<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>FUJITSU &#8211; UseManuals</title>
	<atom:link href="http://usemanuals.com/fujitsu/feed/" rel="self" type="application/rss+xml" />
	<link>https://usemanuals.com</link>
	<description>Owner&#039;s manuals for all sorts of products</description>
	<lastBuildDate>Sat, 22 Jul 2023 09:39:13 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.7.2</generator>

<image>
	<url>https://usemanuals.com/wp-content/uploads/2025/02/favicon-32x32-2.png</url>
	<title>FUJITSU &#8211; UseManuals</title>
	<link>https://usemanuals.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>FUJITSU Thermostat Convertor Manual</title>
		<link>https://usemanuals.com/fujitsu/thermostat-convertor/</link>
		
		<dc:creator><![CDATA[ItsManual]]></dc:creator>
		<pubDate>Tue, 04 Apr 2023 09:29:24 +0000</pubDate>
				<category><![CDATA[FUJITSU]]></category>
		<guid isPermaLink="false">https://usemanuals.com/?p=56640</guid>

					<description><![CDATA[&#160; FUJITSU Thermostat Convertor SAFETY PRECAUTIONS The “SAFETY PRECAUTIONS” indicated in this manual contain important information pertaining to your safety. Be sure to observe them. Request the user to keep this manual on hand for future use, such as for relocating or repairing the unit. WARNING This mark indicates procedures which, if improperly performed, might lead to the death or serious injury of the user. Perform electrical work by an authorized service personnel in accordance with this manual and the electrical wiring regulations or implementation regulations of the country. Also do not install this product by yourself. Improper electric work will cause electric shock or a fire. Perform installation work in accordance with this manual. Request an authorized service personnel to perform installation work. Do not install this product by yourself. Improper installation will cause injury, electric shock, fire, etc. In the event of a malfunction (burning smell, etc.), immediately stop operation, turn off the electrical breaker, and consult authorized service personnel. Do not install the unit in the following areas: Do not install the unit near a source of heat, steam or flammable gas. Area fi lled with mineral oil or containing a large amount of splashed oil or steam, such as a kitchen. It will deteriorate plastic parts, causing the parts to fail or the unit to leak water. Area that generates substances that adversely affect the equipment, such as sulfuric gas, chlorine gas, acid or alkali. It will cause the copper pipes and brazed joints to corrode, which can cause refrigerant leakage. Area containing equipment that generates electromagnetic interference. It will cause the control system to malfunction, preventing the unit from operating normally. Area that can cause combustible gas to leak, contains suspended carbon fibers or flammable dust, or volatile inflammables such as paint thinner or gasoline. If gas leaks and settles around the unit, it can cause a fi re. Install the unit in a well-ventilated place avoiding rains and direct sunlight. Do not operate this product when your hands are wet. Touching the unit with wet hands will cause an electric shock. If children may approach the unit, take preventive measures so that they cannot reach the unit. CAUTION This mark indicates procedures which, if improperly performed, might possibly result in personal harm to the user or damage to property. Pay abundant care when transporting this product because it is a precision device. Improper transportation will cause trouble. Do not touch the switches with sharp objects. Doing so will cause injury, trouble, or electric shock. Do not expose this product directly to water. Doing so will cause trouble, electric shock, or heating. Do not set vessels containing a liquid on this product. Doing so will cause heating, fi re, or electric shock. Dispose of the packing materials safely. Tear and dispose of the plastic packing bags so that children cannot play with them. There is the danger of suffocation if children play with the original plastic bags. NOTES: This product is manufactured to metric units and tolerances. United States customary units are provided for reference only. In cases where exact dimensions and tolerances are required, always refer to metric units. MAIN UNIT AND ACCESSORIES The following installation parts are supplied. Use them as required. ELECTRICAL REQUIREMENT Use Size Cable type Remarks   Remote con- troller cable (2-wire type)   16~22AWG (0.33 to 1.25 mm2)   Sheathed PVC cable* Non-polar 2 core, twisted pair Maximum cable length: 1,640 ft (500m) Remote con- troller cable (3-wire type) 22AWG (0.33 mm2)   Sheathed PVC cable* Polar 3core Maximum cable length: 82 ft (25m) Thermostat wires 18AWG (0.82 mm2) Sheathed PVC cable* Maximum cable length: 164 ft (50m) Use shielded cable in accordance with local rules for remote controller cable. SELECTING AN INSTALLATION LOCATION Dimensions This product is comprised of a body and cover. Set the bottom side to a flat place. Specifications Power consumption (W) 0.6 Temperature °F (°C) Operating 32–114 (0–46) Packaged 14–140 (-10–60) Humidity (%) Packaged 0–95 (RH); No condensation Dimensions H x W x D  in (mm) 1-1/16 × 3-7/16 × 3-7/16 (27 × 86.7 × 86.7) Weight oz. (g) 4 (100) WIRING WARNING: Before starting installation work, turn off the power of this product and the connection destination. Do not turn on the power again until installation is completed. Otherwise, it will cause electric shock or fi re. Use the accessories or specified connection cable. Do not modify power supply cable and connection cables other than those specified, do not use extension cables, and do not use independent branch wiring. It may cause electric shock or fi re. Install the connection cables securely to the terminal block. Confirm that external force of the cable is not applied to the terminal block. Use the specified cables. If intermediate connection or insertion fi xing are imperfect, it will cause electric shock, fire, etc. When connecting the connection cable, route the cables so that the cover of this product is securely fixed. If the cover is imperfectly fixed, it may cause fi re or overheating of the terminals. Perform earth (ground) work positively. Do not connect the earth (ground) cable to a telephone cable, water pipe, or conductor rod. Perform all wiring works so that the user does not touch the wiring. Otherwise it will cause injury or electric shock. If any cable is damaged, do not repair or modify it yourself. Improper work will cause electric shock or fire. CAUTION: Do not bind the remote controller cable and the external input cable together with or parallel to the power supply cable of the indoor and outdoor units. It may cause erroneous operation. When performing wiring work, be careful not to damage the cable or injure yourself. Also, connect the connectors securely. Loose connectors will cause trouble, heating, fi re, or electric shock. Install the indoor unit, outdoor unit, power supply cable, transmission cable and remote control cable at least 40 in (1 m) away from a television or radio. The purpose of this is to prevent TV reception interference or radio noise. (Even if they are installed more than 40 in (1 m) apart, you could still receive noise under some signal conditions.) Perform wiring so that water does not enter this product along the external wiring. Always install a trap to the wiring or take other countermeasures. Otherwise it will cause trouble or electric shock or fire. Confirm the name of each unit and name of each terminal block of the unit and connect the wiring in accordance with the directions given in the manual so that there is no incorrect wiring. Incorrect wiring will damage the electric parts and cause smoke and fire. When installing the connection cables near a source of electromagnetic waves, use shielded cable. Otherwise, a breakdown or malfunction could result. The terminal screws and earth (ground) screws have different shapes. Be sure to install the screws in the correct locations. If the screws are installed in the wrong locations, the circuit board could be damaged. Wiring method The connection example of thermostat convertor and thermostat controller is shown below. The connection method is different depending on the type of thermostat controller. Connect them according to the following Cases. For remote controller cable, 2 kinds of type, which are 2-wire type and 3-wire type are available depending on the device to be connected. All wiring shown should be performed with 18 AWG thermostat wire. Terminals to thermostat controller on this product support 20-30VAC. High/medium/low fan signals are optional, and may not be available on all thermostat models. W2 and Y2 signals are optional, and may be omitted for single-stage thermostats. In addition, if Y2 and W2 are used, turn ON the DIP switches SET3-1. Case 1: Two-stage Cooling and Heating (Example: Remote controller for 3-wire type) Install the transformer, as necessary, per building code and manufacturer’s installation instructions. Maximum Power: 5.0VA Case 2: Single-stage Cooling and Heating (Example: Remote controller for 2-wire type) Case 3: Single-stage Cooling and Heating with Dedicated Fan Speed Relays (Example: Remote controller for 2-wire type) The names of terminal connected to thermostat have the following meanings. TC Common (In) from transformer C Common to thermostat controller TR Power supply from transformer R Power supply to thermostat controller G3 Airflow High G2 Airflow Medium G1 Airflow Low Y2 Cooling Stage 2 Y1 Cooling Stage 1 W2 Heating Stage 2 W1 Heating Stage 1 G Fan NOTES: Up to 16 indoor units may be controlled with a single thermostat controller, Multiple indoor units connected to convertor operate by the same operating setting. Two or more types of VRF1 system, VRF2 system, single model or multi systems cannot be mixed together. Unit wiring Thermostat cable and Remote controller cable Thermostat cable Remote controller cable WARNING: Tighten the terminal screws to the specified torques, otherwise, abnormal overheating may be occurred and possibly cause heavy damage inside the unit. Tightening torque M2 screw Remote controller / Y1, Y2, Y3 Thermostat input / G, W1, W2, Y1, Y2, G1, G2, G3, R, TR, C, TC 1.9 to 2.2 lbf·in (0.22 to 0.25 N·m) (2.2 to 2.5 kgf·cm) CAUTION: To peel the sheath from the cables, use a dedicated tool that will not damage the conductor of the cable. When installing a screw on the terminal block, do not cut the cable by overtightening the screw. On the other hand, a loosen screw can cause faulty contact, which will lead to a communication failure. INSTALLING THE THERMOSTAT CONVERTOR WARNING: Always use the accessories and specified installation work parts. Check the state of the installation parts. Not using the specified parts will cause units to fall off, electric shock, fi re, etc. Install at a place that can withstand the weight of the unit and install positively so that the unit will not topple or fall. When installing this product, make sure that there are no children nearby. Otherwise, injury or electric shock could result. CAUTION: Do not set the DIP switch of this product except as specified in this installation manual or the instruction manual supplied with the air conditioner. Setting the switches other than specified will cause an accident or trouble. Use an insulated screwdriver to set the DIP switches. Before opening the cover of this product, completely discharge static electricity charged on your body. Otherwise, failure or malfunction could result. Do not touch the circuit board and circuit board parts directly with your hands. Otherwise, injury or electric shock could result. Tightening the mounting screws too tight will damage the body of this product. When using the indoor unit without Fan mode, do not connect G (Fan), G1, G2, and G3 signals. Otherwise air conditioner might operate incorrectly. If the air conditioner system is a heat pump type, please select “ Priority on Administrative Indoor Unit” in the setting of priority mode by PUSH SWITCH of outdoor unit (refer to installation manual of outdoor unit). Furthermore, please complete “Administrative Indoor Unit Setting” for indoor unit which is connected to this Thermostat Convertor by using the wired remote controller (refer to installation manual of remote controller.) NOTES: When this product is used, do not use the remote controller because indoor unit is controlled centrally by thermostat controller. However, the remote controller connecting is temporarily required for the initial setting. During the initial setting by remote controller do not connect Thermostat Convertor to indoor unit. After when all initial setting is completed, disconnect the wired remote controller. Then connect Thermostat Converter to indoor unit at first time. Connecting the cables For thermostat cable, use the single wire of 18AWG thermostat wire. Power-supply voltage of thermostat (TC, TR) is 20 to 30VAC. Insert the cable to the connected terminal and fi x with screw using screw driver. For remote controller cable, 2 kinds of 2 kinds of type, which are 2-wire type and 3-wire type are available depending on the device to be connected. The number of connected thermostat cable is different the type of thermostat controller. For details of connection method, refer to Case 1 to Case 3 of “5. Wiring”. CONNECTION OF REMOTE CONTROLLER CABLE CAUTION: When connecting the remote controller cable to the indoor unit, do not connect it to the outdoor unit or the power terminal block. It may cause a failure. There are 2 methods to connect the remote controller cable to the indoor unit. One is the connection using connecting cable contained by indoor unit, and the other is the connection the remote controller cable is connected to the exclusive terminal block of the indoor unit. Exclusive terminal block for remote controller connection method is different depending on each model. Modify the remote controller cable as per below description and connect it. (For the details, refer to the installation manual of the indoor unit to be used.) When connecting to the connector Case 1: For non-polar 2-wire Use a tool to cut off the terminal on the end of the remote controller cable, and then remove the insulation from the cut end of the cable as shown in Fig. 1. Connect the remote controller cable and connecting cable as shown in Fig. 2. Be sure to insulate between the cables. Insert it to the connector. Set to “2WIRE” the DIP switch (SW1) on the PC board of the indoor unit. Case 2: For polar 3-wire Modify the cable as per below methods. Use a tool to cut off the terminal on the end of the remote controller cable, and then remove the insulation from the cut end of the cable as shown in Fig. 1. Connect the remote controller cable and connecting cable as shown in Fig. 2. Be sure to insulate between the cables. When the board has the 2WIRE/3WIRE DIP switch on it, set it to 3WIRE. For how to set, see “Case 1: For non-polar 2-wire”. When connecting to the exclusive terminal block Connect the end of remote controller cable directly to the exclusive terminal block. If there is the 2WIRE/3WIRE switch on the PC board of the indoor unit, set it to match the connection method of the connected remote controller cable. Example) Connection of non-polar 2-wire CIRCUIT BOARD SETTING Remove the cover of main unit by the following procedure to perform the initial setting. Tightening torque M3 screw                  4.4 to 5.3 lbf·in (0.5 to 0.6 N·m) (5 to 6 kgf·cm) When the cover is removed, the circuit board appears. The circuit board has DIP switches and LEDs as shown below. Perform the initial setting using 3 DIP switches (SET 1 to 3) on the circuit board. (1) 2WIRE/3WIRE setting (SET1) Remote controller 2WIRE/3WIRE switching SW “Factory setting : 2WIRE” Set matched with the connection method of the remote controller cable to be connected. (2) Single-stage or Two-stage setting SW SET3-1                             Contents OFF                          Temperature setting: Single-stage ON                            Temperature setting: Two-stage (3) Temperature setting Single-stage setting Cooling setting temperature SW SET3-2 Cooling Stage 1 setting temperature °F (°C) Remarks OFF« 64 (18) Pattern1 ON 68 (20) Pattern2 Heating setting temperature SW SET3-3 SW SET3-4 Heating Stage 1 setting temperature °F (°C) Remarks OFF« OFF« 86 (30) Pattern1 OFF ON 81 (27) Pattern2 ON OFF 75 (24) Pattern3 ON ON 70 (21) Pattern4 Two-stage setting Cooling setting temperature SW SET3-2 Cooling Stage 1 setting temperature °F (°C) Cooling Stage 2 setting temperature °F (°C) Remarks OFF« 68 (20) 64 (18) Pattern1 ON 72 (22) 68 (20) Pattern2 Heating setting temperature SW SET3-3 SW SET3-4 Heating Stage 1 setting temperature °F (°C) Heating Stage 2 setting temperature °F (°C) Remarks OFF« OFF« 81 (27) 86 (30) Pattern1 OFF ON 77 (25) 82 (28) Pattern2 ON OFF 75 (23) 79 (26) Pattern3 ON ON 70 (21) 75 (24) Pattern4 NOTES: These are the limit temperature for cooling and heating. Energy saving performance is improved in the order from Cooling Pat- tern 1 to 2 and Heating Pattern 1 to 4. Delay off setting SW SET2-3 SW SET2-4 Delay off time OFF« OFF« 0 minutes OFF ON 5 minutes ON OFF 10 minutes ON ON 20 minutes NOTES: These are the limit temperature for cooling and heating. Energy saving performance is improved in the order from Cooling Pattern 1 to 2 and Heating Pattern 1 to 4. Delay OFF: Delay OFF is the function to operate continuously after reaching to the setting temperature of thermostat. This function may make the air conditioning effi cient. Set the Delay OFF time by SW SET 2-3 and SW SET 2-4. Fan setting (G signal) SW SET2-1 SW SET2-2 Indoor unit airflow OFF« OFF« Auto OFF ON High ON OFF Med. ON ON Low TURNING ON THE POWER Check this product wiring and switch settings on the circuit board. Check the wiring and switch settings for the VRF system or multi system or single model. For the wiring and switch settings method, refer to the installation instruction sheet of each unit. Turn on the power for the VRF system etc. Power will be supplied from the indoor unit to this product. This product will be initialized and the power turned on. LED1 (green) and LED2 (orange) will fl ashing. After initial setting is completed, operation will be restarted automatically. LED1 (green) lights. This product does not operate during initialization. An error code will appear on LED in the event of a malfunction. LED DISPLAY Normal code Error code USAGE For the usage and installation of thermostat controller, refer to the operating manual and installation manual of thermostat controller. [...]<p><a class="btn btn-secondary understrap-read-more-link" href="https://usemanuals.com/fujitsu/thermostat-convertor/">Read More...</a></p>]]></description>
										<content:encoded><![CDATA[<p>&nbsp;</p>
<h3><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/03/logo-3.png" /></h3>
<h4>FUJITSU Thermostat Convertor</h4>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/03/product-167.webp" /></p>
<h4>SAFETY PRECAUTIONS</h4>
<ul>
<li>The “SAFETY PRECAUTIONS” indicated in this manual contain important information pertaining to your safety. Be sure to observe them.</li>
<li>Request the user to keep this manual on hand for future use, such as for relocating or repairing the unit.</li>
</ul>
<p><strong>WARNING</strong></p>
<p>This mark indicates procedures which, if improperly performed, might lead to the death or serious injury of the user.<br />
Perform electrical work by an authorized service personnel in accordance with this manual and the electrical wiring regulations or implementation regulations of the country. Also do not install this product by yourself.<br />
Improper electric work will cause electric shock or a fire.</p>
<p>Perform installation work in accordance with this manual. Request an authorized service personnel to perform installation work. Do not install this product by yourself. Improper installation will cause injury, electric shock, fire, etc.<br />
In the event of a malfunction (burning smell, etc.), immediately stop operation, turn off the electrical breaker, and consult authorized service personnel.<br />
Do not install the unit in the following areas:</p>
<ul>
<li>Do not install the unit near a source of heat, steam or flammable gas.</li>
<li>Area fi lled with mineral oil or containing a large amount of splashed oil or steam, such as a kitchen. It will deteriorate plastic parts, causing the parts to fail or the unit to leak water.</li>
<li>Area that generates substances that adversely affect the equipment, such as sulfuric gas, chlorine gas, acid or alkali. It will cause the copper pipes and brazed joints to corrode, which can cause refrigerant leakage.</li>
<li>Area containing equipment that generates electromagnetic interference. It will cause the control system to malfunction, preventing the unit from operating normally.</li>
<li>Area that can cause combustible gas to leak, contains suspended carbon fibers or flammable dust, or volatile inflammables such as paint thinner or gasoline. If gas leaks and settles around the unit, it can cause a fi re.</li>
<li>Install the unit in a well-ventilated place avoiding rains and direct sunlight.</li>
</ul>
<p>Do not operate this product when your hands are wet. Touching the unit with wet hands will cause an electric shock.<br />
If children may approach the unit, take preventive measures so that they cannot reach the unit.</p>
<p><strong>CAUTION</strong></p>
<p>This mark indicates procedures which, if improperly performed, might possibly result in personal harm to the user or damage to property.</p>
<ul>
<li>Pay abundant care when transporting this product because it is a precision device. Improper transportation will cause trouble.</li>
<li>Do not touch the switches with sharp objects. Doing so will cause injury, trouble, or electric shock.</li>
<li>Do not expose this product directly to water. Doing so will cause trouble, electric shock, or heating.</li>
<li>Do not set vessels containing a liquid on this product. Doing so will cause heating, fi re, or electric shock.</li>
<li>Dispose of the packing materials safely. Tear and dispose of the plastic packing bags so that children cannot play with them. There is the danger of suffocation if children play with the original plastic bags.</li>
</ul>
<p><strong>NOTES:</strong><br />
This product is manufactured to metric units and tolerances.<br />
United States customary units are provided for reference only. In cases where exact dimensions and tolerances are required, always refer to metric units.</p>
<h4>MAIN UNIT AND ACCESSORIES</h4>
<p>The following installation parts are supplied. Use them as required.</p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/03/image-1-133.webp" /></p>
<h4>ELECTRICAL REQUIREMENT</h4>
<table width="826">
<tbody>
<tr>
<td width="61"><strong>Use</strong></td>
<td width="77"><strong>Size</strong></td>
<td width="55"><strong>Cable type</strong></td>
<td width="100"><strong>Remarks</strong></td>
</tr>
<tr>
<td width="61"><strong> </strong></p>
<p>Remote con- troller cable (2-wire type)</td>
<td width="77"><strong> </strong></p>
<p>16~22AWG (0.33 to 1.25 mm2)</td>
<td width="55"><strong> </strong></p>
<p>Sheathed PVC cable*</td>
<td width="100">Non-polar 2 core, twisted pair Maximum cable length: 1,640 ft (500m)</td>
</tr>
<tr>
<td width="61">Remote con- troller cable (3-wire type)</td>
<td width="77">22AWG (0.33 mm2)</td>
<td width="55"><strong> </strong></p>
<p>Sheathed PVC cable*</td>
<td width="100">Polar 3core Maximum cable length: 82 ft (25m)</td>
</tr>
<tr>
<td width="61">Thermostat wires</td>
<td width="77">18AWG (0.82 mm2)</td>
<td width="55">Sheathed PVC cable*</td>
<td width="100">Maximum cable length: 164 ft (50m)</td>
</tr>
</tbody>
</table>
