<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>EXTECH &#8211; UseManuals</title>
	<atom:link href="http://usemanuals.com/extech/feed/" rel="self" type="application/rss+xml" />
	<link>https://usemanuals.com</link>
	<description>Owner&#039;s manuals for all sorts of products</description>
	<lastBuildDate>Sat, 05 Aug 2023 17:38:54 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.7.2</generator>

<image>
	<url>https://usemanuals.com/wp-content/uploads/2025/02/favicon-32x32-2.png</url>
	<title>EXTECH &#8211; UseManuals</title>
	<link>https://usemanuals.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>EXTECH Mini Hygro Thermo-Anemometer Manual</title>
		<link>https://usemanuals.com/extech/mini-anemometer/</link>
		
		<dc:creator><![CDATA[ItsManual]]></dc:creator>
		<pubDate>Wed, 26 Jul 2023 18:47:29 +0000</pubDate>
				<category><![CDATA[EXTECH]]></category>
		<guid isPermaLink="false">https://usemanuals.com/?p=177260</guid>

					<description><![CDATA[EXTECH Mini Hygro Thermo-Anemometer User Manual Introduction Congratulations on your purchase of Extech’s Model 45158 Anemometer. The dual display indicates Air Velocity and Humidity, Dew Point, Ambient Temperature, or Temperature with wind-chill factor. With careful use, this meter will provide years of reliable service. Operation Turning the meter ON and OFF Press the ON/OFF/HOLD button to turn the meter ON Press and hold the ON/OFF/HOLD buttons for approx. 3 seconds to turn it OFF The meter’s Auto Power OFF feature turns the meter OFF after 20 minutes of inactivity Change the lower display parameter With the meter ON, press and hold down the ON/OFF/HOLD button While continuing to hold the ON/OFF/HOLD button, press the UNITS/MODE button repeatedly to step through Temperature (oF/oC), Humidity (RH%), Dew Point (TD), &#38; Temperature with wind-chill factor (WCI). Note that the center display is Air Velocity. Change the Air Velocity unit of measure Turn the meter OFF. Press and hold down both buttons until the display turns on and begins blinking then release both buttons Press the UNITS/MODE button repeatedly to step through the units (see specs for list) After 5 seconds the meter switches back to normal operation mode automatically Select temperature units (oC or oF) Turn the meter OFF first. Press and hold down both buttons until the display turns on and begins blinking then release the buttons Press both buttons momentarily to change temperature units After 5 seconds the meter switches back to normal operation mode automatically Taking Measurements Position the meter so that the airflow enters the meter vane from the rear of the meter (opposite side of front panel logo). A tripod mount is located on the bottom of the meter. Max Hold Max Hold represents the highest measurement taken since the meter was turned on Press the UNITS/MODE button to display the Max reading (MAX icon appears) Press the UNITS/MODE button repeatedly to step through to the normal operating mode Average mode 5 or 10 reading averages can be displayed in the Average Mode. Press UNITS/MODE 3 times for 5 reading averaging or 4 times for 10 readings To exit this mode, press the UNITS/MODE button until the icons on the left disappear Data Hold Data Hold freezes the most recent displayed reading Press and hold the ON/OFF/HOLD button to activate Data Hold As long as the ON/OFF/HOLD button is held the reading will remain on the LCD Meter Description Vane impeller Impeller set screw (on rear of meter) Relative Humidity sensor Temperature sensor LCD display ON/OFF, HOLD key UNITS, MODE key Battery compartment (on rear) Tripod mounting hole Lanyard (neckstrap) Specifications Measurement Range Resolution Accuracy (% of reading) MPH (Miles per hour) 2.5 to 44.7 MPH 0.2 MPH ± (3% + 0.4 mph) km/hr (kilometers per hour) 4.0 to 72.0 km/h 0.7 km/h ± (3% + 1.4 km/hr) Knots (nautical miles per hour) 2.1 to 38.9 knots 0.3 knots ± (3% + 0.6 knots) m/sec (meters per second) 1.1 to 20.0 m/s 0.1 m/s ± (3% + 0.2 m/s) ft/min (feet per minute) 216 to 3936 ft/min 20ft/min ± (3% + 40 ft/min) Beaufort force 1 to 8 BF 1 BF ± 1 Temperature 0 to 122oF (-18 to 50oC) 0.1oF/C ± 1.8oF (± 1oC) Relative Humidity 10 to 95% 1% ± 5% RH Dew Point 32 to 122 oF (0 to 50oC) 0.1oF/C ± 3.6oF (2oC) General Specifications Display Dual LCD with low battery and multifunction indicators Sensors Sapphire bearing, non-corrosive vane for air velocity; Precision thermistor for temperature measurements Average Mode Choice of 5 or 10 reading averaging (2 second factory default) Max and Data Hold Displays Max recalls the highest reading; Data Hold freezes the display Sample time 1 reading per second for air velocity and temperature (1 reading per 15 seconds for humidity with 2 second updates) Water-resistant To 3’(1m) Operating conditions 5 to 122oF (-15 to 50oC) / &#60; 80% RH Power supply Lithium battery (CR-2032 or equivalent) / 400 hour battery life Dimensions / Weight Instrument: 133 x 70 x 19mm( 5.25 x 2.75 x 0.75”) Vane: 1’(24mm) diameter /3 oz.(95 g) Maintenance Battery Replacement The 45158 has a low battery indicator (battery symbol). Important: Turn the meter off before opening the battery compartment. Using a coin, turn the battery compartment cover CLOCKWISE to remove it. Once opened, observe the position of the battery, placing the new one in the same position. Secure the battery compartment cover and dispose of the lithium battery in accordance with local, state, or national disposal codes. All EU users are legally bound by the Battery Ordinance to return all used batteries to community collection points or wherever batteries / accumulators are sold. Disposal in household trash or refuse is prohibited. Disposal: Follow the valid legal stipulations in respect of the disposal of the device at the end of its lifecycle. Other Battery Safety Reminders Never dispose of batteries in a fire. Batteries may explode or leak. Never mix battery types. Always install new batteries of the same type. Impeller Replacement Remove the set screw next to the impeller assembly (on the rear of the meter). Twist the impeller assembly counter-clockwise to the OPEN position and remove it. Install impeller by inserting &#38; twisting the new impeller assembly clockwise Tighten the set screw. CFM Measurements Measure the area of the duct using the diagrams below for rectangular and circular ducts (If the duct measurements are made in inches, divide the inches by 144 to get the area in square feet). Plug the area value (in square feet) in the cubic equations below. Note that the air velocity must be plugged into the cubic equations also. A = w * h A = πr² CFM (ft³/min) = Air Velocity (ft/min) x Area (ft²) CMM (m³/min) = Air Velocity (m/sec) x Area (m²) x 60 Warranty Two-year Warranty FLIR Systems, Inc. warrants this Extech brand instrument to be free of defects in parts and workmanship for two years from date of shipment (a six-month limited warranty applies to sensors and cables). To view the full warranty text please visit: http://www.extech.com/support/warranties. Calibration and Repair Services FLIR Systems, Inc. offers calibration and repair services for the Extech brand products we sell. We offer NIST traceable calibration for most of our products. Contact us for information on calibration and repair availability, refer to the contact information below. Annual calibrations should be performed to verify meter performance and accuracy. Product specifications are subject to change without notice. Please visit our website for the most up-to-date product information: www.extech.com Contact Customer Support Customer Support Telephone List: https://support.flir.com/contact Calibration, Repair, and Returns: repair@extech.com Technical Support: https://support.flir.com Copyright © 2013- 2020 FLIR Systems, Inc. All rights reserved including the right of reproduction in whole or in part in any form www.extech.com [...]<p><a class="btn btn-secondary understrap-read-more-link" href="https://usemanuals.com/extech/mini-anemometer/">Read More...</a></p>]]></description>
										<content:encoded><![CDATA[<p><strong>EXTECH Mini Hygro Thermo-Anemometer User Manual<br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/0-54-300x282-1.webp" /></strong></p>
<h4>Introduction</h4>
<p>Congratulations on your purchase of Extech’s Model 45158 Anemometer. The dual display indicates Air Velocity and Humidity, Dew Point, Ambient Temperature, or Temperature with wind-chill factor. With careful use, this meter will provide years of reliable service.</p>
<h4>Operation</h4>
<p><strong>Turning the meter ON and OFF</strong></p>
<ul>
<li>Press the ON/OFF/HOLD button to turn the meter ON</li>
<li>Press and hold the ON/OFF/HOLD buttons for approx. 3 seconds to turn it OFF</li>
<li>The meter’s Auto Power OFF feature turns the meter OFF after 20 minutes of inactivity</li>
</ul>
<p><strong>Change the lower display parameter</strong></p>
<ul>
<li>With the meter ON, press and hold down the ON/OFF/HOLD button</li>
