<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>GIMA &#8211; UseManuals</title>
	<atom:link href="http://usemanuals.com/gima/feed/" rel="self" type="application/rss+xml" />
	<link>https://usemanuals.com</link>
	<description>Owner&#039;s manuals for all sorts of products</description>
	<lastBuildDate>Mon, 11 Sep 2023 09:07:41 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.7.2</generator>

<image>
	<url>https://usemanuals.com/wp-content/uploads/2025/02/favicon-32x32-2.png</url>
	<title>GIMA &#8211; UseManuals</title>
	<link>https://usemanuals.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>GIMA Watch for Nurses Manual</title>
		<link>https://usemanuals.com/gima/watch-for-nurses/</link>
		
		<dc:creator><![CDATA[ItsManual]]></dc:creator>
		<pubDate>Wed, 16 Aug 2023 07:38:33 +0000</pubDate>
				<category><![CDATA[GIMA]]></category>
		<guid isPermaLink="false">https://usemanuals.com/?p=200734</guid>

					<description><![CDATA[Watch for Nurses PROFESSIONAL MEDICAL PRODUCTS Gima S.p.A. Via Marconi, 1 – 20060 Gessate (MI) Italy gima@gimaitaly.com – export@gimaitaly.com www.gimaitaly.com WATCH FOR NURSES ATTENTION: The operators must carefully read and completely understand the present manual before using the product. AVIS: 20400 – 20401 – 20402 – 20403 – 20404 – 20405 – 20420 20421 – 20422 – 20423 – 20424 – 20425 – 20410 – 20411 20455 – 20460 – 20461 – 20462 – 20463 – 20464 – 20465 Imported by: Gima S.p.A. Via Marconi, 1 – 20060 Gessate (MI) Italy Made in China How to use the watch for nurses We thank you for choosing our silicone watch for nurses and we hope that its use will give you full satisfaction. Before enabling the watch, please pay attention to any movement of one of the needles. This is due to the fact that the movement drive has not yet been activated. Once the battery protection tab is removed, the needle will move in only one direction. To enable the clock, pull it out of its silicone body and remove the protect tab on the charging mechanism. Pull the charging mechanism, rotate it to set the time and bring the mechanism into its housing to lock it. Replace the body of the watch on the opposite side of the securing pin. Cleaning Remove the watch from its silicone holder and clean the silicone with a cloth dampened with water and soap or alcohol at 70°. For the body of the watch, use a damp cloth as the watch is watertight. WEIGHT: 30 grams. BATTERY: SR626SW button battery (when the battery is low, throw it into the collection container; please refer to the procedure for the collection of batteries). BATTERY LIFE: 18 months. BATTERY REPLACEMENT: on the back of the watch, there is a notch to open the housing and get to the battery. Lift the rear with a sharp and thin instrument. Remove the white plastic cover and the battery by sliding it on the side. Insert the new battery complying with the correct polarity with the “+” facing up. Replace the white cover and close the case. GIMA WARRANTY CONDITIONS Congratulations for purchasing a GIMA product. This product meets high qualitative standards both as regards the material and the production. The warranty is valid for 12 months from the date of supply of GIMA. During the period of validity of the warranty, GIMA will repair and/or replace free of charge all the defected parts due to production reasons. Labor costs and personnel traveling expenses and packaging not included. All components subject to wear are not included in the warranty. The repair or replacement performed during the warranty period shall not extend the warranty. The warranty is void in the following cases: repairs performed by unauthorized personnel or with non-original spare parts, defects caused by negligence or incorrect use. GIMA cannot be held responsible for malfunctioning on electronic devices or software due to outside agents such as: voltage changes, electro-magnetic fields, radio interferences, etc. The warranty is void if the above regulations are not observed and if the serial code (if available) has been removed, cancelled or changed. The defected products must be returned only to the dealer the product was purchased from. Products sent to GIMA will be rejected. Index of symbols Caution: read instructions (warnings) carefully Product complies with European Directive Product code Follow instructions for use Keep in a cool, dry place Keep away from sunlight Lot number WEEE disposal [...]<p><a class="btn btn-secondary understrap-read-more-link" href="https://usemanuals.com/gima/watch-for-nurses/">Read More...</a></p>]]></description>
										<content:encoded><![CDATA[<h4>Watch for Nurses</h4>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/gima-logo-png-300x72-1.webp" /></p>
<p>PROFESSIONAL MEDICAL PRODUCTS</p>
<p>Gima S.p.A. Via Marconi, 1 – 20060 Gessate (MI) Italy gima@gimaitaly.com – export@gimaitaly.com<br />
www.gimaitaly.com</p>
<h5>WATCH FOR NURSES</h5>
<h5>ATTENTION:</h5>
<p>The operators must carefully read and completely understand the present manual before using the product. AVIS:<br />
20400 – 20401 – 20402 – 20403 – 20404 – 20405 – 20420 20421 – 20422 – 20423 – 20424 – 20425 – 20410 – 20411 20455 – 20460 – 20461 – 20462 – 20463 – 20464 – 20465<br />
Imported by: Gima S.p.A. Via Marconi, 1 – 20060 Gessate (MI) Italy Made in China</p>
<h5>How to use the watch for nurses</h5>
<p>We thank you for choosing our silicone watch for nurses and we hope that its use will give you full satisfaction. Before enabling the watch, please pay attention to any movement of one of the needles. This is due to the fact that the movement drive has not yet been activated. Once the battery protection tab is removed, the needle will move in only one direction.</p>
<p>To enable the clock, pull it out of its silicone body and remove the protect tab on the charging mechanism. Pull the charging mechanism, rotate it to set the time and bring the mechanism into its housing to lock it. Replace the body of the watch on the opposite side of the securing pin.</p>