<p>Use shielded cable in accordance with local rules for remote controller cable.</p>
<h4>SELECTING AN INSTALLATION LOCATION</h4>
<h5>Dimensions</h5>
<p>This product is comprised of a body and cover.</p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/03/image-2-150.webp" /></p>
<p>Set the bottom side to a flat place.</p>
<h4>Specifications</h4>
<table width="760">
<tbody>
<tr>
<td colspan="2" width="173"><strong>Power consumption (W)</strong></td>
<td width="120">0.6</td>
</tr>
<tr>
<td rowspan="2" width="111"><strong>Temperature °F (°C)</strong></td>
<td width="62"><strong>Operating</strong></td>
<td width="120">32–114 (0–46)</td>
</tr>
<tr>
<td width="62"><strong>Packaged</strong></td>
<td width="120">14–140 (-10–60)</td>
</tr>
<tr>
<td width="111"><strong>Humidity (%)</strong></td>
<td width="62"><strong>Packaged</strong></td>
<td width="120">0–95 (RH);</p>
<p>No condensation</td>
</tr>
<tr>
<td colspan="2" width="173"><strong>Dimensions</strong></p>
<p><strong>H x W x D  in (mm)</strong></td>
<td width="120">1-1/16 × 3-7/16 × 3-7/16 (27 × 86.7 × 86.7)</td>
</tr>
<tr>
<td colspan="2" width="173"><strong>Weight oz. (g)</strong></td>
<td width="120">4 (100)</td>
</tr>
</tbody>
</table>
<h4>WIRING</h4>
<p><strong>WARNING:</strong></p>
<p>Before starting installation work, turn off the power of this product and the connection destination. Do not turn on the power again until installation is completed. Otherwise, it will cause electric shock or fi re.</p>
<p>Use the accessories or specified connection cable. Do not modify power supply cable and connection cables other than those specified, do not use extension cables, and do not use independent branch wiring. It may cause electric shock or fi re.</p>
<p>Install the connection cables securely to the terminal block. Confirm that external force of the cable is not applied to the terminal block. Use the specified cables. If intermediate connection or insertion fi xing are imperfect, it will cause electric shock, fire, etc.</p>
<p>When connecting the connection cable, route the cables so that the cover of this product is securely fixed. If the cover is imperfectly fixed, it may cause fi re or overheating of the terminals.</p>
<p>Perform earth (ground) work positively. Do not connect the earth (ground) cable to a telephone cable, water pipe, or conductor rod.<br />
Perform all wiring works so that the user does not touch the wiring. Otherwise it will cause injury or electric shock.<br />
If any cable is damaged, do not repair or modify it yourself. Improper work will cause electric shock or fire.</p>
<p><strong>CAUTION:</strong></p>
<p>Do not bind the remote controller cable and the external input cable together with or parallel to the power supply cable of the indoor and outdoor units. It may cause erroneous operation.</p>
<p>When performing wiring work, be careful not to damage the cable or injure yourself. Also, connect the connectors securely. Loose connectors will cause trouble, heating, fi re, or electric shock.</p>
<p>Install the indoor unit, outdoor unit, power supply cable, transmission cable and remote control cable at least 40 in (1 m) away from a television or radio.</p>
<p>The purpose of this is to prevent TV reception interference or radio noise. (Even if they are installed more than 40 in (1 m) apart, you could still receive noise under some signal conditions.)</p>
<p>Perform wiring so that water does not enter this product along the external wiring. Always install a trap to the wiring or take other countermeasures.<br />
Otherwise it will cause trouble or electric shock or fire.</p>
<p>Confirm the name of each unit and name of each terminal block of the unit and connect the wiring in accordance with the directions given in the manual so that there is no incorrect wiring. Incorrect wiring will damage the electric parts and cause smoke and fire.</p>
<p>When installing the connection cables near a source of electromagnetic waves, use shielded cable.</p>
<p>Otherwise, a breakdown or malfunction could result.<br />
The terminal screws and earth (ground) screws have different shapes. Be sure to install the screws in the correct locations. If the screws are installed in the wrong locations, the circuit board could be damaged.</p>
<h5>Wiring method</h5>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/03/image-3-128.webp" /></p>
<p>The connection example of thermostat convertor and thermostat controller is shown below.<br />
The connection method is different depending on the type of thermostat controller. Connect them according to the following Cases.<br />
For remote controller cable, 2 kinds of type, which are 2-wire type and 3-wire type are available depending on the device to be connected.</p>
<ol>
<li>All wiring shown should be performed with 18 AWG thermostat wire.</li>
<li>Terminals to thermostat controller on this product support 20-30VAC.</li>
<li>High/medium/low fan signals are optional, and may not be available on all thermostat models.</li>
<li>W2 and Y2 signals are optional, and may be omitted for single-stage thermostats. In addition, if Y2 and W2 are used, turn ON the DIP switches SET3-1.</li>
</ol>
<p><strong>Case 1: Two-stage Cooling and Heating<br />
(Example: Remote controller for 3-wire type)</strong></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/03/image-4-114.webp" /></p>
<p>Install the transformer, as necessary, per building code and manufacturer’s installation instructions. Maximum Power: 5.0VA</p>
<p><strong>Case 2: Single-stage Cooling and Heating<br />
(Example: Remote controller for 2-wire type)</strong></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/03/image-5-101-1.webp" /></p>
<p><strong>Case 3: Single-stage Cooling and Heating with Dedicated Fan<br />
Speed Relays (Example: Remote controller for 2-wire type)</strong></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/03/image-6-95.webp" /></p>
<p>The names of terminal connected to thermostat have the following meanings.</p>
<table width="532">
<tbody>
<tr>
<td width="30">TC</td>
<td width="186">Common (In) from transformer</td>
</tr>
<tr>
<td width="30">C</td>
<td width="186">Common to thermostat controller</td>
</tr>
<tr>
<td width="30">TR</td>
<td width="186">Power supply from transformer</td>
</tr>
<tr>
<td width="30">R</td>
<td width="186">Power supply to thermostat controller</td>
</tr>
<tr>
<td width="30">G3</td>
<td width="186">Airflow High</td>
</tr>
<tr>
<td width="30">G2</td>
<td width="186">Airflow Medium</td>
</tr>
<tr>
<td width="30">G1</td>
<td width="186">Airflow Low</td>
</tr>
<tr>
<td width="30">Y2</td>
<td width="186">Cooling Stage 2</td>
</tr>
<tr>
<td width="30">Y1</td>
<td width="186">Cooling Stage 1</td>
</tr>
<tr>
<td width="30">W2</td>
<td width="186">Heating Stage 2</td>
</tr>
<tr>
<td width="30">W1</td>
<td width="186">Heating Stage 1</td>
</tr>
<tr>
<td width="30">G</td>
<td width="186">Fan</td>
</tr>
</tbody>
</table>
<p><strong>NOTES:</strong></p>
<ul>
<li>Up to 16 indoor units may be controlled with a single thermostat controller, Multiple indoor units connected to convertor operate by the same operating setting.</li>
<li>Two or more types of VRF1 system, VRF2 system, single model or multi systems cannot be mixed together.</li>
</ul>
<h5>Unit wiring</h5>
<p><strong>Thermostat cable and Remote controller cable<br />
Thermostat cable</strong></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/03/image-7-84.webp" /></p>
<p><strong>Remote controller cable</strong></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/03/image-8-75.webp" /></p>
<p><strong>WARNING:</strong></p>
<p>Tighten the terminal screws to the specified torques, otherwise, abnormal overheating may be occurred and possibly cause heavy damage inside the unit.</p>
<table width="578">
<tbody>
<tr>
<td colspan="2" width="283"><strong>T</strong><strong>ightening</strong> <strong>torque</strong></td>
</tr>
<tr>
<td width="141">M2 screw</p>
<p>Remote controller / Y1, Y2, Y3 Thermostat input / G, W1, W2, Y1, Y2, G1, G2, G3, R, TR, C, TC</td>
<td width="141">1.9 to 2.2 lbf·in (0.22 to 0.25 N·m) (2.2 to 2.5 kgf·cm)</td>
</tr>
</tbody>
</table>
<p><strong>CAUTION:</strong></p>
<p>To peel the sheath from the cables, use a dedicated tool that will not damage the conductor of the cable.<br />
When installing a screw on the terminal block, do not cut the cable by overtightening the screw. On the other hand, a loosen screw can cause faulty contact, which will lead to a communication failure.</p>
<h4>INSTALLING THE THERMOSTAT CONVERTOR</h4>
<p><strong>WARNING:</strong></p>
<ul>
<li>Always use the accessories and specified installation work parts. Check the state of the installation parts. Not using the specified parts will cause units to fall off, electric shock, fi re, etc.</li>
<li>Install at a place that can withstand the weight of the unit and install positively so that the unit will not topple or fall.</li>
<li>When installing this product, make sure that there are no children nearby.<br />
Otherwise, injury or electric shock could result.</li>
</ul>
<p><strong>CAUTION:</strong></p>
<ul>
<li>Do not set the DIP switch of this product except as specified in this installation manual or the instruction manual supplied with the air conditioner. Setting the switches other than specified will cause an accident or trouble.</li>
<li>Use an insulated screwdriver to set the DIP switches.</li>
<li>Before opening the cover of this product, completely discharge static electricity charged on your body. Otherwise, failure or malfunction could result.</li>
<li>Do not touch the circuit board and circuit board parts directly with your hands. Otherwise, injury or electric shock could result.</li>
<li>Tightening the mounting screws too tight will damage the body of this product.</li>
<li>When using the indoor unit without Fan mode, do not connect G (Fan), G1, G2, and G3 signals. Otherwise air conditioner might operate incorrectly.</li>
<li>If the air conditioner system is a heat pump type, please select “ Priority on Administrative Indoor Unit” in the setting of priority mode by PUSH SWITCH of outdoor unit (refer to installation manual of outdoor unit). Furthermore, please<br />
complete “Administrative Indoor Unit Setting” for indoor unit which is connected to this Thermostat Convertor by using the wired remote controller (refer to installation manual of remote controller.)</li>
</ul>
<p><strong>NOTES:</strong></p>
<p>When this product is used, do not use the remote controller because indoor unit is controlled centrally by thermostat controller.</p>
<p>However, the remote controller connecting is temporarily required for the initial setting. During the initial setting by remote controller do not connect Thermostat Convertor to indoor unit.<br />
After when all initial setting is completed, disconnect the wired remote controller. Then connect Thermostat Converter to indoor unit at first time.</p>
<h5>Connecting the cables</h5>
<ol>
<li>For thermostat cable, use the single wire of 18AWG thermostat wire.</li>
<li>Power-supply voltage of thermostat (TC, TR) is 20 to 30VAC.</li>
<li>Insert the cable to the connected terminal and fi x with screw using screw driver.</li>
<li>For remote controller cable, 2 kinds of 2 kinds of type, which are 2-wire type and 3-wire type are available depending on the device to be connected.</li>
<li>The number of connected thermostat cable is different the type of thermostat controller.</li>
<li>For details of connection method, refer to Case 1 to Case 3 of “5. Wiring”.</li>
</ol>
<h4>CONNECTION OF REMOTE CONTROLLER CABLE</h4>
<p><strong>CAUTION:</strong></p>
<p>When connecting the remote controller cable to the indoor unit, do not connect it to the outdoor unit or the power terminal block. It may cause a failure.</p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/03/image-9-65.webp" /></p>
<p>There are 2 methods to connect the remote controller cable to the indoor unit. One is the connection using connecting cable contained by indoor unit, and the other is the connection the remote controller cable is connected to the exclusive terminal block of the indoor unit.<br />
Exclusive terminal block for remote controller connection method is different depending on each model. Modify the remote controller cable as per below description and connect it. (For the details, refer to the installation manual of the indoor unit to be used.)</p>
<h5>When connecting to the connector</h5>
<p><strong>Case 1: For non-polar 2-wire</strong><br />
Use a tool to cut off the terminal on the end of the remote controller cable, and then remove the insulation from the cut end of the cable as shown in Fig. 1. Connect the remote controller cable and connecting cable as shown in Fig. 2. Be sure to insulate between the cables.</p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/03/image-10-57.webp" /></p>
<p>Insert it to the connector. Set to “2WIRE” the DIP switch (SW1) on the PC board of the indoor unit.</p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/03/image-11-47.webp" /></p>
<p><strong>Case 2: For polar 3-wire</strong><br />
Modify the cable as per below methods.<br />
Use a tool to cut off the terminal on the end of the remote controller cable, and then remove the insulation from the cut end of the cable as shown in Fig. 1.<br />
Connect the remote controller cable and connecting cable as shown in Fig. 2.<br />
Be sure to insulate between the cables.</p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/03/image-12-41.webp" /></p>
<p>When the board has the 2WIRE/3WIRE DIP switch on it, set it to 3WIRE.<br />
For how to set, see “Case 1: For non-polar 2-wire”.</p>
<h5>When connecting to the exclusive terminal block</h5>
<p>Connect the end of remote controller cable directly to the exclusive terminal block.<br />
If there is the 2WIRE/3WIRE switch on the PC board of the indoor unit, set it to match the connection method of the connected remote controller cable.<br />
Example) Connection of non-polar 2-wire</p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/03/image-13-35.webp" /></p>
<h4>CIRCUIT BOARD SETTING</h4>
<p>Remove the cover of main unit by the following procedure to perform the initial setting.</p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/03/image-14-31.webp" /></p>
<p><strong>Tightening torque</strong></p>
<p>M3 screw                  4.4 to 5.3 lbf·in<br />
(0.5 to 0.6 N·m)<br />
(5 to 6 kgf·cm)</p>
<p>When the cover is removed, the circuit board appears.<br />
The circuit board has DIP switches and LEDs as shown below.</p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/03/image-15-23.webp" /></p>
<p>Perform the initial setting using 3 DIP switches (SET 1 to 3) on the circuit board.</p>
<p><strong>(1) 2WIRE/3WIRE setting (SET1)</strong><br />
Remote controller 2WIRE/3WIRE switching SW<br />
“Factory setting : 2WIRE”<br />
Set matched with the connection method of the remote controller cable to be connected.</p>
<p><strong>(2) Single-stage or Two-stage setting</strong></p>
<p><strong>SW SET3-1                             Contents</strong><br />
OFF                          Temperature setting: Single-stage<br />
ON                            Temperature setting: Two-stage</p>
<p><strong>(3) Temperature setting</strong><br />
<strong>Single-stage setting</strong><br />
Cooling setting temperature</p>
<table width="530">
<tbody>
<tr>
<td width="114">SW SET3-2</td>
<td width="125">Cooling Stage 1 setting temperature</p>
<p>°F (°C)</td>
<td width="50">Remarks</td>
</tr>
<tr>
<td width="114">OFF«</td>
<td width="125">64 (18)</td>
<td width="50">Pattern1</td>
</tr>
<tr>
<td width="114">ON</td>
<td width="125">68 (20)</td>
<td width="50">Pattern2</td>
</tr>
</tbody>
</table>
<p><strong>Heating setting temperature</strong></p>
<table width="709">
<tbody>
<tr>
<td width="57">SW SET3-3</td>
<td width="57">SW SET3-4</td>
<td width="129">Heating Stage 1 setting temperature</p>
<p>°F (°C)</td>
<td width="50">Remarks</td>
</tr>
<tr>
<td width="57">OFF«</td>
<td width="57">OFF«</td>
<td width="129">86 (30)</td>
<td width="50">Pattern1</td>
</tr>
<tr>
<td width="57">OFF</td>
<td width="57">ON</td>
<td width="129">81 (27)</td>
<td width="50">Pattern2</td>
</tr>
<tr>
<td width="57">ON</td>
<td width="57">OFF</td>
<td width="129">75 (24)</td>
<td width="50">Pattern3</td>
</tr>
<tr>
<td width="57">ON</td>
<td width="57">ON</td>
<td width="129">70 (21)</td>
<td width="50">Pattern4</td>
</tr>
</tbody>
</table>
<h5>Two-stage setting</h5>
<p>Cooling setting temperature</p>
<table width="718">
<tbody>
<tr>
<td width="57">SW SET3-2</td>
<td width="93">Cooling Stage 1 setting temperature</p>
<p>°F (°C)</td>
<td width="93">Cooling Stage 2 setting temperature</p>
<p>°F (°C)</td>
<td width="50">Remarks</td>
</tr>
<tr>
<td width="57">OFF«</td>
<td width="93">68 (20)</td>
<td width="93">64 (18)</td>
<td width="50">Pattern1</td>
</tr>
<tr>
<td width="57">ON</td>
<td width="93">72 (22)</td>
<td width="93">68 (20)</td>
<td width="50">Pattern2</td>
</tr>
</tbody>
</table>
<p>Heating setting temperature</p>
<table width="735">
<tbody>
<tr>
<td width="57">SW SET3-3</td>
<td width="57">SW SET3-4</td>
<td width="64">Heating Stage 1 setting temperature</p>
<p>°F (°C)</td>
<td width="64">Heating Stage 2 setting temperature</p>
<p>°F (°C)</td>
<td width="50">Remarks</td>
</tr>
<tr>
<td width="57">OFF«</td>
<td width="57">OFF«</td>
<td width="64">81 (27)</td>
<td width="64">86 (30)</td>
<td width="50">Pattern1</td>
</tr>
<tr>
<td width="57">OFF</td>
<td width="57">ON</td>
<td width="64">77 (25)</td>
<td width="64">82 (28)</td>
<td width="50">Pattern2</td>
</tr>
<tr>
<td width="57">ON</td>
<td width="57">OFF</td>
<td width="64">75 (23)</td>
<td width="64">79 (26)</td>
<td width="50">Pattern3</td>
</tr>
<tr>
<td width="57">ON</td>
<td width="57">ON</td>
<td width="64">70 (21)</td>
<td width="64">75 (24)</td>
<td width="50">Pattern4</td>
</tr>
</tbody>
</table>
<p><strong>NOTES:</strong></p>
<p>These are the limit temperature for cooling and heating.<br />
Energy saving performance is improved in the order from Cooling Pat- tern 1 to 2 and Heating Pattern 1 to 4.</p>
<h5>Delay off setting</h5>
<table width="753">
<tbody>
<tr>
<td width="68">SW SET2-3</td>
<td width="68">SW SET2-4</td>
<td width="156">Delay off time</td>
</tr>
<tr>
<td width="68">OFF«</td>
<td width="68">OFF«</td>
<td width="156">0 minutes</td>
</tr>
<tr>
<td width="68">OFF</td>
<td width="68">ON</td>
<td width="156">5 minutes</td>
</tr>
<tr>
<td width="68">ON</td>
<td width="68">OFF</td>
<td width="156">10 minutes</td>
</tr>
<tr>
<td width="68">ON</td>
<td width="68">ON</td>
<td width="156">20 minutes</td>
</tr>
</tbody>
</table>
<p><strong>NOTES:</strong></p>
<p>These are the limit temperature for cooling and heating.<br />
Energy saving performance is improved in the order from Cooling Pattern 1 to 2 and Heating Pattern 1 to 4.</p>
<p>Delay OFF:<br />
Delay OFF is the function to operate continuously after reaching to the<br />
setting temperature of thermostat.<br />
This function may make the air conditioning effi cient.<br />
Set the Delay OFF time by SW SET 2-3 and SW SET 2-4.</p>
<h5>Fan setting (G signal)</h5>
<table width="575">
<tbody>
<tr>
<td width="68">SW SET2-1</td>
<td width="68">SW SET2-2</td>
<td width="156">Indoor unit airflow</td>
</tr>
<tr>
<td width="68">OFF«</td>
<td width="68">OFF«</td>
<td width="156">Auto</td>
</tr>
<tr>
<td width="68">OFF</td>
<td width="68">ON</td>
<td width="156">High</td>
</tr>
<tr>
<td width="68">ON</td>
<td width="68">OFF</td>
<td width="156">Med.</td>
</tr>
<tr>
<td width="68">ON</td>
<td width="68">ON</td>
<td width="156">Low</td>
</tr>
</tbody>
</table>
<h4><strong>TURNING ON THE POWER</strong></h4>
<ol>
<li>Check this product wiring and switch settings on the circuit board.</li>
<li>Check the wiring and switch settings for the VRF system or multi system or single model. For the wiring and switch settings method, refer to the installation instruction sheet of each unit.</li>
<li>Turn on the power for the VRF system etc.</li>
<li>Power will be supplied from the indoor unit to this product.</li>
</ol>
<ul>
<li>This product will be initialized and the power turned on. LED1 (green) and LED2 (orange) will fl ashing.</li>
<li>After initial setting is completed, operation will be restarted automatically. LED1 (green) lights.</li>
<li>This product does not operate during initialization.</li>
<li>An error code will appear on LED in the event of a malfunction.</li>
</ul>
<h4>LED DISPLAY</h4>
<h5>Normal code</h5>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/03/image-16-18.webp" /></p>
<h5>Error code</h5>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/03/image-17-15.webp" /></p>
<p><strong>USAGE</strong></p>
<p>For the usage and installation of thermostat controller, refer to the operating manual and installation manual of thermostat controller.</p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/03/logo-3.png" /></p>
<form id="commentform" class="comment-form" action="https://manuals.plus/wp-comments-post.php" method="post" novalidate="">
<p class="form-submit"><input id="comment_post_ID" name="comment_post_ID" type="hidden" value="311954" /><br />
<input id="comment_parent" name="comment_parent" type="hidden" value="0" /></p>
</form>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>FUJITSU 9387602227 Air Conditioner Manual</title>
		<link>https://usemanuals.com/fujitsu/9387602227-air-conditioner/</link>
		
		<dc:creator><![CDATA[ItsManual]]></dc:creator>
		<pubDate>Fri, 23 Jun 2023 08:51:09 +0000</pubDate>
				<category><![CDATA[FUJITSU]]></category>
		<guid isPermaLink="false">https://usemanuals.com/?p=114284</guid>