<li>While continuing to hold the ON/OFF/HOLD button, press the UNITS/MODE button repeatedly to step through Temperature (oF/oC), Humidity (RH%), Dew Point (TD), &amp; Temperature with wind-chill factor (WCI). Note that the center display is Air Velocity.</li>
</ul>
<p><strong>Change the Air Velocity unit of measure</strong></p>
<ul>
<li>Turn the meter OFF. Press and hold down both buttons until the display turns on and begins blinking then release both buttons</li>
<li>Press the UNITS/MODE button repeatedly to step through the units (see specs for list)</li>
<li>After 5 seconds the meter switches back to normal operation mode automatically</li>
</ul>
<p><strong>Select temperature units (oC or oF)</strong></p>
<ul>
<li>Turn the meter OFF first. Press and hold down both buttons until the display turns on and begins blinking then release the buttons</li>
<li>Press both buttons momentarily to change temperature units</li>
<li>After 5 seconds the meter switches back to normal operation mode automatically</li>
</ul>
<p><strong>Taking Measurements</strong></p>
<ul>
<li>Position the meter so that the airflow enters the meter vane from the rear of the meter (opposite side of front panel logo). A tripod mount is located on the bottom of the meter.</li>
</ul>
<p><strong>Max Hold</strong></p>
<ul>
<li>Max Hold represents the highest measurement taken since the meter was turned on</li>
<li>Press the UNITS/MODE button to display the Max reading (MAX icon appears)</li>
<li>Press the UNITS/MODE button repeatedly to step through to the normal operating mode</li>
</ul>
<p><strong>Average mode</strong></p>
<ul>
<li>5 or 10 reading averages can be displayed in the Average Mode.</li>
<li>Press UNITS/MODE 3 times for 5 reading averaging or 4 times for 10 readings</li>
<li>To exit this mode, press the UNITS/MODE button until the icons on the left disappear</li>
</ul>
<p><strong>Data Hold</strong></p>
<ul>
<li>Data Hold freezes the most recent displayed reading</li>
<li>Press and hold the ON/OFF/HOLD button to activate Data Hold</li>
<li>As long as the ON/OFF/HOLD button is held the reading will remain on the LCD</li>
</ul>
<h4>Meter Description</h4>
<p><img fetchpriority="high" decoding="async" class="alignnone wp-image-451182 ezlazyloaded" src="images/5.webp" sizes="" srcset="" alt="Product Overview" width="544" height="515" data-ezsrcset="https://manuals.plus/wp-content/uploads/2021/08/2-577-300x284.jpg?ezimgfmt=ng:webp/ngcb1 300w,https://manuals.plus/wp-content/uploads/2021/08/2-577-768x728.jpg?ezimgfmt=ng:webp/ngcb1 768w,https://manuals.plus/wp-content/uploads/2021/08/2-577.jpg?ezimgfmt=ng:webp/ngcb1 832w" data-ezsrc="https://manuals.plus/wp-content/uploads/2021/08/2-577-300x284.jpg?ezimgfmt=rs:544x515/rscb1/ng:webp/ngcb1" /></p>
<ol>
<li>Vane impeller</li>
<li>Impeller set screw (on rear of meter)</li>
<li>Relative Humidity sensor</li>
<li>Temperature sensor</li>
<li>LCD display</li>
<li>ON/OFF, HOLD key</li>
<li>UNITS, MODE key</li>
<li>Battery compartment (on rear)</li>
<li>Tripod mounting hole</li>
<li>Lanyard (neckstrap)</li>
</ol>
<h4>Specifications</h4>
<table width="994">
<tbody>
<tr>
<td width="80"><strong>Measurement</strong></td>
<td width="96"><strong>Range</strong></td>
<td width="54"><strong>Resolution</strong></td>
<td width="98"><strong>Accuracy (% of reading)</strong></td>
</tr>
<tr>
<td width="80"><strong>MPH (Miles per hour)</strong></td>
<td width="96">2.5 to 44.7 MPH</td>
<td width="54">0.2 MPH</td>
<td width="98">± (3% + 0.4 mph)</td>
</tr>
<tr>
<td width="80"><strong>km/hr (kilometers per hour)</strong></td>
<td width="96">4.0 to 72.0 km/h</td>
<td width="54">0.7 km/h</td>
<td width="98">± (3% + 1.4 km/hr)</td>
</tr>
<tr>
<td width="80"><strong>Knots (nautical miles per hour)</strong></td>
<td width="96">2.1 to 38.9 knots</td>
<td width="54">0.3 knots</td>
<td width="98">± (3% + 0.6 knots)</td>
</tr>
<tr>
<td width="80"><strong>m/sec (meters per second)</strong></td>
<td width="96">1.1 to 20.0 m/s</td>
<td width="54">0.1 m/s</td>
<td width="98">± (3% + 0.2 m/s)</td>
</tr>
<tr>
<td width="80"><strong>ft/min (feet per minute)</strong></td>
<td width="96">216 to 3936 ft/min</td>
<td width="54">20ft/min</td>
<td width="98">± (3% + 40 ft/min)</td>
</tr>
<tr>
<td width="80"><strong>Beaufort force</strong></td>
<td width="96">1 to 8 BF</td>
<td width="54">1 BF</td>
<td width="98">± 1</td>
</tr>
<tr>
<td width="80"><strong>Temperature</strong></td>
<td width="96">0 to 122oF (-18 to 50oC)</td>
<td width="54">0.1oF/C</td>
<td width="98">± 1.8oF (± 1oC)</td>
</tr>
<tr>
<td width="80"><strong>Relative Humidity</strong></td>
<td width="96">10 to 95%</td>
<td width="54">1%</td>
<td width="98">± 5% RH</td>
</tr>
<tr>
<td width="80"><strong>Dew Point</strong></td>
<td width="96">32 to 122 oF (0 to 50oC)</td>
<td width="54">0.1oF/C</td>
<td width="98">± 3.6oF (2oC)</td>
</tr>
</tbody>
</table>
<h5>General Specifications</h5>
<table width="978">
<tbody>
<tr>
<td width="108"><strong>Display</strong></td>
<td width="220">Dual LCD with low battery and multifunction indicators</td>
</tr>
<tr>
<td width="108"><strong>Sensors</strong></td>
<td width="220">Sapphire bearing, non-corrosive vane for air velocity; Precision thermistor for temperature measurements</td>
</tr>
<tr>
<td width="108"><strong>Average Mode</strong></td>
<td width="220">Choice of 5 or 10 reading averaging (2 second factory default)</td>
</tr>
<tr>
<td width="108"><strong>Max and Data Hold Displays</strong></td>
<td width="220">Max recalls the highest reading; Data Hold freezes the display</td>
</tr>
<tr>
<td width="108"><strong>Sample time</strong></td>
<td width="220">1 reading per second for air velocity and temperature (1 reading per 15 seconds for humidity with 2 second updates)</td>
</tr>
<tr>
<td width="108"><strong>Water-resistant</strong></td>
<td width="220">To 3’(1m)</td>
</tr>
<tr>
<td width="108"><strong>Operating conditions</strong></td>
<td width="220">5 to 122oF (-15 to 50oC) / &lt; 80% RH</td>
</tr>
<tr>
<td width="108"><strong>Power supply</strong></td>
<td width="220">Lithium battery (CR-2032 or equivalent) / 400 hour battery life</td>
</tr>
<tr>
<td width="108"><strong>Dimensions / Weight</strong></td>
<td width="220">
<ul>
<li><strong>Instrument:</strong> 133 x 70 x 19mm( 5.25 x 2.75 x 0.75”)</li>
<li>Vane: 1’(24mm) diameter /3 oz.(95 g)</li>
</ul>
</td>
</tr>
</tbody>
</table>
<h4>Maintenance</h4>
<p><strong>Battery Replacement</strong></p>
<p>The 45158 has a low battery indicator (battery symbol). Important: Turn the meter off before opening the battery compartment. Using a coin, turn the battery compartment cover CLOCKWISE to remove it. Once opened, observe the position of the battery, placing the new one in the same position. Secure the battery compartment cover and dispose of the lithium battery in accordance with local, state, or national disposal codes.</p>
<p>All EU users are legally bound by the Battery Ordinance to return all used batteries to community collection points or wherever batteries / accumulators are sold.<br />
Disposal in household trash or refuse is prohibited.<br />
<strong><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/12-282.webp" /> Disposal:</strong> Follow the valid legal stipulations in respect of the disposal of the device at the end of its lifecycle.</p>
<p><strong>Other Battery Safety Reminders</strong></p>
<ul>
<li>Never dispose of batteries in a fire. Batteries may explode or leak.</li>
<li>Never mix battery types. Always install new batteries of the same type.</li>
</ul>
<p><strong>Impeller Replacement</strong></p>
<ul>
<li>Remove the set screw next to the impeller assembly (on the rear of the meter).</li>
<li>Twist the impeller assembly counter-clockwise to the OPEN position and remove it.</li>
<li>Install impeller by inserting &amp; twisting the new impeller assembly clockwise</li>
<li>Tighten the set screw.</li>
</ul>
<h4>CFM Measurements</h4>
<p>Measure the area of the duct using the diagrams below for rectangular and circular ducts (If the duct measurements are made in inches, divide the inches by 144 to get the area in square feet). Plug the area value (in square feet) in the cubic equations below. <strong>Note</strong> that the air velocity must be plugged into the cubic equations also.</p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/3-552-300x148-1.webp" /><br />
<strong>A = w * h</strong><br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/4-518-300x296-1.webp" /><br />
<strong>A = πr²</strong></p>
<ul>
<li><strong>CFM (ft³/min)</strong> = Air Velocity (ft/min) x Area (ft²)</li>
<li><strong>CMM (m³/min)</strong> = Air Velocity (m/sec) x Area (m²) x 60</li>
</ul>
<h4>Warranty</h4>
<h5>Two-year Warranty</h5>
<p>FLIR Systems, Inc. warrants this Extech brand instrument to be free of defects in parts and workmanship for two years from date of shipment (a six-month limited warranty applies to sensors and cables). To view the full warranty text please visit: <a href="http://www.extech.com/support/warranties" target="_blank" rel="noopener">http://www.extech.com/support/warranties</a>.</p>
