt="maxell llexam - Continuous" width="60" height="57" data-ezsrc="https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Continuous.png?ezimgfmt=rs:60x57/rscb1/ng:webp/ngcb1" /><strong>Continuous Mode</strong></p>
<ol>
<li>Press against the area you want to use<br />
<strong><img loading="lazy" decoding="async" class="attachment-post-thumbnail size-post-thumbnail aligncenter ezlazyloaded" src="images/50.webp" sizes="auto, " srcset="" alt="" width="437" height="216" data-ezsrcset="https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Press-against-.png?ezimgfmt=ng:webp/ngcb1 437w,https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Press-against--300x148.png?ezimgfmt=ng:webp/ngcb1 300w" data-ezsrc="https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Press-against-.png?ezimgfmt=rs:437x216/rscb1/ng:webp/ngcb1" /><br />
</strong>Make sure there is no gap between the irradiation window and the area you want to irradiate.<br />
※If the skin detection sensor is not in contact with the skin, the device cannot irradiate.<br />
<img loading="lazy" decoding="async" class="attachment-post-thumbnail size-post-thumbnail aligncenter ezlazyloaded" src="images/51.webp" sizes="auto, " srcset="" alt="maxell llexam - Make sure there" width="467" height="216" data-ezsrcset="https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Make-sure-there.png?ezimgfmt=ng:webp/ngcb1 467w,https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Make-sure-there-300x139.png?ezimgfmt=ng:webp/ngcb1 300w" data-ezsrc="https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Make-sure-there.png?ezimgfmt=rs:467x216/rscb1/ng:webp/ngcb1" /></li>
<li><strong>Irradiate automatically</strong><br />
When the skin detection sensor detects the skin, irradiation will start immediately.</li>
<li><strong>Repeat irradiation</strong><br />
Slide the main unit at the same speed.<br />
Be careful not to overlap the irradiated area.<br />
The irradiation interval is about 1 to 3 seconds. It depends on the output level.<br />
<img loading="lazy" decoding="async" class="attachment-post-thumbnail size-post-thumbnail aligncenter ezlazyloaded" src="images/52.webp" sizes="auto, " srcset="" alt="maxell llexam -Slide the main" width="615" height="217" data-ezsrcset="https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Slide-the-main.png?ezimgfmt=ng:webp/ngcb1 615w,https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Slide-the-main-300x106.png?ezimgfmt=ng:webp/ngcb1 300w" data-ezsrc="https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Slide-the-main.png?ezimgfmt=rs:590x208/rscb1/ng:webp/ngcb1" /></li>
</ol>
<p><strong>Cool-down Function</strong><br />
When the temperature inside the main unit rises, it stops operating and cools down for 20 seconds.<br />
※the timing to cool down depends on the output level and the surrounding environment.<br />
<img loading="lazy" decoding="async" class="attachment-post-thumbnail size-post-thumbnail aligncenter ezlazyloaded" src="images/53.webp" sizes="auto, " srcset="" alt="maxell llexam -Function" width="331" height="108" data-ezsrcset="https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Function.png?ezimgfmt=ng:webp/ngcb1 331w,https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Function-300x98.png?ezimgfmt=ng:webp/ngcb1 300w" data-ezsrc="https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Function.png?ezimgfmt=rs:331x108/rscb1/ng:webp/ngcb1" /><strong>5. Finish</strong></p>
<p><strong><strong><img loading="lazy" decoding="async" class="attachment-post-thumbnail size-post-thumbnail aligncenter ezlazyloaded" src="images/54.webp" sizes="auto, " srcset="" alt="maxell llexam -Finish" width="404" height="324" data-ezsrcset="https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Finish.png?ezimgfmt=ng:webp/ngcb1 404w,https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Finish-300x241.png?ezimgfmt=ng:webp/ngcb1 300w" data-ezsrc="https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Finish.png?ezimgfmt=rs:404x324/rscb1/ng:webp/ngcb1" /></strong></strong></p>
<p>Press and hold the power button (for 2 seconds) to turn off the power.<br />
Unplug the power plug from the power outlet.<br />
※When the power is turned off, the temperature inside the main body is transmitted to the cooling plate, which may cause the cooling plate to become warm.<br />
Allow time for it to cool down before cleaning.</p>
<p><strong>Caution</strong></p>
<ul>
<li>As the level gets higher, more heat is felt. However, it is not abnormal.</li>
<li>Smoke and odor may occur due to the burning of hair during use.</li>
<li>Do not continuously irradiate at the same area.</li>
<li>This product has a cooling function as being used, however, if you are concerned about the heat of your skin or burning sensation or redness, cool the skin down with a towel soaked with cold water, etc.</li>
<li>If you experience severe pain, stop using immediately.</li>
</ul>
<p><strong>Caution</strong></p>
<ul>
<li>If an irradiation error occurs, “E30” is displayed and the operation will stop for 30 seconds.</li>
<li>If there is no operation for 3 minutes with the power on, the power will turn off automatically.</li>
<li>Do not leave it plugged in after use.</li>
<li>Depending on the ambient temperature, the cooling plate may not cool suficiently and may not feel cold.</li>
</ul>
<h4>Maintenance</h4>
<ul>
<li>Always stop operation and unplug the power plug from the power outlet when cleaning.</li>