					<description><![CDATA[9387602227 Air Conditioner Instruction Manual  Before using this product, read these instructions thoroughly and keep this manual for future reference. MODEL: * Write down the model name. (Refer to the rating label.) SAFETY PRECAUTIONS To prevent personal injury or property damage, read this section carefully before you use this product, and be sure to comply with the following safety precautions. Incorrect operation due to failure to follow the instructions may cause harm or damage, the seriousness of which is classiﬁ ed as follows: WARNING This mark warns of death or serious injury. CAUTION This mark warns of injury or damage to property. This mark denotes an action that is PROHIBITED. This mark denotes an action that is COMPULSORY. WARNING This product contains no user-serviceable parts. Always consult authorized service personnel for repair, installation, and relocation of this product. Improper installation or handling will cause leakage, electric shock, or ﬁ re. In the event of a malfunction such as a burning smell, immediately stop the operation of the air conditioner, and disconnect all the power supply by turning off the electrical breaker or disconnecting the power plug. Then consult authorized service personnel. Take care not to damage the power supply cable. If it is damaged, it should be replaced only by authorized service personnel in order to avoid a hazard. If a refrigerant leakage is suspected, all naked ﬂames shall be removed or extinguished, and consult authorized service personnel. In the event of a thunderstorm or any prior sign of a lightning strike, turn off the air conditioner via the remote controller, and refrain from touching the product or the power source to prevent any electrical hazards. This product is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge unless they have been given supervision or instruction concerning the use of this product by a person responsible for their safety. Children should be supervised to ensure that they do not play with this product. Dispose of the packing materials safely. Tear and dispose of the plastic packing bags so that children cannot play with them. There is a danger of suffocation if children play with the original plastic bags. Do not start or stop the operation of this product by inserting or pulling out the power plug, or by turning on or off the circuit breaker. Do not use ﬂammable gases near this product. Do not expose yourself directly to the cooling airﬂow for many hours. Do not insert your ﬁngers or any other objects into the outlet port or inlet port. Do not operate with wet hands. CAUTION Provide occasional ventilation during use. Always operate this product with air ﬁ lters installed. Ensure that any electronic equipment is at least 40 in (1 m) away from this product. Disconnect all the power supply when not using this product for extended periods. After a long period of use, ensure to get the mounting of the indoor unit checked to prevent this product from falling down. The airﬂ ow direction and the room temperature should be carefully considered when you use this product in a room with infants, children, elderly or sick persons. Keep the surroundings of the outdoor unit clean and tidy, and do not place items around it. Any objects blocking or entering from the outlet ports may cause product malfunction. Do not direct the airﬂ ow at ﬁreplaces or heating apparatus. Do not block or cover the intake grille and the outlet port. Do not apply any heavy pressure to the radiator ﬁns. Do not climb on, place objects on, or hang objects from this product. Do not place any other electrical products or household belongings under this product. Dripping condensation from this product might get them wet, and may cause damage or malfunction of your property. Do not expose this product directly to water. Do not use this product for the preservation of food, plants, animals, precision equipment, artwork, or other objects. This may cause quality deterioration of those items. Do not expose animals or plants to the direct airﬂ ow. Do not drink the drainage from the air conditioner. Do not pull the power supply cable. Do not touch the aluminum ﬁ ns of the heat exchanger built in this product to avoid personal injury when you maintain the unit. Do not stand on unstable steps when operating or cleaning this product. It may overturn and can cause injury. PREPARATION WARNING Take care to prevent infants and young children from accidentally swallowing the batteries. CAUTION If leaking battery ﬂuid comes in contact with your skin, eyes, or mouth, immediately rinse with plenty of clean water, and consult your physician. Exhausted batteries must be removed immediately, and be disposed of according to the local laws and regulations of your region. Do not attempt to recharge dry batteries. Do not use dry batteries that have been recharged. Indoor unit accessories  Check that the following accessories are included. Remote controller holder installation  NAME OF PARTS CAUTION For appropriate signal transmission between the remote controller and the indoor unit, keep the signal receiver away from the following items: Direct sunlight or other strong lights Flat-panel television screen In rooms with instantaneous ﬂ fluorescent lights, such as inverter-type ones, the signal may not be transmitted properly. In such a case, consult the store of purchase. 3.1. Remote controller CAUTION To prevent malfunction or damage of the remote controller: Place remote controller at where will not be exposed to direct sunlight or excessive heat. Remove batteries if the product is not going to be used for an extended period. Obstacles such as a curtain or wall between the remote controller and the indoor unit may affect the appropriate signal transmission. Do not apply strong shocks to the remote controller. Do not pour water on the remote controller. When you use the optional remote controller, the appearance and the operation procedure may differ. For details, refer to the operation manual of each remote controller. 3.2. Inserting batteries Battery type: R03/LR03/AAA × 2 1~3. Put batteries as shown in the ﬁ gure above. Press as shown in the ﬁ gure above. NOTES: Use speciﬁ ed types of batteries only. Do not mix different types of new and used batteries together. Batteries can be used for about 1 year in ordinary use. If the remote control range noticeably shortens, replace the batteries, and presses shown in the ﬁ gure above. 3.3. Indoor unit  : The instruction is related to the wireless LAN control (optional). Before starting the operation, make sure that the intake grille is closed completely. Incomplete closing may affect the proper function or performance of the product. Indicator lamps light in the following conditions. Name Color Operation or condition Operation Green Normal operation Timer Orange Timer operation Economy Green Economy operation Minimum Heat operation (optional) WLAN Orange Wireless LAN control is active. BASIC OPERATIONS 3 steps to start operation Press/I to start or stop the operation. Press MODEto select the operation mode. The operation mode changes as follows. Press to set the desired temperature. The temperature changes by 1 °F (0.5 °C) increments. Temperature setting range Auto/Cooling/Dry 64-88 °F (18.0-30.0 °C) Heating 60-88 °F (16.0-30.0 °C) NOTES: In the Cooling or Dry mode, set the temperature lower than the current room temperature. In the Heating mode, – set the temperature higher than the current room temperature. – at the beginning of the operation, the indoor unit fan rotates at very low speed for 3-5 minutes. – the Automatic defrosting operation overrides the Heating operation when necessary. In the Fan mode, temperature control is not available. ■ Temperature unit switching 5.1. Fan speed setting Press FAN SPEED to control the fan speed. The fan speed changes as follows. When AUTO is selected, the fan speed depends on the operating condition. NOTE: In the Dry mode, the fan speed is ﬁxed to AUTO. 5.2. Airﬂ ow direction setting For details of the airﬂ ow ranges, refer to “Airﬂ ow direction range”. Up/down airﬂ ow direction setting Press to adjust the up/down airﬂ ow direction. Left/right airﬂ ow direction setting Press to adjust the left/right airﬂ ow direction. Swing operation setting Press SWING to select the Swing operation. The Swing operation changes as follows.  NOTE: The Swing operation may stop temporarily when the indoor unit fan is rotating at very low speed or is stopped. Airﬂ ow direction range Up/down airﬂ ow direction  The Swing operation range depends on the airﬂ ow direction set before the Swing operation. NOTES: Do not adjust the horizontal louvers by hand. In the Auto or Heating mode, the airﬂ ow direction stays at position 1 for a while from the start of the operation. In the Cooling or Dry mode, position 1-3 is recommended to prevent condensation drips from damaging your property. If position 4-6 keeps for 30 minutes or more in these modes, the airﬂ ow direction changes to position 3 automatically. When using the mobile app (an optional WLAN adapter is necessary), the up/down airﬂ ow can be selected from 4 positions. Left/right airﬂ ow direction NOTE: In the Auto mode operation, you cannot change the airﬂow direction for a while from the start of the operation. TIMER OPERATIONS NOTE: When [ ] indicator on the indoor unit blinks, set the clock and timer again. This blinking shows that the internal clock goes wrong due to an interruption of the power supply. ■ Timer setting procedure Pressto choose timer operation. Each time you press the button, the timer operation will change as follows: Off timer Stops the operation at your desired time. On timer Starts the operation at your desired time. Program timer Operates as the combination of the On timer and Off timer. Cancel Deactivate the timer. • If you choose “Cancel”, the display returns to the operation display. • To set a sleep timer, press SLEEP. (Refer to “6.3. Sleep timer”.) Set each timer operation. For details, refer to the following instructions of each timer setting. 6.1. On timer or Off timer Select On timer or Off timer in step 1 of “Timer setting procedure.” Each time you press, the time changes as follows: When you use the On timer, set the time while the indicator on the remote controller display is blinking. When you use the Off timer, set the time while the indicator on the remote controller display is blinking. To deactivate the On/Off timer, select Cancel in step 1 of “Timer setting procedure” while [ ON] or [ OFF] is shown on the remote controller display. The indicator will disappear. NOTE: If you set the Sleep timer after setting the On/Off timer, the On/Off timer is canceled. 6.2. Program timer Set On Timer and Off timer. (Refer to “6.1. On timer or Off timer”.) Select Program timer in step 1 of “Timer setting procedure”. After the time set by the earlier timer passed, the timer set later will begin the counting down. The order of the timer operation is displayed as follows: Timer The indicator on the remote controller display Off→On timer ON ▲ OFF On →Off timer ON ▼ OFF NOTE: If you set the Sleep timer after setting the Program timer, the Program timer is canceled. 6.3. Sleep timer The Sleep timer supports your comfortable sleep by moderating the air conditioner operation gradually. Press SLEEP. Each time you press the button, the time changes as follows: To repeat the timer, press the button when the SLEEP indicator is not displayed. During the Sleep timer operation, the setting temperature changes as the following ﬁ gure. After the set time has elapsed, the air conditioner operation turns off. ENERGY SAVING OPERATION 7.1. Economy operation It saves more electricity than other operation modes by changing the set temperature to a moderate setting. Press to activate/deactivate the Economy operation. [ ] indicator on the indoor unit will turn on. Operation mode Room temperature Cooling/Dry Few degrees higher than the set temperature Heating Few degrees lower than the set temperature NOTES: In the Cooling, Heating, or Dry mode, the maximum output of this operation is approximately 70 % of the usual operation. This operation cannot be performed during the temperature monitoring by the Auto mode. 7.2. Fan control for energy saving  In the Cooling operation, when the room temperature reaches the set temperature, the indoor unit fan rotates intermittently to save power. (This function is deactivated at the  time of purchase.) To change the setting, use the following steps; Press until the indicators on the remote controller turn off. Press and hold FAN SPEED for more than 5 seconds. The and the current status will appear. ON: Activated OFF: Deactivated Press to switch the status. Press to send the set to the indoor unit. The display will return to the original screen. NOTE: If you do not press any buttons for 30 seconds after are displayed, will turn off. In this case, repeat the setting from step 2. OTHER OPERATIONS 8.1. Powerful operation In the Powerful operation, the air conditioner will operate at maximum power and strong airﬂ ow to cool down or warm up the room quickly. Press POWERFULL to activate/deactivate the Powerful operation. When activated, the indoor unit will emit 2 short beeps. When deactivated, the indoor unit will emit 1 short beep. The Powerful operation will be turned off automatically in the following situations: The Powerful operation runs for a certain amount of time and the room temperature reaches the set temperature in the Cooling, Dry, or Heating mode. 20 minutes after the Powerful operation has started. NOTES: The airﬂ ow direction and the fan speed are controlled automatically. The Powerful operation cannot be performed simultaneously with the Economy operation. If the wired remote controller (optional) is connected, this function is restricted. 8.2. Minimum heat operation (optional) NOTE: This function is available only by the wireless LAN control (optional). Minimum heat operation maintains the room temperature at 50 °F (10 °C) so as to prevent the room temperature to drop too low. – When activated, [ ] indicator on the indoor unit will turn on. – When deactivated, [ ] indicator will turn off. NOTES: During the Minimum heat operation, only the up/down and left/right airﬂ ow direction settings are valid. When the room temperature is warm enough, This operation will not be performed. SETTINGS ON INSTALLATION 9.1. Remote controller custom code setting By setting the custom code of the indoor unit and remote controller, you can specify the air conditioner which the remote controller controls. When two or more air conditioners are in the room and you wish to operate them separately, set the custom code (4 selections possible). NOTE: If custom codes is different between the indoor unit and the remote controller, the indoor unit cannot receive a signal from the remote controller. How to set the remote controller custom code Pressuntil the indicators on the remote controller turn off. Press down MODE for more than 5 seconds. The current custom code will be displayed (initially set to A). Press to change the custom code between * Match the custom code on the display to the air conditioner custom code. Press MODE again. The custom code will be set. The display will return to the original display. To change the air conditioner custom code, contact authorized service personnel (initially set to A). If you do not press any buttons for 30 seconds after the custom code is displayed, the displayed custom code is set and the display returns to the original display. Depending on the remote controller, the custom code may return to A when replacing the batteries. In this case, reset the custom code as necessary. If you do not know the air conditioner custom code, try each code until you ﬁnd the code which operates the air conditioner. CLEANING AND CARE CAUTION Before cleaning this product, be sure to turn it off and disconnect all the power supply. Before starting the operation, make sure that the intake grille has been shut completely. Incomplete closing of the intake grille might have an effect on the proper working or performance of the air conditioner. If the ﬁ lter cleaning involves high-place work, consult the authorized service personnel. Do not touch the aluminum ﬁ ns of the heat exchanger built-in in the indoor unit to avoid personal injury when you maintain the unit. Do not expose the indoor unit to liquid insecticides or hair sprays. Do not stand on slippery, uneven, or unstable surfaces when you maintain the unit. The frequency of the cleaning is shown in the following table. What to do Frequency Indoor unit body Cleaning When you notice Air filter Cleaning Every 2 weeks Apple-catechin filter (UTR-FA16) (White) Replacing Every 3 months Ion deodorization filter (UTR-FA16-2) (Light blue) Cleaning Every 3 months Replacing Every 3 years The air cleaning ﬁ lters are sold separately. When you replace them, contact the store of purchase. Cleaning the indoor unit body NOTES: Do not use water hotter than 104 °F (40 °C). Do not use scouring cleanser or volatile solvents such as benzene or thinner. 1. Wipe the indoor unit body gently with a soft cloth moistened with warm water. 2. Wipe the indoor unit body gently with a dry and soft cloth. Cleaning air ﬁlter Open the intake grille until it snaps. Remove the air ﬁlters. Lift up the air ﬁlters’ handle, disconnect the two lower tabs, and pull out. Remove the dust in either of the following ways. • Cleaning with a vacuum cleaner. • Washing with mild detergent and warm water. After washing, dry the air ﬁlters thoroughly in shade. Replace the air ﬁ lters. Align the sides of the air ﬁ lter with the panel, and push in fully. Make sure to the two lower tabs are returned to their holes in the indoor unit properly. Close the intake grille. Press 4 places on the intake grille to close it completely. NOTE: If dirt accumulates on the air ﬁ lter, airﬂ ow will be reduced, operating efﬁciency will lower, and the noise will increase. Cleaning Ion deodorization ﬁ lter and Replacing Apple-catechin ﬁlter Remove the air ﬁ lters. Refer to steps 1 ~ 2 of “Cleaning air ﬁlter”. Remove the air cleaning ﬁ lters from the air cleaning ﬁlter holders. Flush the Ion deodorization ﬁ lter with high-pressure hot water until the surface of the ﬁlters are covered with water. Wash the Ion deodorization ﬁ lter with a diluent neutral detergent. Do not ream or rub, otherwise, the deodorizing effect may decrease. Rinse the Ion deodorization ﬁ lter with water ﬂow. Dry the Ion deodorization ﬁ lter in shade. Set the new or washed air cleaning ﬁ lters into the air cleaning ﬁ lter holders. NOTE: Use the Apple-catechin ﬁ lter as soon as possible after opening the package. The air cleaning effect decreases when the ﬁ lters are left in the opened package. Install the air cleaning ﬁ lter holders to the air ﬁ lters. Engage the 4 hooks at the rear of the air cleaning ﬁ lter holder with the latch at both ends of the air ﬁlter. NOTE: Take care that the air cleaning ﬁ lter does not project beyond the holder. Replace the air ﬁ lters and close the intake grille. Refer to steps 4 ~ 5 of “Cleaning air ﬁlter”. Removing and installing intake grille Removing intake grille Open the intake grille until it snaps. Pull the mounting shafts while keeping the intake grille in a horizontal position. ■ Installing intake grille While holding the intake grille horizontal, set the left and right mounting shafts into the pillow blocks at the top of the front panel. Insert the shaft until it snaps to latch each shaft properly. Close the intake grille. Press 4 places on the intake grille to close it completely. GENERAL INFORMATION Heating performance This air conditioner operates on the heat-pump principle, absorbing heat from air outdoors and transferring that heat to the indoor unit. As a result, the operating performance is reduced as outdoor air temperature drops. If you feel that the heating performance is insufﬁ cient, we recommend you to use this air conditioner in conjunction with other kinds of heating appliances. Automatic defrosting operation When the outdoor temperature is very low with high humidity, frost may form on the outdoor unit during the heating operation, and it could reduce the operating performance of the product. For frost protection, an automatic defrost function is equipped in this air conditioner. If frost forms, the air conditioner will temporarily stop, and defrost circuit will operate brieﬂ y (maximum of 15 minutes.) [ ] indicator on the indoor unit blinks during this operation. If frost forms on the outdoor unit after the Heating operation, the outdoor unit will stop automatically after it operates for a few minutes. Then the Automatic defrosting operation starts. Auto-restart function In event of a power interruption such as a blackout, the air conditioner stops once. But it restarts automatically and performs the previous operations when the power supply is resumed. If any power interruption occurs after the timer is set, the counting down of the timer will be reset. After the power supply is resumed, the [] indicator on the indoor unit blinks to notify you that there has been a timer fault. In such a case, reset the clock and timer settings. Malfunctions caused by other electrical devices Use of other electrical appliances such as an electric shaver or nearby use of a wireless radio transmitter may cause the malfunction of the air conditioner. If you encounter such a malfunction, turn off the circuit breaker once. Then turn it on again, and resume operation by using the remote controller. Indoor unit temperature and humidity range Permissible ranges of temperature and humidity are as follows: Indoor temperature Cooling/Dry [°F (°C)] 64 to 89 (18 to 32) Heating [°F (°C)] 60 to 86 (16 to 30) Indoor humidity [%] 80 or less ‘1/41) *1) If the air conditioner is used continuously for many hours, water may condense on the surface and drip. If the unit is operated under conditions except for the permissible temperature range, the air conditioner operation may stop because of the automatic protection circuit working. Depending on the operating conditions, the heat exchanger may freeze, causing water leakage or other malfunction (in the Cooling or Dry mode). Other information Do not use the air conditioner for any purpose other than room cooling/drying, room heating, or fan. For the permissible ranges of temperature and humidity for the outdoor unit, refer to the outdoor unit installation manual. Emergency heat (Special setting) An auxiliary heater can be used instead of the outdoor unit if the auxiliary heater is connected and the function is set correctly during installation. Consult authorized service personnel to use this function. To activate/deactivate this function, Press on the indoor unit for 2 seconds or less during the Heating operation. (Refer to page 4.) During the Emergency heat operation, [] indicator lamp will blink (3 seconds on, 1 second off). OPTIONAL PARTS 12.1. Wired remote controller The optional wired remote controller can be used. You can use wired and wireless remote controllers together. However, some functions of the wireless remote controller are restricted. If you set the restricted functions, a beeping sound will be heard, [], [ ], [ ] and [ ] indicator on the indoor unit will blink. &#60;Restricted functions for wireless remote controller&#62; When used together with a wired remote controller (2-wire) Powerful operation You can use a wired remote controller and wireless LAN control together (optional). However, some operations from the mobile app are restricted. Multiple remote controllers, You can connect two wired remote controllers to one air conditioner. Either remote controller can control the air conditioner. However, the timer functions cannot be used by the secondary unit. Group control One remote controller can control up to 16 air conditioners. All of the air conditioners will be operated with the same settings. You cannot use group control and wireless LAN control together. 