<h5>Cleaning</h5>
<p>Remove the watch from its silicone holder and clean the silicone with a cloth dampened with water and soap or alcohol at 70°. For the body of the watch, use a damp cloth as the watch is watertight. WEIGHT: 30 grams. <strong>BATTERY:</strong> SR626SW button battery (when the battery is low, throw it into the collection container; please refer to the procedure for the collection of batteries).<br />
<strong>BATTERY LIFE:</strong> 18 months.<br />
<strong>BATTERY REPLACEMENT:</strong> on the back of the watch, there is a notch to open the housing and get to the battery. Lift the rear with a sharp and thin instrument. Remove the white plastic cover and the battery by sliding it on the side. Insert the new battery complying with the correct polarity with the “+” facing up. Replace the white cover and close the case.</p>
<h5>GIMA WARRANTY CONDITIONS</h5>
<p>Congratulations for purchasing a GIMA product. This product meets high qualitative standards both as regards the material and the production. The warranty is valid for 12 months from the date of supply of GIMA. During the period of validity of the warranty, GIMA will repair and/or replace free of charge all the defected parts due to production reasons. Labor costs and personnel traveling expenses and packaging not included. All components subject to wear are not included in the warranty. The repair or replacement performed during the warranty period shall not extend the warranty. The warranty is void in the following cases: repairs performed by unauthorized personnel or with non-original spare parts, defects caused by negligence or incorrect use. GIMA cannot be held responsible for malfunctioning on electronic devices or software due to outside agents such as: voltage changes, electro-magnetic fields, radio interferences, etc. The warranty is void if the above regulations are not observed and if the serial code (if available) has been removed, cancelled or changed. The defected products must be returned only to the dealer the product was purchased from. Products sent to GIMA will be rejected.</p>
<h5>Index of symbols</h5>
<p><img decoding="async" class="alignnone size-full wp-image-337938 ezlazyloaded" src="images/5.webp" alt="caution icon" width="79" height="74" data-ezsrc="https://manuals.plus/wp-content/uploads/2021/07/caution-icon-png.png?ezimgfmt=rs:79x74/rscb1/ng:webp/ngcb1" /> Caution: read instructions (warnings) carefully<br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/product-complies-png.webp" /> Product complies with European Directive<br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/product-code-png.webp" /> Product code<br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/instruction-png.webp" /> Follow instructions for use<br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/dry-place-icon-png.webp" />Keep in a cool, dry place<br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/keep-away-icon-png.webp" /> Keep away from sunlight<br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/lot-number-png.webp" /> Lot number<br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/disposal-icon-png.webp" /> WEEE disposal</p>
<form id="commentform" class="comment-form" action="https://manuals.plus/wp-comments-post.php" method="post" novalidate="">
<p class="form-submit">
</form>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>GIMA Walking Frame With 2 Wheels Manual</title>
		<link>https://usemanuals.com/gima/walking-frame/</link>
		
		<dc:creator><![CDATA[ItsManual]]></dc:creator>
		<pubDate>Wed, 23 Aug 2023 05:14:47 +0000</pubDate>
				<category><![CDATA[GIMA]]></category>
		<guid isPermaLink="false">https://usemanuals.com/?p=206200</guid>

					<description><![CDATA[GIMA Walking Frame With 2 Wheels User Manual All serious accidents concerning the medical device supplied by us must be reported to the manufacturer and competent authority of the member state where your registered office is located. INTRODUCTION This manual provides the instructons for a correct use of our patient aid or an assistant / carer. INTENDED USE The walking frame is designed to be used inside buildings by patients with an impairment to legs. The devices are intended to provide a support to the body. This aid allow patient mobility making it easy to walk. They must be used withtwo arms in order to guarantee safe operation. WARNING! The walking frame is built for indoor use and only on flatsurfaces. If it is necessary to employ the devices outside we advise to follow the road rules like any pedestrian. MAINTENANCE The walking frame do not require special care for their ordinary maintenance. We advise to regularly perform the following checks:  – verify the reliability of different components- check the correct fixing of screws and nuts- test moving parts, apply lubricant if needed – clean parts with mild detergents (do not use corrosive or harmful chemicals), put it in dry and ventilated environment. WARNING! Do not use the equipment in case it is damaged or any component is missing. Do not use the patient aids for purposes not mentioned in this user manual. Do not cross obstacles or use the patient aids on uneven surfaces, or wet and slippery. The use of the device is not recommended for people with poor functionality in the hands and arms. Max load 100kg fig. 1 Step 1: take out walker from package, open frame as pic 1, the frame is fixed when you heard a locking noise fig 2 Step 2: to close the frame, press the button as 1 shows on pic 2, then fold left and right frame as 2 &#38; 3 show. N° Part name QTY 1 Wheel 2 2 Leg tube 2 3 Connected frame 2 4 Cross bar 1 5 Stretch frame 1 6 Adjustable leg tube 2 Manufacturer Keep in a cool, dry place Consult instructions for use Keep away from sunlight Product code Medical Device compliant with Regulation (EU) 2017/745 Lot number Caution: read instructions (warnings) carefully Medical Device [...]<p><a class="btn btn-secondary understrap-read-more-link" href="https://usemanuals.com/gima/walking-frame/">Read More...</a></p>]]></description>
