<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>ELKAY &#8211; UseManuals</title>
	<atom:link href="http://usemanuals.com/elkay/feed/" rel="self" type="application/rss+xml" />
	<link>https://usemanuals.com</link>
	<description>Owner&#039;s manuals for all sorts of products</description>
	<lastBuildDate>Mon, 21 Aug 2023 16:42:33 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.7.2</generator>

<image>
	<url>https://usemanuals.com/wp-content/uploads/2025/02/favicon-32x32-2.png</url>
	<title>ELKAY &#8211; UseManuals</title>
	<link>https://usemanuals.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>ELKAY EZH2O Refrigerated Surface Mount Bottle Filling Station Manual</title>
		<link>https://usemanuals.com/elkay/ezh2o-filling-station/</link>
		
		<dc:creator><![CDATA[ItsManual]]></dc:creator>
		<pubDate>Mon, 17 Jul 2023 11:57:11 +0000</pubDate>
				<category><![CDATA[ELKAY]]></category>
		<guid isPermaLink="false">https://usemanuals.com/?p=163295</guid>

					<description><![CDATA[EZ8WSLSMC_1G EZ8WSSSMC_1G LZ8WSLSMC_1G LZ8WSSSMC_1G Elkay EZH2O Refrigerated Surface Mount Bottle Filling Station(s) series EZ8WS &#38; LZ8WS USE AND CARE GUIDE General Information  Use and Care Guide Read all instructions carefully and familiarize yourself with the various parts of this product. This manual contains step-by-step adjustment, and maintenance instructions for the EZ8WS and LZ8WS series bottle filling stations and cooler. Following carefully, these instructions will result in trouble-free use of this Elkay Manufacturing Company (Elkay) product. Any deviations, additions, and/or deletions from the described methods, without the prior written approval of Elkay, will void the warranty covering this product. Save these instructions for future reference WARNING To avoid product or property damage, personal injury, or even possible death, carefully read, understand, and follow all the instructions in this Use and Care guide before installing his product. Improper installation of this product could cause a dangerous situation that results in injury or death. Do not operate power tools unless you read and understand the instructions and warnings in this and all other applicable labels or manuals. Proper use of tools and the products described in this guide is your responsibility. Failure to follow these instructions could result in personal injuries, water damage, and other damage to floors, pipes, walls, and other portions of your building or home. Disclaimer The information contained in this Use and Care guide is given free of charge. It is based upon technical data which we believe to be reliable and is intended for use by persons having knowledge of this technical area at their own discretion and risk. Elkay assumes no responsibility for results obtained or damage incurred from the use of   this material either in whole or in part by the buyer. Serial Number Location Please use the serial number located on the underside of the water cooler shroud when contacting us with questions concerning the installation of this product.  Contact Information General Information Elkay Manufacturing Company 1333 Butterfield Road Suite 200 Downers Grove, IL 60515 Phone: 630.574.8484 Email: consumer@elkay.com Website: http://www.elkay.com USA/Canada Customer Care Phone: 800.476.4106 Email: CustCare@Elkay.com International Customer Care Phone: 630.575.4755 Email: IntlCare@Elkay.com Installation Services Phone: 800.952.8064 Email: installservice@elkay.com Website: http://www.elkay.com/contact-us/install Notice of Changes The information, specifications, and illustrations in this manual are based on the information that was available at the time this material was written and can change at any time. In keeping with our policy of continuous product improvement, Elkay reserves the right to change specifications without notice. Warranty This product is covered by a Limited Warranty and Elkay will not be held responsible for damage of any kind in connection with the installation of the product. Refer to the Elkay website http://www.elkay.com/warranty and click on Warranty for Drinking Water Products under the Info and Maintenance section (form 96993C). Safety Think Safety Before performing any work, read and understand the safety instructions in this manual. General The Elkay Manufacturing Company (Elkay) cannot anticipate every possible circumstance that might involve a potential hazard during the installation or maintenance of this product. The warnings and instructions in this Use and Care guide, therefore, are not all-inclusive. If a tool, installation procedure, or work method that is not specifically recommended by Elkay is used, you must be satisfied that it is safe for yourself and others. You should also make sure that the product will not be damaged by the methods you choose. Most work-related accidents are caused by failure to observe basic safety rules or precautions. An accident can often be avoided by recognizing potentially hazardous situations before an accident occurs. As you install and maintain this product, you must be alert to potential hazards. You should also have the necessary training, skills, and tools to perform any installation or maintenance procedure. Safety Alert Symbol This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death. This manual contains WARNINGS, CAUTIONS, NOTICES, SAFETY INSTRUCTIONS, and NOTES which must be followed to prevent the possibility of improper service, damage to the equipment, personal injury, or death. The following keywords call the reader’s attention to potential hazards. Hazards are identified by the “Safety Alert Symbol”  and followed by a signal word such as “WARNING” or “CAUTION”. WARNING  These warnings indicate a potentially hazardous situation that, if not avoided, could result in serious injury or death. Follow all instructions related to the installation and/or maintenance of this product (unit).  