<h4>Calibration and Repair Services</h4>
<p>FLIR Systems, Inc. offers calibration and repair services for the Extech brand products we sell. We offer NIST traceable calibration for most of our products. Contact us for information on calibration and repair availability, refer to the contact information below. Annual calibrations should be performed to verify meter performance and accuracy. Product specifications are subject to change without notice. Please visit our website for the most up-to-date product information:<a href="http://www.extech.com/" target="_blank" rel="noopener"> www.extech.com</a></p>
<h4>Contact Customer Support</h4>
<p><strong>Customer Support Telephone List:</strong> <a href="https://support.flir.com/contact" target="_blank" rel="noopener">https://support.flir.com/contact</a><br />
<strong>Calibration, Repair, and Returns:</strong> <a href="mailto:repair@extech.com">repair@extech.com</a><br />
<strong>Technical Support:</strong> <a href="https://support.flir.com/" target="_blank" rel="noopener">https://support.flir.com</a></p>
<p><strong>Copyright © 2013- 2020 FLIR Systems, Inc.<br />
</strong>All rights reserved including the right of reproduction in whole or in part in any form<br />
<a href="http://www.extech.com/" target="_blank" rel="noopener">www.extech.com</a><strong><br />
</strong></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/1-617-300x53-1.webp" /></p>
<form id="commentform" class="comment-form" action="https://manuals.plus/wp-comments-post.php" method="post" novalidate="">
<p class="form-submit">
</form>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>EXTECH Digital Multimeter EX410A Manual</title>
		<link>https://usemanuals.com/extech/ex410a-multimeter/</link>
		
		<dc:creator><![CDATA[ItsManual]]></dc:creator>
		<pubDate>Sat, 05 Aug 2023 17:38:54 +0000</pubDate>
				<category><![CDATA[EXTECH]]></category>
		<guid isPermaLink="false">https://usemanuals.com/?p=187191</guid>

					<description><![CDATA[Digital Multimeter MODEL EX410A USER MANUAL Introduction Congratulations on your purchase of the Extech EX410A Multimeter. This meter measures AC/DC  voltage, AC/DC Current, Resistance, Diode Test, and Continuity plus Thermocouple Temperature. This device is shipped fully tested and calibrated and, with proper use, will provide years of reliable service. Please visit our website (www.extech.com) to check for the latest version of this User Guide, Product Updates, additional user manual languages, and Customer Support. Safety International Safety Symbols This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual for further information. This symbol, adjacent to a terminal, indicates that, under normal use, hazardous voltages may be present Double insulation This WARNING symbol indicates a potentially hazardous situation, which if not avoided, could result in death or serious injury. This CAUTION symbol indicates a potentially hazardous situation, which if not avoided, may result in damage to the product This symbol advises the user that the terminal(s) so marked must not be connected to a circuit point at which the voltage with respect to earth ground exceeds (in this case) 600 VAC or VDC. CAUTION  Improper use of this meter can cause damage, shock, injury, or death. Read and understand this user manual before operating the meter. Always remove the test leads before replacing the battery or fuses.  Inspect the condition of the test leads and the meter itself for any damage before operating the meter. Repair or replace any damaged before use.  Use great care when making measurements if the voltages are greater than 25VAC rms or 35VDC. These voltages are considered a shock hazard. Warning! This is class A equipment. This equipment can cause interference to devices in the home; in this case, the operator can be required to carry out adequate measures to prevent interference.  Always discharge capacitors and remove power from the device under test before performing Diode, Resistance or Continuity tests. Voltage checks on electrical outlets can be difficult and misleading because of the uncertainty of connection to the recessed electrical contacts. Other means should be used to ensure that the terminals are not “live”.  If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. This device is not a toy and must not reach children’s hands. It contains hazardous objects as well as small parts that children could swallow. In case a child swallows any of the parts, please contact a physician immediately.  Do not leave batteries and packing material unattended; they can be dangerous for children.  In case the device is going to be unused for an extended period of time, remove the batteries to prevent them from draining.  Expired or damaged batteries can cause cauterization on contact with skin. Always use suitable hand protection.  See that the batteries are not short-circuited. Do not throw batteries into fire. OVERVOLTAGE CATEGORY III This meter meets the IEC 61010-1 (2010) 3 rd edition standard for OVERVOLTAGE CATEGORY III. Cat III meters are protected against overvoltage  transients in a fixed installation at the distribution level. Examples include switches in the fixed installation and some equipment for industrial use with permanent connection to the fixed installation. SAFETY INSTRUCTIONS This meter has been designed for safe use, but must be operated with caution. The rules listed below must be carefully followed for safe operation. NEVER apply a voltage or current to the meter that exceeds the specified maximum: Input Protection Limits Function Maximum Input V DC or V AC 600V DC/AC, 200Vrms on 200mV range mA DC 200mA 600V fast-acting fuse A DC 10A 600V fast-acting fuse (30 seconds max every 15 minutes) Ohms, Continuity 250Vrms for 15sec max USE EXTREME CAUTION when working with high voltages. DO NOT measure voltage if the voltage on the “COM” input jack exceeds 600V above earth ground. NEVER connect the meter leads across a voltage source while the function switch is in the current, resistance, or diode mode. Doing so can damage the meter. ALWAYS discharge filter capacitors in power supplies and disconnect the power when making resistance or diode tests. ALWAYS turn off the power and disconnect the test leads before opening the covers to replace the fuse or battery. NEVER operate the meter unless the back cover and the battery cover is in place and fastened securely. Description Rubber holster (must be removed to access battery2. 2000 count LCD display °F button for temperature measurements °C button for temperature measurements Function switch mA, uA and A input jacks COM input jack Positive input jack Battery check button Hold button (freezes displayed reading) LCD backlight button Note: Tilt stand, test lead holders, and battery compartment are on the rear of the unit. Symbols and Annunciators Continuity Diode test Battery status Test lead connection error Display hold Degrees Fahrenheit Degrees Celsius Operating Instructions WARNING: Risk of electrocution. High-voltage circuits, both AC and DC, are very dangerous and should be measured with great care. ALWAYS turn the function switch to the OFF position when the meter is not in use.  If “1” appears in the display during a measurement, the value exceeds the range you have selected. Change to a higher range. NOTE: On some low AC and DC voltage ranges, with the test leads not connected to a device, the display may show a random, changing reading. This is normal and is caused by the high input sensitivity. The reading will stabilize and give a proper measurement when connected to a circuit. DC VOLTAGE MEASUREMENTS CAUTION: Do not measure DC voltages if a motor on the circuit is being switched ON or OFF. Large voltage surges may occur that can damage the meter.  Set the function switch to the highest V DC ( ) position.  Insert the black test lead banana plug into the negative COM jack. Insert the red test lead banana plug into the positive V jack.  Touch the black test probe tip to the negative side of the circuit. Touch the red test probe tip to the positive side of the circuit.  Read the voltage in the display. Reset the function switch to successively lower V DC positions to obtain a higher resolution reading. If the polarity is reversed, the display will show (-) minus before the value. AC VOLTAGE MEASUREMENTS WARNING: Risk of Electrocution. The probe tips may not be long enough to contact the live parts inside some 240V outlets for appliances because the contacts are recessed deep in the outlets. As result, the reading may show 0 volts when the outlet actually has voltage on it. Make sure the probe tips are touching the metal contacts inside the outlet before assuming that no voltage is present. CAUTION: Do not measure AC voltages if a motor on the circuit is being switched ON or OFF. Large voltage surges may occur that can damage the meter. Set the function switch to the highest V AC ( ) position.  