										<content:encoded><![CDATA[<p><strong>GIMA Walking Frame With 2 Wheels User Manual<br />
</strong></p>
<p><strong><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/00-57-300x225-1.webp" /></strong></p>
<p>All serious accidents concerning the medical device supplied by us must be reported to the manufacturer and competent authority of the member state where your registered office is located.</p>
<p><strong>INTRODUCTION<br />
</strong>This manual provides the instructons for a correct use of our patient aid or an assistant / carer.<br />
<strong>INTENDED USE</strong><br />
The walking frame is designed to be used inside buildings by patients with an impairment to legs. The devices are intended to provide a support to the body. This aid allow patient mobility making it easy to walk. They must be used withtwo arms in order to guarantee safe operation.<br />
<strong>WARNING</strong>! The walking frame is built for indoor use and only on flatsurfaces. If it is necessary to employ the devices outside we advise to follow the road rules like any pedestrian.<br />
<strong>MAINTENANCE</strong> The walking frame do not require special care for their ordinary maintenance. We advise to regularly perform the following checks:  – verify the reliability of different components- check the correct fixing of screws and nuts- test moving parts, apply lubricant if needed – clean parts with mild detergents (do not use corrosive or harmful chemicals), put it in dry and ventilated environment.<br />
<strong>WARNING</strong>! Do not use the equipment in case it is damaged or any component is missing. Do not use the patient aids for purposes not mentioned in this user manual. Do not cross obstacles or use the patient aids on uneven surfaces, or wet and slippery. The use of the device is not recommended for people with poor functionality in the hands and arms.</p>
<p><strong>Max load 100kg</strong></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/01-9-148x300-1.webp" /></p>
<p><em><strong>fig. 1</strong></em><br />
<strong>Step 1</strong>: take out walker from package, open frame as pic 1, the frame is fixed when you heard a locking noise</p>
<p><img fetchpriority="high" decoding="async" class="alignnone wp-image-329502 ezlazyloaded" src="images/6.webp" sizes="" srcset="" alt="Maintenance" width="502" height="427" data-ezsrcset="https://manuals.plus/wp-content/uploads/2021/07/03-8-300x254.jpg?ezimgfmt=ng:webp/ngcb1 300w,https://manuals.plus/wp-content/uploads/2021/07/03-8.jpg?ezimgfmt=ng:webp/ngcb1 599w" data-ezsrc="https://manuals.plus/wp-content/uploads/2021/07/03-8-300x254.jpg?ezimgfmt=rs:502x425/rscb1/ng:webp/ngcb1" /></p>
<p><em><strong>fig 2</strong></em><br />
<strong>Step 2</strong>: to close the frame, press the button as 1 shows on pic 2, then<br />
fold left and right frame as 2 &amp; 3 show.</p>
<table width="777">
<tbody>
<tr>
<td width="29"><strong>N°</strong></td>
<td width="103"><strong>Part name</strong></td>
<td width="36"><strong>QTY</strong></td>
</tr>
<tr>
<td width="29">1</td>
<td width="103">Wheel</td>
<td width="36">2</td>
</tr>
<tr>
<td width="29">2</td>
<td width="103">Leg tube</td>
<td width="36">2</td>
</tr>
<tr>
<td width="29">3</td>
<td width="103">Connected frame</td>
<td width="36">2</td>
</tr>
<tr>
<td width="29">4</td>
<td width="103">Cross bar</td>
<td width="36">1</td>
</tr>
<tr>
<td width="29">5</td>
<td width="103">Stretch frame</td>
<td width="36">1</td>
</tr>
<tr>
<td width="29">6</td>
<td width="103">Adjustable leg tube</td>
<td width="36">2</td>
</tr>
</tbody>
</table>
<table width="1001">
<tbody>
<tr>
<td width="39"><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/04-7.webp" /></td>
<td width="108">Manufacturer</td>
<td width="43"><img decoding="async" class="wp-image-329520 alignright ezlazyloaded" src="images/9.webp" alt="Keep in a cool, dry place" width="75" height="90" data-ezsrc="https://manuals.plus/wp-content/uploads/2021/07/09-1.jpg?ezimgfmt=rs:75x90/rscb1/ng:webp/ngcb1" /></td>
<td width="140">Keep in a cool, dry place</td>
</tr>
<tr>
<td width="39"><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/05-5.webp" /></td>
<td width="108">Consult instructions for use</td>
<td width="43"><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/10-174.webp" /></td>
<td width="140">Keep away from sunlight</td>
</tr>
<tr>
<td width="39"><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/06-4.webp" /></td>
<td width="108">Product code</td>
<td width="43"><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/11-165.webp" /></td>
<td width="140">Medical Device compliant with Regulation (EU) 2017/745</td>
</tr>
<tr>
<td width="39"><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/07-4.webp" /></td>
<td width="108">Lot number</td>
<td width="43"><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/13-143.webp" /></td>
<td width="140">Caution: read instructions (warnings) carefully</td>
</tr>
<tr>
<td width="39"><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/08-4.webp" /></td>
<td width="108">Medical Device</td>
<td width="43"></td>
<td width="140"></td>
</tr>
</tbody>
</table>
<form id="commentform" class="comment-form" action="https://manuals.plus/wp-comments-post.php" method="post" novalidate="">
<p class="form-submit">
</form>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>GIMA Classic Examination Couchs Manual</title>
		<link>https://usemanuals.com/gima/examination-couchs/</link>
		
		<dc:creator><![CDATA[ItsManual]]></dc:creator>
		<pubDate>Tue, 29 Aug 2023 16:18:22 +0000</pubDate>
				<category><![CDATA[GIMA]]></category>
		<guid isPermaLink="false">https://usemanuals.com/?p=208874</guid>