Personal Protection Be sure to use all personal protective equipment, such as sturdy safety glasses, work shoes, hearing protection, and gloves, whenever necessary, to ensure your own safety. To avoid eye injury, always wear protective glasses with side shields when using power tools. Also, make sure no one else can be injured by flying particles when using power tools. To prevent possible damage to your hearing, always wear ear protection, such as earmuffs or earplugs, when using power tools. This product is heavy and can cause bodily injury, due to its weight or if the unit is dropped. Use two people to lift the product when unpacking the unit or installing it onto the hanger brackets. Wear protective gloves during installation to protect against sharp edges from sheet metal components. Lifting Hazard To avoid personal injury, always use these proper lifting techniques and use two Use appropriate lifting devices to move the load.  Always use two people when lifting heavy or bulky cartons. DO NOT attempt to lift objects that are too heavy. Power Tool Hazard To prevent personal injury or possible death, always follow the electrical safety recommendations of the power tool’s manufacturer. Do not use power tools in an unsafe manner. Power tools should only be connected to a circuit protected by a ground-fault circuit interrupter (GFCI). If an extension cord is required, always use an OSHA-approved extension cord. Shock and Electrocution Hazards Failure to follow these instructions could result in severe burns, significant injuries, and even death. Water will conduct electric current to create a short circuit, resulting in injury or death. Never use electric power tools around water or wet floors/surfaces. Keep all liquids away from electrical cords and power tools. If an extension cord is required, always use an OSHA-approved cord. DO NOT create a short circuit between a source of electricity and a liquid by being in contact with both simultaneously Contacting live electrical wiring with power tools or hand tools can cause serious injury or death. Make sure all related circuit breakers are turned OFF. Test for live circuits or wiring inside any wall where installation of the product requires cutting into a wall. Prior to any maintenance, make sure the unit is unplugged and circuit breakers are turned OFF. Prior to installation, test for live circuits or wiring inside the wall before cutting or drilling into the wall. WARNING These cautions indicate a potentially hazardous situation that, if not avoided, may result in minor or moderate injury. Follow all instructions related to the installation and/or maintenance of this product. Tripping Hazard Personal injury can result from tripping over power cords, tools, or other installation items. DO NOT leave items laying around the work area. Cutting Hazard The installation of this product may require using power tools. Keep hands away from the cutting edge of any tool used in the installation of our product. Placing fingers in or around the cutting blades could result in serious personal injury. Changing the Factory Default Settings (Not Required for Installation) Accessing the Programming Button Remove the bottle filler top cover by removing the two screws using a 5/32” Allen wrench. Do not discard the screws, they are required for re-assembly. Locate the programming button at the top right side of the unit on the control board. Access the Programming Menu Depress the program button for approximately two seconds until the display changes, then release. The display will scroll through two messages. a. RST FLTR – Reset Filter Monitor (filtered units only). b. SETTINGS – System Setting Sub Menu. Depress the program button when the display reads SETTINGS. The display will scroll through four messages: • RNG SET – Range set for IR sensor. Default is 3. • UNIT TYP – Type of unit. Default is refrigerated. • FLT SIZE – Select filter capacity. Default is 3000 GAL. • RST BCNT – Reset bottle count (filtered units only). Push the button while the desired message is displayed. If the program button is not pushed, the messages will cycle three times before resetting back to run mode. Reset the Filter Monitor (Filtered Unit Only) Depress the program button when the display reads RST FLTR. Depress the program button when the display reads FLTR = and the display will change to FLTR = 0. The green LED on the bottle filler panel should now be illuminated indicating that the filter monitor has been reset. Change the Range Of The IR Sensor Depress the program button when the display reads RNG SET. The display will show the default RNG = 3. 1-10 is the range, 1 is closest to the sensor, 10 is farthest away. Depress the button again to change the value. When the desired range is selected, wait four seconds for the unit to default back to run mode. Test the bottle filler by placing a hand or a bottle in front of the sensor.  Change the Unit Type Depress the program button when the display reads UNIT TYP. The display will show the default REFRIG. Depress button to change to refrigerated if NONREFRIG is displayed. When the desired range is selected, wait four seconds for the unit to default back to run mode. Test the bottle filler by placing a  hand or a bottle in front of the sensor. Change the Filter Capacity (Filtered Unit Only) Depress the program button when the display reads FLT SIZE. The display will show the default 3000GAL. Depress the button again to change the value to 6000GAL. When the desired range is selected, wait four seconds for the unit to default back to run mode.  Resetting the Bottle Count Depress the program button when the display reads RST BCNT. The display will show the current value, e.g. 0033183. Depress the button again to change the value to 0. The display will show BTLCT = 0 for approximately 2 seconds and return to run mode showing 0000000 on the display board.  Resetting the Bottle Count 1. Depress the program button when the display reads RST BCNT. 2. The display will show the current value, e.g. 0033183. 3. Depress the button again to change the value to 0. The display will show BTLCT = 0 for approximately 2 seconds and return to run mode showing 0000000 on the display board. Note: Once the bottle count is reset to 0, there is no way to return to the previous count. Test the bottle filler by placing a hand or a bottle in front of the sensor and dispensing product until the bottle count changes to 1. Cleaning Instruction Stainless Steel General Cleaning: Use an ordinary mild detergent and soft cloth, rinse and towel dry. Steel soap pads should never be used; particles can adhere to a stainless steel basin surface and will eventually rust. Light scratches are normal for stainless steel basins; Over over time, they will blend into the uniform finish pattern.  