Insert the black test lead banana plug into the negative COM jack. Insert red test lead banana plug into the positive V jack.  Touch the black test probe tip to the neutral side of the circuit. Touch the red test probe tip to the “hot” side of the circuit. Read the voltage in the display. Reset the function switch to successively lower V AC positions to obtain a higher resolution reading. DC CURRENT MEASUREMENTS CAUTION: Do not make current measurements on the 10A scale for longer than 30 seconds. Exceeding 30 seconds may cause damage to the meter and/or the test leads.  Insert the black test lead banana plug into the negative COM jack.  For current measurements up to 200µA DC, set the function switch to the 200µA DC () position and insert the red test lead banana plug into the uA/mA jack. For current measurements up to 200mA DC, set the function switch to the 200mA DC position and insert the red test lead banana plug into the uA/(mA jack.  For current measurements up to 10A DC, set the function switch to the 10A DC range and insert the red test lead banana plug into the 10A jack.  Remove power from the circuit under test, then open up the circuit at the point where you wish to measure current.  Touch the black test probe tip to the negative side of the circuit. Touch the red test probe tip to the positive side of the circuit.  Apply power to the circuit. Read the current in the display. AC CURRENT MEASUREMENTS CAUTION: Do not make current measurements on the 10A scale for longer than 30 seconds. Exceeding 30 seconds may cause damage to the meter and/or the test leads. Insert the black test lead banana plug into the negative COM jack. For current measurements up to 200mA AC, set the function switch to the highest 200mA AC () position and insert the red test lead banana plug into the mA jack.  For current measurements up to 10A AC, set the function switch to the 10A AC range and insert the red test lead banana plug into the 10A jack. Remove power from the circuit under test, then open up the circuit at the point where you wish to measure current.  Touch the black test probe tip to the neutral side of the circuit. Touch the red test probe tip to the “hot” side of the circuit.  Apply power to the circuit.  Read the current in the display. RESISTANCE MEASUREMENTS WARNING: To avoid electric shock, disconnect power to the unit under test and discharge all capacitors before taking any resistance measurements. Remove the battery and unplug the line cords. Set the function switch to the highestΩ position.  Insert the black test lead banana plug into the negative COM jack. Insert the red test lead banana plug into the positive Ω jack.  Touch the test probe tips across the circuit or part under test. It is best to disconnect one side of the part under test so the rest of the circuit will not interfere with the resistance reading.  Read the resistance in the display and then set the function switch to the lowest Ω position that is greater than the actual or any anticipated resistance. CONTINUITY CHECK WARNING: To avoid electric shock, never measure continuity on circuits or wires that have voltage on them.  Set the function switch to the position. Insert the black lead banana plug into the negative COM jack. Insert the red test lead banana plug into the positive Ω jack.  Touch the test probe tips to the circuit or wire you wish to check. If the resistance is less than approximately 150Ω, the audible signal will sound. If the circuit is open, the display will indicate “1”. DIODE TEST Insert the black test lead banana plug into the negative COM jack and the red test lead banana plug into the positive diode jack. Turn the rotary switch to the position. Touch the test probes to the diode under test. Forward bias will typically indicate 400 to 1000. Reverse bias will indicate “1 ”. Shorted devices will indicate near 0 and the continuity beeper will sound. An open device will indicate “1 ” in both polarities. TEMPERATURE MEASUREMENTS Set the function switch to the TEMP position. Insert the Temperature Probe into the Temperature Socket, making sure to observe the correct polarity. Press the ºC or ºF button for the desired units. Touch the Temperature Probe head to the part whose temperature you wish to measure. Keep the probe touching the part under test until the reading stabilizes.  Read the temperature in the display. Note: The temperature probe is fitted with a type K mini connector. A mini connector to banana connector adaptor is supplied for connection to the input banana jacks. DISPLAY BACKLIGHT Press and hold the button to turn on the display backlight function. The backlight will automatically turn off after 15 seconds. BATTERY CHECK The CHECK function tests the condition of the 9V battery. Set the function switch to the 200VDC range and press the CHECK button. If the reading is less than 8.5, battery replacement is recommended. HOLD The hold function freezes the reading in the display. Press the HOLD key momentarily to activate or to exit the hold function. AUTO POWER OFF The auto-off feature will turn the meter off after 15 minutes. LOW BATTERY INDICATION If the icon appears in the display, the battery voltage is low and the battery should be replaced. WRONG CONNECTION INDICATION The icon will appear in the upper right corner of the display and the buzzer will sound whenever the positive test lead is inserted into the 10A or uA/mA input jack and a non-current (green) function is selected. If this occurs, turn the meter off and reinsert the test lead into the proper input jack for the function selected. Specifications Function Range Resolution Accuracy DC Voltage (V DC) 200mV 0.1mV ±(0.3% reading + 2 digits) 2V 0.001V ±(0.5% reading + 2 digits) 200V 0.1V 600V 1V ±(0.8% reading + 2 digits) AC Voltage (V AC) 50 to 400Hz 400Hz to 1 kHz 2V 0.001V ±(1.0% reading +6 digits ±(2.0% reading + 8 digits 200V 0.1V ±(1.5% reading +6 digits ±(2.5% reading +8 digits 600V 1V ±(2.0% reading +6 digits ±(3.0% reading +8 digits DC Current (A DC) 200pA 0.1pA ±(1.5% reading + 3 digits) 200mA 0.1mA 10A 0.01A ±(2.5% reading + 3 digits) AC Current (A AC) 50 to 400Hz 400Hz to 1kHz 200mA 0.1mA ±(1.8% reading +8 digits ±(2.5% reading +10 digits) 10A 0.01A ±(3.0% reading +8 digits) ±(3.5% reading +10 digits) Resistance 2000 0.10 ±(0.8% reading +4 digits) 20000 10 ±(0.8% reading +2 digits) 20k0 0.01K2 ±(1.0% reading +2 digits) 200k0 0.1k12 20M0 0.01M52 ±(2.0% reading +5 digits) Temperature -20 to 750°C 1°C ±(3.0% reading +3 digits) (meter only, probe accuracy not included) -4 to 1382°F 1°F NOTE: Accuracy specifications consist of two elements:  (% reading) – This is the accuracy of the measurement circuit.  (+ digits) – This is the accuracy of the analog to digital converter. NOTE: Accuracy is stated at 18°C to 28C (65°F to 83°F) and less than 75% RH. General Specifications Diode Test Test current of 1mA maximum, open circuit voltage 2.8V DC typical Continuity Check Audible signal when resistance is less than approximately 150Ω Input Impedance 10M 10M Ω AC Response Average responding ACV Bandwidth 50Hz to 1kHz DCA voltage drop 200mV Display 3 ½ digit, 2000 count LCD, 0.9” digits Auto-Power Off Meter switches OFF after 15 minutes (approximately) of inactivity Overrange indication “1” is displayed Polarity Automatic (no indication for positive polarity); Minus (-) sign for negative polarity. Measurement Rate 2 times per second, nominal Low Battery Indication “ ” is displayed if battery voltage drops below operating voltage Battery One 9 volts (NEDA 1604) battery Fuses mA, µA ranges; 0.2A/600V fast blow A range; 10A/600V ceramic fast blow Operating Temperature 5ºC to 40ºC (41ºF to 104ºF) Storage Temperature -20ºC to 60ºC (-4ºF to 140ºF) Operating Humidity Max 80% up to 31ºC (87ºF) decreasing linearly to 50% at 40ºC (104ºF) Storage Humidity &#60;80% Operating Altitude 2000 meters (7000ft.) maximum Weight 342g (0.753lb) (includes holster) Size 187 x 81 x 50mm (7.36” x 3.2” x 2.0”) (includes holster) Safety For indoor use and in accordance with the requirements for double insulation to: EN61010-1 (2010) 3rd edition Overvoltage Category III 600V, Pollution Degree 2. Maintenance WARNING: To avoid electrical shock, disconnect the meter from any circuit, remove the test leads from the input terminals, and turn OFF the meter before opening the case. Do not operate the meter with an open case. This MultiMeter is designed to provide years of dependable service if the following care instructions are performed: KEEP THE METER DRY. If it gets wet, wipe it off.  USE AND STORE THE METER IN NORMAL TEMPERATURES. Temperature extremes can shorten the life of the electronic parts and distort or melt plastic parts. HANDLE THE METER GENTLY AND CAREFULLY. Dropping it can damage the electronic parts or the case. KEEP THE METER CLEAN. Wipe the case occasionally with a damp cloth. DO NOT use chemicals, cleaning solvents, or detergents.  