					<description><![CDATA[GIMA Classic Examination Couchs Instructions LETTINI DA VISITA MODELLO CLASSICO CLASSIC EXAMINATION COUCHS LITS ACCOMPAGNANTS CLASSIQUES CAMILLAS CONSULTA CLÁSICA MARQUESAS DE CONSULTA CLÁSSICAS UNTERSUCHUNGSBETT KLASSISCHES ΕΞΕΤΑΣΤΙΚΑ ΚΡΕΒΑΤΙΑ κλασικα PRODUCTS –27404 CLASSIC EXAMINATION COUCH – chromed – beige –27405 CLASSIC EXAMINATION COUCH – chromed – blue- backrest with hole –27445 CLASSIC EXAMINATION COUCH – chromed – apricot INTRODUCTION (EU) 2017/745, this product is part of the CLASS I MEDICAL DEVICES. You should carefully read this manual before using this medical device. DESCRIPTION The classic examination couch is designed for hospitals, community centers, nursing homes and medical offices. This couch has structures and legs entirely in polished chromed steel. The two sections of the matress are flame resistant and washable. The backrest is completely inclinable. COMPONENTS: –Mattress covered with washable and fire-retardant fabric already fixed to the chromed structure with backrest –Backrest’s rod –Chromed legs –On request: chromed couch roll holder Assembly material: –N. 4 TBE 8×16 (screwed to the structure) –ALLEN KEY ASSEMBLY INSTRUCTIONS: The couch is supplied partially assembled: the mattress is already fixed to the structure. Begin the assembly phase by setting up a stable horizontal work plan. Take the couch and place it down on a worktop on the side of the mattress (mattress already attached to the frame – DO NOT UNSCREW). Find the allen key to screw/rescrew the legs. Unscrew the tube of the backrest by hexagon screw and its nut. After loosening the TBE 8×16 screws, insert the legs with the crosspiece for the backrest into the frame and tighten the screws always using the supplied Allen key. Proceed in the same way with the opposite legs of the bed. Insert the adjustment rod into its housing (the plate hole). Re-tighten by screw and its nut. In detail the backrest at the end of assembly. 4 TECHNICAL DATA   Measurement   cm.188 x 57,5 x h 73,5 box 198 x 17 x 64 h   Weight   28 kg   Max capacity   120 kg WARNINGS! –Check the locking nuts are tightened. –Observe the maximum flow rates indicated in the data sheets. –Avoid direct contact with open wounds. –Not for use in open environments. –When adjusting the height of the couch and the back, make sure that no one inserts hands, legs or anything into the movement area: CRUSHING RISK! –Move the bed without lifting it from the floor. –Before moving the bed, unlock the wheels. MAINTENANCE AND CLEANING –Use only original spare parts. –Periodically check all fixing points. –To preserve at best, it is recommended to avoid prolonged exposure to sunlight, to contact and deposit in saline and very humid environments. –Wash the stainless steel surfaces with soapy water and use appropriate disinfectants. –Rinse with a damp cloth and dry thoroughly. –Do not spill on the surface cleaners containing chlorine or ammonia, fatty and oily substances. –Do not use cleaning utensils containing iron. If necessary disinfection only use suitable non-corrosive products. CLEANING RULES FOR COATING: Clean with damp soapy cloth and rinse well with clean water. Do not use solvents, bleaches, synthetic detergents, polishes or aerosol spray. Attention: Normally synthetic leather light colours should not come in contact with no fixed cloured clothes (such as jeans and similar) not to cause stains and rings that cannot be cleaned up. Keep away from sunlight Medical Device compliant with Regulation (EU) 2017/745 Keep in a cool, dry place Product code Consult instructions for use Manufacturer Caution: read instructions (warnings) carefully Lot number Medical Device GIMA WARRANTY TERMS The Gima 12-month standard B2B warranty applies. [...]<p><a class="btn btn-secondary understrap-read-more-link" href="https://usemanuals.com/gima/examination-couchs/">Read More...</a></p>]]></description>
										<content:encoded><![CDATA[<h4>GIMA Classic Examination Couchs Instructions</h4>
<p>LETTINI DA VISITA MODELLO CLASSICO CLASSIC EXAMINATION COUCHS LITS ACCOMPAGNANTS CLASSIQUES CAMILLAS CONSULTA CLÁSICA<br />
MARQUESAS DE CONSULTA CLÁSSICAS UNTERSUCHUNGSBETT KLASSISCHES ΕΞΕΤΑΣΤΙΚΑ ΚΡΕΒΑΤΙΑ κλασικα</p>
<h4>PRODUCTS</h4>
<p>–27404 CLASSIC EXAMINATION COUCH – chromed – beige<br />
–27405 CLASSIC EXAMINATION COUCH – chromed – blue- backrest with hole<br />
–27445 CLASSIC EXAMINATION COUCH – chromed – apricot</p>
<h4>INTRODUCTION</h4>
<p>(EU) 2017/745, this product is part of the CLASS I MEDICAL DEVICES. You should carefully read this manual before using this medical device.</p>
<h4>DESCRIPTION</h4>
<p>The classic examination couch is designed for hospitals, community centers, nursing homes and medical offices. This couch has structures and legs entirely in polished chromed steel. The two sections of the matress are flame resistant and washable. The backrest is completely inclinable.</p>
<h4>COMPONENTS:</h4>
<p>–Mattress covered with washable and fire-retardant fabric already fixed to the chromed structure with backrest<br />
–Backrest’s rod<br />
–Chromed legs<br />
–On request: chromed couch roll holder</p>
<h4>Assembly material:</h4>
<p>–N. 4 TBE 8×16 (screwed to the structure)<br />
–ALLEN KEY</p>
<h4>ASSEMBLY INSTRUCTIONS:</h4>
<p>The couch is supplied partially assembled: the mattress is already fixed to the structure. Begin the assembly phase by setting up a stable horizontal work plan.<br />
Take the couch and place it down on a worktop on the side of the mattress (mattress already attached to the frame – DO NOT UNSCREW). Find the allen key to screw/rescrew the legs.<br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/GIMA-Classic-Examination-Couchs-Instructions_1-300x154-1.webp" /></p>
<p>Unscrew the tube of the backrest by hexagon screw and its nut.<br />
<img loading="lazy" decoding="async" class="alignnone wp-image-318658 ezlazyloaded" src="images/6.webp" alt="" width="518" height="347" data-ezsrc="https://manuals.plus/wp-content/uploads/2021/07/GIMA-Classic-Examination-Couchs-Instructions_2-300x200.png?ezimgfmt=rs:518x345/rscb1/ng:webp/ngcb1" /></p>
<p>After loosening the TBE 8×16 screws, insert the legs with the crosspiece for the backrest into the frame and tighten the screws always using the supplied Allen key.<br />