Plastic Components General cleaning: Use an ordinary mild detergent and soft cloth, rinse and towel dry.  Wiping the surface clean to remove debris or build-up will not hurt the antimicrobial properties. Filter Cartridge Replacement for Filtered Units Only Remove the front cover of the cooler by removing two 5/16″ screws located on the bottom of the cooler. Shut the oﬀ water supply using the shut oﬀ valve. Turn the water shut oﬀ valve handle to the OFF position (clockwise). Note: This view may be different depending on the model and configuration. Activate the water dispenser with a water bottle to relieve pressure and access water in the waterline. Shut OFF power to the unit by unplugging. Locate the current filter on the left side of the cooler. Place a towel under the filter to absorb any water that leaks out of the filter when it is removed. Twist the filter counterclockwise until it is disengaged. Remove the filter and keep it upright; remove the towel. Drain the filter before disposing of it in a trash can. Remove the protective cap from the new filter.  Mark the current date on the filter label. Attach the filter to the filter head with the label facing outward by fi rmly inserting it into the head and by rotating the fi lter head clockwise, if required. Note: The filter label should be readable from the front of the filter during installation. Restore power back to the unit. Turn on the water supply. Verify proper dispensing by placing a cup or any object in front of sensor area and verifying water dispenses. Dispense at least two gallons of water to bleed oﬀ any trapped air from supply lines and fi ne carbon particles from the fi lter. Check all the lines and connections for water leaks. Repair connections if necessary. If there are no leaks and the unit is functioning correctly. Reinstall front panel with 5/16” screws. Note: Once power is applied to the bottle filler, the GREEN LED light should illuminate showing good filter status (if equipped with filter) along with the LCD Bottle Counter. GREEN: 0 – 80% of Filter Life or 0 – 11 Months (Whichever Comes First). YELLOW: 80 – 100% of Filter Life or 11 – 12 Months (Whichever Comes First). RED: 100% Plus of Filter Life or 12 Months (Whichever Comes First). Reset the filter status indicator: The programming button is located at the top right side of the unit on the control board. To access the program button, take oﬀ the top cover of the bottle filler by removing the two screws holding it in place. Remove the screws using a 5-32 inch Allen wrench (Do not discard the mounting screws; they will be needed to reinstall the top cover once programming is complete). Remove the top cover. To remove the cover, depress the program button when the display reads RST FLTR. Depress the program button when the display reads FLTR = and the display will change to FLTR = 0. The green LED on the bottle filler panel should now be illuminated indicating that the filter monitor has been reset.  Filter Reset is complete. Picture is Cooler Only Without Bottle Filler Note: Danger! Electric shock hazard. Disconnect power before serving unit. Fig 1: Cooler Top View (EZ8WS Shown) Fig 2: Cooler Front View Fig 3: Basin Cover Fig 4: Basin Assembly Kit Fig 5: Front View with Aerator Operation of Quick Connection Fitting  Fig 6: Poly Tube Quick Connect Fitting Fig 7: Filter and Filter Head FILTER PARTS LIST (See Fig 7: Filter and Filter Head) ITEM NO. PART NO. DESCRIPTION 1 2 51300C 0000000746 Filter Assy-3000 Gal Assy-Filter &#38; Bracket includes Fltr Head/Mtg Bkt/John Guest Ftgs/Screws Fig 8: 115V Wiring Diagram Cooler Parts List ITEM NO.  PART NO.  DESCRIPTION 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 – 28551C 36208C *36322C 0000000238 55996C 56092C 66703C 98773C 98775C 98776C 98777C 98778C 28525C 28528C 2000000075 2000000076 1000006133 See Filter Table Hanger Bracket Power Cord Compressor Serv. Pak EMIS70HHR Kit – Electricals /OL/Relay/Cvr Strainer (See “General Instructions”) Tubing – Poly (Cut To Length) Drier Kit – Cold Control/Screws Kit – Fan Motor Assy/Blade/Motor/Shroud/Nut Kit – Condenser/Drier Kit – Compr Mtg Hdwe/Grommets/Clips Studs Kit – Heat Exchanger/Drier Panel – Right Rear Panel – Left Rear Kit – Basin Cover Kit – Basin Assembly Panel – Front Cover Water Filter Kit (When Provided) Bottle Filler Parts List ITEM NO. PART NO. DESCRIPTION 18 19 20 21 22 98543C 98544C 1000004573 98546C 98547C Kit – Electrical Package Kit – IR Sensor Kit – Solenoid Valve Replacement Kit – Aerator ReplacementKit – Top Cover Replacement *Replace With Same Compressor Used in Original Assembly. Note: All correspondence pertaining to any of the above components for repair parts MUST include Model No. and Serial No., name and part number of replacement part. [...]<p><a class="btn btn-secondary understrap-read-more-link" href="https://usemanuals.com/elkay/ezh2o-filling-station/">Read More...</a></p>]]></description>
										<content:encoded><![CDATA[<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/ELKAY-logo-1-300x55-3.webp" /></p>
<p>EZ8WSLSMC_1G EZ8WSSSMC_1G LZ8WSLSMC_1G LZ8WSSSMC_1G<br />
Elkay EZH2O Refrigerated Surface<br />
Mount Bottle Filling Station(s)<br />
series EZ8WS &amp; LZ8WS</p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/ELKAY-EZH2O-Refrigerated-Surface-Mount-Bottle-Filling-Station-150x300-2.webp" /></p>
<p><strong>USE AND CARE GUIDE</strong></p>
<h4>General Information</h4>
<p><strong> Use and Care Guide</strong><br />
Read all instructions carefully and familiarize yourself with the various parts of this product. This manual contains step-by-step adjustment, and maintenance instructions for the EZ8WS and LZ8WS series bottle filling stations and cooler. Following carefully, these instructions will result in trouble-free use of this Elkay Manufacturing Company (Elkay) product. Any deviations, additions, and/or deletions from the described methods, without the prior written approval of Elkay, will void the warranty covering this product. <strong>Save these instructions for future reference</strong></p>
