Thank you for buying the Kinetik Wellbeing Heart Rate Monitor.
At Kinetik Wellbeing our mission is for every home to own affordable healthcare products that help people to manage their wellbeing. Taking regular exercise and increasing your heart rate above its resting level can help to lower blood pressure, improve your circulation and strengthen your heart and lower your risk of heart disease.
The Kinetik Wellbeing Heart Rate Monitor is designed to keep a check on your heart rate during physical activities.
If you are concerned or in any doubt about your fitness levels or heart rate, always consult your doctor. If you are embarking on a change of lifestyle, diet or exercise regime you should always consult with a healthcare professional before doing so.
Before using the Kinetik Watch and Heart Rate Monitor, please read the instructions included in this user manual.
MODE
ADJUST/LIGHT
START/STOP
RESET
Follow steps 1. through 4. to wear the chest belt and go for a run.
In TIME mode you can set the Time, Date, and Hour Format.
Follow steps 1. through 5. to set the time and date.
PRINCIPLE OF THE HEART RATE ZONE
It is important that you know your maximum heart rate, training zone, upper heart rate limit and lower heart rate limit before you begin. They help you achieve the maximum health benefits out of your workout. We recommend consulting a medical practitioner or registered physician before setting your personal training-schedule and target. Or you can set your own upper and lower limit
using the following as a reference guide: Calculation of Maximum Heart Rate: Male = 220 – Age, Female = 226 – Age
Getting Started
Follow steps 1. through 3. to get ready and start your run.
The exercise time is displayed under the heart rate by default. Press the START/STOP key to view other information.
Your heart rate is measured in beats per minute (bpm) and setting a heart rate zone allows you to work with an upper and lower heart rate limit. Follow steps 1. through 6. to adjust the User Settings.
This is an alternative to check your heart rate zones based on gender, age and weight. Starting with your Max Heart Rate (MHR), use the chart to calculate your zones depending on the intensity of your workout. Please note that this chart may not be suitable for everyone.
Max Heart Rate
Male=220-Age
Female=226-Age
Level 1(55-70%)
Sustain a healthy heart and lose weight
Level 2(70-80%)
Develop endurance and increase stamina
Level 3(80-100%)
Sustain excellent fitness condition and increase muscle strength
Age | Male | Female | Male | Female | Male | Female | Male | Female | ||||||
20 | 200 | 206 | 110 | 140 | 113 | 144 | 140 | 160 | 144 | 164 | 160 | 200 | 164 | 206 |
25 | 195 | 201 | 107 | 136 | 110 | 140 | 136 | 156 | 140 | 160 | 156 | 195 | 160 | 201 |
30 | 190 | 196 | 104 | 133 | 107 | 137 | 133 | 152 | 137 | 156 | 152 | 190 | 156 | 196 |
35 | 185 | 191 | 101 | 129 | 105 | 133 | 139 | 148 | 133 | 152 | 148 | 185 | 152 | 191 |
40 | 180 | 186 | 99 | 126 | 102 | 130 | 126 | 144 | 130 | 148 | 144 | 180 | 148 | 186 |
45 | 175 | 181 | 96 | 122 | 99 | 126 | 122 | 140 | 126 | 144 | 140 | 175 | 144 | 181 |
50 | 170 | 176 | 93 | 119 | 96 | 123 | 119 | 136 | 123 | 140 | 136 | 170 | 140 | 176 |
55 | 165 | 171 | 90 | 115 | 94 | 119 | 115 | 132 | 119 | 136 | 132 | 165 | 136 | 171 |
60 | 160 | 166 | 88 | 112 | 91 | 116 | 112 | 128 | 116 | 132 | 128 | 160 | 132 | 166 |
65 | 155 | 161 | 85 | 108 | 88 | 112 | 108 | 124 | 112 | 128 | 124 | 155 | 128 | 161 |
70 | 150 | 156 | 82 | 105 | 85 | 109 | 105 | 120 | 109 | 124 | 120 | 150 | 124 | 156 |
75 | 145 | 151 | 79 | 101 | 83 | 105 | 101 | 116 | 105 | 120 | 116 | 145 | 120 | 151 |
In DATA mode you can view your stored data from the last session.
Follow steps 1. through 2. to manage your data. *Please note only one session worth of data can be stored.
In ALARM mode you can toggle ON/OFF for the alarm and adjust the time.
Follow steps 1. through 5. to adjust alarm settings.
In stopwatch mode, you can measure the amount of time elapsed from a particular time that the watch is activated to the time that the watch is deactivated. Follow steps 1. through 3. to use the stopwatch.
If you want a split time, start the timer and then press the reset button. The watch will continue to measure the amount of time that has passed. To see the time elapsed, press the start button until the timer is live again.
Heart rate doesn’t display on watch
Heart rate reading on watch is inconsistent or stops
Watch beeps continuously
Watch display may be frozen due to static electricity
Product may be returned if faulty, please contact the Retailer or Kinetik directly if you’re experiencing issues with your product. This does not affect your statutory rights. Please note the retailer’s own return policy may still be valid, contact the retailer for more information.
Avoid extreme force, shock, dust temperature, or humidity. Such conditions may cause malfunctioning, a shorter electronic lift span, damaged batteries, or distorted parts.
Rinse the watch with fresh water to avoid materials building up that can interfere with the reception of the pulse.
Do not use abrasive or corrosive materials to clean the watch or chest belt. Abrasive cleaning agents may scratch the plastic parts and corrode the electronic circuit.
Avoid tampering the internal components of the watch. Doing so will terminate the sensors warranty and may cause damage.
When will the Heart Rate Monitor make an audible alert?
How to turn off the beep.
To turn off the beep on the Heart Rate Monitor follow steps 1. through 3.
To reset the watch, press all 4 buttons at the same time. The watch will show the below screen.
Note: When resetting the watch, you will lose all data and personal settings (time, date, heart rate modes, alarm) will revert to factory mode
WE STRONGLY RECOMMEND TAKING YOUR WATCH TO A LOCAL RETAILER OR JEWELLER TO HAVE THE BATTERY REPLACED TO AVOID THE POSSIBILITY OF PERMANENTLY DAMAGING THE WATCH.
WATCH
Water Resistance: 1 ATM Suitable for everyday use.
Splash/rain resistant. NOT suitable for showering, bathing, swimming, snorkelling, water related work and fishing. Water damage will occur if watch buttons are pressed under water. Please dry after use.
Operating Temperatures: -5 to 50 degree Celsius.
Material Specifications:
Crystal: Acrylic Case: Acrylonitrile butadiene styrene (ABS)
Keys: Acrylonitrile butadiene styrene (ABS) Polyurethane
Buckle: Stainless Steel Bezel: Stainless Steel
Caseback: Stainless Steel Strap: Polyurethane
Mode Limits: Heart Rate 30-240bpm
Harvard Medical Devices Ltd.
Unit 1002, 10th Floor, Railway Plaza,
39 Chatham Road South, Tsimshatsui,
Kowloon, Hong Kong.
for more information visit :
kinetikwellbeing.com