<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Dyna-Glo &#8211; UseManuals</title>
	<atom:link href="http://usemanuals.com/dyna-glo/feed/" rel="self" type="application/rss+xml" />
	<link>https://usemanuals.com</link>
	<description>Owner&#039;s manuals for all sorts of products</description>
	<lastBuildDate>Mon, 10 Jul 2023 12:30:00 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.7.2</generator>

<image>
	<url>https://usemanuals.com/wp-content/uploads/2025/02/favicon-32x32-2.png</url>
	<title>Dyna-Glo &#8211; UseManuals</title>
	<link>https://usemanuals.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Dyna-Glo FA40DGP-01 Propane Construction Heater Manual</title>
		<link>https://usemanuals.com/dyna-glo/fa40dgp-01-heater/</link>
		
		<dc:creator><![CDATA[ItsManual]]></dc:creator>
		<pubDate>Mon, 10 Jul 2023 12:30:00 +0000</pubDate>
				<category><![CDATA[Dyna-Glo]]></category>
		<guid isPermaLink="false">https://usemanuals.com/?p=152704</guid>

					<description><![CDATA[&#160; PROPANE CONSTRUCTION HEATER USER’S MANUAL AND OPERATING INSTRUCTIONS Dyna-Glo™DELUX MODELS RMC-FA40DGD RMC-FA50DGD RMC-FA60DGD RMC-FA100DGD RMC-FA125DGD/LPFA125DGD RMC-FA150DGD (40,000 BTU/HR,                 FORCED – AIR) (30,000/50,000 BTU/HR,     FORCED – AIR)(30,000/60,000 BTU/HR,     FORCED – AIR)(70,000/100,000 BTU/HR,   FORCED – AIR)(70,000/125,000 BTU/HR,   FORCED – AIR)(120,000/150,000 BTU/HR, FORCED – AIR) Dyna-Glo™Pro MODELS: RMC-FA40/DGP/DGP-01 RMC-FA50/DGP/DGP-01 RMC-FA60/DGP/DGP-01 RMC-FA100/DGP/DGP-01 RMC-FAl25/DGP/DGP-01 LPFAl25H/LPFAl25H-01 RMC-FA150/DGP/DGP-01 (40,000 BTU/HR, FORCED – AIR) (30,000/50,000 BTU/HR, FORCED – AIR) (30,000/60,000 BTU/HR, FORCED – AIR) (70,000/100,000 BTU/HR, FORCED – AIR) (70,000/125,000 BTU/HR, FORCED – AIR)(120,000/150,000 BTU/HR, FORCED -AIR) GENERAL HAZARD WARNING FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTIONS PROVIDED WITH  THIS HEATER, CAN RESULT IN  EATH,  SERIOUS BODILY INJURY AND PROPERTY LOSS, OR DAMAGE FROM THE HAZARDS OF FIRE, EXPLOSION, BURN.  ASPHYXIATION, CARBON MONOXIDE POISONING, AND/OR ELECTRICAL SHOCK. ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD USE OR SERVICE THIS HEATER. IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN INSTRUCTION MANUAL, LABELS, ETCETERA, CONTACT THE MANUFACTURER. CONSUMER: Retain this manual for future reference. Questions, problems, missing parts? Before returning to your retailer, call our customer service department at 877-447-4768 8:30 a.m. – 4:30 pm CST, Monday – Friday or email us at customerservice@ghpgroupinc.com www.ghpgroupinc.com Printed in China IMLPFDG – GDK WARNING: FIRE, BURN, INHALATION, AND EXPLOSION HAZARD, KEEP SOLID COMBUSTIBLES, SUCH AS BUILDING  ATERIALS, PAPER, OR CARDBOARD, A SAFE DISTANCE AWAY FROM THE HEATER AS RECOMMENDED BY THE INSTRUCTIONS. NEVER USE THE HEATER IN SPACES THAT DO OR MAY CONTAIN VOLATILE OR AIRBORNE COMBUSTIBLES, OR PRODUCTS  SUCH AS GASOLINE, SOLVENTS, PAINT THINNERS, DUST PARTICLES, OR UNKNOWN CHEMICALS. CALIFORNIA PROPOSITION 65: Fuels used in gas or oil-fired appliances and the products of combustion of such fuels contain chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm. This product contains chemicals, including lead and lead compounds, known to the State of California to cause cancer, birth defects, or other reproductive harm. Wash hands after handling. WARNING: Using this heater in a residential garage requires that the heater is positioned so that it is protected against any possible damage by a moving vehicle, etc. It must be positioned so that the base of the heater is no less than 18 in (450 mm) above the garage floor or 8 ft (2450 mm) in repair garages. The heater must be placed on a stable surface. Do not place it on a chair, ladder, etc. Raising the heater will reduce BUT NOT eliminate the possibility of lighting the vapor of any flammable liquids which may be improperly stored or accidentally spilled. If the smell of gasoline is present, DO NOT operate this heater until the area has been properly ventilated. WARNING: CONSTRUCTION HEATERS ARE NOT FOR USE IN GARAGES IN CANADA. WARNING: NOT FOR HOME OR RECREATIONAL VEHICLE USE. NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! PROPANE CONSTRUCTION HEATER DYNA-GLO PROPANE FORCED AIR CONSTRUCTION HEATERS The heater is designed and approved for use as a construction heater under ANS Z83.7 CSA 2.14. It is hard to anticipate every use which may be made of this heater. CHECK WITH YOUR LOCAL FIRE SAFETY AUTHORITY IF YOU HAVE QUESTIONS ABOUT APPLICATIONS. Other standards govern the use of fuel gases and heat-producing products in specific applications. Your local authority can advise you about these. IMPORTANT: READ THIS USER’S MANUAL CAREFULLY AND COMPLETELY BEFORE TRYING TO OPERATE OR SERVICE THIS  HEATER. IMPROPER USE OF THIS HEATER CAN CAUSE SERIOUS INJURY OR DEATH FROM FIRE, EXPLOSION, AND CARBON MONOXIDE POISONING. This is a direct-fired forced air construction heater for either indoor construction or outdoor use. Its intended use is primarily the temporary heating of buildings or structures under construction, alteration, or repair. All the products of combustion generated by the heater are forced through the heater and released into the area being heated. This heater operates at approximately 98%+ combustion efficiency but still produces a small amount of carbon monoxide. Humans can tolerate small amounts of carbon monoxide for short periods. Carbon monoxide can build up in a heated space and failure to provide adequate ventilation could result in poisoning or death. WARNING: NOT FOR USE WITH DUCTWORK. SPECIFICATIONS  Model No. RMC-­‐FA40DGP/ DGP-­‐01  FA50 Series  FA60 Series RMC-­‐FA100DGD/ DGP/DGP-­‐01 LPFA125DGD/ RMC-­‐FA125DGP/ DGP-­‐01 LPFA125H/H-­‐01/ RMC-­‐FA125DGD  RMC-­‐FA150DGD  Input Rating  40,000 BTU/hr 30,000 BTU/hr 50,000 BTU/hr 30,000 BTU/hr 60,000 BTU/hr 70,000 BTU/hr 100,000 BTU/hr 70,000 BTU/hr 125,000 BTU/hr 70,000 BTU/hr 125,000 BTU/hr 120,000 BTU/hr 150,000 BTU/hr  Type of Gas  Propane  Propane  Propane  Propane  Propane  Propane  Propane  Gas Supply Pressure to Regulator Maximum  Cylinder Pressure  Cylinder Pressure  Cylinder Pressure  Cylinder Pressure  Cylinder Pressure  Cylinder Pressure  Cylinder Pressure  Minimum (for purpose of Input Adjustment)  5psig  5psig  5psig  5psig  5psig  5psig  5psig  