<p><img decoding="async" class="alignnone wp-image-1171681 ezlazyloaded" src="images/6.webp" alt="ELKAY EZH2O Refrigerated Surface Mount Bottle Filling Station - warning 1" width="48" height="46" data-ezsrc="https://manuals.plus/wp-content/uploads/2021/11/ELKAY-EZH2O-Refrigerated-Surface-Mount-Bottle-Filling-Station-warning-1.jpg?ezimgfmt=rs:48x46/rscb1/ng:webp/ngcb1" /><strong>WARNING</strong></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/ELKAY-EZH2O-Refrigerated-Surface-Mount-Bottle-Filling-Station-icon-1-1.webp" /> To avoid product or property damage, personal injury, or even possible death, carefully read, understand, and follow all the instructions in this Use and Care guide before installing his product. Improper installation of this product could cause a dangerous situation that results in injury or death. Do not operate power tools unless you read and understand the instructions and warnings in this and all other applicable labels or manuals. Proper use of tools and the products described in this guide is your responsibility. Failure to follow these instructions could result in personal injuries, water damage, and other damage to floors, pipes, walls, and other portions of your building or home.<br />
<strong>Disclaimer</strong><br />
The information contained in this Use and Care guide is given free of charge. It is based upon technical data which we believe to be reliable and is intended for use by persons having knowledge of this technical area at their own discretion and risk. Elkay assumes no responsibility for results obtained or damage incurred from the use of   this material either in whole or in part by the buyer.</p>
<p><strong>Serial Number Location</strong><br />
Please use the serial number located on the underside of the water cooler shroud when contacting us with questions concerning the installation of this product.</p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/ELKAY-EZH2O-Refrigerated-Surface-Mount-Bottle-Filling-Station-Number-Location-300x173-2.webp" /></p>
<p><strong> Contact Information</strong><br />
<strong>General Information</strong><br />
Elkay Manufacturing Company 1333 Butterfield Road Suite 200 Downers Grove, IL 60515<br />
Phone: 630.574.8484<br />
Email: <a href="mailto:consumer@elkay.com">consumer@elkay.com</a><br />
Website: <a href="http://www.elkay.com/" target="_blank" rel="noopener">http://www.elkay.com</a><br />
<strong>USA/Canada Customer Care</strong><br />
Phone: 800.476.4106<br />
Email: <a href="mailto:CustCare@Elkay.com">CustCare@Elkay.com</a><br />
<strong>International Customer Care</strong><br />
Phone: 630.575.4755<br />
Email: <a href="mailto:IntlCare@Elkay.com">IntlCare@Elkay.com</a><br />
<strong>Installation Services</strong><br />
Phone: 800.952.8064<br />
Email: <a href="mailto:installservice@elkay.com">installservice@elkay.com</a><br />
Website: <a href="http://www.elkay.com/contact-us/install" target="_blank" rel="noopener">http://www.elkay.com/contact-us/install</a></p>
<p><strong>Notice of Changes</strong><br />
The information, specifications, and illustrations in this manual are based on the information that was available at the time this material was written and can change at any time. In keeping with our policy of continuous product improvement, Elkay reserves the right to change specifications without notice.<br />
<strong>Warranty</strong><br />
This product is covered by a Limited Warranty and Elkay will not be held responsible for damage of any kind in connection with the installation of the product. Refer to the Elkay website <a href="http://www.elkay.com/warranty" target="_blank" rel="noopener">http://www.elkay.com/warranty</a> and click on Warranty for Drinking Water Products under the Info and Maintenance section (form 96993C).</p>
<h4>Safety</h4>
<p><strong><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/ELKAY-EZH2O-Refrigerated-Surface-Mount-Bottle-Filling-Station-icon-2-1.webp" />Think Safety</strong><br />
Before performing any work, read and understand the safety instructions in this manual.</p>
<p><strong>General</strong><br />
The Elkay Manufacturing Company (Elkay) cannot anticipate every possible circumstance that might involve a potential hazard during the installation or maintenance of this product. The warnings and instructions in this Use and Care guide, therefore, are not all-inclusive. If a tool, installation procedure, or work method that is not specifically recommended by Elkay is used, you must be satisfied that it is safe for yourself and others. You should also make sure that the product will not be damaged by the methods you choose. Most work-related accidents are caused by failure to observe basic safety rules or precautions. An accident can often be avoided by recognizing potentially hazardous situations before an accident occurs. As you install and maintain this product, you must be alert to potential hazards. You should also have the necessary training, skills, and tools to perform any installation or maintenance procedure.</p>
<p><strong>Safety Alert Symbol</strong><br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/ELKAY-EZH2O-Refrigerated-Surface-Mount-Bottle-Filling-Station-warning-1-3.webp" />This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death. This manual contains WARNINGS, CAUTIONS, NOTICES, SAFETY INSTRUCTIONS, and NOTES which must be followed to prevent the possibility of improper service, damage to the equipment, personal injury, or death. The following keywords call the reader’s attention to potential hazards. Hazards are identified by the “Safety Alert Symbol”  and followed by a signal word such as “WARNING” or “CAUTION”.</p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/ELKAY-EZH2O-Refrigerated-Surface-Mount-Bottle-Filling-Station-warning-1-4.webp" /><strong>WARNING </strong></p>
<p>These warnings indicate a potentially hazardous situation that, if not avoided, could result in serious injury or death. Follow all instructions related to the installation and/or maintenance of this product (unit).<br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/ELKAY-EZH2O-Refrigerated-Surface-Mount-Bottle-Filling-Station-warning-2.webp" /> <strong>Personal Protection</strong><br />