12.2. Wireless LAN control To use the wireless LAN control, the WLAN adapter and mobile app are necessary. For how to operate the mobile app, refer to the operation manual of the mobile app. Write down the SSID and the PIN code in the following table. Information on WLAN adapter SSID PIN Google Play is a registered trademark of Google Inc. App Store is a service mark of Apple Inc., registered in the U.S. and other countries. Setting to use wireless LAN control Step 1. Application software installation Open “Google Play” or “App Store” depending on the type of your smartphone or tablet PC. Search for “fair”. Install the application software (mobile app) following the instructions on your screen. Step 2. User registration Open the installed mobile app. Register the user (with either a smartphone or tablet PC) by following the instructions in the create an account section of the mobile app. Step 3. Installing WLAN adapter CAUTION Be sure to turn off the power supply of the air conditioner when installing or removing this product to avoid the risk of electric shock. Do not put ﬁngers, sticks, etc. in the connection part of this product and the connection slot of the indoor unit. Otherwise, electric shock or damage to the product may occur. Do not stand on an unstable platform when installing or removing this product to avoid injury. Be sure to turn air conditioner off and to disconnect all the power supply. Open the intake grille. Open the WLAN adapter cover until it snaps. Plug the WLAN adapter into the connection slot of the indoor unit in the direction as shown in the ﬁ gure. Close the WLAN adapter cover and the intake grille. Step 4. Air conditioner registration (pairing of WLAN adapter) NOTES: Before starting this setting, reconnect the power supply of the air conditioner and wait for 60 seconds or more. Check that the smartphone or tablet PC is linked to the access point you are connecting to the air conditioner. The setting will not work if it is not connected to the same access point. To control 2 or more air conditioners with the same smartphone or tablet PC, repeat the setup of the chosen model. Register the air conditioner by following the instructions on the mobile app. This operation manual describes only the setting procedure of the remote controller. When the registration is completed, the []indicator on the indoor unit will turn on. For reference &#60;Manual connection&#62; Setting procedure of the remote controller NOTE: If you do not press any buttons on the remote controller for 60 seconds, the remote controller display will return to the original display. Press 2 times as shown in page 3. L2 will be displayed on the remote controller display. Press. Make sure that “01 ” is shown on the remote controller display. If “ 02” is shown, press to select “01 ”, Press. The indoor unit enters the Manual connection mode and the [] indicator on the indoor unit will blink. NOTE: If the registration is not ﬁnished in several minutes, the Manual mode is canceled, and the [] indicator turns off. In this case, repeat the remote controller setting. &#60;Easy connection&#62; Setting procedure of the remote controller NOTE: If you do not press any buttons of the remote controller for 60 seconds, the remote controller display will return to the original display. Press 2 times as shown in page 3. L2 will be displayed on the remote controller display. Press. Select 02 using. Press. The indoor unit enters the Easy connection mode and the []indicator on the indoor unit will blink (on/off = 1 s/1 s). When the WLAN adapter ﬁnd a connectable access point, the blinking will become slower (on/off = 2 s/0.5 s). NOTE: If the connection to the access point is not ﬁnished in several minutes, the Easy connection mode is canceled, and the [] indicator turns off. In this case, repeat the remote controller setting. Temporary deactivation of wireless LAN NOTE: If you do not press any buttons on the remote controller for 60 seconds, the remote controller display will return to the original display. Press with the tip of a ballpoint pen or other small object. “” will appear. Press. The current status will appear. Activated Deactivated Select using. Press. [] indicator on the indoor unit will turn off. * If you want to activate wireless LAN control again, select “ON” at step 3. Initialization (reset) Initialize (reset) this product in the following situations: Changing the access point Disposing of this product Transferring this product to a third party Unregister the air conditioner Unregister the air conditioner by using the mobile app. (Refer to the operation manual of the mobile app for details.) Initialization of the WLAN adapter NOTE: If you do not press any buttons on the remote controller for 60 seconds, the remote controller display will return to the original display. Press 3 times as shown in page 3. L3 will be displayed on the remote controller display. Press. “In ” will appear. Press and hold for more than 5 seconds. [] indicator on the indoor unit will blink fast, then turn off. To continue use If you or a third party wishes to continue the use of the product, follow the procedures in “Air conditioner registration (pairing of WLAN adapter)” to reconnect to a different access point. NOTE: Wireless LAN setup is not possible if the previous owner did not unregister or initialize this product. In this case, contact your authorized service personnel. Firmware update CAUTION Do not pull out the power plug nor turn off the circuit breaker during the ﬁ rmware update of the indoor unit or WLAN adapter. It may cause malfunction. For WLAN adapter The ﬁ rmware of the WLAN adapter may be updated automatically. During the update, you cannot operate the air conditioner from the mobile app. It will take a maximum of 5 minutes. For indoor unit The ﬁ rmware of the indoor unit may be updated. You can set the schedule of the updating or update the ﬁ rmware manually from the mobile app. For details, refer to the operation manual for the mobile app. During the update, the indicator lamps blink and the air conditioner stops operation. (Refer to “State of indicator lamps”.) It will take a maximum of 30 minutes. TROUBLESHOOTING In the following events, immediately stop the operation of the air conditioner, and disconnect all the power supply by turning off the electrical breaker or disconnecting the power plug. Then consult your dealer or authorized service personnel. As long as the unit is connected to the power supply, it is not insulated from the power supply even if the unit is turned off. Unit smells of something burning or emits smoke Water leaks from the unit Does not operate at all. Has there been a power outage? In this case, the unit restarts automatically after the power supply is resumed. (Refer to page 8.) Has the circuit breaker been turned off? ⇒ Turn on the circuit breaker. Has a fuse blown out or the circuit breaker been tripped? ⇒ Replace the fuse or reset the circuit breaker. Is the timer operating? ⇒ To check or deactivate the timer setting, refer to page 5. &#60;When using the wireless LAN control&#62; Is the WLAN adapter in a ﬁrmware update? During the ﬁ rmware update of the WLAN adapter, you cannot operate the air conditioner from the mobile app. Operate from the remote controller or wait until the  update is complete (for a maximum of 5 minutes). &#60;When using the wireless LAN control&#62; Is the indoor unit in a ﬁ rmware update? During the ﬁ rmware update of the indoor unit, the air conditioner stops operation. Wait until the update is complete. (for a maximum of 30 minutes). Poor cooling or heating performance. Is the unit operating under the conditions except for the permissible temperature range? In this case, the air conditioner may stop because of the automatic protection circuit working. Is the air ﬁ lter dirty? ⇒ Clean the air ﬁ lter. (Refer to page 7.) Is the intake grille or outlet port of the indoor unit blocked? ⇒ Remove the obstructions. Is the room temperature adjusted appropriately? ⇒ To change the temperature setting, refer to page 4. Is a window or door left opened? ⇒ Close the window or the door. Is the fan speed set to Quiet? ⇒ To change the fan speed, refer to page 4. &#60;In the Cooling mode&#62; Is direct or strong sunlight shining into the room? ⇒ Close the curtains. &#60;In the Cooling mode&#62;Are there other heating apparatus or computers operating, or too many people in the room? ⇒ Turn the heating apparatus or computers off, or set the temperature lower. (Refer to page 4.) Humidity does not drop during the Dry operation. You cannot set the target humidity in the Dry mode. If you feel high humidity, set the temperature lower. Airﬂ ow is weak or stops. Is the fan speed set to Quiet? ⇒ To change the fan speed, refer to page 4. Has the Fan Control for Energy Saving set? In this case, the indoor unit fan may stop temporarily while the Cooling operation. ⇒ To cancel the Fan control for energy saving, refer to page 6. &#60;In the Heating mode&#62; Have you just started the operation? In this case, the fan rotates at a very low speed temporarily to warm up the internal parts of the unit. &#60;In the Heating mode&#62; Is the room temperature higher than the set temperature? In this case, the outdoor unit stops and the indoor unit fan rotates at a very low speed. &#60;In the Heating mode&#62; Is [ ] indicator blinking? In this case, the Automatic defrosting operation is working. The indoor unit stops for a maximum of 15 minutes. (Refer to page 8.) &#60;In the Dry mode&#62; The indoor unit operates at low fan speed to adjust the room humidity and may stop from time to time. &#60;In the Auto mode&#62; While the monitoring operation, the fan rotates at a very low speed. Noise is heard. Is the unit operating, or immediately after stopping operation? In this case, refrigerant ﬂ owing sound may be heard. It may be particularly noticeable for 2-3 minutes after starting the operation. Do you hear a slight squeaking sound during the operation? This sound is produced by the minute expansion and contraction of the front panel caused by temperature change. &#60;In the Heating mode&#62; Do you hear a sizzling sound? This sound is produced by the Automatic defrosting operation. (Refer to page 8.) Smell coming from the unit. The air conditioner may absorb various smells generated from interior textile, furniture, or cigarette smoke. These smells may be emitted during the operation. Mist or steam is emitted from the unit. &#60;In the Cooling or Dry mode&#62; A thin mist may be generated by condensation formed with a sudden cooling process. &#60;In the Heating mode&#62; Is [] indicator on the indoor unit blinking? In this case, steam may rise from the outdoor unit because of the Automatic defrosting operation. (Refer to page 8.) The outdoor unit emits water. &#60;In the Heating mode&#62; The outdoor unit may emit water generated by the Automatic defrosting operation. (Refer to page 8.) The unit operates differently from the remote controller setting. Are the batteries in the remote controller exhausted? ⇒ Replace the batteries. Operation is delayed after the restart. Has the power supply turned from Off to On suddenly? In this case, the compressor will not operate for about 3 minutes to prevent a blowout of the fuse. Immediately stop operation and turn off the electrical breaker in the following cases. Then consult authorized service personnel. The problem persists even if you perform these checks or diagnostics. On the indoor unit, [ ] and [ ] blink while [ ] is blinking fast. NOTE: For any troubleshooting related to the wireless LAN control, refer to the setting manual for the WLAN adapter or the mobile app installed in your smartphone or tablet PC. State of indicator lamps : The instruction is related to the wireless LAN control (optional). Lighting pattern: Off, On, Blinking, Any state Lighting pattern: Off, On, Blinking, Any state Manual Auto operation and Filter indicator reset You can operate the air conditioner on the indoor unit. (Refer to page 4.) Status Length of pressing down Mode or operation In operation More than 3 seconds Stop Stopping 2 seconds or less Filter indicator reset More than 3 seconds and less than 10 seconds Auto More than 10 seconds (Only for servicing.) *1) Forced cooling In Heating operation 2 seconds or less (Special setting) 2) Emergency heat To stop the forced cooling, press this button or on the remote controller. Refer to “Emergency heat (page 8)” for details. Service check If [ ] and [ ] blink while [ ] is blinking fast on the indoor unit, check the error code. The error code is 2-digit numbers or characters. Press and hold for more than 5 seconds. The remote controller will enter to the Service check mode and “ will be shown. Press TEM/SLECT   to change the shown error code. The indoor unit emits 1 short beep each time the error code changes. When the corresponding error code is shown, the indoor unit emits multiple beeps, and all the indicator lamps on the indoor unit blink. To ﬁ nish the Service check mode, press. The remote controller will return to the original display. Tell the error code to authorized service personnel when consulting them. If the indoor unit emits multiple beeps at “00”, no error is detected. [...]<p><a class="btn btn-secondary understrap-read-more-link" href="https://usemanuals.com/fujitsu/9387602227-air-conditioner/">Read More...</a></p>]]></description>
										<content:encoded><![CDATA[<p><strong>9387602227 Air Conditioner</strong><br />
<strong>Instruction Manual </strong><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/06/FUJITSU-9387602227-Air-Conditioner.webp" /></p>
<p>Before using this product, read these instructions thoroughly and keep this manual for future reference.</p>
<p><strong>MODEL:</strong><br />
* Write down the model name.<br />
(Refer to the rating label.)</p>
<h4>SAFETY PRECAUTIONS</h4>
<p>To prevent personal injury or property damage, read this section carefully before you use this product, and be sure to comply with the following safety precautions.<br />
Incorrect operation due to failure to follow the instructions may cause harm or damage, the seriousness of which is classiﬁ ed as follows:</p>
<p><strong><img decoding="async" class="alignnone wp-image-2015443 ezlazyloaded" src="images/6.webp" alt="" width="56" height="47" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/02/AC-INFINITY-AC-WFS12-Wall-And-Floor-Circulator-Fan-warning.jpg?ezimgfmt=rs:56x47/rscb1/ng:webp/ngcb1" />WARNING</strong><br />
This mark warns of death or serious injury.<br />
<strong><img decoding="async" class="alignnone wp-image-2015443 ezlazyloaded" src="images/6.webp" alt="" width="56" height="47" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/02/AC-INFINITY-AC-WFS12-Wall-And-Floor-Circulator-Fan-warning.jpg?ezimgfmt=rs:56x47/rscb1/ng:webp/ngcb1" />CAUTION</strong><br />
This mark warns of injury or damage to property.<br />
This mark denotes an action that is PROHIBITED.<br />
This mark denotes an action that is COMPULSORY.</p>
<p><strong><img decoding="async" class="alignnone wp-image-2015443 ezlazyloaded" src="images/6.webp" alt="" width="56" height="47" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/02/AC-INFINITY-AC-WFS12-Wall-And-Floor-Circulator-Fan-warning.jpg?ezimgfmt=rs:56x47/rscb1/ng:webp/ngcb1" />WARNING</strong></p>
<ul>
<li><img decoding="async" class="alignnone wp-image-2012555 ezlazyloaded" src="images/7.webp" alt="important icon" width="49" height="47" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/02/important-icon.jpg?ezimgfmt=rs:49x46/rscb1/ng:webp/ngcb1" />This product contains no user-serviceable parts.<br />
Always consult authorized service personnel for repair, installation, and relocation of this product.<br />
Improper installation or handling will cause leakage, electric shock, or ﬁ re.</li>
<li>In the event of a malfunction such as a burning smell, immediately stop the operation of the air conditioner, and disconnect all the power supply by turning off the electrical breaker or disconnecting the power plug.<br />
Then consult authorized service personnel.</li>
<li>Take care not to damage the power supply cable.<br />
If it is damaged, it should be replaced only by authorized service personnel in order to avoid a hazard.</li>
<li>If a refrigerant leakage is suspected, all naked ﬂames shall be removed or extinguished, and consult authorized service personnel.</li>
<li>In the event of a thunderstorm or any prior sign of a lightning strike, turn off the air conditioner via the remote controller, and refrain from touching the product or the power source to prevent any electrical hazards.</li>
<li>This product is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge unless they have been given supervision or instruction concerning the use of this product by a person responsible for their safety. Children should be supervised to ensure that they do not play with this product.</li>
<li>Dispose of the packing materials safely. Tear and dispose of the plastic packing bags so that children cannot play with them. There is a danger of suffocation if children play with the original plastic bags.</li>
<li><strong><img decoding="async" class="alignnone wp-image-3801712 ezlazyloaded" src="images/8.webp" alt="Flysky FS VK G4P Digital Proportional Radio Control System - icon 1" width="51" height="44" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/07/Flysky-FS-VK-G4P-Digital-Proportional-Radio-Control-System-icon-1.jpg?ezimgfmt=rs:51x44/rscb1/ng:webp/ngcb1" /></strong>Do not start or stop the operation of this product by inserting or pulling out the power plug, or by turning on or off the circuit breaker.</li>
<li>Do not use ﬂammable gases near this product.</li>
<li>Do not expose yourself directly to the cooling airﬂow for many hours.</li>
<li>Do not insert your ﬁngers or any other objects into the outlet port or inlet port.</li>
<li>Do not operate with wet hands.</li>
</ul>
<p><strong><img decoding="async" class="alignnone wp-image-2015443 ezlazyloaded" src="images/6.webp" alt="" width="56" height="47" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/02/AC-INFINITY-AC-WFS12-Wall-And-Floor-Circulator-Fan-warning.jpg?ezimgfmt=rs:56x47/rscb1/ng:webp/ngcb1" />CAUTION</strong></p>
<ul>
<li><strong><img decoding="async" class="alignnone wp-image-2012555 ezlazyloaded" src="images/7.webp" alt="important icon" width="49" height="47" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/02/important-icon.jpg?ezimgfmt=rs:49x46/rscb1/ng:webp/ngcb1" /></strong>Provide occasional ventilation during use.</li>
<li>Always operate this product with air ﬁ lters installed.</li>
<li>Ensure that any electronic equipment is at least 40 in (1 m) away from this product.</li>
<li>Disconnect all the power supply when not using this product for extended periods.</li>
<li>After a long period of use, ensure to get the mounting of the indoor unit checked to prevent this product from falling down.</li>
<li>The airﬂ ow direction and the room temperature should be carefully considered when you use this product in a room with infants, children, elderly or sick persons.</li>
<li>Keep the surroundings of the outdoor unit clean and tidy, and do not place items around it. Any objects blocking or entering from the outlet ports may cause product malfunction.</li>
<li><strong><img decoding="async" class="alignnone wp-image-2012555 ezlazyloaded" src="images/7.webp" alt="important icon" width="49" height="47" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/02/important-icon.jpg?ezimgfmt=rs:49x46/rscb1/ng:webp/ngcb1" /></strong>Do not direct the airﬂ ow at ﬁreplaces or heating apparatus.</li>
<li>Do not block or cover the intake grille and the outlet port.</li>
<li>Do not apply any heavy pressure to the radiator ﬁns.</li>
<li>Do not climb on, place objects on, or hang objects from this product.</li>
<li>Do not place any other electrical products or household belongings under this product. Dripping condensation from this product might get them wet, and may cause damage or malfunction of your property.</li>
<li>Do not expose this product directly to water.</li>
<li>Do not use this product for the preservation of food, plants, animals, precision equipment, artwork, or other objects.<br />
This may cause quality deterioration of those items.</li>
<li>Do not expose animals or plants to the direct airﬂ ow.</li>
<li>Do not drink the drainage from the air conditioner.</li>
<li>Do not pull the power supply cable.</li>
<li>Do not touch the aluminum ﬁ ns of the heat exchanger built in this product to avoid personal injury when you maintain the unit.</li>
<li>Do not stand on unstable steps when operating or cleaning this product. It may overturn and can cause injury.</li>
</ul>
<h4>PREPARATION</h4>
<p><strong><img decoding="async" class="alignnone wp-image-2015443 ezlazyloaded" src="images/6.webp" alt="" width="56" height="47" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/02/AC-INFINITY-AC-WFS12-Wall-And-Floor-Circulator-Fan-warning.jpg?ezimgfmt=rs:56x47/rscb1/ng:webp/ngcb1" />WARNING</strong></p>
<ul>
<li><strong><img decoding="async" class="alignnone wp-image-2012555 ezlazyloaded" src="images/7.webp" alt="important icon" width="49" height="47" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/02/important-icon.jpg?ezimgfmt=rs:49x46/rscb1/ng:webp/ngcb1" /></strong>Take care to prevent infants and young children from accidentally swallowing the batteries.</li>
</ul>
<p><strong><img decoding="async" class="alignnone wp-image-2015443 ezlazyloaded" src="images/6.webp" alt="" width="56" height="47" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/02/AC-INFINITY-AC-WFS12-Wall-And-Floor-Circulator-Fan-warning.jpg?ezimgfmt=rs:56x47/rscb1/ng:webp/ngcb1" />CAUTION</strong></p>
<ul>
<li><strong><img decoding="async" class="alignnone wp-image-2012555 ezlazyloaded" src="images/7.webp" alt="important icon" width="49" height="47" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/02/important-icon.jpg?ezimgfmt=rs:49x46/rscb1/ng:webp/ngcb1" /></strong>If leaking battery ﬂuid comes in contact with your skin, eyes, or mouth, immediately rinse with plenty of clean water, and consult your physician.</li>
<li>Exhausted batteries must be removed immediately, and be disposed of according to the local laws and regulations of your region.</li>
<li><strong><img decoding="async" class="alignnone wp-image-3801712 ezlazyloaded" src="images/8.webp" alt="Flysky FS VK G4P Digital Proportional Radio Control System - icon 1" width="51" height="44" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/07/Flysky-FS-VK-G4P-Digital-Proportional-Radio-Control-System-icon-1.jpg?ezimgfmt=rs:51x44/rscb1/ng:webp/ngcb1" /></strong>Do not attempt to recharge dry batteries.</li>
<li>Do not use dry batteries that have been recharged.</li>
</ul>
<p><strong>Indoor unit accessories </strong></p>
<p>Check that the following accessories are included.</p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/06/FUJITSU-9387602227-Air-Conditioner-accessories.webp" /></p>
<p><strong>Remote controller holder installation </strong></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/06/FUJITSU-9387602227-Air-Conditioner-installation.webp" /></p>
<h4>NAME OF PARTS</h4>
<p><strong><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/06/AC-INFINITY-AC-WFS12-Wall-And-Floor-Circulator-Fan-warning-1.webp" /></strong><strong>CAUTION</strong></p>
<p><strong><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/06/important-icon-1.webp" /></strong>For appropriate signal transmission between the remote controller and the indoor unit, keep the signal receiver away from the following items:</p>
<ul>
<li>Direct sunlight or other strong lights</li>
<li>Flat-panel television screen<br />
In rooms with instantaneous ﬂ fluorescent lights, such as inverter-type ones, the signal may not be transmitted properly. In such a case, consult the store of purchase.</li>
</ul>
<p><strong>3.1. Remote controller</strong><br />
<strong>CAUTION</strong></p>
<ul>
<li><strong><img decoding="async" class="alignnone wp-image-2012555 ezlazyloaded" src="images/7.webp" alt="important icon" width="49" height="47" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/02/important-icon.jpg?ezimgfmt=rs:49x46/rscb1/ng:webp/ngcb1" /></strong>To prevent malfunction or damage of the remote controller:</li>
<li>Place remote controller at where will not be exposed to direct sunlight or excessive heat.</li>
<li>Remove batteries if the product is not going to be used for an extended period.</li>
<li>Obstacles such as a curtain or wall between the remote controller and the indoor unit may affect the appropriate signal transmission.</li>
<li><strong><img decoding="async" class="alignnone wp-image-3801712 ezlazyloaded" src="images/8.webp" alt="Flysky FS VK G4P Digital Proportional Radio Control System - icon 1" width="51" height="44" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/07/Flysky-FS-VK-G4P-Digital-Proportional-Radio-Control-System-icon-1.jpg?ezimgfmt=rs:51x44/rscb1/ng:webp/ngcb1" /></strong>Do not apply strong shocks to the remote controller.</li>
<li>Do not pour water on the remote controller.</li>
</ul>
<p>When you use the optional remote controller, the appearance and the operation procedure may differ.<br />
For details, refer to the operation manual of each remote controller.</p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/06/FUJITSU-9387602227-Air-Conditioner-remot.webp" /></p>
<p><strong>3.2. Inserting batteries</strong></p>
<p>Battery type: R03/LR03/AAA × 2<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/06/FUJITSU-9387602227-Air-Conditioner-Battery.webp" /></p>
<p>1~3. Put batteries as shown in the ﬁ gure above.<br />
Press <img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/06/FUJITSU-9387602227-Air-Conditioner-icon-33.webp" />as shown in the ﬁ gure above.<br />
<strong>NOTES:</strong></p>
<ul>
<li>Use speciﬁ ed types of batteries only.</li>
<li>Do not mix different types of new and used batteries together.</li>