Manifold Pressure  11″ W.C  11″ W.C  11″ W.C  11″ W.C  11″ W.C  11″ W.C  11″ W.C  Gas Consumption  1.9lbs/hr  0.86 kg/hr 1.4lbs/hr 2.3lbs/hr 0.63 kg/hr 1.04 kg/hr 1.4lbs/hr 2.8lbs/hr 0.63 kg/hr 1.27 kg/hr 3.3lbs/hr 4.6lbs/hr 1.5 kg/hr 2.09 kg/hr 3.3lbs/hr 5.8lbs/hr 1.5 kg/hr 2.63 kg/hr 3.3lbs/hr 5.8lbs/hr 1.5 kg/hr 2.63 kg/hr 5.6lbs/hr 7.0lbs/hr 2.54 kg/hr 3,18 kg/hr  Electrical Input  120V, 60Hz, 1Ø  120V, 60Hz, 1Ø  120V, 60Hz, 1Ø  120V, 60Hz, 1Ø  120V, 60Hz, 1Ø  120V, 60Hz, 1Ø  120V, 60Hz, 1Ø  Amperage  Load 0.68amps  0.65amps  0.65amps  0.7amps  0.7amps  0.7amps  0.7amps   Fan Unload Load 3550rpm 3000rpm 3570rpm 3300rpm 3570rpm 3300rpm 3580rpm 3300rpm 3580rpm 3300rpm 3580rpm 3300rpm 3580rpm 3300rpm  Ignition  Piezo/Manual Spark  Continuous Spark  Continuous Spark  Continuous Spark  Continuous Spark  Continuous Spark  Continuous Spark  Spark Gap  0.16″ (4mm)  0.16″ (4mm)  0.16″ (4mm)  0.16″ (4mm)  0.16″ (4mm)  0.16″ (4mm)  0.11″ (2.8mm)  Size (LxWxH)  19.3″x8.3″x15.2″ (49.0×21.1×38.6)cm  19.3″x8.3″x15.2″ (49.0×21.1×38.6)cm  19.3″x8.3″x15.2″ (49.0×21.1×38.6)cm 25.6″x12.7″x15.6″ (65.0×32.3×39.6)cm 25.6″x11.8″x16.1″ (65.0×30.0&#215;40.9)cm 26.6″x13.0″x17.3″ (67.6×33.0&#215;43.9)cm 25.6″x11.8″x16.1″ (65.0×30.0&#215;40.9)cm 26.2″x11.8″x17.2″ (66.6×30.0&#215;43.6)cm 25.6″x11.8″x16.1″ (65.0×30.0&#215;41.0)cm  25.6″x11.8″x16.1″ (65.0×30.0&#215;40.9)cm PROPANE CONSTRUCTION HEATER GENERAL SAFETY INSTRUCTION Accidents are always tragic especially because so many of them could have been prevented with little care and judgment. There are some basic good practices, we hope you will follow for safe use of your heater. IMPORTANT SAFETY INSTRUCTION Children should be carefully supervised when they are in the area. Always maintain proper clearance from combustible materials. Minimum clearance from combustibles: Side – 24” (61 cm); Top – 36” (92 cm); Front – 72” (183 cm). Floor – combustible. Not for use on finished floors. Heater must be placed on a level and stable surface. Never place anything including clothes or other flammable items on the heater. The appliance area shall be kept clear and free from combustible materials, gasoline, and other flammable vapors and liquids. Do not modify or operate a heater that has been modified. Adequate clearance for accessibility and for combustion &#38; ventilation air supply must be maintained at all times when the heater is operating. Service and repair should be done by a qualified service person. The heater should be inspected before each use and at least annually by a qualified person. More frequent cleaning may be required as necessary. Do not service while hot or operating. Never connect the heater to an unregulated gas supply. The heater is shipped from the factory for LP(Propane) gas. This heater is for use with propane gas only, do not convert the heater to any other gas. Installation must conform to local codes or, in the absence of local codes, with the standard for the Storage and Handling of Liquefied Petroleum Gases ANSI/NFPA 58 and the Natural Gas and Propane Installation Code CSA B149.1 The minimum and maximum inlet pressures to the regulator from the gas tank are 5 psi and bottle pressure, respectively. Use only the regulator &#38; hose assembly provided with the heater. Inspect the regulator/hose assembly prior to each use of the heater. If there is excessive abrasion or wear, or the hose is cut, replace it with the regulator/hose assembly listed on the parts list prior to using this heater. Gas supply connections should be checked using a 50/50 solution of liquid dish soap and never use a flame to check for gas leaks. The electrical connection &#38; grounding must comply with National Electrical Code. ANSI/NFPA 70 or in Canada CSA C22.1, Canadian Electrical Code, Part 1. Use only a properly grounded three (3) prong receptacle. Do not restrict inlet or outlet by any means. The flow of combustion and ventilation air is not to be obstructed. This heater should not be directed toward any propane-gas container within 20 ft (6M). The heater must be located at least 6 ft. (1.83 m) in the U.S.; or (ii) 10 ft. (3 m) in Canada, from any propane gas container. The propane cylinder supply system must be arranged to provide for vapor withdrawal from the operating cylinder. This heater is not to be used with external thermostats, timers, or other devices that control or alter the electrical supply to the heater. WARNING: Motor and fan must be running before lighting, during operation, and at shutdown, in order to prevent a flame-out condition that could result in personal injury or property damage. PRODUCT FEATURES Portable &#38; Stable Wind Resistant &#38; Rain Protected Continuous Spark Ignition or  Piezo Electric Spark Ignition 100% Safety Shutoff System Continuous Adjustable Input Ratings (Except FA40) UNPACKING HEATER Remove the heater from the carton. Remove all protective packing applied to the heater for shipment. Retain cartons and packaging material until the unit is operated and found in good condition. Check the heater for any shipping damage. If the heater shows any external or internal damage, promptly inform the dealer/distributor where you purchased the heater. Assembly Components and Instructions for Steel Base Units: Tools required for assembly: All Models: Adjustable Wrench FA100 – FA150: Phillips Head Screw Driver Contents: All Models: Unit, Manual, Hose and Regulator Assembly FA100 – FA150 Series Includes: 2 Cord Wrap Attachments, 4 Screws (ST3.5×10) Assembly Time: 5 Minutes 1. Assembling the Cord Wrap Attachments: (FA100 – FA150 Series Only) Parts Required: 4 Screws (ST3.5×10), and 2 Cord Wrap Attachments Place the cord wrap attachment as shown, then use Phillips screwdriver to tighten the screws and secure the cord wrap attachments. 2. Regulator and Hose Connection: (All Models) See figure on right. Connect the hose tightly to the heater using a wrench. Please also refer to page 8 in the manual. Assembly Components and Instructions for Plastic Base Units: Tools required for assembly: All Models: Adjustable Wrench FA125 Series: Phillips Head Screw Driver Contents: All Models: Unit, Manual, Hose and Regulator Assembly, Adjustable Leg, 2 Height Control Screws FA125 Series Includes: 2 Cord Wrap Attachments, 4 Screws (ST3.5×10) Assembly Time: 5 Minutes 1. Assemble the Leg: 2. Assemble the Height Control Screw: Parts Required: Height Control Screw 2 pcs Turn the Height Control Screw clockwise to lock it. Turn the Height Control Screw counterclockwise to unlock it. 3. Assembling the Cord Wrap Attachments: Parts Required: 4 Screws (ST3.5X10) and 2 Cord Wrap Attachments Place the cord wrap attachments as shown, then use a Phillips screwdriver to tighten the screws and secure the cord wrap attachments. 