<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>enocean &#8211; UseManuals</title>
	<atom:link href="http://usemanuals.com/enocean/feed/" rel="self" type="application/rss+xml" />
	<link>https://usemanuals.com</link>
	<description>Owner&#039;s manuals for all sorts of products</description>
	<lastBuildDate>Wed, 30 Aug 2023 17:59:43 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.7.2</generator>

<image>
	<url>https://usemanuals.com/wp-content/uploads/2025/02/favicon-32x32-2.png</url>
	<title>enocean &#8211; UseManuals</title>
	<link>https://usemanuals.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>enocean starter set N° 61 doorbell ES61-CH NASS Manual</title>
		<link>https://usemanuals.com/enocean/es61-ch-nass-doorbell/</link>
		
		<dc:creator><![CDATA[ItsManual]]></dc:creator>
		<pubDate>Wed, 30 Aug 2023 17:59:43 +0000</pubDate>
				<category><![CDATA[enocean]]></category>
		<guid isPermaLink="false">https://usemanuals.com/?p=211253</guid>

					<description><![CDATA[ES61-CH NASS Manual starter set N° 61 door bell EnOcean-Technologie (868 MHz) Typ / Type Art.-No./Item N° Designation ES61-CH NASS 9100 061 Preconfigured set consisting of wall-mounted transmitter WSNASS and switching actuator  miniS01, 1 closing  contact 16  A    230 V~,  supply voltage 230 V~ BRIEF INSTRUCTION Attach switching actuator according to plan  Mount wall-mounted transmitter  Done! FUNCTIONS S04 On-impulse X01 Gateway  Repeater FEATURES Plug&#38;Play – completely preconfigured set  The included wall-mounted transmitter is already programmed with function S04 On-impulse Pulse duration = 3 seconds Up to 50 transmitters can be programmed All functions can be programmed via E-Tool software Extremely compact design Extension input Thermal and overload protection  IP55 (wall-mounted transmitter) Bidirectional EnOcean radio technology 868.3 MHz EnOcean Equipment Profile (EEP) D2-01-00 GENERAL The Omnio actuators (receivers) are controlled by radio signals from the Omnio transmitters. Each transmitter can control an unlimited number of actuators within its transmission range. The radio transmitters are manually taught in and taught out to the actuator by a simple procedure. With the Omnio software E-Tool, all  Omnio actuators can be configured via radio even without manual access to the device. PRODUCT DESCRIPTION The Omnio starter set N° 61: doorbell is a preconfigured set for switching electrical loads. It can be installed without further configuration. The set consists of an Omnio switching actuator miniS01 and n Omnio wall-mounted transmitter S-CH102, which is already programmed with the function S04 On-impulse. Its non-isolated 230 V~ output is able to be controlled by up to 50 Omnio radio transmitters. Each transmitter can be programmed with the function S04 On-impulse. Via E-Tool software, the repeater can be activated as well. The extension input is preconfigured by default with the function S04  On-impulse. Bidirectional communication,  EEP 01-00. Suitable as a built-in unit. The wall-mounted transmitter is suitable for mounting in the wet and outdoor areas  (IP55). DISPLAY AND OPERATING ELEMENTS Terminals  L line voltage L 230 V~ N line voltage N 230V~ T extension input L’ relay output 230V~ Operating elements  LRN learn button LED LED red/green INSTALLATION This device is suitable for flush-mounted sockets installed indoors (dry rooms) through authorized personnel in compliance with the technical data and common safety regulations. This device needs to be protected by a 1 A circuit breaker. CONFIGURATION WITH E-TOOL Omnio actuators can be configured either manually on the device itself or by radio with the software E-Tool  Gold license. Please contact AWAG Elektrotechnik AG at www.awag.ch to obtain the license. The software and a detailed description of the Omnio system and all its functions can be found on the website www.omnio.ch. By default, remote commissioning is unlocked for half an hour at the power-on of the device. It can also be unlocked via a security code. The