USE ONLY FRESH BATTERIES OF THE RECOMMENDED SIZE AND TYPE. Remove old or weak batteries so they do not leak and damage the unit.  IF THE METER IS TO BE STORED FOR A LONG PERIOD OF TIME, the batteries should be removed to prevent damage to the unit. Battery Replacement Remove the Phillips head screw that secures the rear battery door Open the battery compartment Replace the 9V battery Secure the battery compartment Never dispose of used batteries or rechargeable batteries in household waste. As consumers, users are legally required to take used batteries to appropriate collection sites, the retail store where the batteries were purchased, or wherever batteries are sold. Disposal: Do not dispose of this instrument in household waste. The user is obligated to take end-of-life devices to a designated collection point for the disposal of electrical and electronic equipment. Other Battery Safety Reminders Never dispose of batteries in a fire. Batteries may explode or leak. Never mix battery types. Always install new batteries of the same type. WARNING: To avoid electric shock, do not operate the meter until the battery cover is in place and fastened securely. NOTE: If the meter does not work properly, check the status of the fuses and batteries and ensuring proper insertion. REPLACING THE FUSES WARNING: To avoid electrical shock, disconnect the meter from any circuit, remove the test leads from the input terminals, and turn OFF the meter before opening the case. Do not operate the meter with an open case.  Disconnect the test leads from the meter.  Remove the protective rubber holster. Remove the battery cover (two “B” screws) and the battery.  Remove the four “A” screws securing the rear cover. Lift the center circuit board straight up from the connectors to gain access to the fuse holders.  Gently remove the old fuse and install the new fuse into the holder.  Always use a fuse of the proper size and value (0.2A/600V fast blow (5x20mm) for the 200mA range, 10A/600V fast blow (6.3x32mm) for the 10A range). Align the centerboard with the connectors and gently press into place.  Replace and secure the rear cover, battery, and battery cover. WARNING: To avoid electric shock, do not operate your meter until the fuse cover is in place and fastened securely. Copyright © 2013‐2016 FLIR Systems, Inc.  All rights  reserved  including  the  right  of  reproduction  in whole or in part  in any  form ISO‐9001 Certified  www.extech.com  [...]<p><a class="btn btn-secondary understrap-read-more-link" href="https://usemanuals.com/extech/ex410a-multimeter/">Read More...</a></p>]]></description>
										<content:encoded><![CDATA[<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/EXTECH-logo.webp" /></p>
<p><strong>Digital Multimeter<br />
</strong><strong>MODEL EX410A</strong></p>
<p><strong>USER MANUAL</strong></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/EXTECH-Digital-Multimeter.webp" /></p>
<h4><strong>Introduction</strong></h4>
<p>Congratulations on your purchase of the Extech EX410A Multimeter. This meter measures AC/DC  voltage, AC/DC Current, Resistance, Diode Test, and Continuity plus Thermocouple Temperature. This device is shipped fully tested and calibrated and, with proper use, will provide years of reliable service. Please visit our website (<a href="http://www.extech.com/" target="_blank" rel="noopener">www.extech.com</a>) to check for the latest version of this User Guide, Product Updates, additional user manual languages, and Customer Support.</p>
<h4><strong>Safety</strong></h4>
<p><strong>International Safety Symbols</strong></p>
<table width="1067">
<tbody>
<tr>
<td width="64"><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/warning-icon-14.webp" /></td>
<td width="112">This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual for further information.</td>
</tr>
<tr>
<td><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/warning-icon1.webp" /></td>
<td>This symbol, adjacent to a terminal, indicates that, under normal use, hazardous voltages may be present</td>
</tr>
<tr>
<td><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/Double-insulation-1.webp" /><a id="set-post-thumbnail" class="thickbox" href="https://manuals.plus/wp-admin/media-upload.php?post_id=399923&amp;type=image&amp;TB_iframe=1" aria-describedby="set-post-thumbnail-desc" target="_blank" rel="noopener"></a></td>
<td>Double insulation</td>
</tr>
<tr>
<td><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/warning-icon2.webp" /></td>
<td>This WARNING symbol indicates a potentially hazardous situation, which if not avoided, could result in death or serious injury.</td>
</tr>
<tr>
<td><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/caution-icon.webp" /><a id="set-post-thumbnail" class="thickbox" href="https://manuals.plus/wp-admin/media-upload.php?post_id=399923&amp;type=image&amp;TB_iframe=1" aria-describedby="set-post-thumbnail-desc" target="_blank" rel="noopener"></a></td>
<td>This CAUTION symbol indicates a potentially hazardous situation, which if not<br />
avoided, may result in damage to the product</td>
</tr>
<tr>
<td><img decoding="async" class="attachment-post-thumbnail size-post-thumbnail aligncenter ezlazyloaded" src="images/9.webp" alt="advice samble" width="123" height="102" data-ezsrc="https://manuals.plus/wp-content/uploads/2021/08/advice-samble.jpg?ezimgfmt=rs:123x102/rscb1/ng:webp/ngcb1" /></td>
<td>This symbol advises the user that the terminal(s) so marked must not be<br />
connected to a circuit point at which the voltage with respect to earth ground exceeds (in this case) 600 VAC or VDC.</td>
</tr>
</tbody>
</table>
<p><strong>CAUTION</strong></p>
<ul>
<li> Improper use of this meter can cause damage, shock, injury, or death. Read and understand this user manual before operating the meter.</li>
<li>Always remove the test leads before replacing the battery or fuses.</li>
<li> Inspect the condition of the test leads and the meter itself for any damage before operating the meter. Repair or replace any damaged before use.</li>
<li> Use great care when making measurements if the voltages are greater than 25VAC rms or 35VDC. These voltages are considered a shock hazard.</li>
<li>Warning! This is class A equipment. This equipment can cause interference to devices in the home; in this case, the operator can be required to carry out adequate measures to prevent interference.</li>
<li> Always discharge capacitors and remove power from the device under test before performing Diode, Resistance or Continuity tests.</li>
<li>Voltage checks on electrical outlets can be difficult and misleading because of the uncertainty of connection to the recessed electrical contacts. Other means should be used to ensure that the terminals are not “live”.</li>
<li> If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.</li>
<li>This device is not a toy and must not reach children’s hands. It contains hazardous objects as well as small parts that children could swallow. In case a child swallows any of the parts, please contact a physician immediately.</li>
<li> Do not leave batteries and packing material unattended; they can be dangerous for children.</li>
<li> In case the device is going to be unused for an extended period of time, remove the batteries to prevent them from draining.</li>
<li> Expired or damaged batteries can cause cauterization on contact with skin. Always use suitable hand protection.</li>
<li> See that the batteries are not short-circuited. Do not throw batteries into fire.</li>
</ul>
<p><strong>OVERVOLTAGE CATEGORY III</strong><br />
This meter meets the IEC 61010-1 (2010) 3 rd edition standard for OVERVOLTAGE CATEGORY III. Cat III meters are protected against overvoltage  transients in a fixed installation at the distribution level. Examples include switches in the fixed installation and some equipment for industrial use with permanent connection to the fixed installation.<br />
<strong>SAFETY INSTRUCTIONS</strong><br />
This meter has been designed for safe use, but must be operated with caution. The rules listed below must be carefully followed for safe operation.</p>
<ol>
<li><strong>NEVER</strong> apply a voltage or current to the meter that exceeds the specified maximum:<br />
<table width="1100">
<tbody>
<tr>
<td colspan="2" width="964">Input Protection Limits</td>
</tr>
<tr>
<td width="313">Function</td>
<td width="651">Maximum Input</td>
</tr>
<tr>
<td width="313">V DC or V AC</td>
<td width="651">600V DC/AC, 200Vrms on 200mV range</td>
</tr>
<tr>
<td width="313">mA DC</td>
<td width="651">200mA 600V fast-acting fuse</td>
</tr>
<tr>
<td width="313">A DC</td>
<td width="651">10A 600V fast-acting fuse (30 seconds max every 15 minutes)</td>
</tr>
<tr>
<td width="313">Ohms, Continuity</td>
<td width="651">250Vrms for 15sec max</td>
</tr>
</tbody>
</table>
</li>
<li><strong>USE EXTREME CAUTION</strong> when working with high voltages.</li>
<li><strong>DO NOT</strong> measure voltage if the voltage on the “COM” input jack exceeds 600V above earth ground.</li>