4. Regulator and Hose Connection: See figure on right. Connect the hose tightly to the heater using a wrench.  Please also refer to page 8 in the manual. INFORMATION ON SIZE * CAPACITY OF PROPANE GAS CYLINDERS: The chart below shows the number and size of propane tanks needed to run this heater. *Less gas is vaporized at lower temperatures. You may need two or more 100 pounds (45 kg) tanks or one larger tank in colder weather. (See the parts list for your model of heater to get the specified regulator assembly.) Temperature (°F-°C) at tank Number of Tanks 40,000-60,000 BTU/h 100,000 -125,000 BTU/h 150,000 BTU/h Above 32°F (0°C) 1 – 20lb (9kg) 2 – 100lb (45kg) 2 – 100lb (45kg) 32°F (0°C) 1 – 20lb (9kg) 2 – 100lb (45kg) 2 – 100lb (45kg) 20°F (-7°C) 1 – 20lb (9kg) 2 – 100lb (45kg) 3 – 100lb (45kg) 10°F (-12°C) 1 – 20lb (9kg) 3 – 100lb (45kg) 3 – 100lb (45kg) -10°F (-23°C) 2 – 20lb (9kg) Use Larger Tank Use Larger Tank -20°F (-29°C) 1 – 100lb (45kg) Use Larger Tank Use Larger Tank The propane (LP) gas tank must also be equipped with the following: A collar to protect the Propane gas valve. A shutoff valve terminating a Propane gas cylinder valve outlet as specified in the American National Standards for Compressed Gas Cylinder Valve  Outlets and Inlet Connections. A safety relief valve having direct communications with the vapor space of the tank. An arrangement of vapor withdrawal. The propane (LP) gas pressure regulator and hose assembly supplied with this heater must be used without alteration. The hose assembly shall be visually inspected prior to each use of the heater. If it is evident that there is excessive abrasion or wear, or the hose is cut, it must be replaced prior to the heater being put into operation. The replacement hose assembly shall be that specified by the manufacturer. INSTALLATION TO THE PROPANE GAS TANK IMPORTANT: You must use a propane/LP gas supply cylinder that is compatible with the connection device provided with the hose and regulator. Provide propane/LP supply system. Ensure that the valve on the cylinder is fully closed by turning the knob fully clockwise ( ). Ensure that the cylinder is fully upright for vapor withdrawal. (see size/capacity, page 7). Connect a hose to heater inlet. Tighten firmly using a wrench. You must use the regulator supplied with the heater Connect fuel gas fitting hose/regulator assembly to propane LP tank(s). 3a. For units with a POL fitting (see figure 1) turn fuel fitting counterclockwise into threads on the tank. Tighten firmly using a wrench. Some models have a handwheel that can be used to tighten the fitting. This handwheel can be slid off of the nut so that a wrench can also be used to tighten the fitting. IMPORTANT: Position the regulator so that hose leaving the regulator is in a horizontal position. 3b. For units with a QCC fitting (see figure 2) turn QCC gas fitting clockwise onto threads on the tank. Tighten firmly using your hand (DO NOT USE A WRENCH). IMPORTANT: Position the regulator so that the regulator vent is pointing down toward the floor and the arrow on the regulator is visible. Open propane/LP supply valve on propane/LP tank(s) slowly. NOTE: If not opened slowly, the excess flow device in the regulator may stop gas flow. If this happens, close the propane/LP supply valve, wait one minute (or until you hear a click), and open again slowly. Check all connections for leaks. Apply a 50/50 solution of liquid dish soap and water to gas joints. Bubbles forming show a leak that must be corrected. Close propane / LP supply valve before attempting to repair the connection. WARNING: Purging and filling of LP gas tanks must be performed by personnel who has been thoroughly trained in accepted LP gas industry procedures. Failure to follow these instructions may result in an explosion, fire, severe personal injury, or death. REFILLING THE PROPANE GAS TANK ALL NEW CYLINDERS MUST BE PURGED BEFORE THE FIRST FILLING. Turn heater gas valve knob and gas tank valve to OFF position. Propane tank valve equipped with the old style fitting has LEFT HANDED THREADS. Turn POL fitting CLOCKWISE to loosen. Protect POL fitting when disconnected from the tank. Have tank filled by your local Propane gas supplier. Fasten full Propane tank and connect POL fitting to tank valve by turning COUNTERCLOCKWISE. With heater gas valve knob still in the OFF position, turn ON tank valve and check for leaks with soap solution. PROPANE SAFETY Propane is safe to use when properly handled. Careless handling of the Propane gas tank could result in fire and/or an explosion. Therefore: Always keep tank/cylinder securely fastened in an upright position. Avoid tipping tank on its side when connected to a regulator since this may cause damage to diaphragm in regulator. Handle valves with care. Never connect an unregulated Propane tank to construction heater. Do not subject Propane tank to excessive heat. Tightly close the gas shutoff valve on the Propane tank after each use. The POL fitting must be protected when disconnected from the propane tank. Never store a Propane gas tank inside a building or in the vicinity of any gas burning appliance. THE DISCONNECTED TANK MUST NEVER BE STORED IN A BUILDING, GARAGE OR ANY OTHER ENCLOSED AREA. LEAK CHECKING Check all gas connections with a soap solution to be sure they are tight and leak proof. The installation of your heater must meet all local codes and/or gas utility requirements or, in the absence of local codes, with the Storage and Handling of Liquefied Petroleum Gases, ANSI/ NFPA 58 and the Natural and Propane Installation Code, CSA B149.1. The minimum clearances to combustible construction: Side – 24” (61 cm); Top – 36” (92 cm); Front – 72” (183 cm); Floor – combustible, must be maintained at all times. The hose assembly should be visually inspected prior to each use of the heater. If it is evident that there is excessive abrasion or wear, or the hose is cut, it must be replaced prior to the heater being put into operation. The replacement hose assembly shall be that specified by the manufacturer (Refer to parts list). LIGHTING INSTRUCTIONS WARNING: Motor and fan must be running before lighting, during operation and shutdown, in order to prevent a flame-out condition which could result in personal injury or property damage. NOTE: This heater uses a continuous spark ignition system. This unit will continue to make a clicking/ ticking sound at all times before ignition, after ignition, and during operation, regardless of valve knob positioning.  