<li>Just after use, the irradiation window and cooling plate will still keep the temperature, so please cool down a little before cleaning.</li>
<li>Gently wipe off the irradiation window, cooling plate, and main unit with a dry cloth.</li>
</ul>
<p>For parts that are dificult to wipe, wipe them gently with a cotton swab.<img loading="lazy" decoding="async" class="attachment-post-thumbnail size-post-thumbnail aligncenter ezlazyloaded" src="images/55.webp" sizes="auto, " srcset="" alt="maxell llexam - Maintenance" width="640" height="301" data-ezsrcset="https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Maintenance.png?ezimgfmt=ng:webp/ngcb1 836w,https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Maintenance-300x141.png?ezimgfmt=ng:webp/ngcb1 300w,https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Maintenance-768x361.png?ezimgfmt=ng:webp/ngcb1 768w" data-ezsrc="https://manuals.plus/wp-content/uploads/2021/08/maxell-llexam-Maintenance.png?ezimgfmt=rs:612x288/rscb1/ng:webp/ngcb1" /></p>
<p><strong>Caution</strong></p>
<ul>
<li>This product is not waterproof. Do not soak it in water or splash it with water.</li>
<li>Do not use chemicals such as benzine, thinner, and alcohol.</li>
</ul>
<h4>Troubleshooting (when problem arise)</h4>
<table width="1350">
<tbody>
<tr>
<td width="181"><strong>Problem</strong></td>
<td width="364"><strong>Cause</strong></td>
<td width="495"><strong>Solution</strong></td>
</tr>
<tr>
<td rowspan="3" width="181"><strong>The display is not </strong><strong>showing</strong></td>
<td width="364">Power is off</td>
<td width="495">Connect the power adapter and power cable securely</td>
</tr>
<tr>
<td width="364">Not using a dedicated power adapter</td>
<td width="495">Use the provided power adapter and cable</td>
</tr>
<tr>
<td width="364">The time to press and hold the power button is too short</td>
<td width="495">Press and hold the power button (for 2 seconds)</td>
</tr>
<tr>
<td rowspan="2" width="181"><strong>Not irradiating</strong></td>
<td width="364">The skin detection sensor is not responding</td>
<td width="495">Both skin detection sensors should be in contact with the skin</td>
</tr>
<tr>
<td width="364">The remaining counts of irradiation are insufficient</td>
<td width="495">The number of counts of irradiations that can be used is 500,000</td>
</tr>
<tr>
<td width="181"><strong>Cannot switch </strong><strong>modes</strong></td>
<td width="364">The time to press and hold the multi-button is too short</td>
<td width="495">Press and hold the multi button (for 2 seconds)</td>
</tr>
<tr>
<td width="181"><strong>Cannot switch levels</strong></td>
<td width="364">The mode is set to continuous irradiation mode</td>
<td width="495">Press and hold the multi-button (for 2 seconds) to switch to single mode</td>
</tr>
<tr>
<td rowspan="2" width="181"><strong>Power turns off</strong></td>
<td width="364">Not operating for 3 minutes</td>
<td width="495">The auto-off function is working</td>
</tr>
<tr>
<td width="364">There is an error</td>
<td width="495">Unplug the power plug and wait a while Insert the power plug and turn on the power</td>
</tr>
<tr>
<td width="181"><strong>The cooldown function is repeated frequently</strong></td>
<td width="364">It is used continuously for a long period of time and the inside the main body is generating heat</td>
<td width="495">Stop using the device for a while until it reaches room temperature</td>
</tr>
<tr>
<td width="181"><strong>The cooling plate is </strong><strong>wet during use</strong></td>
<td width="364">Condensation on the cooling plate</td>
<td width="495">It is not abnormal</p>
<p>If you are concerned, wipe it off before using</td>
</tr>
<tr>
<td width="181"><strong>Cooling plate does </strong><strong>not cool</strong></td>
<td width="364">The ambient temperature is too high</td>
<td width="495">Please use within the operating temperature range</td>
</tr>
</tbody>
</table>
<p>If the symptom does not improve, unplug the power plug. After a while, plug it in and turn on the power.</p>
<h4>Device Disposal</h4>
<p>When disposing of this product, please follow the instructions(local regulations) of each local government.</p>
<h4>Specification</h4>
<table width="838">
<tbody>
<tr>
<td rowspan="5" width="301">Main Unit</td>
<td width="241">Dimension</td>
<td width="296">W74×H207×D51ｍｍ</td>
</tr>
<tr>
<td>Weight</td>
<td>Approx. 290g</td>
</tr>
<tr>
<td>Input voltage / current</td>
<td>DC12V/4A Max.</td>
</tr>
<tr>
<td>Power consumption</td>
<td>Max. 48W</td>
</tr>
<tr>
<td>Operation Temperature</td>
<td width="296">5ºC ~ 35°C</td>
</tr>
<tr>
<td rowspan="3">Power Adapter</td>
<td>Input</td>
<td>AC100-240V 50/60Hz</td>
</tr>
<tr>
<td>Output</td>
<td>DC12V/4A Max.</td>
</tr>
<tr>
<td>Length</td>
<td>approx. 1.8m</td>
</tr>
<tr>
<td>Power Cable</td>
<td>Length</td>
<td>Approx. 1.5m</td>
</tr>
</tbody>
</table>
<p>Maxell, Ltd.<br />
30-13 Motoyoyogi-Cho, Shibuya-Ku, Tokyo 151-8527<br />
<a href="http://www.maxell.co.jp/" target="_blank" rel="noopener">http://www.maxell.co.jp</a></p>
<form id="commentform" class="comment-form" action="https://manuals.plus/wp-comments-post.php" method="post" novalidate="">
<p class="form-submit">
</form>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>

<!--
Performance optimized by W3 Total Cache. Learn more: https://www.boldgrid.com/w3-total-cache/

Page Caching using Disk: Enhanced 

Served from: usemanuals.com @ 2026-07-27 05:39:41 by W3 Total Cache
-->