Proceed in the same way with the opposite legs of the bed.<br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/GIMA-Classic-Examination-Couchs-Instructions_3-300x204-1.webp" /></p>
<p>Insert the adjustment rod into its housing (the plate hole). Re-tighten by screw and its nut.<br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/GIMA-Classic-Examination-Couchs-Instructions_4-300x151-1.webp" /></p>
<p>In detail the backrest at the end of assembly.<br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/GIMA-Classic-Examination-Couchs-Instructions_5-300x278-1.webp" />4</p>
<p>TECHNICAL DATA</p>
<table width="1165">
<tbody>
<tr>
<td width="448"><strong>  Measurement</strong></td>
<td width="448">  cm.188 x 57,5 x h 73,5 box 198 x 17 x 64 h</td>
</tr>
<tr>
<td width="448"><strong>  Weight</strong></td>
<td width="448">  28 kg</td>
</tr>
<tr>
<td width="448"><strong>  Max capacity</strong></td>
<td width="448">  120 kg</td>
</tr>
</tbody>
</table>
<h4>WARNINGS!</h4>
<p>–Check the locking nuts are tightened.<br />
–Observe the maximum flow rates indicated in the data sheets.<br />
–Avoid direct contact with open wounds.<br />
–Not for use in open environments.<br />
–When adjusting the height of the couch and the back, make sure that no one inserts hands, legs or anything into the movement area: CRUSHING RISK!<br />
–Move the bed without lifting it from the floor.<br />
–Before moving the bed, unlock the wheels.</p>
<h4>MAINTENANCE AND CLEANING</h4>
<p>–Use only original spare parts.<br />
–Periodically check all fixing points.<br />
–To preserve at best, it is recommended to avoid prolonged exposure to sunlight, to contact and deposit in saline and very humid environments.<br />
–Wash the stainless steel surfaces with soapy water and use appropriate disinfectants.<br />
–Rinse with a damp cloth and dry thoroughly.<br />
–Do not spill on the surface cleaners containing chlorine or ammonia, fatty and oily substances.<br />
–Do not use cleaning utensils containing iron. If necessary disinfection only use suitable non-corrosive products.</p>
<h4>CLEANING RULES FOR COATING:</h4>
<p>Clean with damp soapy cloth and rinse well with clean water. Do not use solvents, bleaches, synthetic detergents, polishes or aerosol spray. Attention: Normally synthetic leather light colours should not come in contact with no fixed cloured clothes (such as jeans and similar) not to cause stains and rings that cannot be cleaned up.</p>
<table width="1337">
<tbody>
<tr>
<td width="70"><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/GIMA-Classic-Examination-Couchs-Instructions_6.webp" /></td>
<td width="224"><em>Keep</em> <em>away</em> <em>from</em> <em>sunlight</em></td>
<td width="70"><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/GIMA-Classic-Examination-Couchs-Instructions_9.webp" /></td>
<td width="232"><em>Medical Device compliant</em></p>
<p><em>with Regulation (EU) 2017/745</em></td>
<td width="70"><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/GIMA-Classic-Examination-Couchs-Instructions_12.webp" /></td>
<td width="232"><em>Keep</em> <em>in</em> <em>a</em> <em>cool,</em> <em>dry</em> <em>place</em></td>
</tr>
<tr>
<td width="70"><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/GIMA-Classic-Examination-Couchs-Instructions_7.webp" /></td>
<td width="224"><em>Product</em> <em>code</em></td>
<td width="70"><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/GIMA-Classic-Examination-Couchs-Instructions_10.webp" /></td>
<td width="232"><em>Consult</em> <em>instructions</em> <em>for</em> <em>use</em></td>
<td width="70"><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/GIMA-Classic-Examination-Couchs-Instructions_13.webp" /></td>
<td width="232"><em>Manufacturer</em></td>
</tr>
<tr>
<td width="70"><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/GIMA-Classic-Examination-Couchs-Instructions_8.webp" /></td>
<td width="224"><em>Caution: read </em><em>instructions</em> <em>(warnings)</em> <em>carefully</em></td>
<td width="70"><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/GIMA-Classic-Examination-Couchs-Instructions_11.webp" /></td>
<td width="232"><em>Lot</em> <em>number</em></td>
<td width="70"><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/GIMA-Classic-Examination-Couchs-Instructions_14.webp" /></td>
<td width="232"><em>Medical</em> <em>Device</em></td>
</tr>
</tbody>
</table>
<h4>GIMA WARRANTY TERMS</h4>
<p>The Gima 12-month standard B2B warranty applies.</p>
<h4></h4>
<form id="commentform" class="comment-form" action="https://manuals.plus/wp-comments-post.php" method="post" novalidate="">
<p class="form-submit">
</form>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>GIMA Lampada Frontale Medica LED 38 KL 3W Manual</title>
		<link>https://usemanuals.com/gima/38-kl-3w-led/</link>
		
		<dc:creator><![CDATA[ItsManual]]></dc:creator>
		<pubDate>Fri, 08 Sep 2023 16:19:14 +0000</pubDate>
				<category><![CDATA[GIMA]]></category>
		<guid isPermaLink="false">https://usemanuals.com/?p=215736</guid>

					<description><![CDATA[GIMA Lambada Frontal Medical LED User Manual Gima S.p.A. Via Marconi, 1 – 20060 Gessate (MI) Italy gima@gimaitaly.com – export@gimaitaly.com www.gimaitaly.com GIMA 38 KL LED MEDICAL HEADLIGHT 3W GIMA 40 KL SURGICAL LED HEADLIGHT 5W User manual ATTENTION: The operators must carefully read and completely understand the present manual before using the product. 1. Introduction The light provides the user with a beam which is very uniform and exhibits no color change over the range of the depth of field of loupes. Built into the battery unit the headlight has steeples light intensity control adjustment. This allows the user to have precise control over the brightness of the headlight allowing for the maximum detail to be viewed. 