Connect the power cord to a properly grounded three (3) prong 120V, 60Hz, single-phase receptacle. Turn gas valve knob clockwise to OFF position. Wait five (5) minutes to clear any gas. Then smell for gas, if you don’t smell gas, go to the next step. Turn gas supply ON by turning Propane tank valve counterclockwise . Push in and turn gas control knob counterclockwise  to “LOW/IGN”. This will light the burner. If needed, keep pressing the control knob until the burner lights and keep depressing and turning from OFF to LOW/IGN on Piezoelectric spark models. (“HIGH/IGN”: In case of FA40 series) Keep the valve knob depressed for at least 30 seconds after lighting the burner. After 30 seconds release the valve knob. If the burner does not stay lit, repeat the lighting procedure. When the burner is lit, turn gas valve knob counterclockwise  to the desired setting. (All models, except FA40 series). SHUTDOWN INSTRUCTIONS WARNING: Motor and fan must be running before lighting, during operation and at shutdown,in order to prevent a flame-out condition that could result in personal injury or property damage. Turn gas valve knob clockwise to OFF position. Turn gas supply OFF by turning Propane tank valve clockwise  to close. Disconnect the power cord once the heater has cooled to ambient temperature. TEST FIRING HEATER Test fire your construction heater, following the lighting instructions applicable to the gas control system employed. Leak test all gas connections with a soap solution. Soap bubbles indicate gas leakage. DO NOT use a match or flame to test for gas leaks. STORAGE Never store a Propane gas tank inside a building or in the vicinity of any gas or oil-burning appliance. When the Propane tank is not disconnected from the construction heater, the gas tank and heater must be stored outdoors in a well-ventilated area, out of the reach of children. If for any reason the heater is to be stored indoors, the tank must be disconnected and stored outdoors in a well-ventilated area out of reach of children, in accordance with the standard for the Storage and Handling of Liquefied Petroleum Gases, ANSI / NFPA 58, and CSA B149.1, Natural Gas and Propane  Installation Code. The plastic tank valve plug supplied with your tank must be tightly installed when the tank is disconnected from the heater. MAINTENANCE INSTRUCTIONS Turn the unit off, allow the heater to fully cool, and disconnect the propane hose before performing any Maintenance functions. Unplug the unit from the 120V receptacle. Keep the unit clean and keep the inside of the torpedo housing debris free. Have the unit checked by a qualified technician at least once a year, preferably prior to the heatin season. REPLACEMENT PARTS Warning: Use only original replacement parts. This Heater must use design-specific parts. Do not substitute or use generic parts. Improper replacement parts could cause serious or fatal injuries. This will also protect your warranty coverage for parts replaced under warranty. Parts warranty and non-warranty: Contact authorized dealers of this product. If they can not supply original replacement part(s), either contact your nearest Parts  Central or GHP Group Inc., Technical Service Department at 1-877-447-4768. When calling GHP Group Inc., have ready: your name your address how heater was malfunctioning serial number of heater model number of heater replacement part number TROUBLESHOOTING PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION 1. Control dial is oﬀ and unit is clicking/ticking 1. This heater uses a continuous spark ignition system. This unit will continue to make a clicking/ticking sound at all times before ignition, after ignition and during operation, regardless of valve knob positioning. 1. No corrective action is needed. 2. The unit is ticking/clicking while the heater is lit. 1. This heater uses a continuous spark ignition system. This unit will continue to make a clicking/ticking sound at all times before ignition, after ignition and during operation, regardless of valve knob positioning. 1. No corrective action is needed. 3. Fan does not turn when electrical connection is made. 1. No electric power to heater. 2. Fan blade contacts inside of heater housing. 3. Fan blade(s) bent 4. Fan motor defective. 1. Check current to an electric outlet. If voltage is correct, check the power cord and extension cord for 2. Be sure that housing is not damaged. Make sure there are no obstructions to the fan. 3. Straighten blade(s) to match others. 4. Replace motor. 4. Heater will not fire. 1.    No spark at ignitor. 2.    Improper spark gap. 3.    Bad electrode. 1Check ignitor wire. Re-­‐attach or tighten if loose. Check Spark module. Replace if necessary. 2Set gap (See specifications for gap). 3. Replace Spark Plug. 5. Heater quits while running. 1. Internal temperature too high causing the limit switch to shut down the operation. 2. Damaged Control Valve. 3. Dust or debris build-­‐up inside of the heater. 1. If the output of the heater is restricted, the internal temperature becomes too high. Move the heater away from any obstructions. 2. Replace Control Valve. 