Be sure to use all personal protective equipment, such as sturdy safety glasses, work shoes, hearing protection, and gloves, whenever necessary, to ensure your own safety.</p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/ELKAY-EZH2O-Refrigerated-Surface-Mount-Bottle-Filling-Station-icon-3-1.webp" /> To avoid eye injury, always wear protective glasses with side shields when using power tools. Also, make sure no one else can be injured by flying particles when using power tools.</p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/ELKAY-EZH2O-Refrigerated-Surface-Mount-Bottle-Filling-Station-icon-4-1.webp" /> To prevent possible damage to your hearing, always wear ear protection, such as earmuffs or earplugs, when using power tools.</p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/ELKAY-EZH2O-Refrigerated-Surface-Mount-Bottle-Filling-Station-icon-5-1.webp" /> This product is heavy and can cause bodily injury, due to its weight or if the unit is dropped. Use two people to lift the product when unpacking the unit or installing it onto the hanger brackets.<br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/ELKAY-EZH2O-Refrigerated-Surface-Mount-Bottle-Filling-Station-icon-6-1.webp" /> Wear protective gloves during installation to protect against sharp edges from sheet metal components.</p>
<p><strong><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/ELKAY-EZH2O-Refrigerated-Surface-Mount-Bottle-Filling-Station-icon-7-1.webp" />Lifting Hazard</strong></p>
<ul>
<li>To avoid personal injury, always use these proper lifting techniques and use two</li>
<li>Use appropriate lifting devices to move the load.</li>
<li> Always use two people when lifting heavy or bulky cartons. DO NOT attempt to lift objects that are too heavy.</li>
</ul>
<p><strong><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/ELKAY-EZH2O-Refrigerated-Surface-Mount-Bottle-Filling-Station-icon-8-1.webp" /> Power Tool Hazard</strong><br />
To prevent personal injury or possible death, always follow the electrical safety recommendations of the power tool’s manufacturer.</p>
<ul>
<li>Do not use power tools in an unsafe manner.</li>
<li>Power tools should only be connected to a circuit protected by a ground-fault circuit interrupter (GFCI).</li>
<li>If an extension cord is required, always use an OSHA-approved extension cord.</li>
</ul>
<p><strong><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/ELKAY-EZH2O-Refrigerated-Surface-Mount-Bottle-Filling-Station-icon-9-1.webp" /> Shock and Electrocution Hazards</strong><br />
Failure to follow these instructions could result in severe burns, significant injuries, and even death.<br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/ELKAY-EZH2O-Refrigerated-Surface-Mount-Bottle-Filling-Station-icon-10-1.webp" /> Water will conduct electric current to create a short circuit, resulting in injury or death.</p>
<ul>
<li>Never use electric power tools around water or wet floors/surfaces.</li>
<li>Keep all liquids away from electrical cords and power tools.</li>
<li>If an extension cord is required, always use an OSHA-approved cord.</li>
<li>DO NOT create a short circuit between a source of electricity and a liquid by being in contact with both simultaneously</li>
</ul>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/ELKAY-EZH2O-Refrigerated-Surface-Mount-Bottle-Filling-Station-icon-11-1.webp" />Contacting live electrical wiring with power tools or hand tools can cause serious injury or death.</p>
<ul>
<li>Make sure all related circuit breakers are turned OFF.</li>
<li>Test for live circuits or wiring inside any wall where installation of the product requires cutting into a wall.<br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/ELKAY-EZH2O-Refrigerated-Surface-Mount-Bottle-Filling-Station-icon-12-1.webp" /> Prior to any maintenance, make sure the unit is unplugged and circuit breakers are turned OFF.<br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/ELKAY-EZH2O-Refrigerated-Surface-Mount-Bottle-Filling-Station-icon-13-1.webp" /> Prior to installation, test for live circuits or wiring inside the wall before cutting or drilling into the wall.</li>
</ul>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/ELKAY-EZH2O-Refrigerated-Surface-Mount-Bottle-Filling-Station-warning-1-5.webp" /><strong>WARNING</strong></p>
<p>These cautions indicate a potentially hazardous situation that, if not avoided, may result in minor or moderate injury. Follow all instructions related to the installation and/or maintenance of this product.</p>
<p><strong><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/ELKAY-EZH2O-Refrigerated-Surface-Mount-Bottle-Filling-Station-icon-14-1.webp" /> Tripping Hazard</strong><br />
Personal injury can result from tripping over<br />
power cords, tools, or other installation items.<br />
DO NOT leave items laying around the work area.<br />
<strong><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/ELKAY-EZH2O-Refrigerated-Surface-Mount-Bottle-Filling-Station-icon-15-1.webp" /> Cutting Hazard</strong><br />
The installation of this product may require using power tools. Keep hands away from the cutting edge of any tool used in the installation of our product. Placing fingers in or around the cutting blades could result in serious personal injury.</p>
<h4>Changing the Factory Default Settings (Not Required for Installation)</h4>
<p><strong>Accessing the Programming Button</strong></p>
<ol>
<li>Remove the bottle filler top cover by removing the two screws using a 5/32” Allen wrench. Do not discard the screws, they are required for re-assembly.</li>
<li>Locate the programming button at the top right side of the unit on the control board.</li>
</ol>
<p><strong>Access the Programming Menu</strong></p>
<ol>
<li>Depress the program button for approximately two seconds until the display changes, then release.</li>
<li>The display will scroll through two messages.<br />
a. RST FLTR – Reset Filter Monitor (filtered units only).<br />
b. SETTINGS – System Setting Sub Menu. Depress the program button when the display reads<br />