<li>Batteries can be used for about 1 year in ordinary use.</li>
<li>If the remote control range noticeably shortens, replace the batteries, and presses<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/06/FUJITSU-9387602227-Air-Conditioner-icon-33-1.webp" /> shown in the ﬁ gure above.</li>
</ul>
<p><strong>3.3. Indoor unit </strong></p>
<p><img loading="lazy" decoding="async" class="alignnone size-full wp-image-3843125 ezlazyloaded" src="images/17.webp" alt="FUJITSU 9387602227 Air Conditioner - icon 1" width="40" height="29" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/07/FUJITSU-9387602227-Air-Conditioner-icon-1.jpg?ezimgfmt=rs:40x29/rscb1/ng:webp/ngcb1" />: The instruction is related to the wireless LAN control (optional).<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/06/FUJITSU-9387602227-Air-Conditioner-LAN-control.webp" /></p>
<ol>
<li>Before starting the operation, make sure that the intake grille is closed completely. Incomplete closing may affect the proper function or performance of the product.</li>
<li>Indicator lamps light in the following conditions.</li>
</ol>
<table width="961">
<tbody>
<tr>
<td width="70"></td>
<td width="149">Name</td>
<td width="131">Color</td>
<td width="347">Operation or condition</td>
</tr>
<tr>
<td width="70"><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/06/FUJITSU-9387602227-Air-Conditioner-icon-2.webp" /></td>
<td width="149">Operation</td>
<td width="131">Green</td>
<td width="347">Normal operation</td>
</tr>
<tr>
<td width="70"><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/06/Stiebel-Eltron-CON-5-Premium-Wall-mounted-convector-heater-icon-5.webp" /></td>
<td width="149">Timer</td>
<td width="131">Orange</td>
<td width="347">Timer operation</td>
</tr>
<tr>
<td width="70"><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/06/FUJITSU-9387602227-Air-Conditioner-icon-3.webp" /></td>
<td width="149">Economy</td>
<td width="131">Green</td>
<td width="347">Economy operation<br />
Minimum Heat operation (optional)</td>
</tr>
<tr>
<td width="70"><img loading="lazy" decoding="async" class="alignnone size-full wp-image-3843125 aligncenter ezlazyloaded" src="images/17.webp" alt="FUJITSU 9387602227 Air Conditioner - icon 1" width="40" height="29" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/07/FUJITSU-9387602227-Air-Conditioner-icon-1.jpg?ezimgfmt=rs:40x29/rscb1/ng:webp/ngcb1" /></td>
<td width="149">WLAN</td>
<td width="131">Orange</td>
<td width="347">Wireless LAN control is active.</td>
</tr>
</tbody>
</table>
<h4>BASIC OPERATIONS</h4>
<p><strong>3 steps to start operation</strong></p>
<ol>
<li>Press<img loading="lazy" decoding="async" class="alignnone size-full-size wp-image-3459657 ezlazyloaded" src="images/22.webp" alt="MIXX OX2 MOTH On Ear Wireless Headphones - icon 1" width="31" height="33" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/06/MIXX-OX2-MOTH-On-Ear-Wireless-Headphones-icon-1.jpg?ezimgfmt=rs:31x33/rscb1/ng:webp/ngcb1" />/I to start or stop the operation.</li>
<li>Press <strong><code>MODE</code></strong>to select the operation mode.<br />
The operation mode changes as follows.<br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/06/FUJITSU-9387602227-Air-Conditioner-operation.webp" /></li>
<li>Press<img loading="lazy" decoding="async" class="alignnone size-full wp-image-3843137 ezlazyloaded" src="images/24.webp" alt="FUJITSU 9387602227 Air Conditioner - icon 8" width="71" height="25" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/07/FUJITSU-9387602227-Air-Conditioner-icon-8.jpg?ezimgfmt=rs:71x25/rscb1/ng:webp/ngcb1" /> to set the desired temperature. The temperature changes by 1 °F (0.5 °C) increments.</li>
</ol>
<table width="663">
<tbody>
<tr>
<td colspan="2" width="547"><strong>Temperature setting range</strong></td>
</tr>
<tr>
<td>Auto/Cooling/Dry</td>
<td>64-88 °F (18.0-30.0 °C)</td>
</tr>
<tr>
<td>Heating</td>
<td>60-88 °F (16.0-30.0 °C)</td>
</tr>
</tbody>
</table>
<p><strong>NOTES:</strong></p>
<ul>
<li>In the Cooling or Dry mode, set the temperature lower than the current room temperature.</li>
<li>In the Heating mode,<br />
– set the temperature higher than the current room temperature.<br />
– at the beginning of the operation, the indoor unit fan rotates at very low speed for 3-5 minutes.<br />
– the Automatic defrosting operation overrides the Heating operation when necessary.</li>
<li>In the Fan mode, temperature control is not available.</li>
</ul>
<h4><strong>■ Temperature unit switching</strong></h4>
<p><strong>5.1. Fan speed setting<br />
</strong><img loading="lazy" decoding="async" class="alignnone size-full wp-image-3843128 ezlazyloaded" src="images/26.webp" alt="FUJITSU 9387602227 Air Conditioner - icon 4" width="39" height="22" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/07/FUJITSU-9387602227-Air-Conditioner-icon-4.jpg?ezimgfmt=rs:39x22/rscb1/ng:webp/ngcb1" />Press <strong>FAN SPEED </strong>to control the fan speed.<br />
The fan speed changes as follows.<br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/06/FUJITSU-9387602227-Air-Conditioner-Sleep-3.webp" />When <strong>AUTO </strong>is selected, the fan speed depends on the operating condition.<br />
NOTE: In the Dry mode, the fan speed is ﬁxed to <strong>AUTO.<br />
</strong></p>
<p><strong>5.2. Airﬂ ow direction setting<br />
</strong>For details of the airﬂ ow ranges, refer to “Airﬂ ow direction range”.</p>
<ul>
<li>Up/down airﬂ ow direction setting<br />
<img loading="lazy" decoding="async" class="alignnone size-full wp-image-3843128 ezlazyloaded" src="images/26.webp" alt="FUJITSU 9387602227 Air Conditioner - icon 4" width="39" height="22" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/07/FUJITSU-9387602227-Air-Conditioner-icon-4.jpg?ezimgfmt=rs:39x22/rscb1/ng:webp/ngcb1" />Press<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/06/FUJITSU-9387602227-Air-Conditioner-icon-5.webp" /> to adjust the up/down airﬂ ow direction.</li>
<li>Left/right airﬂ ow direction setting<br />
<img loading="lazy" decoding="async" class="alignnone size-full wp-image-3843128 ezlazyloaded" src="images/26.webp" alt="FUJITSU 9387602227 Air Conditioner - icon 4" width="39" height="22" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/07/FUJITSU-9387602227-Air-Conditioner-icon-4.jpg?ezimgfmt=rs:39x22/rscb1/ng:webp/ngcb1" />Press <img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/06/FUJITSU-9387602227-Air-Conditioner-icon-6.webp" />to adjust the left/right airﬂ ow direction.</li>
<li>Swing operation setting<br />
<img loading="lazy" decoding="async" class="alignnone size-full wp-image-3843128 ezlazyloaded" src="images/26.webp" alt="FUJITSU 9387602227 Air Conditioner - icon 4" width="39" height="22" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/07/FUJITSU-9387602227-Air-Conditioner-icon-4.jpg?ezimgfmt=rs:39x22/rscb1/ng:webp/ngcb1" />Press <strong>SWING </strong>to select the Swing operation.</li>
</ul>
<p>The Swing operation changes as follows. <img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/06/FUJITSU-9387602227-Air-Conditioner-operation-2.webp" /></p>
<p><strong>NOTE:</strong> The Swing operation may stop temporarily when the indoor unit fan is rotating at very low speed or is stopped.</p>
<p><strong>Airﬂ ow direction range</strong><br />
<strong>Up/down airﬂ ow direction </strong><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/06/FUJITSU-9387602227-Air-Conditioner-Airfl-ow.webp" /></p>
<ul>
<li>The Swing operation range depends on the airﬂ ow direction set before the Swing operation.</li>
</ul>
<p><strong>NOTES:</strong></p>
<ul>
<li>Do not adjust the horizontal louvers by hand.</li>
<li>In the Auto or Heating mode, the airﬂ ow direction stays at position 1 for a while from the start of the operation.</li>
<li>In the Cooling or Dry mode, position 1-3 is recommended to prevent condensation drips from damaging your property. If position 4-6 keeps for 30 minutes or more in these modes, the airﬂ ow direction changes to position 3 automatically.</li>
<li>When using the mobile app (an optional WLAN adapter is necessary), the up/down airﬂ ow can be selected from 4 positions.</li>
</ul>
<p><strong>Left/right airﬂ ow direction</strong></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/06/FUJITSU-9387602227-Air-Conditioner-direction.webp" /></p>
<p><strong>NOTE:</strong> In the Auto mode operation, you cannot change the airﬂow direction for a while from the start of the operation.</p>
<h4>TIMER OPERATIONS</h4>
<p><strong>NOTE:</strong> When [<strong><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/06/Stiebel-Eltron-CON-5-Premium-Wall-mounted-convector-heater-icon-5-1.webp" /></strong> ] indicator on the indoor unit blinks, set the clock and timer again. This blinking shows that the internal clock goes wrong due to an interruption of the power supply.</p>
<p><strong>■ Timer setting procedure</strong></p>
<ol>
<li>Press<strong><img loading="lazy" decoding="async" class="alignnone wp-image-3547442 ezlazyloaded" src="images/34.webp" alt="Stiebel Eltron CON 5 Premium Wall mounted convector heater - icon 5" width="38" height="32" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/06/Stiebel-Eltron-CON-5-Premium-Wall-mounted-convector-heater-icon-5.jpg?ezimgfmt=rs:38x32/rscb1/ng:webp/ngcb1" /></strong>to choose timer operation. Each time you press the button, the timer operation will change as follows:<br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/06/FUJITSU-9387602227-Air-Conditioner-Timer.webp" /></p>
<table width="890">
<tbody>
<tr>
<td width="123">Off timer</td>
<td width="267">Stops the operation at your desired time.</td>
</tr>
<tr>
<td width="123">On timer</td>
<td width="267">Starts the operation at your desired time.</td>
</tr>
<tr>
<td width="123">Program timer</td>
<td width="267">Operates as the combination of the On timer and Off timer.</td>
</tr>
<tr>
<td width="123">Cancel</td>
<td width="267">Deactivate the timer.</td>
</tr>
</tbody>
</table>
<p>• If you choose “Cancel”, the display returns to the operation display.<br />
• To set a sleep timer, press<strong><img loading="lazy" decoding="async" class="alignnone wp-image-3547442 ezlazyloaded" src="images/34.webp" alt="Stiebel Eltron CON 5 Premium Wall mounted convector heater - icon 5" width="38" height="32" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/06/Stiebel-Eltron-CON-5-Premium-Wall-mounted-convector-heater-icon-5.jpg?ezimgfmt=rs:38x32/rscb1/ng:webp/ngcb1" /> SLEEP</strong>. (Refer to “6.3. Sleep timer”.)</li>
<li>Set each timer operation.<br />
For details, refer to the following instructions of each timer setting.</li>
</ol>
<p><strong>6.1. On timer or Off timer</strong></p>
<ol>
<li>Select On timer or Off timer in step 1 of “Timer setting procedure.”</li>
<li>Each time you press<img loading="lazy" decoding="async" class="alignnone size-full wp-image-3843137 ezlazyloaded" src="images/24.webp" alt="FUJITSU 9387602227 Air Conditioner - icon 8" width="71" height="25" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/07/FUJITSU-9387602227-Air-Conditioner-icon-8.jpg?ezimgfmt=rs:71x25/rscb1/ng:webp/ngcb1" />, the time changes as follows:</li>
</ol>
<ul>
<li><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/06/FUJITSU-9387602227-Air-Conditioner-Timer-2.webp" />When you use the On timer, set the time while the indicator on the remote controller display is blinking.</li>
<li>When you use the Off timer, set the time while the indicator on the remote controller display is blinking.</li>
<li>To deactivate the On/Off timer, select Cancel in step 1 of “Timer setting procedure” while [ <strong><img loading="lazy" decoding="async" class="alignnone wp-image-3547442 ezlazyloaded" src="images/34.webp" alt="Stiebel Eltron CON 5 Premium Wall mounted convector heater - icon 5" width="38" height="32" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/06/Stiebel-Eltron-CON-5-Premium-Wall-mounted-convector-heater-icon-5.jpg?ezimgfmt=rs:38x32/rscb1/ng:webp/ngcb1" /> ON</strong>] or [ <strong><img loading="lazy" decoding="async" class="alignnone wp-image-3547442 ezlazyloaded" src="images/34.webp" alt="Stiebel Eltron CON 5 Premium Wall mounted convector heater - icon 5" width="38" height="32" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/06/Stiebel-Eltron-CON-5-Premium-Wall-mounted-convector-heater-icon-5.jpg?ezimgfmt=rs:38x32/rscb1/ng:webp/ngcb1" />OFF</strong>] is shown on the remote controller display. The indicator will disappear.</li>
</ul>
<p><strong>NOTE:</strong> If you set the Sleep timer after setting the On/Off timer, the On/Off timer is canceled.</p>
<p><strong>6.2. Program timer</strong></p>
<ol>
<li>Set On Timer and Off timer. (Refer to “6.1. On timer or Off timer”.)</li>
<li>Select Program timer in step 1 of “Timer setting procedure”.<br />
After the time set by the earlier timer passed, the timer set later will begin the counting down.<br />
The order of the timer operation is displayed as follows:</li>
</ol>
<table width="957">
<tbody>
<tr>
<td width="236">Timer</td>
<td width="311">The indicator on the remote controller display</td>
</tr>
<tr>
<td>Off→On timer</td>
<td><strong><img loading="lazy" decoding="async" class="alignnone wp-image-3547442 ezlazyloaded" src="images/34.webp" alt="Stiebel Eltron CON 5 Premium Wall mounted convector heater - icon 5" width="38" height="32" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/06/Stiebel-Eltron-CON-5-Premium-Wall-mounted-convector-heater-icon-5.jpg?ezimgfmt=rs:38x32/rscb1/ng:webp/ngcb1" /> ON ▲ OFF</strong></td>
</tr>
<tr>
<td>On →Off timer</td>
<td><strong><img loading="lazy" decoding="async" class="alignnone wp-image-3547442 ezlazyloaded" src="images/34.webp" alt="Stiebel Eltron CON 5 Premium Wall mounted convector heater - icon 5" width="38" height="32" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/06/Stiebel-Eltron-CON-5-Premium-Wall-mounted-convector-heater-icon-5.jpg?ezimgfmt=rs:38x32/rscb1/ng:webp/ngcb1" />ON ▼ OFF</strong></td>
</tr>
</tbody>
</table>
<p><strong>NOTE:</strong> If you set the Sleep timer after setting the Program timer, the Program timer is canceled.</p>
<p><strong>6.3. Sleep timer</strong><br />
The Sleep timer supports your comfortable sleep by moderating the air conditioner operation gradually.</p>
<p><img loading="lazy" decoding="async" class="alignnone size-full wp-image-3843128 ezlazyloaded" src="images/26.webp" alt="FUJITSU 9387602227 Air Conditioner - icon 4" width="39" height="22" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/07/FUJITSU-9387602227-Air-Conditioner-icon-4.jpg?ezimgfmt=rs:39x22/rscb1/ng:webp/ngcb1" />Press <strong><img loading="lazy" decoding="async" class="alignnone wp-image-3547442 ezlazyloaded" src="images/34.webp" alt="Stiebel Eltron CON 5 Premium Wall mounted convector heater - icon 5" width="38" height="32" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/06/Stiebel-Eltron-CON-5-Premium-Wall-mounted-convector-heater-icon-5.jpg?ezimgfmt=rs:38x32/rscb1/ng:webp/ngcb1" />SLEEP</strong>.<br />
Each time you press the button, the time changes as follows:<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/06/FUJITSU-9387602227-Air-Conditioner-Sleep.webp" /></p>
<p>To repeat the timer, press the button when<strong><img loading="lazy" decoding="async" class="alignnone wp-image-3547442 ezlazyloaded" src="images/34.webp" alt="Stiebel Eltron CON 5 Premium Wall mounted convector heater - icon 5" width="38" height="32" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/06/Stiebel-Eltron-CON-5-Premium-Wall-mounted-convector-heater-icon-5.jpg?ezimgfmt=rs:38x32/rscb1/ng:webp/ngcb1" /> the SLEEP </strong>indicator is not displayed.<br />
During the Sleep timer operation, the setting temperature changes as the following ﬁ gure.<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/06/FUJITSU-9387602227-Air-Conditioner-Sleep-2.webp" /></p>
<p>After the set time has elapsed, the air conditioner operation turns off.</p>
<h4>ENERGY SAVING OPERATION</h4>
<p><strong>7.1. Economy operation</strong><br />
It saves more electricity than other operation modes by changing the set temperature to a moderate setting.<br />
<img loading="lazy" decoding="async" class="alignnone size-full wp-image-3843128 ezlazyloaded" src="images/26.webp" alt="FUJITSU 9387602227 Air Conditioner - icon 4" width="39" height="22" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/07/FUJITSU-9387602227-Air-Conditioner-icon-4.jpg?ezimgfmt=rs:39x22/rscb1/ng:webp/ngcb1" />Press<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/06/FUJITSU-9387602227-Air-Conditioner-icon-3-1.webp" /> to activate/deactivate the Economy operation.<br />
[ <img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/06/FUJITSU-9387602227-Air-Conditioner-icon-3-2.webp" />] indicator on the indoor unit will turn on.</p>
<table width="903">
<tbody>
<tr>
<td width="236"><strong>Operation mode</strong></td>
<td width="311"><strong>Room temperature</strong></td>
</tr>
<tr>
<td>Cooling/Dry</td>
<td>Few degrees higher than the set temperature</td>
</tr>
<tr>
<td>Heating</td>
<td>Few degrees lower than the set temperature</td>
</tr>
</tbody>
</table>
<p><strong>NOTES:</strong></p>
<ul>
<li>In the Cooling, Heating, or Dry mode, the maximum output of this operation is approximately 70 % of the usual operation.</li>
<li>This operation cannot be performed during the temperature monitoring by the Auto mode.</li>
</ul>
<p><strong>7.2. Fan control for energy saving </strong></p>
<p>In the Cooling operation, when the room temperature reaches the set temperature, the indoor unit fan rotates intermittently to save power. (This function is deactivated at the  time of purchase.)<br />
To change the setting, use the following steps;<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/06/FUJITSU-9387602227-Air-Conditioner-Fan.webp" /></p>
<ol>
<li>Press<strong><img loading="lazy" decoding="async" class="alignnone size-full-size wp-image-3459657 ezlazyloaded" src="images/22.webp" alt="MIXX OX2 MOTH On Ear Wireless Headphones - icon 1" width="31" height="33" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/06/MIXX-OX2-MOTH-On-Ear-Wireless-Headphones-icon-1.jpg?ezimgfmt=rs:31x33/rscb1/ng:webp/ngcb1" /></strong> until the indicators on the remote controller turn off.</li>
<li>Press and hold <strong>FAN SPEED</strong> for more than 5 seconds.<br />
The <img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/06/FUJITSU-9387602227-Air-Conditioner-icon-7.webp" />and the current status will appear.<br />
<strong>ON</strong>: Activated<br />
<strong>OFF</strong>: Deactivated</li>
<li>Press<img loading="lazy" decoding="async" class="alignnone size-full wp-image-3843137 ezlazyloaded" src="images/24.webp" alt="FUJITSU 9387602227 Air Conditioner - icon 8" width="71" height="25" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/07/FUJITSU-9387602227-Air-Conditioner-icon-8.jpg?ezimgfmt=rs:71x25/rscb1/ng:webp/ngcb1" /> to switch the status.</li>
<li>Press<strong><img loading="lazy" decoding="async" class="alignnone size-full-size wp-image-3459657 ezlazyloaded" src="images/22.webp" alt="MIXX OX2 MOTH On Ear Wireless Headphones - icon 1" width="31" height="33" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/06/MIXX-OX2-MOTH-On-Ear-Wireless-Headphones-icon-1.jpg?ezimgfmt=rs:31x33/rscb1/ng:webp/ngcb1" /></strong> to send the set to the indoor unit.<br />
The display will return to the original screen.</li>
</ol>
<p><strong>NOTE:</strong> If you do not press any buttons for 30 seconds after are displayed, will turn off. In this case, repeat the setting from step 2.</p>
<h4>OTHER OPERATIONS</h4>
<p><strong>8.1. Powerful operation</strong><br />
In the Powerful operation, the air conditioner will operate at maximum power and strong airﬂ ow to cool down or warm up the room quickly.</p>
<p><img loading="lazy" decoding="async" class="alignnone size-full wp-image-3843128 ezlazyloaded" src="images/26.webp" alt="FUJITSU 9387602227 Air Conditioner - icon 4" width="39" height="22" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/07/FUJITSU-9387602227-Air-Conditioner-icon-4.jpg?ezimgfmt=rs:39x22/rscb1/ng:webp/ngcb1" />Press POWERFULL to activate/deactivate the Powerful operation.<br />
When activated, the indoor unit will emit 2 short beeps.<br />
When deactivated, the indoor unit will emit 1 short beep.<br />
The Powerful operation will be turned off automatically in the following situations:</p>
<ul>
<li>The Powerful operation runs for a certain amount of time and the<br />
room temperature reaches the set temperature in the Cooling, Dry,<br />
or Heating mode.</li>
<li>20 minutes after the Powerful operation has started.</li>
</ul>
<p><strong>NOTES:</strong></p>
<ul>
<li>The airﬂ ow direction and the fan speed are controlled automatically.</li>
<li>The Powerful operation cannot be performed simultaneously with the Economy operation.</li>
<li>If the wired remote controller (optional) is connected, this function is restricted.</li>
</ul>
<p><strong>8.2. Minimum heat operation (optional)</strong></p>
<p><strong>NOTE:</strong></p>
<ul>
<li>This function is available only by the wireless LAN control (optional).<br />
Minimum heat operation maintains the room temperature at 50 °F (10 °C) so as to prevent the room temperature to drop too low.<br />
– When activated, [ <img loading="lazy" decoding="async" class="alignnone wp-image-3843127 ezlazyloaded" src="images/43.webp" alt="FUJITSU 9387602227 Air Conditioner - icon 3" width="32" height="28" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/07/FUJITSU-9387602227-Air-Conditioner-icon-3.jpg?ezimgfmt=rs:32x28/rscb1/ng:webp/ngcb1" />] indicator on the indoor unit will turn on.<br />
– When deactivated, [<img loading="lazy" decoding="async" class="alignnone wp-image-3843127 ezlazyloaded" src="images/43.webp" alt="FUJITSU 9387602227 Air Conditioner - icon 3" width="32" height="28" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/07/FUJITSU-9387602227-Air-Conditioner-icon-3.jpg?ezimgfmt=rs:32x28/rscb1/ng:webp/ngcb1" /> ] indicator will turn off.</li>
</ul>
<p><strong>NOTES:</strong></p>
<ul>
<li>During the Minimum heat operation, only the up/down and left/right airﬂ ow direction settings are valid.</li>
<li>When the room temperature is warm enough, This operation will not be performed.</li>
</ul>
<h4>SETTINGS ON INSTALLATION</h4>
<p><strong>9.1. Remote controller custom code setting</strong><br />
By setting the custom code of the indoor unit and remote controller, you can specify the air conditioner which the remote controller controls.<br />
When two or more air conditioners are in the room and you wish to operate them separately, set the custom code (4 selections possible).<br />
<strong>NOTE:</strong> If custom codes is different between the indoor unit and the remote controller, the indoor unit cannot receive a signal from the remote controller.</p>
<p><strong>How to set the remote controller custom code</strong></p>
<ol>
<li>Press<strong><img loading="lazy" decoding="async" class="alignnone size-full-size wp-image-3459657 ezlazyloaded" src="images/22.webp" alt="MIXX OX2 MOTH On Ear Wireless Headphones - icon 1" width="31" height="33" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/06/MIXX-OX2-MOTH-On-Ear-Wireless-Headphones-icon-1.jpg?ezimgfmt=rs:31x33/rscb1/ng:webp/ngcb1" /></strong>until the indicators on the remote controller turn off.</li>
<li>Press down <strong>MODE </strong>for more than 5 seconds.<br />
The current custom code will be displayed (initially set to A).</li>
<li>Press<img loading="lazy" decoding="async" class="alignnone size-full wp-image-3843137 ezlazyloaded" src="images/24.webp" alt="FUJITSU 9387602227 Air Conditioner - icon 8" width="71" height="25" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/07/FUJITSU-9387602227-Air-Conditioner-icon-8.jpg?ezimgfmt=rs:71x25/rscb1/ng:webp/ngcb1" /> to change the custom code between <img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/06/FUJITSU-9387602227-Air-Conditioner-operation-9.webp" /><br />