3. Clean the inside of the heater. Always be sure to follow proper maintenance procedures, by cleaning the heater once per month during regular usage, and check spark gap at least once per season. WIRING DIAGRAMS PIEZO/MANUAL SPARK MODELS MANUELLE MODELOS DE CHISPA MANUAL O PIEZOELCTRICA WIRING DIAGRAMS REPLACEMENT PARTS LIST MODELS: FA40 Series FA50 Series FA60 Series REPLACEMENT PARTS LIST  ITEM No. DESCRIPTION  QTY PART NUMBER 40 SERIES 50 SERIES 60 SERIES 1 INNER SHELL ASSEMBLY 1 2304818 2304818 2304818 2 NOZZLE 1 *2304829 *2304942 *2325121 3 FLAME CAP 1 2304819 2304819 2325120 4 THERMAL SWITCH BRACKET 1 2304826 2304826 2304826 5 THERMAL SWITCH 1 2201373 2201563 2201599 6 NOZZLE NUT 1 2304578 2304578 2304578 7 SPARK PLUG ASSEMBLY 1 2201375 2201375 2206033 8 THERMOCOUPLE ASSEMBLY (1130/1474-­‐425L) 1 2304885 2304885 2304885 9 GAS TUBING ASSEMBLY 1 2304830 2304830 2304830  10 OUTER SHELL -­‐ ORANGE 1 2305403 2305403 2305403 OUTER SHELL -­‐ BLACK 1 2315915 2315915 2315915 OUTER SHELL -­‐ GRAY 1 2315956 2315956 2315956 OUTER SHELL -­‐ BLUE 1 2315312 2315312 2315312 11 CORD WRAP (select models only) 2 N/A N/A N/A 12 HANDLE ASSEMBLY -­‐ BLACK 1 2101447 2101447 2101447 HANDLE ASSEMBLY -­‐ GRAY 1 2305426 2305426 2305426 12.1 SCREW -­‐ HANDLE FRONT 1 2001355 2001355 2001355 12.2 SCREW -­‐ HANDLE FRONT 1 2001077 2001077 2001077 12.3 NUT -­‐ HANDLE REAR 1 2000384 2000384 2000384 13 MOTOR SUPPORT 1 2304823 2304823 2304823 13.1 MOTOR -­‐ MOUNTING BOLT 2 2001332 2001332 2001332 13.2 SLEEVE 1 2304949 2304949 2304949 14 MOTOR ASSEMBLY 1 2305909 2305447 2304547 14.1 MOTOR -­‐ FAN 1 2304821 2304821 2304821 15 FAN GUARD -­‐ BLACK 1 2304828 2304828 2304828 FAN GUARD -­‐ GRAY 1 2305411 2305411 2305411 16 MOTOR BRACKET 1 2304937 2304937 2304937 17 VALVE -­‐ GAS 1 GS22 (FA40) GS22A(FA60) GS22A(FA60) 18 PRESSURE SWITCH 1 N/A N/A N/A 19 VALVE BRACKET 1 2304624 2304624 2304624 20 BASE ASSEMBLY -­‐ BLACK 1 2304923 2304923 2304923 BASE ASSEMBLY -­‐ GREY 1 2305405 2305405 2305405 21 POWER CORD ASSEMBLY 1 2201368 2101670 2101670 22 GAS CONNECTOR INLET 1 2304831 2304831 2304831 23 CAPACITOR 1 2201372 2201372 2201372 24 BASE LOWER -­‐BLACK 1 2304925 2304925 2304925 BASE LOWER -­‐ GREY 1 2305407 2305407 2305407 25 KNOB GAS VALVE -­‐ BLACK 1 2101451 2101451 2101451 KNOB GAS VALVE -­‐ ORANGE 1 2305466 2305466 2305466 26 HEIGHT CONTROLLER -­‐ BLACK 1 2304927 2304927 2304927 HEIGHT CONTROLLER -­‐ GREY 1 2305409 2305409 2305409 27 HEIGHT CONTROL SCREW -­‐ BLACK 1 2304510 2304510 2304510 HEIGHT CONTROL SCREW -­‐ ORANGE 1 2305467 2305467 2305467 28 LEAD WIRE ASSEMBLY 1 2201371 2201371 2201371 29 SPARK MODULE 1 N/A 2201391 2201391 30 PCB ASSEMBLY 1 2201369 2201369 2201369     31 REG &#38; HOSE ASSEMBLY -­‐ 10FT (3M) 1 KR-­‐106-­‐01(POL-­‐3000) KR-­‐106-­‐01(POL-­‐3000) KR-­‐106-­‐01(POL-­‐3000) REG &#38; HOSE ASSEMBLY -­‐ 10FT (3M) w/HANDWHEEL 1 KR-­‐106-­‐01(HW-­‐3000) KR-­‐106-­‐01(HW-­‐3000) KR-­‐106-­‐01(HW-­‐3000) REG &#38; HOSE ASSEMBLY (QCC) -­‐ 10FT (3M) 1 TYQ-­‐9C-­‐3000 TYQ-­‐10C-­‐3000 TYQ-­‐10C-­‐3000 REG &#38; HOSE ASSEMBLY -­‐15FT (4.6M) 1 KR-­‐106-­‐01(POL-­‐4600) KR-­‐106-­‐01(POL-­‐4600) KR-­‐106-­‐01(POL-­‐4600) REG &#38; HOSE ASSEMBLY -­‐15FT (4.6M) w/HAND WHEEL 1 KR-­‐106-­‐01(HW-­‐4600) KR-­‐106-­‐01(HW-­‐4600) KR-­‐106-­‐01(HW-­‐4600) REG &#38; HOSE ASSEMBLY (QCC) -­‐ 15FT (4.6M) 1 TYQ-­‐9C-­‐4572 TYQ-­‐10C-­‐4572 TYQ-­‐10C-­‐4572 * VERSION NOT SHOWN IN EXPLODED VIEW PROPANE CONSTRUCTION HEATER ILLUSTRATED / PARTS BREAKDOWN REPLACEMENT PARTS LIST  ITEM No.  DESCRIPTION  QTY PART NUMBER 100 SERIES 125 SERIES 150 SERIES 1 INNER SHELL ASSEMBLY 1 2304929 2304929 2304929 2 NOZZLE 1 *2304943 5030077 2304944 3 FLAME CAP 1 2304930 2325122 2304931 4 THERMAL SWITCH BRACKET 1 2304826 2315515 2001355 5 THERMAL SWITCH 1 2201373 2201373 2201373 6 NOZZLE NUT 1 2304578 2304945 2304945 7 SPARK PLUG ASSEMBLY 1 2201392 2206034 2201393 8 THERMOCOUPLE ASSEMBLY (1130/1474-­‐425L) 1 2304885 2304885 2304885 9 GAS TUBING ASSEMBLY 1 2304946 2325138 2304947   10 OUTER SHELL -­‐ ORANGE 1 N/A 2305971 N/A OUTER SHELL -­‐ BLACK 1 N/A N/A N/A OUTER SHELL -­‐ GRAY 1 2315916 2315916 2315916 OUTER SHELL -­‐ BLUE 1 N/A N/A N/A 11 CORD WRAP (select models only) 2 2101423 2101423 2101423 12 HANDLE ASSEMBLY -­‐ BLACK 1 2101447 2101447 2101447 HANDLE ASSEMBLY -­‐ GRAY 1 2305426 2305426 2305426 12.1 SCREW -­‐ HANDLE FRONT 1 2001355 2001355 2001355 12.2 SCREW -­‐ HANDLE FRONT 1 2001077 2001077 2001077 12.3 NUT -­‐ HANDLE REAR 1 2000384 2000384 2000384 13 MOTOR SUPPORT 1 2304823 2304823 2304823 13.1 MOTOR -­‐ MOUNTING BOLT 2 2001332 2001332 2001332 13.2 SLEEVE 1 2304949 2304949 2304949 14 MOTOR ASSEMBLY 1 2304548 2304548 2304548 14.1 MOTOR -­‐ FAN 1 2304936 2304936 2304936 15 FAN GUARD -­‐ BLACK 1 2304939 2304939 2304939 FAN GUARD -­‐ GRAY 1 2305412 2305412 2305412 16 MOTOR BRACKET 1 2304938 2304938 2304938 17 VALVE -­‐ GAS 1 GS22A(FA125) GS22A(FA125) GS22A(FA150) 18 PRESSURE SWITCH 1 2305976 2305976 2305976 19 VALVE BRACKET 1 2304624 2304624 2304624 20 BASE ASSEMBLY -­‐ BLACK 1 2304924 2304924 2304924 BASE ASSEMBLY -­‐ GREY 1 N/A 2403354 N/A 21 POWER CORD ASSEMBLY 1 2101673 2101673 2101673 22 GAS CONNECTOR INLET 1 2304831 2304831 2304831 23 CAPACITOR 1 2301390 2301390 2301390 24 BASE LOWER -­‐ BLACK 1 2304926 2304926 2304926 BASE LOWER -­‐ GREY 1 N/A 2403355 N/A 25 KNOB GAS VALVE -­‐ BLACK 1 2101451 2101451 2101451 KNOB GAS VALVE -­‐ ORANGE 1 N/A 2305466 N/A 26 HEIGHT CONTROLLER -­‐ BLACK 1 2304928 2304928 2304928 HEIGHT CONTROLLER -­‐ GREY 1 N/A 2403356 N/A 27 HEIGHT CONTROL SCREW -­‐ BLACK 1 2304510 2304510 2304510 HEIGHT CONTROL SCREW -­‐ ORANGE 1 N/A 2305467 N/A 28 LEAD WIRE ASSEMBLY 1 2201371 2201371 2201371 29 SPARK MODULE 1 2201391 2201391 2201391 30 PCB ASSEMBLY 1 2201369 2201369 2201369     31 REG &#38; HOSE ASSEMBLY -­‐ 10FT (3M) 1 GR-­‐109(POL-­‐3000) GR-­‐109(POL-­‐3000) GR-­‐109(POL-­‐3000) REG &#38; HOSE ASSEMBLY -­‐ 10FT (3M) w/HANDWHEEL 1 GR-­‐109(HW-­‐3000) GR-­‐109(HW-­‐3000) GR-­‐109(HW-­‐3000) REG &#38; HOSE ASSEMBLY(QCC) -­‐ 10FT (3M) 1 TYQ-­‐6D1-­‐3000 TYQ-­‐6D1-­‐3000 TYQ-­‐6E1-­‐3000 REG &#38; HOSE ASSEMBLY -­‐15FT (4.6M) 1 GR-­‐109(POL-­‐4600) GR-­‐109(POL-­‐4600) GR-­‐109(POL-­‐4600) REG &#38; HOSE ASSEMBLY -­‐15FT (4.6M) w/HAND WHEEL 1 GR-­‐109(HW-­‐4600) GR-­‐109(HW-­‐4600) GR-­‐109(HW-­‐4600) REG &#38; HOSE ASSEMBLY(QCC) -­‐15FT (4.6M) 1 TYQ-­‐6D1-­‐4572 TYQ-­‐6D1-­‐4572 TYQ-­‐6E1-­‐4572 *  VERSION  NOT  SHOWN  IN  EXPLODED  VIEW PROPANE CONSTRUCTION HEATER ILLUSTRATED / PARTS BREAKDOWN MODELS: RMC-FA100/DGP/DGP-01 RMC-FA125/DGP/DGP-01 LPFA125DGD REPLACEMENT PARTS LIST  ITEM No. DESCRIPTION  QTY PART NUMBER FA100DGP FA125DGP LPFA125DGD 1 INNER SHELL ASSEMBLY 1 2304929 2304929 2304929 2 NOZZLE 1 *2304943 5030077 5030077 3 FLAME CAP 1 2304930 2325122 2325122 4 THERMAL SWITCH BRACKET 1 2304826 2315515 2315515 5 THERMAL SWITCH 1 2201373 2201373 2201373 6 NOZZLE NUT 1 2304578 2304945 2304945 7 SPARK PLUG ASSEMBLY 1 2201392 2206034 2206034 8 THERMOCOUPLE ASSEMBLY (1130/1474-­‐425L) 1 2304885 2304885 2304885 