default value of the security code is A9081919. MANUAL CONFIGURATION The transmitter included in the set is already programmed. A maximum of 48 further transmitters can be programmed. PROGRAM TRANS MITTE R The programming model is indicated by a green blinking LED. At programming, the transmitter is assigned the function S04 On-impulse on the actuator. The transmitter must not be further than 5 m away from the actuator. Further functions can be programmed by E-Tool software, see also Table  1 FUNCTIONS. Enable programming mode by pressing the LRN  button The  LED blinks green. Press transmitter twice. The LED flickers green five times and then blinks.  Quit programming mode by pressing the LRN  button. The LED goes out. DELETE TRANS MITTER The deletion mode is indicated by a red blinking LED. Both sides of the rocker need to be deleted separately,  see also Table 2 DELETE TRANSMITTER.  Enable deletion mode by pressing the LRN button &#62; 7 s. The LED blinks red.  Press the upper side of the rocker twice. The LED flickers green five times and then blinks.  Press the lower side of the rocker twice. The LED flickers green five times and then blinks. Quit deletion mode by pressing the LRN button. The LED goes out. DELETE ALL TRANS MITTE RS Enable deletion mode by pressing the LRN button &#62; 7 s. The LED blinks red.  Press the LRN button 2 s. The LED flickers green five times and then goes out. FACTORY RESET Reset device parameters to default values, see also Table 2 DELETE TRANSMITTER. Attention: Programmed transmitters remain. Enable deletion de by pressing the LRN button &#62;  7s. The LED blinks red.  Enable reset mode by pressing the LRN button &#62; 7 s. The LED blinks quickly in the red. Press the LRN button 2 s. The  LED flickers green five times and then goes out. Table 1 FUNCTIONS SWITCH FUNCTIONS 2 s drücken press 2 s Taste 2x drücken press button 2x drücken press S04: On-impulse Doorbell function, default = 3 s. Off when button released 2 s drücken press 2 s UTE D2-01-00 drücken press X01 Gateway Program gateway Example: S04 On-impulse: LRN (2 s) – press button 2x – LRN Table 2 DELETE TRANSMITTERS 7 s drücken press 7 s Taste I 2x drücken Taste O 2x drücken press button I 2x press button O 2x drücken press Rocker Both buttons need to be deleted separately LRN-Taste 7 s drücken press LRN-button 7 s 2 s drücken press 2 s Delete all transmitter Factory reset Programmed transmitters remain Example:  Press LRN 7 s – press button I 2x – press button O 2x – press LRN Delete both sides of a rocker: Table 3 DEVICE PARAMETERS Default values are underlined START-UP BEHAVIOUR nur mit E-Tool konfigurierbar only configurable via E-Tool Off On Relay keeps state Pulse 1 s DEVICE COMMAND nur mit E-Tool konfigurierbar only configurable via E-Tool Reset energy counter 2 s drücken press 2 s – drücken press Start UTE teach-in sequence 7 s drücken press 7 s Start UTE teach-out sequence REPEATER In case of problems with the reception quality, the repeater function can be activated. The actuator will amplify the received radiograms and retransmit them. Only one device must be activated asa repeater within a radius of 5 meters. nur mit E-Tool konfigurierbar only configurable via E-Tool Off Level 1, repeats original radio telegrams Level 2, as level 1 and also retransmitted radio telegrams nur mit E-Tool konfigurierbar only configurable via E-Tool RPS rocker On: AI  Off: AO RPS push-button On: AI pushed Off: AI released 4BS EEP A5-11-01 VLD EEP D2-01-00 FEEDBACK TELEGRAM TYPE nur mit E-Tool konfigurierbar only configurable via E-Tool No feedback On change of state and every 3 min On change of state and every 30 s SECURITY CODE ALLOWED By default, the security code A9081919 can be used to enable remote access via E-Tool, so that the service technician has access to the actuator in the event of a fault. If this is not desired,this function must be switched off. nur mit E-Tool konfigurierbar only configurable via E-Tool Yes No MINIS01 TECHNICAL SPECIFICATIONS 230 V- / 50 Hz Voltage supply &#60; 