2. Models 30879 GIMA 38 KL LED MEDICAL HEADLIGHT 3W Straight shape optical path Simple optical lens No inner light grating 30936 GIMA 40 KL SURGICAL LED HEADLIGHT 5W L shape optical path Multi optical lens Inner light grating 3. Technical data 4. Illustration 30879 The GIMA 38 KL Led Medical Headlight 3W is the model with single optical lens. The LED light housing is made by aluminum, so it is durable and light weight. Built into the battery unit the GIMA 38 KL Led Medical Headlight 3W has steeples light intensity control adjustment. This allows the user to have precise control over the brightness of the headlight allowing for the maximum detail to be viewed. GIMA 38 KL LED MEDICAL HEADLIGHT 3W Hygienic and comfortable leather cushions Adjust the width of headband Rechargeable battery LED screen display battery volume Switch on/off Brightness control 30936 The GIMA 40 KL Surgical Led Headlight 5W adopts L shape of optical path which has good axiality between the light beam and sight. Mini and low weight only 200 g. Spot size adjustable by inner mini light grating. Integrated cordless design with DC power supply and exchangeable rapidly. Precise light imaging by multi optical lens, uniform and distinct with no light pollution. Cordless LED headlight with single battery. GIMA 40 KL SURGICAL LED HEADLIGHT 5W Adjust the height of headband Adjust the width of headband Rechargeable battery LED screen display battery volume Switch on/off Brightness control Adjustment of light spot Adjusting height of the light head Hygienic and comfortable leather cushions 5. Packing list Packing list of headlight: LED headlight: 1 each Adaptor: 1 each Battery: 1 each or 2 (if configurated) EPE carton Packing case: 1 each Aluminum case: (option) 6. Adjustment According to individual condition, adjust the height and girth of the headband. 7. Cautions Attention for the LED light, avoid aiming at eyes directly. Keep the device dry, do not use at any wet place. Do not attach the optic glass with anything hard or hand. Do not wipe the glass with something hard or dirty. 8. Maintain First time use or long time not use, please charge for more than 6 hours. Please use the original adapter to avoid any damage of parts. Please use wet and clean soft cloth to clean this device, then use dry cloth to take off the water. Do not bath or keep at high temperature or high pressure this device. Waste battery: please treat according to the relevant provisions, please do not dispose of along with other domestic waste. Put the device into the box after you finish use. When the glass is dirty, please clean with soft cloth or hairbrush. 9. After-sale Guarantee time: 12 months after purchase. Guarantee time for battery: 3 months after purchase. During the guarantee period, in the case use and maintain the product correctly, if there is any breakdown which is caused by the product’s own quality, we will offer free fix and replace. Free maintain will not be given under the following circumstance: The breakdown caused by installation error and wrong operation. The damage caused by the dismantle movement of a non-our company authorized main- trainer. The damage caused by customer inappropriate preservation and maintain. The breakdown and the damage caused by the force majeure. 10. Working condition Environment temperature: 5°C~40°C Relative humidity: 80% Atmospheric pressure: 50 kPa~106 kPa Disposal: The product must not be disposed of along with other domestic waste. The users must dispose of this equipment by bringing it to a specific recycling point for electric and electronic equipment. For further information on recycling points contact the local authorities, the local recycling center or the shop where the product was purchased. If the equipment is not disposed of correctly, fines or penalties may be applied in accordance with the national legislation and regulations. GIMA WARRANTY CONDITIONS Congratulations for purchasing a GIMA product. This product meets high qualitative standards both as regards the material and the production. The warranty is valid for 12 months from the date of supply of GIMA. During the period of validity of the warranty, GIMA will repair and/or replace free of charge all the defected parts due to production reasons. Labor costs and personnel traveling expenses and packaging not included. All components subject to wear are not included in the warranty. The repair or replacement performed during the warranty period shall not extend the warranty. The warranty is void in the following cases: repairs performed by unauthorized personnel or with non-original spare parts, defects caused by negligence or incorrect use. GIMA cannot be held responsible for malfunctioning on electronic devices or software due to outside agents such as: voltage changes, electro-magnetic fields, radio interferences, etc. The warranty is void if the above regulations are not observed and if the serial code (if available) has been removed, cancelled or changed. The defected products must be returned only to the dealer the product was purchased from. Products sent to GIMA will be rejected. [...]<p><a class="btn btn-secondary understrap-read-more-link" href="https://usemanuals.com/gima/38-kl-3w-led/">Read More...</a></p>]]></description>
										<content:encoded><![CDATA[<pre><b>GIMA Lambada Frontal Medical LED User Manual</b></pre>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/09/GIMA-Lampada-Frontale-Medica-LED-User-Manual.webp" /></p>
<p><strong>Gima S.p.A.</strong><br />
Via Marconi, 1 – 20060 Gessate (MI) Italy<br />
<a href="mailto:gima@gimaitaly.com">gima@gimaitaly.com</a> – <a href="mailto:export@gimaitaly.com">export@gimaitaly.com</a><br />
<a href="https://www.gimaitaly.com/default.asp?lang=en" target="_blank" rel="noopener">www.gimaitaly.com</a></p>
<p><strong>GIMA 38 KL LED MEDICAL HEADLIGHT 3W<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/09/GIMA-Lampada-Frontale-Medica-LED-User-Manual-Product-Overview.webp" /></strong><br />
<strong>GIMA 40 KL SURGICAL LED HEADLIGHT 5W</strong><br />
<strong>User manual</strong></p>