9 GAS TUBING ASSEMBLY 1 2305975 2325137 2325137 10 OUTER SHELL -­‐ ORANGE 1 2305971 2305971 N/A OUTER SHELL -­‐ BLACK 1 N/A N/A 2403443 11 CORD WRAP 2 2101423 2101423 2101423 12 MOTOR SUPPORT 1 2304823 2304823 2304823 12.1 MOTOR -­‐ MOUNTING BOLT 2 2001332 2001332 2001332 12.2 SLEEVE 1 2304949 2304949 2304949 13 MOTOR ASSEMBLY 1 2304548 2304548 2304548 13.1 MOTOR -­‐ FAN 1 2304936 2304936 2304936 14 FAN GUARD -­‐ GRAY 1 2305412 2305412 N/A FAN GUARD -­‐ BLACK 1 N/A N/A 2304939 15 MOTOR BRACKET 1 2304938 2304938 2304938 16 BASE RIGHT SIDE 1 2306000 2306000 2306000 17 LEG HOLDER 2 2315002 2315002 2315002 18 CAPACITOR 1 2301390 2301390 2301390 19 PRESSURE SWITCH 1 2305976 2305976 2305976 20 POWER CORD ASSEMBLY 1 2101673 2101673 2101673 21 GAS CONNECTOR INLET 1 2304831 2304831 2304831 22 BASE BOTTOM 1 2315001 2315001 2315001 23 VALVE BRACKET 1 2305973 2305973 2305973 24 VALVE -­‐ GAS 1 GS22A(FA125) GS22A(FA125) GS22A(FA125) 25 BASE LEFT SIDE 1 2305999 2305999 2305999 26 KNOB GAS VALVE -­‐ ORANGE 1 2101588 2101588 N/A KNOB GAS VALVE -­‐ BLACK 1 N/A N/A 2101451 27 HEIGHT CONTROL SCREW -­‐ ORANGE 2 2315003 2315003 N/A HEIGHT CONTROL SCREW -­‐ BLACK 2 NA NA 2403444   28 REGULATOR &#38; HOSE ASSEMBLY -­‐ 10FT (3M) 1 GR-109(POL-3000) GR-109(POL-3000) GR-109(POL-3000) REGULATOR &#38; HOSE ASSEMBLY(QCC) -­‐ 10FT (3M) 1 N/A N/A TYQ-­‐6D1-­‐3000 REGULATOR &#38; HOSE ASSEMBLY -­‐15FT (4.6M) 1 GR-109(POL-4600) GR-109(POL-4600) GR-109(POL-4600) REGULATOR &#38; HOSE ASSEMBLY(QCC) -­‐15FT (4.6M) 1 N/A N/A TYQ-­‐6D1-­‐4572 29 LEG 1 2305972 2305972 2305972 30 LEAD WIRE ASSEMBLY 1 2201371 2201371 2201371 31 SPARK MODULE 1 2201391 2201391 2201391 32 PCB ASSEMBLY 1 2201369 2201369 2201369 *  VERSION  NOT  SHOWN  IN  EXPLODED  VIEW WARRANTY LIMITED WARRANTY: This limited warranty is extended to the original retail purchaser of this Forced Air/Convection/Radiant Heater and warrants against any defect in materials and workmanship for a period of one (1) year from the date of retail sale. GHP Group, Inc., at its option, will either provide replacement parts or replace or repair the unit, when properly returned to the retailer where purchased or one of our service centers as directed by GHP Group,  Inc., within one (1) year of retail purchase. (Shipping costs, labor costs, etc. are the responsibility of the purchaser.) DUTIES OF THE OWNER: This heating appliance must be operated in accordance with the written instructions furnished with this heater. This warranty shall not excuse the owner from properly maintaining this heater in accordance with the written instructions furnished with this heater. A bill of sale, canceled check or payment record must be kept to verify the purchase date and establish a warranty period. Original carton should be kept in case of warranty return of the unit. WHAT IS NOT COVERED: Damage resulting from use of improper fuel. Damage caused by misuse or use contrary to the owners manual and safety guidelines. Damage caused by a lack of normal maintenance. Fuses Use of non-standard parts or accessories. Damage caused in transit. Freight charges on warranty parts or heaters to and from the factory shall be the responsibility of the owner. This warranty does not imply or assume any responsibility for consequential damages that may result from t he uses, misuse, or lack of routine maintenance of this heating appliance. A cleaning fee and the cost of parts may be charged for appliance failures resulting from lack of maintenance. This warranty does not cover claims which do not involve defective workmanship or materials. FAILURE TO PERFORM GENERAL MAINTENANCE (INCLUDING CLEANING) WILL VOID THIS WARRANTY. THIS LIMITED WARRANTY IS GIVEN TO THE PURCHASER IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY OF FITNESS FOR A PARTICULAR PURPOSE. THE REMEDY PROVIDED IN THIS WARRANTY IS EXCLUSIVE AND IS GRANTED IN LIEU OF ALL OTHER REMEDIES. IN NO  EVENT WILL GHP GROUP, INC. BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you. CLAIMS HANDLED AS FOLLOWS: Contact your retailer and explain the problem. If the retailer is unable to resolve the problem, contact our Customer Service Dept. detailing the heater model, the problem, and proof of date of purchase. A representative will contact you. DO NOT RETURN THE HEATER TO GHP GROUP,INC. unless instructed by our Representative. This warranty gives you specific legal rights and you may also have other rights which vary from state to state. TO REGISTER THE WARRANTY ON YOUR HEATER, PLEASE FILL OUT THIS CARD COMPLETELY AND MAIL WITHIN 14 DAYS FROM DATE OF PURCHASE OR REGISTER ON-LINE AT www.ghpgroupinc.com NAME: ______________________________________ PHONE: (          ) __________________ EMAIL: ____________________________ ADDRESS: _________________________________ CITY: ______________________________ STATE: __________ ZIP: ____________ MODEL: ____________________ SERIAL #: _______________________________________ DATE PURCHASED: __________________ DEALER PURCHASED FROM: ____________________________________________ TYPE OF STORE: __________________________ CITY &#38; STATE WHERE PURCHASED: ______________________________________________ PRICE PAID: _______________________ Please Take a Minute To Give Us Your Answers To The Following Questions. All Responses Are Used Solely For Market Research And Are Held In Strict Confidence. Who primarily decided this purchase? □ Male   □ Female □  18-24   □ 25-39   □ 40-59   □ 60 and over Purpose of Purchase? _______________________________________________________________________________________________ Do you own any other portable heaters? □ Yes  □ No If yes, type____________________________brand_____________________ How do you intend to use your new heater? □ Construction Site  □ Farm  □Warehouse/Commercial  □ Garage/Outbuilding  □ Other How did you  become aware of this heater? □ In-Store Display  □ Newspaper Ad  □ Magazine Ad □ Friend/Relative □  TV Commercial □ Store Salesperson  □ Other  ___________________________ What made you select this heater? □ Style □ Size/Portability □ Price  □ Package  □ Brand  □ Other ___________________   Do you: □ own □ rent Would you recommend this heater to a friend? □  Yes □ No Please give us your  comments:________________________________________________________________________________________ THANK YOU FOR COMPLETING THIS FORM! Information will be held confidential. WARRANTY REGISTRATION IMPORTANT: We urge you to fill out your warranty registration card within fourteen (14) days of date of purchase. You can also register your warranty on the internet at www.ghpgroupinc.com. Complete the entire serial number. Retain this portion of the card for your records. GHP Group, Inc. 6440 W Howard St Niles, IL 60714-3302 Tel: (877) 447-4768 www.ghpgroupinc.com SAVE THIS CARD! Place Postage Stamp Here GHP Group, Inc. 6440 W Howard St Niles, IL 60714-3302 [...]<p><a class="btn btn-secondary understrap-read-more-link" href="https://usemanuals.com/dyna-glo/fa40dgp-01-heater/">Read More...</a></p>]]></description>