0.5 W Standby power consumption 16 A External device protection 1 Schliesskontakt NO 230 V- 1 closing contact NO 230 V- Relay output 16 A Maximum continuous current 2.5 mm2 Screw terminals IP20 Protection class Lastabschaltung bei (Last &#62; 16 A LED blinkt rot, 30 s Erholungszeit load switch off at IL., &#62; 16 A LED flashes red, 30 s recovery time Overload protection Lastabschaltung bei TMCU &#62; 75 °C LED blinkt rot, 5 Minuten Erholungszeit load switch off at Tmcu &#62; 75 °C LED flashes red, 5 minutes recovery time Thermal protection Ja yes Extension input 50 Number of sensor memory locations EnOcean 868 MHz Technology EnOcean TCM 515 bidirektional / bidirectional Radio module D2-01-00 EnOcean Equipment Profile (EEP) -10…+40 °C / 5 … 85 % rH non condensing Environment PC ABS magenta 39.9 x 39.9 x 18.3 mm Housing 30 g Weight EN 60669-2-1 Standards LRN button Transmitter button (rocker, push-button etc.) Specialist required ATTENTION AWAG Elektrotechnik AG Sandbüelstrasse 2 CH-8604 Volketswil Tel. +41 44 908 19 19 Fax +41 44 908 19 99 info@awag.ch www.awag.ch 9100061.docx / 1876214 SW: miniS01_V200116 / 27.01.2020 Seite 4 / 4 [...]<p><a class="btn btn-secondary understrap-read-more-link" href="https://usemanuals.com/enocean/es61-ch-nass-doorbell/">Read More...</a></p>]]></description>
										<content:encoded><![CDATA[<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/enocean-LOGO.webp" /><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/12-119.webp" /><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/MNIO-LOGO.webp" /></p>
<p>ES61-CH NASS</p>
<p>Manual<br />
starter set N° 61 door bell<br />
EnOcean-Technologie (868 MHz)</p>
<table width="1381">
<tbody>
<tr>
<td width="90">Typ / Type</td>
<td width="120">Art.-No./Item N°</td>
<td width="390">Designation</td>
</tr>
<tr>
<td width="90">ES61-CH<br />
NASS</td>
<td width="120">9100 061</td>
<td width="390">Preconfigured set consisting of wall-mounted transmitter WSNASS and switching actuator  miniS01, 1 closing  contact 16  A    230 V~,  supply voltage 230 V~</td>
</tr>
</tbody>
</table>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/enocean-starter-set-NC2B0-61-doorbell-FEATURES.webp" /></p>
<h4><strong>BRIEF INSTRUCTION</strong></h4>
<ul>
<li>Attach switching actuator according to plan</li>
<li> Mount wall-mounted transmitter</li>
<li> Done!</li>
</ul>
<h4>FUNCTIONS</h4>
<ul>
<li>S04 On-impulse</li>
<li>X01 Gateway</li>
<li> Repeater</li>
</ul>
<h4><strong>FEATURES</strong></h4>
<ul>
<li>Plug&amp;Play – completely preconfigured set</li>
<li> The included wall-mounted transmitter is already programmed with function S04 On-impulse</li>
<li>Pulse duration = 3 seconds</li>
<li>Up to 50 transmitters can be programmed</li>
<li>All functions can be programmed via E-Tool software</li>
<li>Extremely compact design</li>
<li>Extension input</li>
<li>Thermal and overload protection</li>
<li> IP55 (wall-mounted transmitter)</li>
<li>Bidirectional EnOcean radio technology 868.3 MHz</li>
<li>EnOcean Equipment Profile (EEP) D2-01-00</li>
</ul>
<h4><strong>GENERAL</strong></h4>
<p>The Omnio actuators (receivers) are controlled by radio signals from the Omnio transmitters. Each transmitter can control an unlimited number of actuators within its transmission range. The radio transmitters are manually taught in and taught out to the actuator by a simple procedure. With the Omnio software E-Tool, all  Omnio actuators can be configured via radio even without manual access to the device.</p>
<h4><strong>PRODUCT DESCRIPTION</strong></h4>
<p><strong>The Omnio starter set N° 61:</strong> doorbell is a preconfigured set for switching electrical loads. It can be installed without further configuration. The set consists of an Omnio switching actuator miniS01 and n Omnio wall-mounted transmitter S-CH102, which is already programmed with the function S04 On-impulse. Its non-isolated 230 V~ output is able to be controlled by up to 50 Omnio radio transmitters.</p>