* Match the custom code on the display to the air conditioner custom code.</li>
<li>Press <strong>MODE </strong>again.<br />
The custom code will be set.<br />
The display will return to the original display.<br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/06/FUJITSU-9387602227-Air-Conditioner-controller.webp" /></li>
</ol>
<ul>
<li>To change the air conditioner custom code, contact authorized service personnel (initially set to A).</li>
<li>If you do not press any buttons for 30 seconds after the custom code is displayed, the displayed custom code is set and the display returns to the original display.</li>
<li>Depending on the remote controller, the custom code may return to A when replacing the batteries. In this case, reset the custom code as necessary. If you do not know the air conditioner custom code, try each code until you ﬁnd the code which operates the air conditioner.</li>
</ul>
<h4>CLEANING AND CARE</h4>
<p><strong><img decoding="async" class="alignnone wp-image-2015443 ezlazyloaded" src="images/6.webp" alt="" width="56" height="47" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/02/AC-INFINITY-AC-WFS12-Wall-And-Floor-Circulator-Fan-warning.jpg?ezimgfmt=rs:56x47/rscb1/ng:webp/ngcb1" />CAUTION</strong></p>
<ul>
<li><strong><img decoding="async" class="alignnone wp-image-2012555 ezlazyloaded" src="images/7.webp" alt="important icon" width="49" height="47" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/02/important-icon.jpg?ezimgfmt=rs:49x46/rscb1/ng:webp/ngcb1" /></strong>Before cleaning this product, be sure to turn it off and disconnect all the power supply.</li>
<li>Before starting the operation, make sure that the intake grille has been shut completely. Incomplete closing of the intake grille might have an effect on the proper working or performance of the air conditioner.</li>
<li>If the ﬁ lter cleaning involves high-place work, consult the authorized service personnel.</li>
<li><strong><img decoding="async" class="alignnone wp-image-3801712 ezlazyloaded" src="images/8.webp" alt="Flysky FS VK G4P Digital Proportional Radio Control System - icon 1" width="51" height="44" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/07/Flysky-FS-VK-G4P-Digital-Proportional-Radio-Control-System-icon-1.jpg?ezimgfmt=rs:51x44/rscb1/ng:webp/ngcb1" /></strong>Do not touch the aluminum ﬁ ns of the heat exchanger built-in in the indoor unit to avoid personal injury when you maintain the unit.</li>
<li>Do not expose the indoor unit to liquid insecticides or hair sprays.</li>
<li>Do not stand on slippery, uneven, or unstable surfaces when you maintain the unit.<br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/06/FUJITSU-9387602227-Air-Conditioner-CLEANING.webp" /></li>
</ul>
<p>The frequency of the cleaning is shown in the following table.</p>
<table width="931">
<tbody>
<tr>
<td colspan="2" width="372"><strong>What to do</strong></td>
<td width="150"><strong>Frequency</strong></td>
</tr>
<tr>
<td width="280">Indoor unit body</td>
<td width="92">Cleaning</td>
<td width="150">When you notice</td>
</tr>
<tr>
<td width="280">Air filter</td>
<td width="92">Cleaning</td>
<td width="150">Every 2 weeks</td>
</tr>
<tr>
<td width="280">Apple-catechin filter (UTR-FA16)<br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/06/FUJITSU-9387602227-Air-Conditioner-icon-9.webp" />(White)</td>
<td width="92">Replacing</td>
<td width="150">Every 3 months</td>
</tr>
<tr>
<td rowspan="2" width="280">Ion deodorization filter (UTR-FA16-2)<br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/06/FUJITSU-9387602227-Air-Conditioner-icon-10.webp" />(Light blue)</td>
<td width="92">Cleaning</td>
<td width="150">Every 3 months</td>
</tr>
<tr>
<td width="92">Replacing</td>
<td width="150">Every 3 years</td>
</tr>
</tbody>
</table>
<ul>
<li>The air cleaning ﬁ lters are sold separately. When you replace them, contact the store of purchase.</li>
</ul>
<p><strong>Cleaning the indoor unit body</strong><br />
<strong>NOTES:</strong></p>
<ul>
<li>Do not use water hotter than 104 °F (40 °C).</li>
<li>Do not use scouring cleanser or volatile solvents such as benzene or thinner.<br />
1. Wipe the indoor unit body gently with a soft cloth moistened with warm water.<br />
2. Wipe the indoor unit body gently with a dry and soft cloth.</li>
</ul>
<p><strong>Cleaning air ﬁlter</strong></p>
<ol>
<li>Open the intake grille until it snaps.<br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/06/FUJITSU-9387602227-Air-Conditioner-intake-grille.webp" /></li>
<li>Remove the air ﬁlters.<br />
Lift up the air ﬁlters’ handle, disconnect the two lower tabs, and pull out.<br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/06/FUJITSU-9387602227-Air-Conditioner-handle.webp" /></li>
<li>Remove the dust in either of the following ways.<br />
• Cleaning with a vacuum cleaner.<br />
• Washing with mild detergent and warm water. After washing, dry the air ﬁlters thoroughly in shade.</li>
<li>Replace the air ﬁ lters.<br />
Align the sides of the air ﬁ lter with the panel, and push in fully.<br />
Make sure to the two lower tabs are returned to their holes in the indoor unit properly.</li>
<li>Close the intake grille.<br />
Press 4 places on the intake grille to close it completely.<br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/06/FUJITSU-9387602227-Air-Conditioner-completely.webp" /></li>
</ol>
<p><strong>NOTE:</strong> If dirt accumulates on the air ﬁ lter, airﬂ ow will be reduced, operating efﬁciency will lower, and the noise will increase.</p>
<p><strong>Cleaning Ion deodorization ﬁ lter and Replacing Apple-catechin ﬁlter</strong></p>
<ol>
<li>Remove the air ﬁ lters. Refer to steps 1 ~ 2 of “Cleaning air ﬁlter”.</li>
<li>Remove the air cleaning ﬁ lters from the air cleaning ﬁlter holders.<br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/06/FUJITSU-9387602227-Air-Conditioner-fi-lter-2.webp" /></li>
<li>Flush the Ion deodorization ﬁ lter with high-pressure hot water until the surface of the ﬁlters are covered with water.</li>
<li>Wash the Ion deodorization ﬁ lter with a diluent neutral detergent.<br />
Do not ream or rub, otherwise, the deodorizing effect may decrease.</li>
<li>Rinse the Ion deodorization ﬁ lter with water ﬂow.</li>
<li>Dry the Ion deodorization ﬁ lter in shade.</li>
<li>Set the new or washed air cleaning ﬁ lters into the air cleaning ﬁ lter holders.<br />
NOTE: Use the Apple-catechin ﬁ lter as soon as possible after opening the package. The air cleaning effect decreases when the ﬁ lters are left in the opened package.</li>
<li>Install the air cleaning ﬁ lter holders to the air ﬁ lters.<br />
Engage the 4 hooks at the rear of the air cleaning ﬁ lter holder with the latch at both ends of the air ﬁlter.<br />
<img loading="lazy" decoding="async" class="size-full wp-image-3843170 aligncenter ezlazyloaded" src="images/53.webp" sizes="auto, " srcset="" alt="FUJITSU 9387602227 Air Conditioner - rear" width="599" height="338" data-ezsrcset="https://manuals.plus/wp-content/uploads/2022/07/FUJITSU-9387602227-Air-Conditioner-rear.jpg?ezimgfmt=ng:webp/ngcb1 599w,https://manuals.plus/wp-content/uploads/2022/07/FUJITSU-9387602227-Air-Conditioner-rear-550x310.jpg?ezimgfmt=ng:webp/ngcb1 550w" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/07/FUJITSU-9387602227-Air-Conditioner-rear.jpg?ezimgfmt=rs:590x333/rscb1/ng:webp/ngcb1" /><strong>NOTE:</strong> Take care that the air cleaning ﬁ lter does not project beyond the holder.</li>
<li>Replace the air ﬁ lters and close the intake grille. Refer to steps 4 ~ 5 of “Cleaning air ﬁlter”.</li>
</ol>
<p><strong>Removing and installing intake grille</strong><br />
<strong>Removing intake grille</strong></p>
<ol>
<li>Open the intake grille until it snaps.</li>
<li>Pull the mounting shafts while keeping the intake grille in a horizontal position.</li>
</ol>
<p><img loading="lazy" decoding="async" class="size-full wp-image-3843175 aligncenter ezlazyloaded" src="images/54.webp" alt="FUJITSU 9387602227 Air Conditioner - Removing" width="536" height="304" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/07/FUJITSU-9387602227-Air-Conditioner-Removing.jpg?ezimgfmt=rs:536x304/rscb1/ng:webp/ngcb1" /></p>
<p><strong>■ Installing intake grille</strong></p>
<ol>
<li>While holding the intake grille horizontal, set the left and right mounting shafts into the pillow blocks at the top of the front panel.<br />
Insert the shaft until it snaps to latch each shaft properly.</li>
<li>Close the intake grille.</li>
<li>Press 4 places on the intake grille to close it completely.<br />
<img loading="lazy" decoding="async" class="size-full wp-image-3843123 aligncenter ezlazyloaded" src="images/55.webp" alt="FUJITSU 9387602227 Air Conditioner - grille" width="484" height="145" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/07/FUJITSU-9387602227-Air-Conditioner-grille.jpg?ezimgfmt=rs:484x145/rscb1/ng:webp/ngcb1" /></li>
</ol>
<h4>GENERAL INFORMATION</h4>
<p><strong>Heating performance</strong><br />
This air conditioner operates on the heat-pump principle, absorbing heat from air outdoors and transferring that heat to the indoor unit. As a result, the operating performance is reduced as outdoor air temperature drops.<br />
If you feel that the heating performance is insufﬁ cient, we recommend you to use this air conditioner in conjunction with other kinds of heating appliances.</p>
<p><strong>Automatic defrosting operation</strong><br />
When the outdoor temperature is very low with high humidity, frost may form on the outdoor unit during the heating operation, and it could reduce the operating performance of the product.<br />
For frost protection, an automatic defrost function is equipped in this air conditioner.<br />
If frost forms, the air conditioner will temporarily stop, and defrost circuit will operate brieﬂ y (maximum of 15 minutes.)<br />
[ <img loading="lazy" decoding="async" class="alignnone wp-image-3843126 ezlazyloaded" src="images/56.webp" alt="FUJITSU 9387602227 Air Conditioner - icon 2" width="12" height="27" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/07/FUJITSU-9387602227-Air-Conditioner-icon-2.jpg?ezimgfmt=rs:12x27/rscb1/ng:webp/ngcb1" />] indicator on the indoor unit blinks during this operation.<br />
If frost forms on the outdoor unit after the Heating operation, the outdoor unit will stop automatically after it operates for a few minutes. Then the Automatic defrosting operation starts.</p>
<p><strong>Auto-restart function</strong><br />
In event of a power interruption such as a blackout, the air conditioner stops once. But it restarts automatically and performs the previous operations when the power supply is resumed.<br />
If any power interruption occurs after the timer is set, the counting down of the timer will be reset.<br />
After the power supply is resumed, the [<strong><img loading="lazy" decoding="async" class="alignnone wp-image-3547442 ezlazyloaded" src="images/34.webp" alt="Stiebel Eltron CON 5 Premium Wall mounted convector heater - icon 5" width="38" height="32" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/06/Stiebel-Eltron-CON-5-Premium-Wall-mounted-convector-heater-icon-5.jpg?ezimgfmt=rs:38x32/rscb1/ng:webp/ngcb1" /></strong>] indicator on the indoor unit blinks to notify you that there has been a timer fault. In such a case, reset the clock and timer settings.</p>
<p><strong>Malfunctions caused by other electrical devices</strong><br />
Use of other electrical appliances such as an electric shaver or nearby use of a wireless radio transmitter may cause the malfunction of the air conditioner.<br />
If you encounter such a malfunction, turn off the circuit breaker once.<br />
Then turn it on again, and resume operation by using the remote controller.</p>
<p><strong>Indoor unit temperature and humidity range</strong><br />
Permissible ranges of temperature and humidity are as follows:</p>
<table width="895">
<tbody>
<tr>
<td rowspan="2" width="233">Indoor temperature</td>
<td width="245">Cooling/Dry [°F (°C)]</td>
<td width="212">64 to 89 (18 to 32)</td>
</tr>
<tr>
<td width="245">Heating [°F (°C)]</td>
<td width="212">60 to 86 (16 to 30)</td>
</tr>
<tr>
<td colspan="2" width="478">Indoor humidity [%]</td>
<td width="212">80 or less ‘1/41)</td>
</tr>
</tbody>
</table>
<p>*1) If the air conditioner is used continuously for many hours, water may condense on the surface and drip.</p>
<ul>
<li>If the unit is operated under conditions except for the permissible temperature range, the air conditioner operation may stop because of the automatic protection circuit working.</li>
<li>Depending on the operating conditions, the heat exchanger may freeze, causing water leakage or other malfunction (in the Cooling or Dry mode).</li>
</ul>
<p><strong>Other information</strong></p>
<ul>
<li>Do not use the air conditioner for any purpose other than room cooling/drying, room heating, or fan.</li>
<li>For the permissible ranges of temperature and humidity for the outdoor unit, refer to the outdoor unit installation manual.</li>
</ul>
<p><strong>Emergency heat (Special setting)</strong><br />
An auxiliary heater can be used instead of the outdoor unit if the auxiliary heater is connected and the function is set correctly during installation.<br />
Consult authorized service personnel to use this function.<br />
To activate/deactivate this function, Press on the indoor unit for 2<br />
seconds or less during the Heating operation. (Refer to page 4.)<br />
During the Emergency heat operation, [<img loading="lazy" decoding="async" class="alignnone size-full wp-image-3843140 ezlazyloaded" src="images/57.webp" alt="FUJITSU 9387602227 Air Conditioner - icon 11" width="47" height="35" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/07/FUJITSU-9387602227-Air-Conditioner-icon-11.jpg?ezimgfmt=rs:47x35/rscb1/ng:webp/ngcb1" />] indicator lamp will blink (3 seconds on, 1 second off).</p>
<h4>OPTIONAL PARTS</h4>
<p><strong>12.1. Wired remote controller<br />
</strong>The optional wired remote controller can be used.<br />
You can use wired and wireless remote controllers together.<br />
However, some functions of the wireless remote controller are restricted.<br />
If you set the restricted functions, a beeping sound will be heard, [<img loading="lazy" decoding="async" class="alignnone wp-image-3843126 ezlazyloaded" src="images/58.webp" alt="FUJITSU 9387602227 Air Conditioner - icon 2" width="10" height="23" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/07/FUJITSU-9387602227-Air-Conditioner-icon-2.jpg?ezimgfmt=rs:10x23/rscb1/ng:webp/ngcb1" />], [ <strong><img loading="lazy" decoding="async" class="alignnone wp-image-3547442 ezlazyloaded" src="images/34.webp" alt="Stiebel Eltron CON 5 Premium Wall mounted convector heater - icon 5" width="38" height="32" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/06/Stiebel-Eltron-CON-5-Premium-Wall-mounted-convector-heater-icon-5.jpg?ezimgfmt=rs:38x32/rscb1/ng:webp/ngcb1" /></strong>], [ ] and [ ] indicator on the indoor unit will blink.<br />
&lt;Restricted functions for wireless remote controller&gt;<br />
When used together with a wired remote controller (2-wire)</p>
<p><strong>Powerful operation</strong><br />
You can use a wired remote controller and wireless LAN control together (optional).<br />
However, some operations from the mobile app are restricted.<br />
Multiple remote controllers, You can connect two wired remote controllers to one air conditioner.<br />
Either remote controller can control the air conditioner.<br />
However, the timer functions cannot be used by the secondary unit.</p>
<p><strong>Group control</strong><br />
One remote controller can control up to 16 air conditioners. All of the air conditioners will be operated with the same settings.<br />
You cannot use group control and wireless LAN control together.</p>
<p><strong>12.2. Wireless LAN control<br />
</strong>To use the wireless LAN control, the WLAN adapter and mobile app are necessary.<br />
For how to operate the mobile app, refer to the operation manual of the mobile app.<br />
Write down the SSID and the PIN code in the following table.</p>
<p><img loading="lazy" decoding="async" class="size-full wp-image-3843161 aligncenter ezlazyloaded" src="images/59.webp" sizes="auto, " srcset="" alt="FUJITSU 9387602227 Air Conditioner - LAN label" width="785" height="197" data-ezsrcset="https://manuals.plus/wp-content/uploads/2022/07/FUJITSU-9387602227-Air-Conditioner-LAN-label.jpg?ezimgfmt=ng:webp/ngcb1 785w,https://manuals.plus/wp-content/uploads/2022/07/FUJITSU-9387602227-Air-Conditioner-LAN-label-550x138.jpg?ezimgfmt=ng:webp/ngcb1 550w,https://manuals.plus/wp-content/uploads/2022/07/FUJITSU-9387602227-Air-Conditioner-LAN-label-768x193.jpg?ezimgfmt=ng:webp/ngcb1 768w" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/07/FUJITSU-9387602227-Air-Conditioner-LAN-label.jpg?ezimgfmt=rs:612x154/rscb1/ng:webp/ngcb1" /></p>
<p><strong>Information on WLAN adapter</strong></p>
<table width="733">
<tbody>
<tr>
<td width="236">SSID</td>
<td width="497"></td>
</tr>
<tr>
<td>PIN</td>
<td></td>
</tr>
</tbody>
</table>
<p>Google Play is a registered trademark of Google Inc.<br />
App Store is a service mark of Apple Inc., registered in the U.S. and other countries.</p>
<p><strong>Setting to use wireless LAN control</strong><br />
Step 1. Application software installation</p>
<ol>
<li>Open “Google Play” or “App Store” depending on the type of your smartphone or tablet PC.</li>
<li>Search for “fair”.</li>
<li>Install the application software (mobile app) following the instructions on your screen.</li>
</ol>
<p><strong>Step 2. User registration</strong></p>
<ol>
<li>Open the installed mobile app.</li>
<li>Register the user (with either a smartphone or tablet PC) by following the instructions in the create an account section of the mobile app.</li>
</ol>
<p><strong>Step 3. Installing WLAN adapter</strong></p>
<p><strong>CAUTION</strong></p>
<ul>
<li><strong><img decoding="async" class="alignnone wp-image-2012555 ezlazyloaded" src="images/7.webp" alt="important icon" width="49" height="47" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/02/important-icon.jpg?ezimgfmt=rs:49x46/rscb1/ng:webp/ngcb1" /></strong>Be sure to turn off the power supply of the air conditioner when installing or removing this product to avoid the risk of electric shock.</li>
<li><strong><img decoding="async" class="alignnone wp-image-3801712 ezlazyloaded" src="images/8.webp" alt="Flysky FS VK G4P Digital Proportional Radio Control System - icon 1" width="51" height="44" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/07/Flysky-FS-VK-G4P-Digital-Proportional-Radio-Control-System-icon-1.jpg?ezimgfmt=rs:51x44/rscb1/ng:webp/ngcb1" /></strong>Do not put ﬁngers, sticks, etc. in the connection part of this product and the connection slot of the indoor unit.<br />
Otherwise, electric shock or damage to the product may occur.</li>
<li>Do not stand on an unstable platform when installing or removing this product to avoid injury.</li>
</ul>
<ol>
<li>Be sure to turn air conditioner off and to disconnect all the power supply.</li>
<li>Open the intake grille.<br />
<img loading="lazy" decoding="async" class="size-full wp-image-3843122 aligncenter ezlazyloaded" src="images/60.webp" sizes="auto, " srcset="" alt="FUJITSU 9387602227 Air Conditioner - fi lter" width="736" height="214" data-ezsrcset="https://manuals.plus/wp-content/uploads/2022/07/FUJITSU-9387602227-Air-Conditioner-fi-lter.jpg?ezimgfmt=ng:webp/ngcb1 736w,https://manuals.plus/wp-content/uploads/2022/07/FUJITSU-9387602227-Air-Conditioner-fi-lter-550x160.jpg?ezimgfmt=ng:webp/ngcb1 550w" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/07/FUJITSU-9387602227-Air-Conditioner-fi-lter.jpg?ezimgfmt=rs:590x172/rscb1/ng:webp/ngcb1" /></li>
<li>Open the WLAN adapter cover until it snaps.<br />
<img loading="lazy" decoding="async" class="size-full wp-image-3843101 aligncenter ezlazyloaded" src="images/61.webp" sizes="auto, " srcset="" alt="FUJITSU 9387602227 Air Conditioner - intake grille 2" width="589" height="233" data-ezsrcset="https://manuals.plus/wp-content/uploads/2022/07/FUJITSU-9387602227-Air-Conditioner-intake-grille-2.jpg?ezimgfmt=ng:webp/ngcb1 589w,https://manuals.plus/wp-content/uploads/2022/07/FUJITSU-9387602227-Air-Conditioner-intake-grille-2-550x218.jpg?ezimgfmt=ng:webp/ngcb1 550w" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/07/FUJITSU-9387602227-Air-Conditioner-intake-grille-2.jpg?ezimgfmt=rs:589x233/rscb1/ng:webp/ngcb1" /></li>
<li>Plug the WLAN adapter into the connection slot of the indoor unit in the direction as shown in the ﬁ gure.<br />
<img loading="lazy" decoding="async" class="size-full wp-image-3843102 aligncenter ezlazyloaded" src="images/62.webp" alt="FUJITSU 9387602227 Air Conditioner - intake grille 3" width="525" height="255" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/07/FUJITSU-9387602227-Air-Conditioner-intake-grille-3.jpg?ezimgfmt=rs:525x255/rscb1/ng:webp/ngcb1" /></li>
<li>Close the WLAN adapter cover and the intake grille.</li>
</ol>
<p><strong>Step 4.</strong> Air conditioner registration (pairing of WLAN adapter)<br />
<strong>NOTES:</strong></p>
<ul>
<li>Before starting this setting, reconnect the power supply of the air conditioner and wait for 60 seconds or more.</li>
<li>Check that the smartphone or tablet PC is linked to the access point you are connecting to the air conditioner. The setting will not work if it is not connected to the same access point.</li>
<li>To control 2 or more air conditioners with the same smartphone or tablet PC, repeat the setup of the chosen model.<br />
<img loading="lazy" decoding="async" class="alignnone size-full wp-image-3843128 ezlazyloaded" src="images/26.webp" alt="FUJITSU 9387602227 Air Conditioner - icon 4" width="39" height="22" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/07/FUJITSU-9387602227-Air-Conditioner-icon-4.jpg?ezimgfmt=rs:39x22/rscb1/ng:webp/ngcb1" /> Register the air conditioner by following the instructions on the mobile app.<br />
This operation manual describes only the setting procedure of the remote controller.</li>
</ul>
<p>When the registration is completed, the [<img loading="lazy" decoding="async" class="alignnone size-full wp-image-3843125 ezlazyloaded" src="images/17.webp" alt="FUJITSU 9387602227 Air Conditioner - icon 1" width="40" height="29" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/07/FUJITSU-9387602227-Air-Conditioner-icon-1.jpg?ezimgfmt=rs:40x29/rscb1/ng:webp/ngcb1" />]indicator on the indoor unit will turn on.</p>
<p><strong>For reference</strong><br />
&lt;Manual connection&gt;<br />
Setting procedure of the remote controller<br />
<strong>NOTE:</strong> If you do not press any buttons on the remote controller for 60 seconds, the remote controller display will return to the original display.</p>
<ol>
<li>Press<img loading="lazy" decoding="async" class="alignnone size-full wp-image-3843125 ezlazyloaded" src="images/17.webp" alt="FUJITSU 9387602227 Air Conditioner - icon 1" width="40" height="29" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/07/FUJITSU-9387602227-Air-Conditioner-icon-1.jpg?ezimgfmt=rs:40x29/rscb1/ng:webp/ngcb1" /> 2 times as shown in page 3.<br />
<code><strong>L2</strong></code> will be displayed on the remote controller display.<br />
<img loading="lazy" decoding="async" class="size-full wp-image-3843116 aligncenter ezlazyloaded" src="images/63.webp" alt="FUJITSU 9387602227 Air Conditioner - connection" width="205" height="128" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/07/FUJITSU-9387602227-Air-Conditioner-connection.jpg?ezimgfmt=rs:205x128/rscb1/ng:webp/ngcb1" /></li>
<li>Press<strong><img loading="lazy" decoding="async" class="alignnone size-full-size wp-image-3459657 ezlazyloaded" src="images/22.webp" alt="MIXX OX2 MOTH On Ear Wireless Headphones - icon 1" width="31" height="33" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/06/MIXX-OX2-MOTH-On-Ear-Wireless-Headphones-icon-1.jpg?ezimgfmt=rs:31x33/rscb1/ng:webp/ngcb1" /></strong>.</li>