										<content:encoded><![CDATA[<p>&nbsp;</p>
<p><strong>PROPANE</strong><br />
<strong>CONSTRUCTION HEATER</strong></p>
<p>USER’S MANUAL AND OPERATING INSTRUCTIONS</p>
<table width="1110">
<tbody>
<tr>
<td width="147">Dyna-Glo™DELUX<br />
MODELS</td>
<td width="136">RMC-FA40DGD<br />
RMC-FA50DGD<br />
RMC-FA60DGD<br />
RMC-FA100DGD<br />
RMC-FA125DGD/LPFA125DGD<br />
RMC-FA150DGD</td>
<td width="305">(40,000 BTU/HR,                 FORCED – AIR)<br />
(30,000/50,000 BTU/HR,     FORCED – AIR)(30,000/60,000 BTU/HR,     FORCED – AIR)(70,000/100,000 BTU/HR,   FORCED – AIR)(70,000/125,000 BTU/HR,   FORCED – AIR)(120,000/150,000 BTU/HR, FORCED – AIR)</td>
</tr>
</tbody>
</table>
<table width="1113">
<tbody>
<tr>
<td width="147">Dyna-Glo™Pro MODELS:</td>
<td width="177">RMC-FA40/DGP/DGP-01 RMC-FA50/DGP/DGP-01 RMC-FA60/DGP/DGP-01 RMC-FA100/DGP/DGP-01 RMC-FAl25/DGP/DGP-01 LPFAl25H/LPFAl25H-01 RMC-FA150/DGP/DGP-01</td>
<td width="264">(40,000 BTU/HR, FORCED – AIR)<br />
(30,000/50,000 BTU/HR, FORCED – AIR) (30,000/60,000 BTU/HR, FORCED – AIR) (70,000/100,000 BTU/HR, FORCED – AIR) (70,000/125,000 BTU/HR, FORCED – AIR)(120,000/150,000 BTU/HR, FORCED -AIR)</td>
</tr>
</tbody>
</table>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/Dyna-Glo-FA40DGP-01-Propane-Construction-Heater-Warning.webp" /><strong>GENERAL HAZARD WARNING</strong></p>
<p>FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTIONS PROVIDED WITH  THIS HEATER, CAN RESULT IN  EATH,  SERIOUS BODILY INJURY AND PROPERTY LOSS, OR DAMAGE FROM THE HAZARDS OF FIRE, EXPLOSION, BURN.  ASPHYXIATION, CARBON MONOXIDE POISONING, AND/OR ELECTRICAL SHOCK.</p>
<p>ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD USE OR SERVICE THIS HEATER.</p>
<p>IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN INSTRUCTION MANUAL, LABELS, ETCETERA, CONTACT THE MANUFACTURER.</p>
<p>CONSUMER: Retain this manual for future reference.<br />
Questions, problems, missing parts? Before returning to your retailer, call our customer<br />
service department at 877-447-4768 8:30 a.m. – 4:30 pm CST, Monday – Friday<br />
or email us at <a href="mailto:customerservice@ghpgroupinc.com">customerservice@ghpgroupinc.com</a><br />
<a href="http://www.ghpgroupinc.com/" target="_blank" rel="noopener">www.ghpgroupinc.com</a><br />
Printed in China</p>
<p>IMLPFDG – GDK</p>
<p><strong><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/Dyna-Glo-FA40DGP-01-Propane-Construction-Heater-Warning.webp" />WARNING</strong>: FIRE, BURN, INHALATION, AND EXPLOSION HAZARD, KEEP SOLID COMBUSTIBLES, SUCH AS BUILDING  ATERIALS, PAPER, OR CARDBOARD, A SAFE DISTANCE AWAY FROM THE HEATER AS RECOMMENDED BY THE INSTRUCTIONS.<br />
NEVER USE THE HEATER IN SPACES THAT DO OR MAY CONTAIN VOLATILE OR AIRBORNE COMBUSTIBLES, OR PRODUCTS  SUCH AS GASOLINE, SOLVENTS, PAINT THINNERS, DUST PARTICLES, OR UNKNOWN CHEMICALS.</p>
<p><strong>CALIFORNIA PROPOSITION</strong> 65: Fuels used in gas or oil-fired appliances and the products of combustion of such fuels contain chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm. This product contains chemicals, including lead and lead compounds, known to the State of California to cause cancer, birth defects, or other reproductive harm. <strong>Wash hands after handling.</strong></p>
<p><strong><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/Dyna-Glo-FA40DGP-01-Propane-Construction-Heater-Warning.webp" />WARNING:</strong> Using this heater in a residential garage requires that the heater is positioned so that it is protected against any possible damage by a moving vehicle, etc. It must be positioned so that the base of the heater is no less than 18 in (450 mm) above the garage floor or 8 ft (2450 mm) in repair garages. The heater must be placed on a stable surface. Do not place it on a chair, ladder, etc. Raising the heater will reduce BUT NOT eliminate the possibility of lighting the vapor of any flammable liquids which may be improperly stored or accidentally spilled. If the smell of gasoline is present, DO NOT operate this heater until the area has been properly ventilated.</p>
<p><strong><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/Dyna-Glo-FA40DGP-01-Propane-Construction-Heater-Warning.webp" />WARNING</strong>: CONSTRUCTION HEATERS ARE NOT FOR USE IN GARAGES IN CANADA.</p>
<p><strong><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/Dyna-Glo-FA40DGP-01-Propane-Construction-Heater-Warning.webp" />WARNING</strong>: NOT FOR HOME OR RECREATIONAL VEHICLE USE.</p>
<p>NEVER LEAVE THE HEATER<br />
UNATTENDED WHILE BURNING!</p>
<p><strong>PROPANE CONSTRUCTION HEATER</strong></p>
<p><strong>DYNA-GLO PROPANE FORCED AIR CONSTRUCTION HEATERS</strong><br />
The heater is designed and approved for use as a construction heater under ANS Z83.7 CSA 2.14. It is hard to anticipate every use which may be made of this heater. <strong>CHECK WITH YOUR LOCAL FIRE SAFETY </strong><strong>AUTHORITY IF YOU HAVE QUESTIONS ABOUT APPLICATIONS. </strong>Other standards govern the use of fuel gases and heat-producing products in specific applications. Your local authority can advise you about these.</p>
<p><strong>IMPORTANT</strong>: READ THIS USER’S MANUAL CAREFULLY AND COMPLETELY BEFORE TRYING TO OPERATE OR SERVICE THIS  HEATER. IMPROPER USE OF THIS HEATER CAN CAUSE SERIOUS INJURY OR DEATH FROM FIRE, EXPLOSION, AND CARBON MONOXIDE POISONING.<br />