<li><strong>NEVER</strong> connect the meter leads across a voltage source while the function switch is in the current, resistance, or diode mode. Doing so can damage the meter.</li>
<li><strong>ALWAYS</strong> discharge filter capacitors in power supplies and disconnect the power when making resistance or diode tests.</li>
<li><strong>ALWAYS</strong> turn off the power and disconnect the test leads before opening the covers to replace the fuse or battery.</li>
<li><strong>NEVER</strong> operate the meter unless the back cover and the battery cover is in place and fastened securely.</li>
</ol>
<h4><strong>Description</strong></h4>
<ol>
<li>Rubber holster (must be removed to access battery2. 2000 count LCD display</li>
<li>°F button for temperature measurements</li>
<li>°C button for temperature measurements</li>
<li>Function switch</li>
<li>mA, uA and A input jacks</li>
<li>COM input jack</li>
<li>Positive input jack</li>
<li>Battery check button</li>
<li>Hold button (freezes displayed reading)</li>
<li>LCD backlight button</li>
</ol>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/EXTECH-Digital-Multimeter-Description.webp" /></p>
<p><strong>Note:</strong> Tilt stand, test lead holders, and battery compartment are on the rear of the unit.</p>
<h4><strong>Symbols and Annunciators</strong></h4>
<table border="0" width="128" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td width="64" height="20"><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/n-icon.webp" /><a id="set-post-thumbnail" class="thickbox" href="https://manuals.plus/wp-admin/media-upload.php?post_id=399923&amp;type=image&amp;TB_iframe=1" aria-describedby="set-post-thumbnail-desc" target="_blank" rel="noopener"></a></td>
<td width="64">Continuity</td>
</tr>
<tr>
<td height="20"><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/Diode-test-icon.webp" /><a id="set-post-thumbnail" class="thickbox" href="https://manuals.plus/wp-admin/media-upload.php?post_id=399923&amp;type=image&amp;TB_iframe=1" aria-describedby="set-post-thumbnail-desc" target="_blank" rel="noopener"></a></td>
<td>Diode test</td>
</tr>
<tr>
<td height="40"><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/LOW-BATTERY-INDICATION.webp" /><a id="set-post-thumbnail" class="thickbox" href="https://manuals.plus/wp-admin/media-upload.php?post_id=399923&amp;type=image&amp;TB_iframe=1" aria-describedby="set-post-thumbnail-desc" target="_blank" rel="noopener"></a></td>
<td>Battery status</td>
</tr>
<tr>
<td height="20"><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/n-icon2.webp" /><a id="set-post-thumbnail" class="thickbox" href="https://manuals.plus/wp-admin/media-upload.php?post_id=399923&amp;type=image&amp;TB_iframe=1" aria-describedby="set-post-thumbnail-desc" target="_blank" rel="noopener"></a></td>
<td>Test lead connection error</td>
</tr>
<tr>
<td height="20"><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/Display-hold.webp" /><a id="set-post-thumbnail" class="thickbox" href="https://manuals.plus/wp-admin/media-upload.php?post_id=399923&amp;type=image&amp;TB_iframe=1" aria-describedby="set-post-thumbnail-desc" target="_blank" rel="noopener"></a></td>
<td>Display hold</td>
</tr>
<tr>
<td height="20"><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/Degrees.webp" /><a id="set-post-thumbnail" class="thickbox" href="https://manuals.plus/wp-admin/media-upload.php?post_id=399923&amp;type=image&amp;TB_iframe=1" aria-describedby="set-post-thumbnail-desc" target="_blank" rel="noopener"></a></td>
<td>Degrees Fahrenheit</td>
</tr>
<tr>
<td height="20"><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/Degrees-Celsius.webp" /><a id="set-post-thumbnail" class="thickbox" href="https://manuals.plus/wp-admin/media-upload.php?post_id=399923&amp;type=image&amp;TB_iframe=1" aria-describedby="set-post-thumbnail-desc" target="_blank" rel="noopener"></a></td>
<td>Degrees Celsius</td>
</tr>
</tbody>
</table>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/Symbols.webp" /><a id="set-post-thumbnail" class="thickbox" href="https://manuals.plus/wp-admin/media-upload.php?post_id=399923&amp;type=image&amp;TB_iframe=1" aria-describedby="set-post-thumbnail-desc" target="_blank" rel="noopener"></a></p>
<h4><strong>Operating Instructions</strong></h4>
<p><strong>WARNING</strong>: Risk of electrocution. High-voltage circuits, both AC and DC, are very dangerous and should be measured with great care.</p>
<ol>
<li>ALWAYS turn the function switch to the OFF position when the meter is not in use.</li>
<li> If “1” appears in the display during a measurement, the value exceeds the range you have selected. Change to a higher range.</li>
</ol>
<p><strong>NOTE:</strong> On some low AC and DC voltage ranges, with the test leads not connected to a device, the display may show a random, changing reading. This is normal and is caused by the high input sensitivity. The reading will stabilize and give a proper measurement when connected to a circuit.<br />
<strong>DC VOLTAGE MEASUREMENTS</strong><br />
<strong>CAUTION:</strong> Do not measure DC voltages if a motor on the circuit is being switched ON or OFF. Large voltage surges may occur that can damage the meter.</p>
<ol>
<li> Set the function switch to the highest V DC (<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/V-DC.webp" /> ) position.</li>
<li> Insert the black test lead banana plug into the negative <strong>COM</strong> jack. Insert the red test lead banana plug into the positive <strong>V</strong> jack.</li>
<li> Touch the black test probe tip to the negative side of the circuit. Touch the red test probe tip to the positive side of the circuit.</li>
<li> Read the voltage in the display. Reset the function switch to successively lower V DC positions to obtain a higher resolution reading. If the polarity is<br />
reversed, the display will show (-) minus before the value.</li>
</ol>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/EXTECH-Digital-Multimeter-DC-VOLTAGE-MEASUREMENTS.webp" /></p>
<p><strong>AC VOLTAGE MEASUREMENTS</strong><br />
<strong>WARNING</strong>: Risk of Electrocution. The probe tips may not be long enough to contact the live parts inside some 240V outlets for appliances because the contacts are recessed deep in the outlets. As result, the reading may show 0 volts when the outlet actually has voltage on it. Make sure the probe tips are touching the metal contacts inside the outlet before assuming that no voltage is present.</p>
<p><strong>CAUTION:</strong> Do not measure AC voltages if a motor on the circuit is being switched ON or OFF.<br />
Large voltage surges may occur that can damage the meter.</p>
<ol>
<li>Set the function switch to the highest V AC ( <img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/V-AC.webp" /><a id="set-post-thumbnail" class="thickbox" href="https://manuals.plus/wp-admin/media-upload.php?post_id=399923&amp;type=image&amp;TB_iframe=1" aria-describedby="set-post-thumbnail-desc" target="_blank" rel="noopener"></a>) position.</li>
<li> Insert the black test lead banana plug into the negative <strong>COM</strong> jack. Insert red test lead banana plug into the positive <strong>V</strong> jack.</li>
<li> Touch the black test probe tip to the neutral side of the circuit. Touch the red test probe tip to the “hot” side of the circuit.</li>
<li>Read the voltage in the display. Reset the function switch to successively lower V AC positions to obtain a higher resolution reading.</li>
</ol>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/EXTECH-Digital-Multimeter-AC-VOLTAGE-MEASUREMENTS.webp" /></p>
<p><strong>DC CURRENT MEASUREMENTS</strong><br />
<strong>CAUTION:</strong> Do not make current measurements on the 10A scale for longer than 30 seconds. Exceeding 30 seconds may cause damage to the meter and/or the test leads.</p>
<ol>
<li> Insert the black test lead banana plug into the negative <strong>COM</strong> jack.</li>
<li> For current measurements up to 200µA DC, set the function switch to the 200µA DC (<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/V-DC.webp" />) position and insert the red test lead banana plug into the <strong>uA/mA</strong> jack.</li>
<li>For current measurements up to 200mA DC, set the function switch to the 200mA DC position and insert the red test lead banana plug into the <strong>uA/(mA</strong> jack.</li>
<li> For current measurements up to 10A DC, set the function switch to the 10A DC range and insert the red test lead banana plug into the<strong> 10A</strong> jack.</li>
<li> Remove power from the circuit under test, then open up the circuit at the point where you wish to measure current.</li>
<li> Touch the black test probe tip to the negative side of the circuit. Touch the red test probe tip to the positive side of the circuit.</li>
<li> Apply power to the circuit.</li>
<li>Read the current in the display.</li>
</ol>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/EXTECH-Digital-Multimeter-DC-VOLTAGE-MEASUREMENT1S.webp" /></p>