<p>Each transmitter can be programmed with the function S04 On-impulse. Via E-Tool software, the repeater can be activated as well. The extension input is preconfigured by default with the function S04  On-impulse. Bidirectional communication,  EEP 01-00. Suitable as a built-in unit. The wall-mounted transmitter is suitable for mounting in the wet and outdoor areas  (IP55).</p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/DISPLAY-AND-OPERATING-ELEMENTS.webp" /></p>
<h4><strong>DISPLAY AND OPERATING ELEMENTS</strong></h4>
<p>Terminals</p>
<ul>
<li> L line voltage L 230 V~</li>
<li>N line voltage N 230V~</li>
<li>T extension input</li>
<li>L’ relay output 230V~</li>
</ul>
<p><strong>Operating elements</strong></p>
<ul>
<li> LRN learn button</li>
<li>LED LED red/green</li>
</ul>
<h4><strong>INSTALLATION</strong></h4>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/enocean-starter-set-NC2B0-61-doorbellDas-Gerat.webp" /> This device is suitable for flush-mounted sockets installed indoors (dry rooms) through authorized personnel in compliance with the technical data and common safety regulations.<br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/ninebot-Electric-Scooter-with-LED-Light-Powerful-and-Portable-User-Manual-Warning-or-Caution-icon-1.webp" /> This device needs to be protected by a 1 A circuit breaker.</p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/enocean-starter-set-NC2B0-61-doorbell-INSTALLATION.webp" /></p>
<h4><strong>CONFIGURATION WITH E-TOOL</strong></h4>
<p>Omnio actuators can be configured either manually on the device itself or by radio with the software E-Tool  Gold license. Please contact AWAG Elektrotechnik AG at <a href="http://www.awag.ch/" target="_blank" rel="noopener">www.awag.ch</a> to obtain the license. The software and a detailed description of the Omnio system and all its functions can be found on the website <a href="http://www.omnio.ch/" target="_blank" rel="noopener">www.omnio.ch</a>. By default, remote commissioning is unlocked for half an hour at the power-on of the device. It can also be unlocked via a security code. The default value of the security code is <strong>A9081919.</strong></p>
<h4><strong>MANUAL CONFIGURATION</strong></h4>
<p>The transmitter included in the set is already programmed. A maximum of 48 further transmitters can be programmed.</p>
<h4><strong>PROGRAM TRANS MITTE R</strong></h4>
<p>The programming model is indicated by a green blinking LED. At programming, the transmitter is assigned the function S04 On-impulse on the actuator. The transmitter must not be further than 5 m away from the actuator. Further functions can be programmed by E-Tool software, see also Table  1 FUNCTIONS.</p>
<ol>
<li>Enable programming mode by pressing the LRN  button The  LED blinks green.</li>
<li>Press transmitter twice. The LED flickers green five times and then blinks.</li>
<li> Quit programming mode by pressing the LRN  button. The LED goes out.</li>
</ol>
<h4><strong>DELETE TRANS MITTER</strong></h4>
<p>The deletion mode is indicated by a red blinking LED. Both sides of the rocker need to be deleted separately,  see also Table 2 DELETE TRANSMITTER.</p>
<ol>
<li> Enable deletion mode by pressing the LRN button &gt; 7 s. The LED blinks red.</li>
<li> Press the upper side of the rocker twice. The LED flickers green five times and then blinks.</li>
<li> Press the lower side of the rocker twice. The LED flickers green five times and then blinks.</li>
<li>Quit deletion mode by pressing the LRN button. The LED goes out.</li>
</ol>
<p>DELETE ALL TRANS MITTE RS</p>
<ul>
<li>Enable deletion mode by pressing the LRN button &gt; 7 s. The LED blinks red.</li>
<li> Press the LRN button 2 s. The LED flickers green five times and then goes out.</li>
</ul>
<h4><strong>FACTORY RESET</strong></h4>
<p>Reset device parameters to default values, see also Table 2 DELETE TRANSMITTER.<br />
Attention: Programmed transmitters remain.</p>
<ol>
<li>Enable deletion de by pressing the LRN button &gt;  7s. The LED blinks red.</li>
<li> Enable reset mode by pressing the LRN button &gt; 7 s. The LED blinks quickly in the red.</li>