<li>Make sure that “<strong><code>01</code></strong> ” is shown on the remote controller display. If “ <code>02</code>” is shown, press<img loading="lazy" decoding="async" class="alignnone size-full wp-image-3843137 ezlazyloaded" src="images/24.webp" alt="FUJITSU 9387602227 Air Conditioner - icon 8" width="71" height="25" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/07/FUJITSU-9387602227-Air-Conditioner-icon-8.jpg?ezimgfmt=rs:71x25/rscb1/ng:webp/ngcb1" /> to select “<code>01</code> ”,<br />
<img loading="lazy" decoding="async" class="size-full wp-image-3843110 aligncenter ezlazyloaded" src="images/64.webp" alt="FUJITSU 9387602227 Air Conditioner - connection 2" width="187" height="137" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/07/FUJITSU-9387602227-Air-Conditioner-connection-2.jpg?ezimgfmt=rs:187x137/rscb1/ng:webp/ngcb1" /></li>
<li>Press<strong><img loading="lazy" decoding="async" class="alignnone size-full-size wp-image-3459657 ezlazyloaded" src="images/22.webp" alt="MIXX OX2 MOTH On Ear Wireless Headphones - icon 1" width="31" height="33" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/06/MIXX-OX2-MOTH-On-Ear-Wireless-Headphones-icon-1.jpg?ezimgfmt=rs:31x33/rscb1/ng:webp/ngcb1" /></strong>.<br />
The indoor unit enters the Manual connection mode and the [<img loading="lazy" decoding="async" class="alignnone size-full wp-image-3843125 ezlazyloaded" src="images/17.webp" alt="FUJITSU 9387602227 Air Conditioner - icon 1" width="40" height="29" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/07/FUJITSU-9387602227-Air-Conditioner-icon-1.jpg?ezimgfmt=rs:40x29/rscb1/ng:webp/ngcb1" />] indicator on the indoor unit will blink.<br />
<strong>NOTE:</strong> If the registration is not ﬁnished in several minutes, the Manual mode is canceled, and the [<img loading="lazy" decoding="async" class="alignnone size-full wp-image-3843125 ezlazyloaded" src="images/17.webp" alt="FUJITSU 9387602227 Air Conditioner - icon 1" width="40" height="29" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/07/FUJITSU-9387602227-Air-Conditioner-icon-1.jpg?ezimgfmt=rs:40x29/rscb1/ng:webp/ngcb1" />] indicator turns off.<br />
In this case, repeat the remote controller setting.</li>
</ol>
<p><strong>&lt;Easy connection&gt;</strong><br />
Setting procedure of the remote controller<br />
<strong>NOTE:</strong> If you do not press any buttons of the remote controller for 60 seconds, the remote controller display will return to the original display.</p>
<ol>
<li>Press <img loading="lazy" decoding="async" class="alignnone size-full wp-image-3843125 ezlazyloaded" src="images/17.webp" alt="FUJITSU 9387602227 Air Conditioner - icon 1" width="40" height="29" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/07/FUJITSU-9387602227-Air-Conditioner-icon-1.jpg?ezimgfmt=rs:40x29/rscb1/ng:webp/ngcb1" />2 times as shown in page 3.<br />
<strong><code>L2</code></strong> will be displayed on the remote controller display.<br />
<img loading="lazy" decoding="async" class="size-full wp-image-3843111 aligncenter ezlazyloaded" src="images/65.webp" alt="FUJITSU 9387602227 Air Conditioner - connection 3" width="206" height="129" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/07/FUJITSU-9387602227-Air-Conditioner-connection-3.jpg?ezimgfmt=rs:206x129/rscb1/ng:webp/ngcb1" /></li>
<li>Press<strong><img loading="lazy" decoding="async" class="alignnone size-full-size wp-image-3459657 ezlazyloaded" src="images/22.webp" alt="MIXX OX2 MOTH On Ear Wireless Headphones - icon 1" width="31" height="33" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/06/MIXX-OX2-MOTH-On-Ear-Wireless-Headphones-icon-1.jpg?ezimgfmt=rs:31x33/rscb1/ng:webp/ngcb1" /></strong>.</li>
<li>Select <code>02</code> using<img loading="lazy" decoding="async" class="alignnone size-full wp-image-3843137 ezlazyloaded" src="images/24.webp" alt="FUJITSU 9387602227 Air Conditioner - icon 8" width="71" height="25" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/07/FUJITSU-9387602227-Air-Conditioner-icon-8.jpg?ezimgfmt=rs:71x25/rscb1/ng:webp/ngcb1" />.<img loading="lazy" decoding="async" class="size-full wp-image-3843112 aligncenter ezlazyloaded" src="images/66.webp" alt="FUJITSU 9387602227 Air Conditioner - connection 4" width="211" height="146" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/07/FUJITSU-9387602227-Air-Conditioner-connection-4.jpg?ezimgfmt=rs:211x146/rscb1/ng:webp/ngcb1" /></li>
<li>Press<strong><img loading="lazy" decoding="async" class="alignnone size-full-size wp-image-3459657 ezlazyloaded" src="images/22.webp" alt="MIXX OX2 MOTH On Ear Wireless Headphones - icon 1" width="31" height="33" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/06/MIXX-OX2-MOTH-On-Ear-Wireless-Headphones-icon-1.jpg?ezimgfmt=rs:31x33/rscb1/ng:webp/ngcb1" /></strong>.<br />
The indoor unit enters the Easy connection mode and the [<img loading="lazy" decoding="async" class="alignnone size-full wp-image-3843125 ezlazyloaded" src="images/17.webp" alt="FUJITSU 9387602227 Air Conditioner - icon 1" width="40" height="29" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/07/FUJITSU-9387602227-Air-Conditioner-icon-1.jpg?ezimgfmt=rs:40x29/rscb1/ng:webp/ngcb1" />]indicator on the indoor unit will blink (on/off = 1 s/1 s).<br />
When the WLAN adapter ﬁnd a connectable access point, the blinking will become slower (on/off = 2 s/0.5 s).<br />
<strong>NOTE:</strong> If the connection to the access point is not ﬁnished in several minutes, the Easy connection mode is canceled, and the [<img loading="lazy" decoding="async" class="alignnone size-full wp-image-3843125 ezlazyloaded" src="images/17.webp" alt="FUJITSU 9387602227 Air Conditioner - icon 1" width="40" height="29" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/07/FUJITSU-9387602227-Air-Conditioner-icon-1.jpg?ezimgfmt=rs:40x29/rscb1/ng:webp/ngcb1" />] indicator turns off.<br />
In this case, repeat the remote controller setting.</li>
</ol>
<p><strong>Temporary deactivation of wireless LAN</strong><br />
<strong>NOTE:</strong> If you do not press any buttons on the remote controller for 60 seconds, the remote controller display will return to the original display.</p>
<ol>
<li>Press with the tip of a ballpoint pen or other small object. “<img loading="lazy" decoding="async" class="alignnone size-full wp-image-3843125 ezlazyloaded" src="images/17.webp" alt="FUJITSU 9387602227 Air Conditioner - icon 1" width="40" height="29" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/07/FUJITSU-9387602227-Air-Conditioner-icon-1.jpg?ezimgfmt=rs:40x29/rscb1/ng:webp/ngcb1" />” will appear.<br />
<img loading="lazy" decoding="async" class="size-full wp-image-3843115 aligncenter ezlazyloaded" src="images/67.webp" alt="FUJITSU 9387602227 Air Conditioner - connection 7" width="218" height="140" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/07/FUJITSU-9387602227-Air-Conditioner-connection-7.jpg?ezimgfmt=rs:218x140/rscb1/ng:webp/ngcb1" /></li>
<li>Press<strong><img loading="lazy" decoding="async" class="alignnone size-full-size wp-image-3459657 ezlazyloaded" src="images/22.webp" alt="MIXX OX2 MOTH On Ear Wireless Headphones - icon 1" width="31" height="33" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/06/MIXX-OX2-MOTH-On-Ear-Wireless-Headphones-icon-1.jpg?ezimgfmt=rs:31x33/rscb1/ng:webp/ngcb1" /></strong>.<br />
The current status will appear.</p>
<table width="636">
<tbody>
<tr>
<td width="236"></td>
<td width="400">Activated</td>
</tr>
<tr>
<td></td>
<td>Deactivated</td>
</tr>
</tbody>
</table>
</li>
<li>Select<img loading="lazy" decoding="async" class="alignnone size-full wp-image-3843141 ezlazyloaded" src="images/68.webp" alt="FUJITSU 9387602227 Air Conditioner - icon 12" width="40" height="38" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/07/FUJITSU-9387602227-Air-Conditioner-icon-12.jpg?ezimgfmt=rs:40x38/rscb1/ng:webp/ngcb1" /> using.<img loading="lazy" decoding="async" class="size-full wp-image-3843113 aligncenter ezlazyloaded" src="images/69.webp" alt="FUJITSU 9387602227 Air Conditioner - connection 5" width="172" height="125" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/07/FUJITSU-9387602227-Air-Conditioner-connection-5.jpg?ezimgfmt=rs:172x125/rscb1/ng:webp/ngcb1" /></li>
<li>Press<strong><img loading="lazy" decoding="async" class="alignnone size-full-size wp-image-3459657 ezlazyloaded" src="images/22.webp" alt="MIXX OX2 MOTH On Ear Wireless Headphones - icon 1" width="31" height="33" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/06/MIXX-OX2-MOTH-On-Ear-Wireless-Headphones-icon-1.jpg?ezimgfmt=rs:31x33/rscb1/ng:webp/ngcb1" /></strong>.<br />
[<img loading="lazy" decoding="async" class="alignnone size-full wp-image-3843125 ezlazyloaded" src="images/17.webp" alt="FUJITSU 9387602227 Air Conditioner - icon 1" width="40" height="29" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/07/FUJITSU-9387602227-Air-Conditioner-icon-1.jpg?ezimgfmt=rs:40x29/rscb1/ng:webp/ngcb1" />] indicator on the indoor unit will turn off.<br />
* If you want to activate wireless LAN control again, select “<code>ON</code>” at step 3.</li>
</ol>
<p><strong>Initialization (reset)</strong><br />
Initialize (reset) this product in the following situations:</p>
<ul>
<li>Changing the access point</li>
<li>Disposing of this product</li>
<li>Transferring this product to a third party</li>
</ul>
<p><strong>Unregister the air conditioner</strong><br />
Unregister the air conditioner by using the mobile app. (Refer to the operation manual of the mobile app for details.)<br />
<strong>Initialization of the WLAN adapter</strong><br />
<strong>NOTE:</strong> If you do not press any buttons on the remote controller for 60 seconds, the remote controller display will return to the original display.</p>
<ol>
<li>Press<img loading="lazy" decoding="async" class="alignnone size-full wp-image-3843125 ezlazyloaded" src="images/17.webp" alt="FUJITSU 9387602227 Air Conditioner - icon 1" width="40" height="29" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/07/FUJITSU-9387602227-Air-Conditioner-icon-1.jpg?ezimgfmt=rs:40x29/rscb1/ng:webp/ngcb1" /> 3 times as shown in page 3. <code><strong>L3</strong></code> will be displayed on the remote controller display.<br />
<img loading="lazy" decoding="async" class="size-full wp-image-3843114 aligncenter ezlazyloaded" src="images/70.webp" alt="FUJITSU 9387602227 Air Conditioner - connection 6" width="209" height="134" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/07/FUJITSU-9387602227-Air-Conditioner-connection-6.jpg?ezimgfmt=rs:209x134/rscb1/ng:webp/ngcb1" /></li>
<li>Press<strong><img loading="lazy" decoding="async" class="alignnone size-full-size wp-image-3459657 ezlazyloaded" src="images/22.webp" alt="MIXX OX2 MOTH On Ear Wireless Headphones - icon 1" width="31" height="33" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/06/MIXX-OX2-MOTH-On-Ear-Wireless-Headphones-icon-1.jpg?ezimgfmt=rs:31x33/rscb1/ng:webp/ngcb1" /></strong>.<br />
“<strong><code>In</code></strong> ” will appear.<img loading="lazy" decoding="async" class="size-full wp-image-3843115 aligncenter ezlazyloaded" src="images/67.webp" alt="FUJITSU 9387602227 Air Conditioner - connection 7" width="218" height="140" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/07/FUJITSU-9387602227-Air-Conditioner-connection-7.jpg?ezimgfmt=rs:218x140/rscb1/ng:webp/ngcb1" /></li>
<li>Press and hold for more than 5 seconds.<br />
[<img loading="lazy" decoding="async" class="alignnone size-full wp-image-3843125 ezlazyloaded" src="images/17.webp" alt="FUJITSU 9387602227 Air Conditioner - icon 1" width="40" height="29" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/07/FUJITSU-9387602227-Air-Conditioner-icon-1.jpg?ezimgfmt=rs:40x29/rscb1/ng:webp/ngcb1" />] indicator on the indoor unit will blink fast, then turn off.</li>
</ol>
<p><strong>To continue use</strong><br />
If you or a third party wishes to continue the use of the product, follow the procedures in “Air conditioner registration (pairing of WLAN adapter)” to reconnect to a different access point.<br />
<strong>NOTE:</strong> Wireless LAN setup is not possible if the previous owner did not unregister or initialize this product. In this case, contact your authorized service personnel.</p>
<p><strong>Firmware update<br />
</strong><strong><img decoding="async" class="alignnone wp-image-2015443 ezlazyloaded" src="images/6.webp" alt="" width="56" height="47" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/02/AC-INFINITY-AC-WFS12-Wall-And-Floor-Circulator-Fan-warning.jpg?ezimgfmt=rs:56x47/rscb1/ng:webp/ngcb1" />CAUTION</strong><br />
Do not pull out the power plug nor turn off the circuit breaker during the ﬁ rmware update of the indoor unit or WLAN adapter. It may cause malfunction.</p>
<p><strong>For WLAN adapter</strong><br />
The ﬁ rmware of the WLAN adapter may be updated automatically.<br />
During the update, you cannot operate the air conditioner from the mobile app. It will take a maximum of 5 minutes.<br />
<strong>For indoor unit</strong><br />
The ﬁ rmware of the indoor unit may be updated. You can set the schedule of the updating or update the ﬁ rmware manually from the mobile app. For details, refer to the operation manual for the mobile app.<br />
During the update, the indicator lamps blink and the air conditioner stops operation. (Refer to “State of indicator lamps”.) It will take a maximum of 30 minutes.</p>
<h4>TROUBLESHOOTING</h4>
<p>In the following events, immediately stop the operation of the air conditioner, and disconnect all the power supply by turning off the electrical breaker or disconnecting the power plug. Then consult your dealer or authorized service personnel.<br />
As long as the unit is connected to the power supply, it is not insulated from the power supply even if the unit is turned off.</p>
<ul>
<li>Unit smells of something burning or emits smoke</li>
<li>Water leaks from the unit</li>
</ul>
<p><strong>Does not operate at all.</strong></p>
<ul>
<li>Has there been a power outage?<br />
In this case, the unit restarts automatically after the power supply is resumed. (Refer to page 8.)</li>
<li>Has the circuit breaker been turned off?<br />
⇒ Turn on the circuit breaker.</li>
<li>Has a fuse blown out or the circuit breaker been tripped?<br />
⇒ Replace the fuse or reset the circuit breaker.</li>
<li>Is the timer operating?<br />
⇒ To check or deactivate the timer setting, refer to page 5.</li>
<li>&lt;When using the wireless LAN control&gt; Is the WLAN adapter in a ﬁrmware update?<br />
During the ﬁ rmware update of the WLAN adapter, you cannot operate the air conditioner from the mobile app. Operate from the remote controller or wait until the  update is complete (for a maximum of 5 minutes).</li>
<li>&lt;When using the wireless LAN control&gt; Is the indoor unit in a ﬁ rmware update?<br />
During the ﬁ rmware update of the indoor unit, the air conditioner stops operation. Wait until the update is complete. (for a maximum of 30 minutes).</li>
</ul>
<p><strong>Poor cooling or heating performance.</strong></p>
<ul>
<li>Is the unit operating under the conditions except for the permissible temperature range?<br />
In this case, the air conditioner may stop because of the automatic protection circuit working.</li>
<li>Is the air ﬁ lter dirty?<br />
⇒ Clean the air ﬁ lter. (Refer to page 7.)</li>
<li>Is the intake grille or outlet port of the indoor unit blocked?<br />
⇒ Remove the obstructions.</li>
<li>Is the room temperature adjusted appropriately?<br />
⇒ To change the temperature setting, refer to page 4.</li>
<li>Is a window or door left opened?<br />
⇒ Close the window or the door.</li>
<li>Is the fan speed set to Quiet?<br />
⇒ To change the fan speed, refer to page 4.</li>
<li>&lt;In the Cooling mode&gt; Is direct or strong sunlight shining into the room?<br />
⇒ Close the curtains.</li>
<li>&lt;In the Cooling mode&gt;Are there other heating apparatus or computers operating, or too many people in the room?<br />
⇒ Turn the heating apparatus or computers off, or set the temperature lower. (Refer to page 4.)</li>
</ul>
<p><strong>Humidity does not drop during the Dry operation.</strong></p>
<ul>
<li>You cannot set the target humidity in the Dry mode. If you feel high humidity, set the temperature lower.</li>
</ul>
<p><strong>Airﬂ ow is weak or stops.</strong></p>
<ul>
<li>Is the fan speed set to Quiet?<br />
⇒ To change the fan speed, refer to page 4.</li>
<li>Has the Fan Control for Energy Saving set? In this case, the indoor unit fan may stop temporarily while the Cooling operation.<br />
⇒ To cancel the Fan control for energy saving, refer to page 6.</li>
<li>&lt;In the Heating mode&gt; Have you just started the operation?<br />
In this case, the fan rotates at a very low speed temporarily to warm up the internal parts of the unit.</li>
<li>&lt;In the Heating mode&gt; Is the room temperature higher than the set temperature?<br />
In this case, the outdoor unit stops and the indoor unit fan rotates at a very low speed.</li>
<li>&lt;In the Heating mode&gt; Is [<img loading="lazy" decoding="async" class="alignnone wp-image-3843126 ezlazyloaded" src="images/58.webp" alt="FUJITSU 9387602227 Air Conditioner - icon 2" width="10" height="23" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/07/FUJITSU-9387602227-Air-Conditioner-icon-2.jpg?ezimgfmt=rs:10x23/rscb1/ng:webp/ngcb1" /> ] indicator blinking?<br />
In this case, the Automatic defrosting operation is working. The indoor unit stops for a maximum of 15 minutes. (Refer to page 8.)</li>
<li>&lt;In the Dry mode&gt; The indoor unit operates at low fan speed to adjust the room humidity and may stop from time to time.</li>
<li>&lt;In the Auto mode&gt; While the monitoring operation, the fan rotates at a very low speed.</li>
</ul>
<p><strong>Noise is heard.</strong></p>
<ul>
<li>Is the unit operating, or immediately after stopping operation? In this case, refrigerant ﬂ owing sound may be heard. It may be particularly noticeable for 2-3 minutes after starting the operation.</li>
<li>Do you hear a slight squeaking sound during the operation?<br />
This sound is produced by the minute expansion and contraction of the front panel caused by temperature change.</li>
<li>&lt;In the Heating mode&gt; Do you hear a sizzling sound?<br />
This sound is produced by the Automatic defrosting operation.<br />
(Refer to page 8.)</li>
</ul>
<p><strong>Smell coming from the unit.</strong></p>
<ul>
<li>The air conditioner may absorb various smells generated from interior textile, furniture, or cigarette smoke. These smells may be emitted during the operation.</li>
</ul>
<p><strong>Mist or steam is emitted from the unit.</strong></p>
<ul>
<li>&lt;In the Cooling or Dry mode&gt; A thin mist may be generated by condensation formed with a sudden cooling process.</li>
<li>&lt;In the Heating mode&gt; Is [<img loading="lazy" decoding="async" class="alignnone wp-image-3843126 ezlazyloaded" src="images/58.webp" alt="FUJITSU 9387602227 Air Conditioner - icon 2" width="10" height="23" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/07/FUJITSU-9387602227-Air-Conditioner-icon-2.jpg?ezimgfmt=rs:10x23/rscb1/ng:webp/ngcb1" />] indicator on the indoor unit blinking?<br />
In this case, steam may rise from the outdoor unit because of the Automatic defrosting operation. (Refer to page 8.)<br />
The outdoor unit emits water.</li>
<li>&lt;In the Heating mode&gt; The outdoor unit may emit water generated by the Automatic defrosting operation. (Refer to page 8.)<br />
The unit operates differently from the remote controller setting.</li>
<li>Are the batteries in the remote controller exhausted?<br />
⇒ Replace the batteries.<br />
Operation is delayed after the restart.</li>
<li>Has the power supply turned from Off to On suddenly?<br />
In this case, the compressor will not operate for about 3 minutes to prevent a blowout of the fuse.</li>
</ul>
<p>Immediately stop operation and turn off the electrical breaker in the following cases. Then consult authorized service personnel.</p>
<ul>
<li>The problem persists even if you perform these checks or diagnostics.</li>
<li>On the indoor unit, [ <img loading="lazy" decoding="async" class="alignnone wp-image-3843126 ezlazyloaded" src="images/56.webp" alt="FUJITSU 9387602227 Air Conditioner - icon 2" width="12" height="27" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/07/FUJITSU-9387602227-Air-Conditioner-icon-2.jpg?ezimgfmt=rs:12x27/rscb1/ng:webp/ngcb1" />] and [ <strong><img loading="lazy" decoding="async" class="alignnone wp-image-3547442 ezlazyloaded" src="images/71.webp" alt="Stiebel Eltron CON 5 Premium Wall mounted convector heater - icon 5" width="24" height="20" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/06/Stiebel-Eltron-CON-5-Premium-Wall-mounted-convector-heater-icon-5.jpg?ezimgfmt=rs:24x20/rscb1/ng:webp/ngcb1" /></strong>] blink while [<img loading="lazy" decoding="async" class="alignnone wp-image-3843127 ezlazyloaded" src="images/43.webp" alt="FUJITSU 9387602227 Air Conditioner - icon 3" width="32" height="28" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/07/FUJITSU-9387602227-Air-Conditioner-icon-3.jpg?ezimgfmt=rs:32x28/rscb1/ng:webp/ngcb1" /> ] is blinking fast.</li>
</ul>
<p><strong>NOTE:</strong> For any troubleshooting related to the wireless LAN control, refer to the setting manual for the WLAN adapter or the mobile app installed in your smartphone or tablet PC.</p>
<p><strong>State of indicator lamps</strong><br />
<img loading="lazy" decoding="async" class="alignnone size-full wp-image-3843125 ezlazyloaded" src="images/17.webp" alt="FUJITSU 9387602227 Air Conditioner - icon 1" width="40" height="29" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/07/FUJITSU-9387602227-Air-Conditioner-icon-1.jpg?ezimgfmt=rs:40x29/rscb1/ng:webp/ngcb1" />: The instruction is related to the wireless LAN control (optional). Lighting pattern: Off, On, Blinking, Any state</p>
<p>Lighting pattern:<img loading="lazy" decoding="async" class="alignnone size-full wp-image-3843142 ezlazyloaded" src="images/72.webp" alt="FUJITSU 9387602227 Air Conditioner - icon 13" width="35" height="33" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/07/FUJITSU-9387602227-Air-Conditioner-icon-13.jpg?ezimgfmt=rs:35x33/rscb1/ng:webp/ngcb1" /> Off, <img loading="lazy" decoding="async" class="alignnone size-full wp-image-3843143 ezlazyloaded" src="images/73.webp" alt="FUJITSU 9387602227 Air Conditioner - icon 14" width="36" height="28" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/07/FUJITSU-9387602227-Air-Conditioner-icon-14.jpg?ezimgfmt=rs:36x28/rscb1/ng:webp/ngcb1" />On<img loading="lazy" decoding="async" class="alignnone size-full wp-image-3843145 ezlazyloaded" src="images/74.webp" alt="FUJITSU 9387602227 Air Conditioner - icon 15" width="59" height="48" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/07/FUJITSU-9387602227-Air-Conditioner-icon-15.jpg?ezimgfmt=rs:59x48/rscb1/ng:webp/ngcb1" />, Blinking<img loading="lazy" decoding="async" class="alignnone size-full wp-image-3843146 ezlazyloaded" src="images/75.webp" alt="FUJITSU 9387602227 Air Conditioner - icon 16" width="51" height="16" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/07/FUJITSU-9387602227-Air-Conditioner-icon-16.jpg?ezimgfmt=rs:51x16/rscb1/ng:webp/ngcb1" />, Any state</p>
<p><img loading="lazy" decoding="async" class="aligncenter ezlazyloaded" src="images/76.webp" alt="FUJITSU 9387602227 Air Conditioner - icon 35" width="597" height="1463" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/07/FUJITSU-9387602227-Air-Conditioner-icon-35.jpg?ezimgfmt=rs:597x1463/rscb1/ng:webp/ngcb1" /><img loading="lazy" decoding="async" class="aligncenter ezlazyloaded" src="images/77.webp" alt="FUJITSU 9387602227 Air Conditioner - icon 36" width="603" height="256" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/07/FUJITSU-9387602227-Air-Conditioner-icon-36.jpg?ezimgfmt=rs:603x256/rscb1/ng:webp/ngcb1" /></p>