<p><strong>AC CURRENT MEASUREMENTS</strong><br />
<strong>CAUTION:</strong> Do not make current measurements on the 10A scale for longer than 30 seconds. Exceeding 30 seconds may cause damage to the meter and/or the test leads.</p>
<ol>
<li>Insert the black test lead banana plug into the negative <strong>COM</strong> jack.</li>
<li>For current measurements up to 200mA AC, set the function switch to the highest 200mA AC (<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/V-AC.webp" /><a id="set-post-thumbnail" class="thickbox" href="https://manuals.plus/wp-admin/media-upload.php?post_id=399923&amp;type=image&amp;TB_iframe=1" aria-describedby="set-post-thumbnail-desc" target="_blank" rel="noopener"></a>) position and insert the red test lead banana plug into the <strong>mA</strong> jack.</li>
<li> For current measurements up to 10A AC, set the function switch to the 10A AC range and insert the red test lead banana plug into the <strong>10A</strong> jack.</li>
<li>Remove power from the circuit under test, then open up the circuit at the point where you wish to measure current.</li>
<li> Touch the black test probe tip to the neutral side of the circuit. Touch the red test probe tip to the “hot” side of the circuit.</li>
<li> Apply power to the circuit.</li>
<li> Read the current in the display.</li>
</ol>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/EXTECH-Digital-Multimeter-AC-CURRENT-MEASUREMENTS.webp" /></p>
<p><strong>RESISTANCE MEASUREMENTS</strong><br />
<strong>WARNING:</strong> To avoid electric shock, disconnect power to the unit under test and discharge all capacitors before taking any resistance measurements. Remove the battery and unplug the line cords.</p>
<ol>
<li>Set the function switch to the highestΩ position.</li>
<li> Insert the black test lead banana plug into the negative <strong>COM</strong> jack. Insert the red test lead banana plug into the positive Ω jack.</li>
<li> Touch the test probe tips across the circuit or part under test. It is best to disconnect one side of the part under test so the rest of the circuit will not interfere with the resistance reading.</li>
<li> Read the resistance in the display and then set the function switch to the lowest Ω position that is greater than the actual or any anticipated<br />
resistance.</li>
</ol>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/EXTECH-Digital-Multimeter-RESISTANCE-MEASUREMENTS.webp" /></p>
<p><strong>CONTINUITY CHECK</strong><br />
<strong>WARNING:</strong> To avoid electric shock, never measure continuity on circuits or wires that have voltage on them.</p>
<ol>
<li> Set the function switch to the <img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/icon-6.webp" />position.</li>
<li>Insert the black lead banana plug into the negative <strong>COM</strong> jack. Insert the red test lead banana plug into the positive Ω jack.</li>
<li> Touch the test probe tips to the circuit or wire you wish to check.</li>
<li>If the resistance is less than approximately 150Ω, the audible signal will sound. If the circuit is open, the display will indicate “1”.</li>
</ol>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/EXTECH-Digital-Multimeter-CONTINUITY-CHECK.webp" /></p>
<p><strong>DIODE TEST</strong></p>
<ol>
<li>Insert the black test lead banana plug into the negative <strong>COM</strong> jack and the red test lead banana plug into the positive <strong>diode</strong> jack.</li>
<li>Turn the rotary switch to the<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/icon-6.webp" /> position.</li>
<li>Touch the test probes to the diode under test. Forward bias will typically indicate 400 to 1000. Reverse bias will indicate “<strong>1</strong> ”. Shorted devices will indicate near 0 and the continuity beeper will sound. An open device will indicate “<strong>1</strong> ” in both polarities.</li>
</ol>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/EXTECH-Digital-Multimeter-DIODE-TEST.webp" /></p>
<p><strong>TEMPERATURE MEASUREMENTS</strong></p>
<ol>
<li>Set the function switch to the TEMP position.</li>
<li>Insert the Temperature Probe into the Temperature Socket, making sure to observe the correct polarity.</li>
<li>Press the ºC or ºF button for the desired units.</li>
<li>Touch the Temperature Probe head to the part whose temperature you wish to measure. Keep the probe touching the part under test until the reading stabilizes.</li>
<li> Read the temperature in the display.</li>
</ol>
<p>Note: The temperature probe is fitted with a type K mini connector. A mini connector to banana connector adaptor is supplied for connection to the<br />
input banana jacks.</p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/EXTECH-Digital-Multimeter-TEMPERATURE-MEASUREMENTS.webp" /></p>
<p><strong>DISPLAY BACKLIGHT</strong><br />
Press and hold the <img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/backlight-function.webp" />button to turn on the display backlight function. The backlight will automatically turn off after 15 seconds.<br />
<strong>BATTERY CHECK</strong><br />
The<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/BATTERY-CHECK.webp" /> CHECK function tests the condition of the 9V battery. Set the function switch to the 200VDC range and press the CHECK button. If the reading is less than 8.5, battery replacement is recommended.<br />
<strong>HOLD</strong><br />
The hold function freezes the reading in the display. Press the HOLD key momentarily to activate or to exit the hold function.<br />
<strong>AUTO POWER OFF</strong><br />
The auto-off feature will turn the meter off after 15 minutes.<br />
<strong>LOW BATTERY INDICATION</strong><br />
If the <img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/Battery-status-icon.webp" /><a id="set-post-thumbnail" class="thickbox" href="https://manuals.plus/wp-admin/media-upload.php?post_id=399923&amp;type=image&amp;TB_iframe=1" aria-describedby="set-post-thumbnail-desc" target="_blank" rel="noopener"></a>icon appears in the display, the battery voltage is low and the battery should be replaced.<br />
<strong>WRONG CONNECTION INDICATION</strong><br />
The<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/wrong-connection.webp" /> icon will appear in the upper right corner of the display and the buzzer will sound whenever the positive test lead is inserted into the 10A or uA/mA input jack and a non-current (green) function is selected. If this occurs, turn the meter off and reinsert the test lead into the proper input jack for the function selected.</p>
<h4><strong>Specifications</strong></h4>
<table width="1300">
<tbody>
<tr>
<td width="207">Function</td>
<td width="132">Range</td>
<td colspan="3" width="158">Resolution</td>
<td colspan="3" width="501">Accuracy</td>
</tr>
<tr>
<td rowspan="4" width="207">DC Voltage (V DC)</td>
<td width="132">200mV</td>
<td colspan="3" width="158">0.1mV</td>
<td colspan="3" width="501">±(0.3% reading + 2 digits)</td>
</tr>
<tr>
<td width="132">2V</td>
<td colspan="3" width="158">0.001V</td>
<td colspan="3" rowspan="2" width="501">±(0.5% reading + 2 digits)</td>
</tr>
<tr>
<td width="132">200V</td>
<td colspan="3" width="158">0.1V</td>
</tr>
<tr>
<td width="132">600V</td>
<td colspan="3" width="158">1V</td>
<td colspan="3" width="501">±(0.8% reading + 2 digits)</td>
</tr>
<tr>
<td rowspan="4" width="207">AC Voltage (V AC)</td>
<td colspan="4" width="290"></td>
<td width="241">50 to 400Hz</td>
<td colspan="2" width="260">400Hz to 1 kHz</td>
</tr>
<tr>
<td colspan="2" width="137">2V</td>
<td colspan="2" width="153">0.001V</td>
<td width="241">±(1.0% reading +6 digits</td>
<td colspan="2" width="260">±(2.0% reading + 8 digits</td>
</tr>
<tr>
<td colspan="2" width="137">200V</td>
<td colspan="2" width="153">0.1V</td>
<td width="241">±(1.5% reading +6 digits</td>
<td colspan="2" width="260">±(2.5% reading +8 digits</td>
</tr>
<tr>
<td colspan="2" width="137">600V</td>
<td colspan="2" width="153">1V</td>
<td width="241">±(2.0% reading +6 digits</td>
<td colspan="2" width="260">±(3.0% reading +8 digits</td>
</tr>
<tr>
<td rowspan="3" width="207">DC Current (A DC)</td>
<td colspan="2" width="137">200pA</td>
<td colspan="2" width="153">0.1pA</td>
<td colspan="3" rowspan="2" width="501">±(1.5% reading + 3 digits)</td>
</tr>
<tr>
<td colspan="2" width="137">200mA</td>
<td colspan="2" width="153">0.1mA</td>
</tr>
<tr>
<td colspan="2" width="137">10A</td>
<td colspan="2" width="153">0.01A</td>
<td colspan="3" width="501">±(2.5% reading + 3 digits)</td>
</tr>
<tr>
<td rowspan="3" width="207">AC Current (A AC)</td>
<td colspan="4" width="290"></td>
<td colspan="2" width="252">50 to 400Hz</td>
<td width="249">400Hz to 1kHz</td>
</tr>
<tr>
<td colspan="3" width="142">200mA</td>
<td width="148">0.1mA</td>
<td colspan="2" width="252">±(1.8% reading +8 digits</td>
<td width="249">±(2.5% reading +10 digits)</td>
</tr>
<tr>
<td colspan="3" width="142">10A</td>
<td width="148">0.01A</td>
<td colspan="2" width="252">±(3.0% reading +8 digits)</td>
<td width="249">±(3.5% reading +10 digits)</td>
</tr>