SETTINGS. The display will scroll through four messages:<br />
• RNG SET – Range set for IR sensor. Default is 3.<br />
• UNIT TYP – Type of unit. Default is refrigerated.<br />
• FLT SIZE – Select filter capacity. Default is 3000 GAL.<br />
• RST BCNT – Reset bottle count (filtered units only).</li>
<li>Push the button while the desired message is displayed. If the program button is not pushed, the messages will cycle three times before resetting back to run mode.</li>
</ol>
<p><strong>Reset the Filter Monitor (Filtered Unit Only)</strong></p>
<ol>
<li>Depress the program button when the display reads RST FLTR.</li>
<li>Depress the program button when the display reads FLTR = and the display will change to FLTR = 0.</li>
<li>The green LED on the bottle filler panel should now be illuminated indicating that the filter monitor has been reset.</li>
</ol>
<p><strong>Change the Range Of The IR Sensor</strong></p>
<ol>
<li>Depress the program button when the display reads RNG SET.</li>
<li>The display will show the default RNG = 3. 1-10 is the range, 1 is closest to the sensor, 10 is farthest away.</li>
<li>Depress the button again to change the value. When the desired range is selected, wait four seconds for the unit to default back to run mode.</li>
<li>Test the bottle filler by placing a hand or a bottle in front of the sensor.</li>
</ol>
<p><strong> Change the Unit Type</strong></p>
<ol>
<li>Depress the program button when the display reads UNIT TYP.</li>
<li>The display will show the default REFRIG.</li>
<li>Depress button to change to refrigerated if NONREFRIG is displayed.</li>
<li>When the desired range is selected, wait four seconds for the unit to default back to run mode.</li>
<li>Test the bottle filler by placing a  hand or a bottle in front of the sensor.</li>
</ol>
<p><strong>Change the Filter Capacity (Filtered Unit Only)</strong></p>
<ol>
<li>Depress the program button when the display reads FLT SIZE.</li>
<li>The display will show the default 3000GAL.</li>
<li>Depress the button again to change the value to 6000GAL.</li>
<li>When the desired range is selected, wait four seconds for the unit to default back to run mode.</li>
</ol>
<p><strong> Resetting the Bottle Count</strong></p>
<ol>
<li>Depress the program button when the display reads RST BCNT.</li>
<li>The display will show the current value, e.g. 0033183.</li>
<li>Depress the button again to change the value to 0. The display will show BTLCT = 0 for approximately 2 seconds and return to run mode showing 0000000 on the display board.</li>
</ol>
<p><strong> Resetting the Bottle Count</strong></p>
<p>1. Depress the program button when the display reads RST BCNT.<br />
2. The display will show the current value, e.g. 0033183.<br />
3. Depress the button again to change the value to 0. The display will show BTLCT = 0 for approximately 2 seconds and return to run mode showing 0000000 on the display board.<br />
<strong>Note:</strong> Once the bottle count is reset to 0, there is no way to return to the previous count.</p>
<ol>
<li>Test the bottle filler by placing a hand or a bottle in front of the sensor and dispensing product until the bottle count changes to 1.</li>
</ol>
<h4>Cleaning Instruction</h4>
<p><strong>Stainless Steel</strong></p>
<ol>
<li>General Cleaning: Use an ordinary mild detergent and soft cloth, rinse and towel dry.</li>
<li>Steel soap pads should never be used; particles can adhere to a stainless steel basin surface and will eventually rust.</li>
<li>Light scratches are normal for stainless steel basins; Over over time, they will blend into the uniform finish pattern.</li>
</ol>
<p><strong> Plastic Components</strong></p>
<ol>
<li>General cleaning: Use an ordinary mild detergent and soft cloth, rinse and towel dry.</li>
<li> Wiping the surface clean to remove debris or build-up will not hurt the antimicrobial properties.</li>
</ol>
<h4>Filter Cartridge Replacement for Filtered Units Only</h4>
<ol>
<li>Remove the front cover of the cooler by removing two 5/16″ screws located on the bottom of the cooler.<br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/ELKAY-EZH2O-Refrigerated-Surface-Mount-Bottle-Filling-Station-Cartridge-Replacement-1-291x300-2.webp" /></li>
<li>Shut the oﬀ water supply using the shut oﬀ valve. Turn the water shut oﬀ valve handle to the OFF position (clockwise).<br />
<strong>Note:</strong> This view may be different depending on the model and configuration.<br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/ELKAY-EZH2O-Refrigerated-Surface-Mount-Bottle-Filling-Station-Cartridge-Replacement-2-300x208-2.webp" /></li>
<li>Activate the water dispenser with a water bottle to relieve pressure and access water in the waterline.<br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/ELKAY-EZH2O-Refrigerated-Surface-Mount-Bottle-Filling-Station-Cartridge-Replacement-3-300x298-2.webp" /></li>
<li>Shut OFF power to the unit by unplugging.<br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/ELKAY-EZH2O-Refrigerated-Surface-Mount-Bottle-Filling-Station-4-300x221-2.webp" /></li>
<li>Locate the current filter on the left side of the cooler.<br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/ELKAY-EZH2O-Refrigerated-Surface-Mount-Bottle-Filling-Station-5-300x267-2.webp" /></li>
<li>Place a towel under the filter to absorb any water that leaks out of the filter when it is removed.</li>
<li>Twist the filter counterclockwise until it is disengaged. Remove the filter and keep it upright; remove the towel.<br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/ELKAY-EZH2O-Refrigerated-Surface-Mount-Bottle-Filling-Station-6-279x300-2.webp" /></li>
<li>Drain the filter before disposing of it in a trash can.</li>
<li>Remove the protective cap from the new filter.<br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/ELKAY-EZH2O-Refrigerated-Surface-Mount-Bottle-Filling-Station-7-278x300-2.webp" /></li>
<li> Mark the current date on the filter label.</li>
<li>Attach the filter to the filter head with the label facing outward by fi rmly inserting it into the head and by rotating the fi lter head clockwise, if required.<br />