<p><strong>Manual Auto operation and Filter indicator reset</strong><br />
You can operate the air conditioner <img loading="lazy" decoding="async" class="alignnone size-full wp-image-3843140 ezlazyloaded" src="images/57.webp" alt="FUJITSU 9387602227 Air Conditioner - icon 11" width="47" height="35" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/07/FUJITSU-9387602227-Air-Conditioner-icon-11.jpg?ezimgfmt=rs:47x35/rscb1/ng:webp/ngcb1" />on the indoor unit. (Refer to page 4.)</p>
<table width="1061">
<tbody>
<tr>
<td width="111"><strong>Status</strong></td>
<td width="234"><strong>Length of pressing down</strong></td>
<td width="176"><strong>Mode or operation</strong></td>
</tr>
<tr>
<td width="111">In operation</td>
<td width="234">More than 3 seconds</td>
<td width="176">Stop</td>
</tr>
<tr>
<td rowspan="3" width="111">Stopping</td>
<td width="234">2 seconds or less</td>
<td width="176">Filter indicator reset</td>
</tr>
<tr>
<td width="234">More than 3 seconds and less than 10 seconds</td>
<td width="176">Auto</td>
</tr>
<tr>
<td width="234">More than 10 seconds (Only for servicing.) *1)</td>
<td width="176">Forced cooling</td>
</tr>
<tr>
<td width="111">In Heating operation</td>
<td width="234">2 seconds or less (Special setting) 2)</td>
<td width="176">Emergency heat</td>
</tr>
</tbody>
</table>
<ol>
<li>To stop the forced cooling, press this button or on the remote controller.</li>
<li>Refer to “Emergency heat (page 8)” for details.</li>
</ol>
<p><strong>Service check</strong><br />
If [<img loading="lazy" decoding="async" class="alignnone wp-image-3843126 ezlazyloaded" src="images/78.webp" alt="FUJITSU 9387602227 Air Conditioner - icon 2" width="15" height="34" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/07/FUJITSU-9387602227-Air-Conditioner-icon-2.jpg?ezimgfmt=rs:15x34/rscb1/ng:webp/ngcb1" /> ] and [ <strong><img loading="lazy" decoding="async" class="alignnone wp-image-3547442 ezlazyloaded" src="images/34.webp" alt="Stiebel Eltron CON 5 Premium Wall mounted convector heater - icon 5" width="38" height="32" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/06/Stiebel-Eltron-CON-5-Premium-Wall-mounted-convector-heater-icon-5.jpg?ezimgfmt=rs:38x32/rscb1/ng:webp/ngcb1" /></strong>] blink while [ <img loading="lazy" decoding="async" class="alignnone wp-image-3843127 ezlazyloaded" src="images/43.webp" alt="FUJITSU 9387602227 Air Conditioner - icon 3" width="32" height="28" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/07/FUJITSU-9387602227-Air-Conditioner-icon-3.jpg?ezimgfmt=rs:32x28/rscb1/ng:webp/ngcb1" />] is blinking fast on the indoor unit, check the error code. The error code is 2-digit numbers or characters.</p>
<ol>
<li>Press and hold for more than 5 seconds.<br />
<img loading="lazy" decoding="async" class="size-full wp-image-3843158 aligncenter ezlazyloaded" src="images/79.webp" alt="FUJITSU 9387602227 Air Conditioner - icon 29" width="506" height="151" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/07/FUJITSU-9387602227-Air-Conditioner-icon-29.jpg?ezimgfmt=rs:506x151/rscb1/ng:webp/ngcb1" />The remote controller will enter to the Service check mode and “ <img loading="lazy" decoding="async" class="alignnone size-full wp-image-3843146 ezlazyloaded" src="images/75.webp" alt="FUJITSU 9387602227 Air Conditioner - icon 16" width="51" height="16" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/07/FUJITSU-9387602227-Air-Conditioner-icon-16.jpg?ezimgfmt=rs:51x16/rscb1/ng:webp/ngcb1" /><img loading="lazy" decoding="async" class="alignnone size-full wp-image-3843146 ezlazyloaded" src="images/75.webp" alt="FUJITSU 9387602227 Air Conditioner - icon 16" width="51" height="16" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/07/FUJITSU-9387602227-Air-Conditioner-icon-16.jpg?ezimgfmt=rs:51x16/rscb1/ng:webp/ngcb1" />will be shown.</li>
<li>Press <strong>TEM/SLECT </strong> <img loading="lazy" decoding="async" class="alignnone size-full wp-image-3843137 ezlazyloaded" src="images/24.webp" alt="FUJITSU 9387602227 Air Conditioner - icon 8" width="71" height="25" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/07/FUJITSU-9387602227-Air-Conditioner-icon-8.jpg?ezimgfmt=rs:71x25/rscb1/ng:webp/ngcb1" />  to change the shown error code.<br />
The indoor unit emits 1 short beep each time the error code changes.<br />
When the corresponding error code is shown, the indoor unit emits multiple beeps, and all the indicator lamps on the indoor unit blink.<br />
<img loading="lazy" decoding="async" class="size-full wp-image-3843107 aligncenter ezlazyloaded" src="images/80.webp" alt="FUJITSU 9387602227 Air Conditioner - blink" width="534" height="95" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/07/FUJITSU-9387602227-Air-Conditioner-blink.jpg?ezimgfmt=rs:534x95/rscb1/ng:webp/ngcb1" /><img loading="lazy" decoding="async" class="size-full wp-image-3843157 aligncenter ezlazyloaded" src="images/81.webp" sizes="auto, " srcset="" alt="FUJITSU 9387602227 Air Conditioner - icon 28" width="764" height="201" data-ezsrcset="https://manuals.plus/wp-content/uploads/2022/07/FUJITSU-9387602227-Air-Conditioner-icon-28.jpg?ezimgfmt=ng:webp/ngcb1 764w,https://manuals.plus/wp-content/uploads/2022/07/FUJITSU-9387602227-Air-Conditioner-icon-28-550x145.jpg?ezimgfmt=ng:webp/ngcb1 550w" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/07/FUJITSU-9387602227-Air-Conditioner-icon-28.jpg?ezimgfmt=rs:590x155/rscb1/ng:webp/ngcb1" /></li>
</ol>
<p>To ﬁ nish the Service check mode, press<strong><img loading="lazy" decoding="async" class="alignnone size-full-size wp-image-3459657 ezlazyloaded" src="images/22.webp" alt="MIXX OX2 MOTH On Ear Wireless Headphones - icon 1" width="31" height="33" data-ezsrc="https://manuals.plus/wp-content/uploads/2022/06/MIXX-OX2-MOTH-On-Ear-Wireless-Headphones-icon-1.jpg?ezimgfmt=rs:31x33/rscb1/ng:webp/ngcb1" /></strong>.<br />
The remote controller will return to the original display.<br />
Tell the error code to authorized service personnel when consulting them.<br />
If the indoor unit emits multiple beeps at “00”, no error is detected.</p>
<form id="commentform" class="comment-form" action="https://manuals.plus/wp-comments-post.php" method="post" novalidate="">
<p class="form-submit">
</form>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>FUJITSU 36LPAS1 Inverter Driven Heat Pump Manual</title>
		<link>https://usemanuals.com/fujitsu/36lpas1-inverter/</link>
		
		<dc:creator><![CDATA[ItsManual]]></dc:creator>
		<pubDate>Tue, 27 Jun 2023 05:09:20 +0000</pubDate>
				<category><![CDATA[FUJITSU]]></category>
		<guid isPermaLink="false">https://usemanuals.com/?p=126381</guid>

					<description><![CDATA[FUJITSU 36LPAS1 Inverter Driven Heat Pump PRODUCT FEATURES Auto Changeover Weekly &#38; 24 hr. Timer Auto Louver Minimum Heat Mode Auto Restart Economy Mode Wireless Remote control Warranty Information 7 Year Compressor, 5 Year Parts out-of-the-box Warranty EFFICIENCIES 10 Year Compressor, 10 Year Parts Warranty when registered within 60 days of installation in a residence.12 Year Compressor, 12 Year Parts Warranty when registered within 60 days of installation in a residence, and installed by a Fujitsu Elite contractor. MODEL NUMBERS Indoor Unit ASUH36LPAS Outdoor Unit AOUH36LPAS1 System 36LPAS1 EFFICIENCIES SEER 18 EER 8.1 HSPF 11 COP kW/KW 3.21 BTU/hW 11.00 OUTDOOR TEMPERATURE OPERATION RANGE Cooling ˚F(˚C) 14 to 115 (-10 to 46) Heating 5 to 75 (-15 to 24) CAPACITIES Cooling Rated BTU/hW 33,000 Min.—Max. 9,900 – 34,100 Heating Rated 34,000 Min.—Max. 8,700 – 35,000 LINESET REQUIREMENTS Connection Method Flare Liquid in (mm) Ø3/8 (Ø9.52) Gas Ø5/8 (Ø15.88) Pre-Charge Length ft m Minimum Length 66 (20) Maximum Length 164 (50) Max. Height Diff. 98 (30) INDOOR DIMENSIONS &#38; WEIGHT Net H x W x D in 13-3/8 × 45-1/4 × 11 mm 340 x 1,150 x 280 Gross H x W x D in 15-15/16 × 50 × 17-11/16 mm 405 × 1,270 × 450 Net Weight lb (kg) 39 (17.5) Gross Weight 51 (23.0) OUTDOOR DIMENSIONS &#38; WEIGHT Net H x W x D in 31 × 37 × 12-5/8 mm 788 × 940 × 320 Gross H x W x D in 38-1/16 × 40-7/16 × 17-1/2 mm 966 × 1,027 × 445 Net Weight lb (kg) 117 (53) Gross Weight 134 (61) Accessories that required ACCESSORIES UTY-RNRUZ* Wired Remote Controller (Touch Panel) UTY-RSRY Simple Remote Control UTY-RHRY Simple Remote Control (Hospitality) UTY-XWZXZ5 Dry Contact Wire Kit UTY-TTRXZ1 3rd Party Thermostat Converter UTY-TWRXZ2 Interface Kit UTY-TFSXF1 WIFI Module UTY-VMSX Modbus Converter FJ-AC-BAC-1L BACnet Adapter This system combination is Energy Star qualified. App available in Apple App Store and Google Play Store. Due to continuous product improvements, specifications are subject to change without notice. Please log in to the Fujitsu Portal for the most up to date documentation https://portal.fujitsugeneral.com Wall Bracket Data Inverter Driven Heat Pump DIMENSIONS Outdoor Unit TOP VIEW FRONT, SIDE AND REAR VIEW BOTTOM VIEW The Fujitsu logo is a worldwide trademark of Fujitsu General Limited. The Halcyon logo and name is a worldwide trademark of Fujitsu General Limited and is a registered trademark in Japan, the USA and other countries or areas. Copyright 2022 Fujitsu General America, Inc. Fujitsu’s products are subject to continuous improvements. Fujitsu reserves the right to modify product design, specifications and information in this brochure without notice and without incurring any obligations. Note Specifications are based on the following conditions: Cooling: Indoor temperature of 80°F (26.7°C) DB/67°F (19.4°C) WB, and outdoor temperature of 95°F (35°C) DB/75°F (23.9°C) WB. Heating: Indoor temperature of 70°F (21.1°C) DB/60°F (15.6°C) WB, and outdoor temperature of 47°F (8.3°C) DB/43°F (6.1°C) WB. Pipe length: 25ft 7.5m, Height difference: 0ft. 0m Outdoor unit  indoor unit. [...]<p><a class="btn btn-secondary understrap-read-more-link" href="https://usemanuals.com/fujitsu/36lpas1-inverter/">Read More...</a></p>]]></description>
										<content:encoded><![CDATA[<h3><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/06/unnamed-file-100.webp" /></h3>
<h4>FUJITSU 36LPAS1 Inverter Driven Heat Pump</h4>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/06/unnamed-file-100.webp" /></p>
<h4>PRODUCT FEATURES</h4>
<ul>
<li>Auto Changeover</li>
<li>Weekly &amp; 24 hr. Timer</li>
<li>Auto Louver</li>
<li>Minimum Heat Mode</li>
<li>Auto Restart</li>
<li>Economy Mode</li>
<li>Wireless Remote control</li>
</ul>
<p><strong>Warranty Information</strong></p>
<p>7 Year Compressor, 5 Year Parts out-of-the-box Warranty EFFICIENCIES 10 Year Compressor, 10 Year Parts Warranty when registered within 60 days of installation in a residence.12 Year Compressor, 12 Year Parts Warranty when registered within 60 days of installation in a residence, and installed by a Fujitsu Elite contractor.</p>
<table width="333">
<tbody>
<tr>
<td colspan="4" width="364"><strong>MODEL NUMBERS</strong></td>
</tr>
<tr>
<td width="81">Indoor Unit</td>
<td width="68"></td>
<td width="68"></td>
<td width="148">ASUH36LPAS</td>
</tr>
<tr>
<td width="81">Outdoor Unit</td>
<td width="68"></td>
<td width="68"></td>
<td width="148">AOUH36LPAS1</td>
</tr>
<tr>
<td width="81">System</td>
<td width="68"></td>
<td width="68"></td>
<td width="148">36LPAS1</td>
</tr>
<tr>
<td colspan="4" width="364"><strong>EFFICIENCIES</strong></td>
</tr>
<tr>
<td width="81">SEER</td>
<td width="68"></td>
<td width="68"></td>
<td width="148">18</td>
</tr>
<tr>
<td width="81">EER</td>
<td width="68"></td>
<td width="68"></td>
<td width="148">8.1</td>
</tr>
<tr>
<td width="81">HSPF</td>
<td width="68"></td>
<td width="68"></td>
<td width="148">11</td>
</tr>
<tr>
<td rowspan="2" width="81">COP</td>
<td width="68">kW/KW</td>
<td colspan="2" width="215">3.21</td>
</tr>
<tr>
<td width="68">BTU/hW</td>
<td colspan="2" width="215">11.00</td>
</tr>
<tr>
<td colspan="4" width="364"><strong>OUTDOOR TEMPERATURE OPERATION RANGE</strong></td>
</tr>
<tr>
<td width="81">Cooling</td>
<td rowspan="2" width="68">˚F(˚C)</td>
<td colspan="2" width="215">14 to 115 (-10 to 46)</td>
</tr>
<tr>
<td width="81">Heating</td>
<td colspan="2" width="215">5 to 75 (-15 to 24)</td>
</tr>
<tr>
<td colspan="4" width="364"><strong>CAPACITIES</strong></td>
</tr>
<tr>
<td rowspan="2" width="81">Cooling</td>
<td width="68">Rated</td>
<td rowspan="4" width="68">BTU/hW</td>
<td width="148">33,000</td>
</tr>
<tr>
<td width="68">Min.—Max.</td>
<td width="148">9,900 – 34,100</td>
</tr>
<tr>
<td rowspan="2" width="81">Heating</td>
<td width="68">Rated</td>
<td width="148">34,000</td>
</tr>
<tr>
<td width="68">Min.—Max.</td>
<td width="148">8,700 – 35,000</td>
</tr>
<tr>
<td colspan="4" width="364"><strong>LINESET REQUIREMENTS</strong></td>
</tr>
<tr>
<td width="81">Connection Method</td>
<td width="68"></td>
<td width="68"></td>
<td width="148">Flare</td>
</tr>
<tr>
<td width="81">Liquid</td>
<td rowspan="2" width="68">in (mm)</td>
<td colspan="2" width="215">Ø3/8 (Ø9.52)</td>
</tr>
<tr>
<td width="81">Gas</td>
<td colspan="2" width="215">Ø5/8 (Ø15.88)</td>
</tr>
<tr>
<td width="81">Pre-Charge Length</td>
<td rowspan="4" width="68">ft m</td>
<td colspan="2" width="215"></td>
</tr>
<tr>
<td width="81">Minimum Length</td>
<td colspan="2" width="215">66 (20)</td>
</tr>
<tr>
<td width="81">Maximum Length</td>
<td colspan="2" width="215">164 (50)</td>
</tr>
<tr>
<td width="81">Max. Height Diff.</td>
<td colspan="2" width="215">98 (30)</td>
</tr>
<tr>
<td colspan="4" width="364"><strong>INDOOR DIMENSIONS &amp; WEIGHT</strong></td>
</tr>
<tr>
<td rowspan="2" width="81">Net H x W x D</td>
<td width="68">in</td>
<td colspan="2" width="215">13-3/8 × 45-1/4 × 11</td>
</tr>
<tr>
<td width="68">mm</td>
<td colspan="2" width="215">340 x 1,150 x 280</td>
</tr>
<tr>
<td rowspan="2" width="81">Gross H x W x D</td>
<td width="68">in</td>
<td colspan="2" width="215">15-15/16 × 50 × 17-11/16</td>
</tr>
<tr>
<td width="68">mm</td>
<td colspan="2" width="215">405 × 1,270 × 450</td>
</tr>
<tr>
<td width="81">Net Weight</td>
<td rowspan="2" width="68">lb (kg)</td>
<td colspan="2" width="215">39 (17.5)</td>
</tr>
<tr>
<td width="81">Gross Weight</td>
<td colspan="2" width="215">51 (23.0)</td>
</tr>
<tr>
<td colspan="4" width="364"><strong>OUTDOOR</strong> <strong>DIMENSIONS</strong> <strong>&amp; WEIGHT</strong></td>
</tr>
<tr>
<td rowspan="2" width="81">Net H x W x D</td>
<td width="68">in</td>
<td colspan="2" width="215">31 × 37 × 12-5/8</td>
</tr>
<tr>
<td width="68">mm</td>
<td colspan="2" width="215">788 × 940 × 320</td>
</tr>
<tr>
<td rowspan="2" width="81">Gross H x W x D</td>
<td width="68">in</td>
<td colspan="2" width="215">38-1/16 × 40-7/16 × 17-1/2</td>
</tr>
<tr>
<td width="68">mm</td>
<td colspan="2" width="215">966 × 1,027 × 445</td>
</tr>
<tr>
<td width="81">Net Weight</td>
<td rowspan="2" width="68">lb (kg)</td>
<td colspan="2" width="215">117 (53)</td>
</tr>
<tr>
<td width="81">Gross Weight</td>
<td colspan="2" width="215">134 (61)</td>
</tr>
</tbody>
</table>
<h4>Accessories that required</h4>
<table>
<tbody>
<tr>
<td colspan="2" width="184"><strong>ACCESSORIES</strong></td>
</tr>
<tr>
<td width="48">UTY-RNRUZ*</td>
<td width="135">Wired Remote Controller (Touch Panel)</td>
</tr>
<tr>
<td width="48">UTY-RSRY</td>
<td width="135">Simple Remote Control</td>
</tr>
<tr>
<td width="48">UTY-RHRY</td>
<td width="135">Simple Remote Control (Hospitality)</td>
</tr>
<tr>
<td width="48">UTY-XWZXZ5</td>
<td width="135">Dry Contact Wire Kit</td>
</tr>
<tr>
<td width="48">UTY-TTRXZ1</td>
<td width="135">3rd Party Thermostat Converter</td>
</tr>
<tr>
<td width="48">UTY-TWRXZ2</td>
<td width="135">Interface Kit</td>
</tr>
<tr>
<td width="48">UTY-TFSXF1</td>
<td width="135">WIFI Module</td>
</tr>
<tr>
<td width="48">UTY-VMSX</td>
<td width="135">Modbus Converter</td>
</tr>
<tr>
<td width="48">FJ-AC-BAC-1L</td>
<td width="135">BACnet Adapter</td>
</tr>
</tbody>
</table>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/06/unnamed-file-100.webp" /></p>
<p>This system combination is Energy Star qualified.</p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/06/unnamed-file-100.webp" />App available in Apple App Store and Google Play Store.</p>
<p>Due to continuous product improvements, specifications are subject to change without notice. Please log in to the Fujitsu Portal for the most up to date documentation <a href="https://portal.fujitsugeneral.com/" target="_blank" rel="noopener">https://portal.fujitsugeneral.com</a></p>
<h4>Wall Bracket Data</h4>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/06/unnamed-file-100.webp" /></p>
<h4>Inverter Driven Heat Pump</h4>
<h5>DIMENSIONS</h5>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/06/unnamed-file-100.webp" /></p>
<h4>Outdoor Unit</h4>
<h5>TOP VIEW</h5>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/06/unnamed-file-100.webp" /></p>
<h5>FRONT, SIDE AND REAR VIEW</h5>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/06/unnamed-file-100.webp" /></p>
<h5>BOTTOM VIEW</h5>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/06/unnamed-file-100.webp" /></p>
<p>The Fujitsu logo is a worldwide trademark of Fujitsu General Limited. The Halcyon logo and name is a worldwide trademark of Fujitsu General Limited and is a registered trademark in Japan, the USA and other countries or areas. Copyright 2022 Fujitsu General America, Inc. Fujitsu’s products are subject to continuous improvements. Fujitsu reserves the right to modify product design, specifications and information in this brochure without notice and without incurring any obligations.</p>
<p><strong>Note</strong><br />
Specifications are based on the following conditions: Cooling: Indoor temperature of 80°F (26.7°C) DB/67°F (19.4°C) WB, and outdoor temperature of 95°F (35°C) DB/75°F (23.9°C) WB. Heating: Indoor temperature of 70°F (21.1°C) DB/60°F (15.6°C) WB, and outdoor temperature of 47°F (8.3°C) DB/43°F (6.1°C) WB. Pipe length: 25ft 7.5m, Height difference: 0ft. 0m Outdoor unit  indoor unit.</p>
<form id="commentform" class="comment-form" action="https://manuals.plus/wp-comments-post.php" method="post" novalidate="">
<p class="form-submit">
</form>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>FUJITSU anywAir technology Manual</title>
		<link>https://usemanuals.com/fujitsu/anywair-technology/</link>
		
		<dc:creator><![CDATA[ItsManual]]></dc:creator>
		<pubDate>Sat, 22 Jul 2023 09:39:13 +0000</pubDate>
				<category><![CDATA[FUJITSU]]></category>
		<guid isPermaLink="false">https://usemanuals.com/?p=170667</guid>

					<description><![CDATA[FUJITSU anywAir technology User Guide STEP BY STEP GUIDE STEP 1 Download the application from Google play or App Store. Direct access to download links can be found at myanywair.com https://play.google.com/store/apps/details?id=com.intesis.anywair&#38;hl=en&#38;gl=US https://apps.apple.com/nz/app/anywair/id1509639853 STEP 2 Visit the wireless settings section of your wireless device (smartphone, tablet or laptop) and connect to the network generated by your device (DEVICE_xxxxxx). Apple, the Apple logo, iPhone and Siri are trademarks of Apple Inc., registered in the U.S. and other countries. App Store is a service mark of Apple Inc. Amazon, Alexa and all related logos are trademarks of Amazon.com, Inc. or its affiliates. ©2019 Google LLC All rights reserved. Google Play™ and Google Assistant™ are trademarks of Google LLC. Other trademarks and tradenames are acknowledged to be the copyright of their respective holders. Wi-Fi CONFIGURATION DEVICE REGISTRATION IR CONFIGURATION POSITION DEVICE There are several installation and placement options for the anywAiR technology Wi-Fi device. It can be installed side-by-side with the AC unit (case A), under the AC unit (case B), in front of the AC unit (case C) or on a desktop position (case D). ACCOUNT SETUP [...]<p><a class="btn btn-secondary understrap-read-more-link" href="https://usemanuals.com/fujitsu/anywair-technology/">Read More...</a></p>]]></description>
										<content:encoded><![CDATA[<pre><strong>FUJITSU anywAir technology User Guide</strong></pre>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/anywair-technology-logo-1.webp" /></p>
<p><strong>STEP BY STEP GUIDE</strong></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/Air-logo-1.webp" /></p>
<p><strong>STEP 1</strong><br />
Download the application from <a href="https://play.google.com/store/apps/details?id=com.intesis.anywair&amp;hl=en&amp;gl=US" target="_blank" rel="noopener">Google play</a> or <a href="https://apps.apple.com/nz/app/anywair/id1509639853" target="_blank" rel="noopener">App Store</a>. Direct access to download links can be found at <a href="http://myanywair.com/" target="_blank" rel="noopener">myanywair.com</a></p>
<figure id="attachment_467070" class="wp-caption aligncenter" aria-describedby="caption-attachment-467070"><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/FUJITSU-anywAir-technology-Android-apps-1.webp" /><figcaption id="caption-attachment-467070" class="wp-caption-text"><a href="https://play.google.com/store/apps/details?id=com.intesis.anywair&amp;hl=en&amp;gl=US" target="_blank" rel="noopener">https://play.google.com/store/apps/details?id=com.intesis.anywair&amp;hl=en&amp;gl=US</a></figcaption></figure>
<figure id="attachment_467072" class="wp-caption aligncenter" aria-describedby="caption-attachment-467072"><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/FUJITSU-anywAir-technology-apple-apps-1.webp" /><figcaption id="caption-attachment-467072" class="wp-caption-text"><a href="https://apps.apple.com/nz/app/anywair/id1509639853" target="_blank" rel="noopener">https://apps.apple.com/nz/app/anywair/id1509639853</a></figcaption></figure>
<p><strong>STEP 2</strong><br />
Visit the wireless settings section of your wireless device (smartphone, tablet or laptop) and connect to the network generated by your device (DEVICE_xxxxxx).</p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/FUJITSU-anywAir-technology-wifi-connection-1.webp" /></p>
<p>Apple, the Apple logo, iPhone and Siri are trademarks of Apple Inc., registered in the U.S. and other countries. App Store is a service mark of Apple Inc. Amazon, Alexa and all related logos are trademarks of Amazon.com, Inc. or its affiliates. ©2019 Google LLC All rights reserved. Google Play™ and Google Assistant™ are trademarks of Google LLC. Other trademarks and tradenames are acknowledged to be the copyright of their respective holders.</p>
<h4>Wi-Fi CONFIGURATION</h4>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/FUJITSU-anywAir-technology-Wi-Fi-CONFIGURATION-1.webp" /></p>
<h4>DEVICE REGISTRATION</h4>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/FUJITSU-anywAir-technology-DEVICE-REGISTRATION-scaled-2.webp" /></p>
<h4>IR CONFIGURATION</h4>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/FUJITSU-anywAir-technology-IR-CONFIGURATION-1.webp" /></p>
<h4>POSITION DEVICE</h4>
<p>There are several installation and placement options for the anywAiR technology Wi-Fi device. It can be installed side-by-side with the AC unit (case A), under the AC unit (case B), in front of the AC unit (case C) or on a desktop position (case D).</p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/FUJITSU-anywAir-technology-POSITION-DEVICE-1.webp" /></p>
<h4>ACCOUNT SETUP</h4>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/FUJITSU-anywAir-technology-ACCOUNT-SETUP-1.webp" /></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/Fujitsu-logo-1.webp" /></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/FUJITSU-general-assist-logo-1.webp" /></p>
<form id="commentform" class="comment-form" action="https://manuals.plus/wp-comments-post.php" method="post" novalidate="">
<p class="form-submit">
</form>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>

<!--
Performance optimized by W3 Total Cache. Learn more: https://www.boldgrid.com/w3-total-cache/

Page Caching using Disk: Enhanced 

Served from: usemanuals.com @ 2026-08-27 12:13:17 by W3 Total Cache
-->