<tr>
<td rowspan="5" width="207">Resistance</td>
<td colspan="3" width="142">2000</td>
<td width="148">0.10</td>
<td colspan="3" width="501">±(0.8% reading +4 digits)</td>
</tr>
<tr>
<td colspan="3" width="142">20000</td>
<td width="148">10</td>
<td colspan="3" width="501">±(0.8% reading +2 digits)</td>
</tr>
<tr>
<td colspan="3" width="142">20k0</td>
<td width="148">0.01K2</td>
<td colspan="3" rowspan="2" width="501">±(1.0% reading +2 digits)</td>
</tr>
<tr>
<td colspan="3" width="142">200k0</td>
<td width="148">0.1k12</td>
</tr>
<tr>
<td colspan="3" width="142">20M0</td>
<td width="148">0.01M52</td>
<td colspan="3" width="501">±(2.0% reading +5 digits)</td>
</tr>
<tr>
<td rowspan="2" width="207">Temperature</td>
<td colspan="3" width="142">-20 to 750°C</td>
<td width="148">1°C</td>
<td colspan="3" rowspan="2" width="501">±(3.0% reading +3 digits)<br />
(meter only, probe accuracy not included)</td>
</tr>
<tr>
<td colspan="3" width="142">-4 to 1382°F</td>
<td width="148">1°F</td>
</tr>
</tbody>
</table>
<p><strong>NOTE:</strong> Accuracy specifications consist of two elements:</p>
<ul>
<li> (% reading) – This is the accuracy of the measurement circuit.</li>
<li> (+ digits) – This is the accuracy of the analog to digital converter.</li>
</ul>
<p><strong>NOTE:</strong> Accuracy is stated at 18°C to 28C (65°F to 83°F) and less than 75% RH.</p>
<p>General Specifications</p>
<table width="1252">
<tbody>
<tr>
<td width="319">Diode Test</td>
<td width="319">Test current of 1mA maximum, open circuit voltage 2.8V DC typical</td>
</tr>
<tr>
<td width="319">Continuity Check</td>
<td width="319">Audible signal when resistance is less than approximately 150Ω</td>
</tr>
<tr>
<td width="319">Input Impedance 10M</td>
<td width="319">10M Ω</td>
</tr>
<tr>
<td width="319">AC Response</td>
<td width="319">Average responding</td>
</tr>
<tr>
<td width="319">ACV Bandwidth</td>
<td width="319">50Hz to 1kHz</td>
</tr>
<tr>
<td width="319">DCA voltage drop</td>
<td width="319">200mV</td>
</tr>
<tr>
<td width="319">Display</td>
<td width="319">3 ½ digit, 2000 count LCD, 0.9” digits</td>
</tr>
<tr>
<td width="319">Auto-Power Off</td>
<td width="319">Meter switches OFF after 15 minutes (approximately) of inactivity</td>
</tr>
<tr>
<td width="319">Overrange indication</td>
<td width="319">“1” is displayed</td>
</tr>
<tr>
<td width="319">Polarity</td>
<td width="319">Automatic (no indication for positive polarity); Minus (-) sign for negative<br />
polarity.</td>
</tr>
<tr>
<td width="319">Measurement Rate</td>
<td width="319">2 times per second, nominal</td>
</tr>
<tr>
<td width="319">Low Battery Indication</td>
<td width="319">“ <img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/Battery-status-icon.webp" /><a id="set-post-thumbnail" class="thickbox" href="https://manuals.plus/wp-admin/media-upload.php?post_id=399923&amp;type=image&amp;TB_iframe=1" aria-describedby="set-post-thumbnail-desc" target="_blank" rel="noopener"></a>” is displayed if battery voltage drops below operating voltage</td>
</tr>
<tr>
<td width="319">Battery</td>
<td width="319">One 9 volts (NEDA 1604) battery</td>
</tr>
<tr>
<td width="319">Fuses</td>
<td width="319">mA, µA ranges; 0.2A/600V fast blow<br />
A range; 10A/600V ceramic fast blow</td>
</tr>
<tr>
<td width="319">Operating Temperature</td>
<td width="319">5ºC to 40ºC (41ºF to 104ºF)</td>
</tr>
<tr>
<td width="319">Storage Temperature</td>
<td width="319">-20ºC to 60ºC (-4ºF to 140ºF)</td>
</tr>
<tr>
<td width="319">Operating Humidity</td>
<td width="319">Max 80% up to 31ºC (87ºF) decreasing linearly to 50% at 40ºC (104ºF)</td>
</tr>
<tr>
<td width="319">Storage Humidity</td>
<td width="319">&lt;80%</td>
</tr>
<tr>
<td width="319">Operating Altitude</td>
<td width="319">2000 meters (7000ft.) maximum</td>
</tr>
<tr>
<td width="319">Weight</td>
<td width="319">342g (0.753lb) (includes holster)</td>
</tr>
<tr>
<td width="319">Size</td>
<td width="319">187 x 81 x 50mm (7.36” x 3.2” x 2.0”) (includes holster)</td>
</tr>
<tr>
<td width="319">Safety</td>
<td width="319">For indoor use and in accordance with the requirements for double<br />
insulation to: EN61010-1 (2010) 3rd edition Overvoltage Category III<br />
600V, Pollution Degree 2.</td>
</tr>
</tbody>
</table>
<h4><strong>Maintenance</strong></h4>
<p><strong>WARNING:</strong> To avoid electrical shock, disconnect the meter from any circuit, remove the test leads from the input terminals, and turn OFF the meter before opening the case. Do not operate the meter with an open case.</p>
<p>This MultiMeter is designed to provide years of dependable service if the following care instructions are performed:</p>
<ol>
<li><strong>KEEP THE METER DRY.</strong> If it gets wet, wipe it off.</li>
<li><strong> USE AND STORE THE METER IN NORMAL TEMPERATURES</strong>. Temperature extremes can shorten the life of the electronic parts and distort or melt plastic parts.</li>
<li><strong>HANDLE THE METER GENTLY AND CAREFULLY.</strong> Dropping it can damage the electronic parts or the case.</li>
<li><strong>KEEP THE METER CLEAN.</strong> Wipe the case occasionally with a damp cloth. DO NOT use chemicals, cleaning solvents, or detergents.</li>
<li><strong> USE ONLY FRESH BATTERIES OF THE RECOMMENDED SIZE AND TYPE</strong>. Remove old or weak batteries so they do not leak and damage the unit.</li>
<li><strong> IF THE METER IS TO BE STORED FOR A LONG PERIOD OF TIME,</strong> the batteries should be removed to prevent damage to the unit.</li>
</ol>
<p><strong>Battery Replacement</strong></p>
<ol>
<li>Remove the Phillips head screw that secures the rear battery door</li>
<li>Open the battery compartment</li>
<li>Replace the 9V battery</li>
<li>Secure the battery compartment</li>
</ol>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/disposal.webp" /><a id="set-post-thumbnail" class="thickbox" href="https://manuals.plus/wp-admin/media-upload.php?post_id=399923&amp;type=image&amp;TB_iframe=1" aria-describedby="set-post-thumbnail-desc" target="_blank" rel="noopener"></a>Never dispose of used batteries or rechargeable batteries in household waste. As consumers, users are legally required to take used batteries to appropriate collection sites, the retail store where the batteries were purchased, or wherever batteries are sold.<br />
<strong>Disposal:</strong> Do not dispose of this instrument in household waste. The user is obligated to take end-of-life devices to a designated collection point for the disposal of electrical and electronic equipment.<br />
<strong>Other Battery Safety Reminders</strong></p>
<ul>
<li>Never dispose of batteries in a fire. Batteries may explode or leak.</li>
<li>Never mix battery types. Always install new batteries of the same type.</li>
</ul>
<p><strong>WARNING:</strong> To avoid electric shock, do not operate the meter until the battery cover is in place and<br />
fastened securely.<br />
<strong>NOTE:</strong> If the meter does not work properly, check the status of the fuses and batteries and ensuring proper insertion.</p>
<p><strong>REPLACING THE FUSES</strong><br />
<strong>WARNING:</strong> To avoid electrical shock, disconnect the meter from any circuit, remove the test leads from the input terminals, and turn OFF the meter before opening the case. Do not operate the meter with an open case.</p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/EXTECH-Digital-Multimeter-REPLACING-THE-FUSES.webp" /></p>
<ol>
<li> Disconnect the test leads from the meter.</li>
<li> Remove the protective rubber holster.</li>
<li>Remove the battery cover (two “B” screws) and the battery.</li>
<li> Remove the four “A” screws securing the rear cover.</li>
<li>Lift the center circuit board straight up from the connectors to gain access to the fuse holders.</li>
<li> Gently remove the old fuse and install the new fuse into the holder.</li>
<li> Always use a fuse of the proper size and value (0.2A/600V fast blow (5x20mm) for the 200mA range, 10A/600V fast blow (6.3x32mm) for the 10A range).</li>
<li>Align the centerboard with the connectors and gently press into place.</li>
<li> Replace and secure the rear cover, battery, and battery cover.</li>
</ol>
<p><strong>WARNING:</strong> To avoid electric shock, do not operate your meter until the fuse cover is in place and fastened securely.</p>
<p><strong>Copyright © 2013‐2016 FLIR Systems, Inc. </strong><br />
All rights  reserved  including  the  right  of  reproduction  in whole or in part  in any  form<br />
<strong>ISO‐9001 Certified </strong><br />
<a href="http://www.extech.com/" target="_blank" rel="noopener">www.extech.com </a></p>
<form id="commentform" class="comment-form" action="https://manuals.plus/wp-comments-post.php" method="post" novalidate="">
<p class="form-submit">
</form>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>

<!--
Performance optimized by W3 Total Cache. Learn more: https://www.boldgrid.com/w3-total-cache/

Page Caching using Disk: Enhanced 

Served from: usemanuals.com @ 2026-06-03 07:17:10 by W3 Total Cache
-->