<strong>Note:</strong> The filter label should be readable from the front of the filter during installation.<br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/ELKAY-EZH2O-Refrigerated-Surface-Mount-Bottle-Filling-Station-10-300x211-2.webp" /></li>
<li>Restore power back to the unit.</li>
<li>Turn on the water supply.</li>
<li>Verify proper dispensing by placing a cup or any object in front of sensor area and verifying water dispenses. Dispense at least two gallons of water to bleed oﬀ any trapped air from supply lines and fi ne carbon particles from the fi lter.<br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/ELKAY-EZH2O-Refrigerated-Surface-Mount-Bottle-Filling-Station-8-268x300-2.webp" /></li>
<li>Check all the lines and connections for water leaks. Repair connections if necessary. If there are no leaks and the unit is functioning correctly.</li>
<li>Reinstall front panel with 5/16” screws.<br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/ELKAY-EZH2O-Refrigerated-Surface-Mount-Bottle-Filling-Station-9-285x300-2.webp" /><strong>Note:</strong> Once power is applied to the bottle filler, the GREEN LED light should illuminate showing good filter status (if equipped with filter) along with the LCD Bottle Counter.<br />
GREEN: 0 – 80% of Filter Life or 0 – 11 Months (Whichever Comes First).<br />
YELLOW: 80 – 100% of Filter Life or 11 – 12 Months (Whichever Comes First).<br />
RED: 100% Plus of Filter Life or 12 Months (Whichever Comes First).</li>
<li>Reset the filter status indicator:</li>
</ol>
<p>The programming button is located at the top right side of the unit on the control board.</p>
<ol>
<li>To access the program button, take oﬀ the top cover of the bottle filler by removing the two screws holding it in place.</li>
<li>Remove the screws using a 5-32 inch Allen wrench (Do not discard the mounting screws; they will be needed to reinstall the top cover once programming is complete).<br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/ELKAY-EZH2O-Refrigerated-Surface-Mount-Bottle-Filling-Station-Screw-261x300-2.webp" /></li>
<li>Remove the top cover.<br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/ELKAY-EZH2O-Refrigerated-Surface-Mount-Bottle-Filling-Station-Screw-2-300x290-2.webp" /></li>
<li>To remove the cover, depress the program button when the display reads RST FLTR.<br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/ELKAY-EZH2O-Refrigerated-Surface-Mount-Bottle-Filling-Station-Screw-1-300x287-2.webp" /></li>
<li>Depress the program button when the display reads FLTR = and the display will change to FLTR = 0.</li>
<li>The green LED on the bottle filler panel should now be illuminated indicating that the filter monitor has been reset.</li>
<li> Filter Reset is complete.</li>
</ol>
<p><strong>Picture is Cooler Only Without Bottle Filler</strong><br />
<strong>Note:</strong> Danger! Electric shock hazard. Disconnect power before serving unit.</p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/ELKAY-EZH2O-Refrigerated-Surface-Mount-Bottle-Filling-Station-Cooler-Top-View-300x227-2.webp" /><strong>Fig 1: Cooler Top View (EZ8WS Shown)</strong></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/ELKAY-EZH2O-Refrigerated-Surface-Mount-Bottle-Filling-Station-Cooler-Top-View-1-205x300-2.webp" /><strong>Fig 2: Cooler Front View</strong></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/ELKAY-EZH2O-Refrigerated-Surface-Mount-Bottle-Filling-Station-Basin-Cover-300x186-2.webp" /><strong>Fig 3: Basin Cover</strong></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/ELKAY-EZH2O-Refrigerated-Surface-Mount-Bottle-Filling-Station-Basin-Cover-1-300x283-2.webp" /><strong>Fig 4: Basin Assembly Kit</strong></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/ELKAY-EZH2O-Refrigerated-Surface-Mount-Bottle-Filling-Station-Basin-Cover-2-300x162-2.webp" /></p>
<p><strong>Fig 5: Front View with Aerator</strong></p>
<p><strong>Operation of Quick Connection Fitting </strong></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/ELKAY-EZH2O-Refrigerated-Surface-Mount-Bottle-Filling-Station-Poly-Tube-300x108-2.webp" /><strong>Fig 6: Poly Tube Quick Connect Fitting</strong></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/ELKAY-EZH2O-Refrigerated-Surface-Mount-Bottle-Filling-Station-Poly-Tube-1-152x300-2.webp" /><strong>Fig 7: Filter and Filter Head</strong></p>
<table width="1173">
<tbody>
<tr>
<td colspan="3" width="368">FILTER PARTS LIST</p>
<p>(See Fig 7: Filter and Filter Head)</td>
</tr>
<tr>
<td width="56">ITEM NO.</td>
<td width="82">PART NO.</td>
<td width="231">DESCRIPTION</td>
</tr>
<tr>
<td width="56">1<br />
2</td>
<td width="82">51300C<br />
0000000746</td>
<td width="231">Filter Assy-3000 Gal<br />
Assy-Filter &amp; Bracket includes Fltr Head/Mtg Bkt/John Guest Ftgs/Screws</td>
</tr>
</tbody>
</table>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/ELKAY-EZH2O-Refrigerated-Surface-Mount-Bottle-Filling-Station-Wiring-Diagram-300x193-2.webp" /><strong>Fig 8: 115V Wiring Diagram</strong></p>
<p><strong> Cooler Parts List</strong></p>
<table width="1127">
<tbody>
<tr>
<td width="41">ITEM NO.</td>
<td width="70"> PART NO.</td>
<td width="229"> DESCRIPTION</td>
</tr>
<tr>
<td width="41">1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
9<br />
10<br />
11<br />
12<br />
13<br />
14<br />
15<br />
16<br />
17<br />
–</td>
<td width="70">28551C<br />
36208C<br />
*36322C<br />
0000000238<br />
55996C<br />
56092C<br />
66703C<br />
98773C<br />
98775C<br />
98776C<br />
98777C<br />
98778C<br />
28525C<br />
28528C<br />
2000000075<br />
2000000076<br />
1000006133<br />
See Filter Table</td>
<td width="229">Hanger Bracket Power Cord Compressor Serv. Pak EMIS70HHR Kit – Electricals /OL/Relay/Cvr Strainer (See “General Instructions”) Tubing – Poly (Cut To Length)<br />
Drier<br />
Kit – Cold Control/Screws<br />
Kit – Fan Motor Assy/Blade/Motor/Shroud/Nut Kit – Condenser/Drier<br />
Kit – Compr Mtg Hdwe/Grommets/Clips Studs Kit – Heat Exchanger/Drier<br />
Panel – Right Rear Panel – Left Rear Kit – Basin Cover<br />
Kit – Basin Assembly Panel – Front Cover<br />
Water Filter Kit (When Provided)</td>
</tr>
</tbody>
</table>
<p><strong>Bottle Filler Parts List</strong></p>
<table width="1094">
<tbody>
<tr>
<td width="41">ITEM NO.</td>