<li>Press the LRN button 2 s. The  LED flickers green five times and then goes out.</li>
</ol>
<table width="1411">
<tbody>
<tr>
<td width="144"><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/lrn.webp" /></td>
<td width="132"><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/SWITCH-FUNCTIONS.webp" /></td>
<td width="144"><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/lrn.webp" /></td>
<td width="204">Table 1 FUNCTIONS</p>
<p>SWITCH FUNCTIONS</td>
</tr>
<tr>
<td width="144">2 s drücken press 2 s</td>
<td width="132">Taste 2x drücken press button 2x</td>
<td width="144">drücken press</td>
<td width="204">S04: On-impulse Doorbell function, default = 3 s. Off when button released</td>
</tr>
<tr>
<td width="144">2 s drücken press 2 s</td>
<td width="132">UTE D2-01-00</td>
<td width="144">drücken press</td>
<td width="204">X01 Gateway Program gateway</td>
</tr>
</tbody>
</table>
<p>Example:<br />
S04 On-impulse: LRN (2 s) – press button 2x – LRN</p>
<table width="1489">
<tbody>
<tr>
<td width="102"><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/lrn.webp" /></td>
<td width="204"><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/nock-lrn.webp" /></td>
<td width="144"><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/lrn.webp" /></td>
<td width="174">Table 2</p>
<p>DELETE TRANSMITTERS</td>
</tr>
<tr>
<td width="102">7 s drücken<br />
press 7 s</td>
<td width="204">Taste I 2x drücken Taste O 2x drücken press button I 2x press button O 2x</td>
<td width="144">drücken press</td>
<td width="174">Rocker Both buttons need to be deleted separately</td>
</tr>
<tr>
<td width="102"></td>
<td width="204">LRN-Taste 7 s drücken press LRN-button 7 s</td>
<td width="144">2 s drücken press 2 s</td>
<td width="174">Delete all transmitter<br />
Factory reset Programmed transmitters remain</td>
</tr>
</tbody>
</table>
<p>Example:  Press LRN 7 s – press button I 2x – press button O 2x – press LRN<br />
Delete both sides of a rocker:</p>
<table width="1428">
<tbody>
<tr>
<td width="144"><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/lrn.webp" /></td>
<td width="144"><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/lrn.webp" /></td>
<td width="126"><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/lrn.webp" /></td>
<td width="210">Table 3<br />
DEVICE PARAMETERS</td>
</tr>
<tr>
<td colspan="4" width="623">Default values are underlined</td>
</tr>
<tr>
<td colspan="4" width="623"><strong>START-UP BEHAVIOUR</strong></td>
</tr>
<tr>
<td colspan="3" width="414">nur mit E-Tool konfigurierbar only configurable via E-Tool</td>
<td width="210">Off<br />
On<br />
Relay keeps state<br />
Pulse 1 s</td>
</tr>
<tr>
<td colspan="4" width="623">DEVICE COMMAND</td>
</tr>
<tr>
<td colspan="3" width="414">nur mit E-Tool konfigurierbar only configurable via E-Tool</td>
<td width="210">Reset energy counter</td>
</tr>
<tr>
<td width="144">2 s drücken press 2 s</td>
<td rowspan="2" width="144">–</td>
<td rowspan="2" width="126">drücken press</td>
<td width="210">Start UTE teach-in sequence</td>
</tr>
<tr>
<td width="144">7 s drücken press 7 s</td>
<td width="210">Start UTE teach-out sequence</td>
</tr>
<tr>
<td colspan="4" width="623"><strong>REPEATER</strong></p>
<p>In case of problems with the reception quality, the repeater function can be activated. The actuator will amplify the received radiograms and retransmit them. Only one device must be activated asa repeater within a radius of 5 meters.</td>
</tr>
<tr>
<td colspan="3" width="414">nur mit E-Tool konfigurierbar only configurable via E-Tool</td>
<td width="210">Off<br />
Level 1, repeats original radio telegrams<br />
Level 2, as level 1 and also retransmitted radio telegrams</td>
</tr>
<tr>
<td colspan="3" width="414">nur mit E-Tool konfigurierbar only configurable via E-Tool</td>
<td width="210">RPS rocker On: AI  Off: AO RPS push-button<br />
On: AI pushed<br />
Off: AI released<br />
4BS EEP A5-11-01<br />
VLD EEP D2-01-00</td>
</tr>
<tr>
<td colspan="4" width="623"><strong>FEEDBACK TELEGRAM TYPE</strong></td>