<p><strong>ATTENTION:</strong> The operators must carefully read and completely understand the present manual before using the product.</p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/09/GIMA-Lampada-Frontale-Medica-LED-User-Manual-License.webp" /></p>
<h4>1. Introduction</h4>
<p>The light provides the user with a beam which is very uniform and exhibits no color change over the range of the depth of field of loupes. Built into the battery unit the headlight has steeples light intensity control adjustment. This allows the user to have precise control over<br />
the brightness of the headlight allowing for the maximum detail to be viewed.</p>
<h4>2. Models</h4>
<p><strong>30879</strong><br />
<strong>GIMA 38 KL LED MEDICAL HEADLIGHT 3W</strong><br />
Straight shape optical path Simple optical lens No inner light grating</p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/09/GIMA-Lampada-Frontale-Medica-LED-User-Manual-Models-30879.webp" /></p>
<p><strong>30936</strong><br />
<strong>GIMA 40 KL SURGICAL LED HEADLIGHT 5W</strong><br />
L shape optical path Multi optical lens Inner light grating</p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/09/GIMA-Lampada-Frontale-Medica-LED-User-Manual-Models-30936.webp" /></p>
<h4>3. Technical data</h4>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/09/GIMA-Lampada-Frontale-Medica-LED-User-Manual-Technical-data.webp" /></p>
<h4>4. Illustration</h4>
<p><strong>30879</strong><br />
The GIMA 38 KL Led Medical Headlight 3W is the model with single optical lens. The LED light housing is made by aluminum, so it is durable and light weight. Built into the battery unit the GIMA 38 KL Led Medical Headlight 3W has steeples light intensity control adjustment. This allows the user to have precise control over the brightness of the headlight allowing for the maximum detail to be viewed.</p>
<p><strong>GIMA 38 KL LED MEDICAL HEADLIGHT 3W<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/09/GIMA-Lampada-Frontale-Medica-LED-User-Manual-GIMA-38-KL-LED-MEDICAL-HEADLIGHT-3W.webp" /></strong></p>
<ol>
<li>Hygienic and comfortable leather cushions</li>
<li>Adjust the width of headband</li>
<li>Rechargeable battery</li>
<li>LED screen display battery volume</li>
<li>Switch on/off</li>
<li>Brightness control</li>
</ol>
<p><strong>30936</strong><br />
The GIMA 40 KL Surgical Led Headlight 5W adopts L shape of optical path which has good axiality between the light beam and sight. Mini and low weight only 200 g. Spot size adjustable by inner mini light grating. Integrated cordless design with DC power supply and exchangeable rapidly. Precise light imaging by multi optical lens, uniform and distinct with no light pollution. Cordless LED headlight with single battery.</p>
<p><strong>GIMA 40 KL SURGICAL LED HEADLIGHT 5W<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/09/GIMA-Lampada-Frontale-Medica-LED-User-Manual-GIMA-40-KL-SURGICAL-LED-HEADLIGHT-5W.webp" /></strong></p>
<ol>
<li>Adjust the height of headband</li>
<li>Adjust the width of headband</li>
<li>Rechargeable battery</li>
<li>LED screen display battery volume</li>
<li>Switch on/off</li>
<li>Brightness control</li>
<li>Adjustment of light spot</li>
<li>Adjusting height of the light head</li>
<li>Hygienic and comfortable leather cushions</li>
</ol>
<h4>5. Packing list</h4>
<p>Packing list of headlight:</p>
<ol>
<li>LED headlight: 1 each</li>
<li>Adaptor: 1 each</li>
<li>Battery: 1 each or 2 (if configurated)</li>
<li>EPE carton Packing case: 1 each<br />
Aluminum case: (option)</li>
</ol>
<h4>6. Adjustment</h4>
<p>According to individual condition, adjust the height and girth of the headband.</p>
<h4>7. Cautions</h4>
<p>Attention for the LED light, avoid aiming at eyes directly. Keep the device dry, do not use at any wet place. Do not attach the optic glass with anything hard or hand. Do not wipe the glass with something hard or dirty.</p>
<h4>8. Maintain</h4>
<ol>
<li>First time use or long time not use, please charge for more than 6 hours.</li>
<li>Please use the original adapter to avoid any damage of parts.</li>
<li>Please use wet and clean soft cloth to clean this device, then use dry cloth to take off the water.</li>
<li>Do not bath or keep at high temperature or high pressure this device.</li>
<li>Waste battery: please treat according to the relevant provisions, please do not dispose of along with other domestic waste.</li>
<li>Put the device into the box after you finish use.</li>
<li>When the glass is dirty, please clean with soft cloth or hairbrush.</li>
</ol>
<h4>9. After-sale</h4>
<p>Guarantee time: 12 months after purchase. Guarantee time for battery: 3 months after purchase. During the guarantee period, in the case use and maintain the product correctly, if there is any breakdown which is caused by the product’s own quality, we will offer free fix and replace. Free maintain will not be given under the following circumstance:</p>
<ol>
<li>The breakdown caused by installation error and wrong operation.</li>
<li>The damage caused by the dismantle movement of a non-our company authorized main- trainer.</li>
<li>The damage caused by customer inappropriate preservation and maintain.</li>
<li>The breakdown and the damage caused by the force majeure.</li>
</ol>
<h4>10. Working condition</h4>
<ol>
<li>Environment temperature: 5°C~40°C</li>
<li>Relative humidity: 80%</li>
<li>Atmospheric pressure: 50 kPa~106 kPa</li>
</ol>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/09/GIMA-Lampada-Frontale-Medica-LED-User-Manual-Symbols.webp" /></p>
<p><strong><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/09/GIMA-Lampada-Frontale-Medica-LED-User-Manual-Disposal-icon.webp" />Disposal:</strong> The product must not be disposed of along with other domestic waste. The users must dispose of this equipment by bringing it to a specific recycling point for electric and electronic equipment. For further information on recycling points contact the local authorities, the local recycling center or the shop where the product was purchased. If the equipment is not disposed of correctly, fines or penalties may be applied in accordance with the national legislation and regulations.</p>