<td width="75">PART NO.</td>
<td width="184">DESCRIPTION</td>
</tr>
<tr>
<td width="41">18<br />
19<br />
20<br />
21<br />
22</td>
<td width="75">98543C<br />
98544C<br />
1000004573<br />
98546C<br />
98547C</td>
<td width="184">Kit – Electrical Package Kit – IR Sensor<br />
Kit – Solenoid Valve Replacement Kit – Aerator ReplacementKit – Top Cover Replacement</td>
</tr>
</tbody>
</table>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/ELKAY-logo-1-300x55-4.webp" />*Replace With Same Compressor Used in Original Assembly.<br />
<strong>Note:</strong> All correspondence pertaining to any of the above<br />
components for repair parts MUST include Model<br />
No. and Serial No., name and part number of<br />
replacement part.</p>
<form id="commentform" class="comment-form" action="https://manuals.plus/wp-comments-post.php" method="post" novalidate="">
<p class="form-submit">
</form>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>ELKAY Crosstown Stainless Steel 16-7 Manual</title>
		<link>https://usemanuals.com/elkay/crosstown-rack-16-7/</link>
		
		<dc:creator><![CDATA[ItsManual]]></dc:creator>
		<pubDate>Mon, 21 Aug 2023 16:42:33 +0000</pubDate>
				<category><![CDATA[ELKAY]]></category>
		<guid isPermaLink="false">https://usemanuals.com/?p=203222</guid>

					<description><![CDATA[ELKAY Crosstown Stainless &#160; AMERICAN PRIDE. A LIFETIME TRADITION. Like your family, the Elkay family has values and traditions that endure. For almost a century, Elkay has been a family-owned and operated company, providing thousands of jobs that support our families and communities. PRODUCT SPECIFICATIONS Elkay Crosstown Stainless Steel 16-7/8″ x 6-3/4″ x 4-1/4″ Drying Rack with Wood Handles. Overall dimensions are 16-7/8″ x 6-3/4″ x 4-1/4″. Made of Stainless Steel. Material: Stainless Steel Finish: Polished Stainless Steel Dimensions: 16-7/8″ x 6-3/4″ x 4-1/4″ Shipping Weight: 3 lbs. CUSTOM SIZED: Designed to fit into place in specific Elkay sinks. INCREASE FUNCTIONALITY: Elkay accessories are designed to enhance the functionality of your sink and make your daily routines easier. ABOUT ELKAY: Founded in 1920, we offer high-quality plumbing products for residential and commercial use. PART:________________________________QTY: _____________ PROJECT:______________________________________________ CONTACT:______________________________________________ DATE:__________________________________________________ NOTES:_________________________________________________ APPROVAL:_____________________________________________ In keeping with our policy of continuing product improvement, Elkay reserves the right to change product specifications without notice. Please visit elkay.com for the most current version of Elkay product specification sheets. This specification describes an Elkay product with design, quality, and functional benefits to the user. When making a comparison of other producers’ offerings, be certain these features are not overlooked. 1333 Butterfield Road, Suite 200 Downers Grove, IL 60515 LKDR0717SS_spec.pdf [...]<p><a class="btn btn-secondary understrap-read-more-link" href="https://usemanuals.com/elkay/crosstown-rack-16-7/">Read More...</a></p>]]></description>
										<content:encoded><![CDATA[<h3><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/logo-228.webp" /></h3>
<h4>ELKAY Crosstown Stainless</h4>
<p>&nbsp;</p>
<p>AMERICAN PRIDE. A LIFETIME TRADITION. Like your family, the Elkay family has values and traditions that endure. For almost a century, Elkay has been a family-owned and operated company, providing thousands of jobs that support our families and communities.</p>
<h4>PRODUCT SPECIFICATIONS</h4>
<p>Elkay Crosstown Stainless Steel 16-7/8″ x 6-3/4″ x 4-1/4″ Drying Rack with Wood Handles. Overall dimensions are 16-7/8″ x 6-3/4″ x 4-1/4″. Made of Stainless Steel.</p>
<table width="397">
<tbody>
<tr>
<td colspan="2" width="383"></td>
</tr>
<tr>
<td colspan="2" width="383"></td>
</tr>
<tr>
<td width="137"><strong>Material:</strong></td>
<td width="246">Stainless Steel</td>
</tr>
<tr>
<td width="137"><strong>Finish:</strong></td>
<td width="246">Polished Stainless Steel</td>
</tr>
<tr>
<td width="137"><strong>Dimensions:</strong></td>
<td width="246">16-7/8″ x 6-3/4″ x 4-1/4″</td>
</tr>
<tr>
<td width="137"><strong>Shipping Weight:</strong></td>
<td width="246">3 lbs.</td>
</tr>
<tr>
<td colspan="2" width="383"></td>
</tr>
</tbody>
</table>
<ul>
<li>CUSTOM SIZED: Designed to fit into place in specific Elkay sinks.</li>
<li>INCREASE FUNCTIONALITY: Elkay accessories are designed to enhance the functionality of your sink and make your daily routines easier.</li>
<li>ABOUT ELKAY: Founded in 1920, we offer high-quality plumbing products for residential and commercial use.<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/image-1-161.webp" /></li>
</ul>
<p>PART:________________________________QTY: _____________<br />
PROJECT:______________________________________________<br />
CONTACT:______________________________________________<br />
DATE:__________________________________________________<br />
NOTES:_________________________________________________<br />
APPROVAL:_____________________________________________</p>
<p>In keeping with our policy of continuing product improvement, Elkay reserves the right to change product specifications without notice. Please visit elkay.com for the most current version of Elkay product specification sheets. This specification describes an Elkay product with design, quality, and functional benefits to the user. When making a comparison of other producers’ offerings, be certain these features are not overlooked.</p>
<p>1333 Butterfield Road, Suite 200 Downers Grove, IL 60515<br />
LKDR0717SS_spec.pdf<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/logo-228-1.webp" /></p>
<form id="commentform" class="comment-form" action="https://manuals.plus/wp-comments-post.php" method="post" novalidate="">
<p class="form-submit">
</form>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>

<!--
Performance optimized by W3 Total Cache. Learn more: https://www.boldgrid.com/w3-total-cache/

Page Caching using Disk: Enhanced 

Served from: usemanuals.com @ 2026-06-04 00:31:18 by W3 Total Cache
-->