</tr>
<tr>
<td colspan="3" width="414">nur mit E-Tool konfigurierbar only configurable via E-Tool</td>
<td width="210">No feedback<br />
On change of state and every 3 min On change of state and every 30 s</td>
</tr>
<tr>
<td colspan="4" width="623"><strong>SECURITY CODE ALLOWED</strong></p>
<p>By default, the security code A9081919 can be used to enable remote access via E-Tool, so that the service technician has access to the actuator in the event of a fault. If this is not desired,this function must be switched off.</td>
</tr>
<tr>
<td colspan="3" width="414">nur mit E-Tool konfigurierbar only configurable via E-Tool</td>
<td width="210">Yes<br />
No</td>
</tr>
</tbody>
</table>
<table width="1411">
<tbody>
<tr>
<td width="374"><strong>MINIS01</strong></td>
<td width="363"><strong>TECHNICAL SPECIFICATIONS</strong></td>
</tr>
<tr>
<td width="374">230 V- / 50 Hz</td>
<td width="363">Voltage supply</td>
</tr>
<tr>
<td width="374">&lt; 0.5 W</td>
<td width="363">Standby power consumption</td>
</tr>
<tr>
<td width="374">16 A</td>
<td width="363">External device protection</td>
</tr>
<tr>
<td width="374">1 Schliesskontakt NO 230 V- 1 closing contact NO 230 V-</td>
<td width="363">Relay output</td>
</tr>
<tr>
<td width="374">16 A</td>
<td width="363">Maximum continuous current</td>
</tr>
<tr>
<td width="374">2.5 mm2</td>
<td width="363">Screw terminals</td>
</tr>
<tr>
<td width="374">IP20</td>
<td width="363">Protection class</td>
</tr>
<tr>
<td width="374">Lastabschaltung bei (Last &gt; 16 A<br />
LED blinkt rot, 30 s Erholungszeit<br />
load switch off at IL., &gt; 16 A<br />
LED flashes red, 30 s recovery time</td>
<td width="363">Overload protection</td>
</tr>
<tr>
<td width="374">Lastabschaltung bei TMCU &gt; 75 °C<br />
LED blinkt rot, 5 Minuten Erholungszeit<br />
load switch off at Tmcu &gt; 75 °C<br />
LED flashes red, 5 minutes recovery time</td>
<td width="363">Thermal protection</td>
</tr>
<tr>
<td width="374">Ja<br />
yes</td>
<td width="363">Extension input</td>
</tr>
<tr>
<td width="374">50</td>
<td width="363">Number of sensor memory locations</td>
</tr>
<tr>
<td width="374">EnOcean 868 MHz</td>
<td width="363">Technology</td>
</tr>
<tr>
<td width="374">EnOcean TCM 515 bidirektional / bidirectional</td>
<td width="363">Radio module</td>
</tr>
<tr>
<td width="374">D2-01-00</td>
<td width="363">EnOcean Equipment Profile (EEP)</td>
</tr>
<tr>
<td width="374">-10…+40 °C / 5 … 85 % rH non condensing</td>
<td width="363">Environment</td>
</tr>
<tr>
<td width="374">PC ABS magenta<br />
39.9 x 39.9 x 18.3 mm</td>
<td width="363">Housing</td>
</tr>
<tr>
<td width="374">30 g</td>
<td width="363">Weight</td>
</tr>
<tr>
<td width="374">EN 60669-2-1</td>
<td width="363">Standards</td>
</tr>
</tbody>
</table>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/lrn.webp" /> LRN button</p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/SWITCH-FUNCTIONS.webp" /> Transmitter button (rocker, push-button etc.)</p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/enocean-starter-set-NC2B0-61-doorbellDas-Gerat-1.webp" /> Specialist required</p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/ninebot-Electric-Scooter-with-LED-Light-Powerful-and-Portable-User-Manual-Warning-or-Caution-icon-1.webp" /> ATTENTION</p>
<p>AWAG Elektrotechnik AG Sandbüelstrasse 2 CH-8604 Volketswil<br />
Tel. +41 44 908 19 19 Fax +41 44 908 19 99 <a href="mailto:info@awag.ch">info@awag.ch</a> <a href="http://www.awag.ch/" target="_blank" rel="noopener">www.awag.ch</a></p>
<p>9100061.docx / 1876214<br />
SW: miniS01_V200116 / 27.01.2020 Seite 4 / 4</p>
<form id="commentform" class="comment-form" action="https://manuals.plus/wp-comments-post.php" method="post" novalidate="">
<p class="form-submit">
</form>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>

<!--
Performance optimized by W3 Total Cache. Learn more: https://www.boldgrid.com/w3-total-cache/

Page Caching using Disk: Enhanced 

Served from: usemanuals.com @ 2026-06-08 19:31:13 by W3 Total Cache
-->