<p><strong>GIMA WARRANTY CONDITIONS</strong><br />
Congratulations for purchasing a GIMA product. This product meets high qualitative standards both as regards the material and the production. The warranty is valid for 12 months from the date of supply of GIMA. During the period of validity of the warranty, GIMA will repair and/or replace free of charge all the defected parts due to production reasons. Labor costs and personnel traveling expenses and packaging not included.<br />
All components subject to wear are not included in the warranty. The repair or replacement performed during the warranty period shall not extend the warranty. The warranty is void in the following cases: repairs performed by unauthorized personnel or with non-original spare parts, defects caused by negligence or incorrect use. GIMA cannot be held responsible for malfunctioning on electronic devices or software due to outside agents such as: voltage changes, electro-magnetic fields, radio interferences, etc. The warranty is void if the above regulations are not observed and if the serial code (if available) has been removed, cancelled or changed. The defected products must be returned only to the dealer the product was purchased from. Products sent to GIMA will be rejected.</p>
<form id="commentform" class="comment-form" action="https://manuals.plus/wp-comments-post.php" method="post" novalidate="">
<p class="form-submit">
</form>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>GIMA Swivel Shower Chair 27733 Manual</title>
		<link>https://usemanuals.com/gima/27733-shower-chair/</link>
		
		<dc:creator><![CDATA[ItsManual]]></dc:creator>
		<pubDate>Mon, 11 Sep 2023 09:07:41 +0000</pubDate>
				<category><![CDATA[GIMA]]></category>
		<guid isPermaLink="false">https://usemanuals.com/?p=218281</guid>

					<description><![CDATA[GIMA S.p.A. Via Marconi, 1 20060 Gessate (MI) – Italy www.gimaitaly.com EXPORT phone +39 02 953854209/221/225 fax +39 02 95380056 export@gimaitaly.com CODE 27733 SWIVEL SHOWER CHAIR USER’S MANUAL WARNING: Be sure to read all information and directions before use. ▲ DO NOT install this equipment without first reading and understanding this instruction sheet. ▲ ALWAYS verify that the device is secure prior to use. ▲ ALWAYS observe the weight limit on the labelling of your product. ▲ ENSURE to follow all instruction required while operating this device. ASSEMBLY/FITTING: 1. Put two legs cross to form right angle and screw on the knob in the center hole. 2. To screw assembly other knobs with the swivel seat. 3. Adjust the seat height. 4. Select one end for handle screwed on, and covers up the small lids on the other end. OPERATION: 1. Adjust the seat height, Sit on, Push down the front bottom to swivel the top seat. 2. Turn around right or left with one hand holding on the handle. 3. Hand off the front bottom. 4. Position lock at right angle location. Importato da/Imported by/Importé par/Importado por Gima S.p.A. Via Marconi, 1 – 20060 – Gessate (MI) – Italy Made in China Rev.2.02.20 [...]<p><a class="btn btn-secondary understrap-read-more-link" href="https://usemanuals.com/gima/27733-shower-chair/">Read More...</a></p>]]></description>
										<content:encoded><![CDATA[<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/09/GIMA-Swivel-Shower-Chair-logo.webp" /></p>
<p><strong>GIMA S.p.A.</strong><br />
Via Marconi, 1<br />
20060 Gessate (MI) – Italy<br />
<a href="http://www.gimaitaly.com/" target="_blank" rel="noopener">www.gimaitaly.com</a><br />
<strong>EXPORT</strong><br />
phone +39 02 953854209/221/225<br />
fax +39 02 95380056<br />
<a href="mailto:export@gimaitaly.com">export@gimaitaly.com</a></p>
<p><strong>CODE 27733 SWIVEL SHOWER CHAIR USER’S MANUAL</strong><br />
<strong><img loading="lazy" decoding="async" class="attachment-post-thumbnail ezlazyloaded" src="images/5.webp" alt="Warning-icon.png" width="53" height="48" data-ezsrc="https://manuals.plus/wp-content/uploads/2021/07/warning-cion-9.png?ezimgfmt=rs:53x48/rscb1/ng:webp/ngcb1" /> WARNING</strong>: Be sure to read all information and directions before use.<br />
▲ DO NOT install this equipment without first reading and understanding this instruction sheet.<br />
▲ ALWAYS verify that the device is secure prior to use.<br />
▲ ALWAYS observe the weight limit on the labelling of your product.<br />
▲ ENSURE to follow all instruction required while operating this device.</p>
<h4>ASSEMBLY/FITTING:</h4>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/09/GIMA-Swivel-Shower-Chair-assembly.webp" /></p>
<p>1. Put two legs cross to form right angle and screw on the knob in the center hole.<br />
2. To screw assembly other knobs with the swivel seat.<br />
3. Adjust the seat height.<br />
4. Select one end for handle screwed on, and covers up the small lids on the other end.</p>
<h4>OPERATION:</h4>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/09/GIMA-Swivel-Shower-Chair-OPERATION.webp" /></p>
<p>1. Adjust the seat height, Sit on, Push down the front bottom to swivel the top seat.<br />
2. Turn around right or left with one hand holding on the handle.</p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/09/GIMA-Swivel-Shower-Chair-OPERATION-2.webp" /></p>
<p>3. Hand off the front bottom.<br />
4. Position lock at right angle location.</p>
<p>Importato da/Imported by/Importé par/Importado por Gima S.p.A.<br />
Via Marconi, 1 – 20060 – Gessate (MI) – Italy<br />
Made in China</p>
<p>Rev.2.02.20</p>
<form id="commentform" class="comment-form" action="https://manuals.plus/wp-comments-post.php" method="post" novalidate="">
<p class="form-submit">
</form>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>

<!--
Performance optimized by W3 Total Cache. Learn more: https://www.boldgrid.com/w3-total-cache/

Page Caching using Disk: Enhanced 

Served from: usemanuals.com @ 2026-10-05 16:59:56 by W3 Total Cache
-->