This is a direct-fired forced air construction heater for either indoor construction or outdoor use. Its intended use is primarily the temporary heating of buildings or structures under construction, alteration, or repair. All the products of combustion generated by the heater are forced through the heater and released into the area being heated. This heater operates at approximately 98%+ combustion efficiency but still produces a small amount of carbon monoxide. Humans can tolerate small amounts of carbon monoxide for short periods. Carbon monoxide can build up in a heated space and failure to provide adequate ventilation could result in poisoning or death.</p>
<p><strong><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/Dyna-Glo-FA40DGP-01-Propane-Construction-Heater-Warning.webp" />WARNING</strong>: NOT FOR USE WITH DUCTWORK.</p>
<p><strong>SPECIFICATIONS</strong></p>
<table width="1616">
<tbody>
<tr>
<td colspan="2" width="90"><strong><em> </em></strong><strong>Model No.</strong></td>
<td colspan="2" width="91"><strong>RMC-­‐FA40DGP/ DGP-­‐01</strong></td>
<td colspan="2" width="91"><strong><em> </em></strong><strong>FA50 Series</strong></td>
<td colspan="2" width="91"><strong><em> </em></strong><strong>FA60 Series</strong></td>
<td colspan="2" width="91"><strong>RMC-­‐FA100DGD/ DGP/DGP-­‐01</strong></td>
<td colspan="2" width="91"><strong>LPFA125DGD/ </strong><strong>RMC-­‐FA125DGP/ </strong><strong>DGP-­‐01</strong></td>
<td colspan="2" width="80"><strong>LPFA125H/H-­‐01/ </strong><strong>RMC-­‐FA125DGD</strong></td>
<td colspan="2" width="91"><strong><em> </em></strong><strong>RMC-­‐FA150DGD</strong></td>
</tr>
<tr>
<td colspan="2" width="90"><strong><em> </em></strong><strong>Input Rating</strong></td>
<td colspan="2" width="91"><strong><em> </em></strong>40,000 BTU/hr</td>
<td colspan="2" width="91">30,000 BTU/hr</p>
<p>50,000 BTU/hr</td>
<td colspan="2" width="91">30,000 BTU/hr</p>
<p>60,000 BTU/hr</td>
<td colspan="2" width="91">70,000 BTU/hr</p>
<p>100,000 BTU/hr</td>
<td colspan="2" width="91">70,000 BTU/hr</p>
<p>125,000 BTU/hr</td>
<td colspan="2" width="80">70,000 BTU/hr</p>
<p>125,000 BTU/hr</td>
<td colspan="2" width="91">120,000 BTU/hr</p>
<p>150,000 BTU/hr</td>
</tr>
<tr>
<td colspan="2" width="90"><strong><em> </em></strong><strong>Type of Gas</strong></td>
<td colspan="2" width="91"><strong><em> </em></strong>Propane</td>
<td colspan="2" width="91"><strong><em> </em></strong>Propane</td>
<td colspan="2" width="91"><strong><em> </em></strong>Propane</td>
<td colspan="2" width="91"><strong><em> </em></strong>Propane</td>
<td colspan="2" width="91"><strong><em> </em></strong>Propane</td>
<td colspan="2" width="80"><strong><em> </em></strong>Propane</td>
<td colspan="2" width="91"><strong><em> </em></strong>Propane</td>
</tr>
<tr>
<td colspan="2" width="90"><strong><em> </em></strong><strong>Gas Supply </strong><strong>Pressure to Regulator Maximum</strong></td>
<td colspan="2" width="91"><strong><em> </em></strong>Cylinder Pressure</td>
<td colspan="2" width="91"><strong><em> </em></strong>Cylinder Pressure</td>
<td colspan="2" width="91"><strong><em> </em></strong>Cylinder Pressure</td>
<td colspan="2" width="91"><strong><em> </em></strong>Cylinder Pressure</td>
<td colspan="2" width="91"><strong><em> </em></strong>Cylinder Pressure</td>
<td colspan="2" width="80"><strong><em> </em></strong>Cylinder Pressure</td>
<td colspan="2" width="91"><strong><em> </em></strong>Cylinder Pressure</td>
</tr>
<tr>
<td colspan="2" width="90"><strong><em> </em></strong><strong>Minimum</strong> <strong>(for purpose of Input Adjustment)</strong></td>
<td colspan="2" width="91"><strong><em> </em></strong>5psig</td>
<td colspan="2" width="91"><strong><em> </em></strong>5psig</td>
<td colspan="2" width="91"><strong><em> </em></strong>5psig</td>
<td colspan="2" width="91"><strong><em> </em></strong>5psig</td>
<td colspan="2" width="91"><strong><em> </em></strong>5psig</td>
<td colspan="2" width="80"><strong><em> </em></strong>5psig</td>
<td colspan="2" width="91"><strong><em> </em></strong>5psig</td>
</tr>
<tr>
<td colspan="2" width="90"><strong><em> </em></strong><strong>Manifold</strong> <strong>Pressure</strong></td>
<td colspan="2" width="91"><strong><em> </em></strong>11″ W.C</td>
<td colspan="2" width="91"><strong><em> </em></strong>11″ W.C</td>
<td colspan="2" width="91"><strong><em> </em></strong>11″ W.C</td>
<td colspan="2" width="91"><strong><em> </em></strong>11″ W.C</td>
<td colspan="2" width="91"><strong><em> </em></strong>11″ W.C</td>
<td colspan="2" width="80"><strong><em> </em></strong>11″ W.C</td>
<td colspan="2" width="91"><strong><em> </em></strong>11″ W.C</td>
</tr>
<tr>
<td colspan="2" width="90"><strong><em> </em></strong><strong>Gas</strong> <strong>Consumption</strong></td>
<td width="44"><strong><em> </em></strong>1.9lbs/hr</td>
<td width="48"><strong><em> </em></strong>0.86 kg/hr</td>
<td width="44">1.4lbs/hr 2.3lbs/hr</td>
<td width="48">0.63 kg/hr</p>
<p>1.04 kg/hr</td>
<td width="44">1.4lbs/hr 2.8lbs/hr</td>
<td width="48">0.63 kg/hr</p>
<p>1.27 kg/hr</td>
<td width="45">3.3lbs/hr 4.6lbs/hr</td>
<td width="46">1.5 kg/hr</p>
<p>2.09 kg/hr</td>
<td width="45">3.3lbs/hr 5.8lbs/hr</td>
<td width="46">1.5 kg/hr</p>
<p>2.63 kg/hr</td>
<td width="39">3.3lbs/hr 5.8lbs/hr</td>
<td width="41">1.5 kg/hr</p>
<p>2.63 kg/hr</td>
<td width="44">5.6lbs/hr 7.0lbs/hr</td>
<td width="48">2.54 kg/hr 3,18 kg/hr</td>
</tr>
<tr>
<td colspan="2" width="90"><strong><em> </em></strong><strong>Electrical Input</strong></td>
<td colspan="2" width="91"><strong><em> </em></strong>120V, 60Hz, 1Ø</td>
<td colspan="2" width="91"><strong><em> </em></strong>120V, 60Hz, 1Ø</td>
<td colspan="2" width="91"><strong><em> </em></strong>120V, 60Hz, 1Ø</td>
<td colspan="2" width="91"><strong><em> </em></strong>120V, 60Hz, 1Ø</td>
<td colspan="2" width="91"><strong><em> </em></strong>120V, 60Hz, 1Ø</td>
<td colspan="2" width="80"><strong><em> </em></strong>120V, 60Hz, 1Ø</td>
<td colspan="2" width="91"><strong><em> </em></strong>120V, 60Hz, 1Ø</td>
</tr>
<tr>
<td width="45"><strong><em> </em></strong><strong>Amperage</strong></td>
<td width="45"><strong><em> </em></strong><strong>Load</strong></td>
<td colspan="2" width="91">0.68amps</td>
<td colspan="2" width="91"><strong><em> </em></strong>0.65amps</td>
<td colspan="2" width="91"><strong><em> </em></strong>0.65amps</td>
<td colspan="2" width="91"><strong><em> </em></strong>0.7amps</td>
<td colspan="2" width="91"><strong><em> </em></strong>0.7amps</td>
<td colspan="2" width="80"><strong><em> </em></strong>0.7amps</td>
<td colspan="2" width="91"><strong><em> </em></strong>0.7amps</td>
</tr>
<tr>
<td width="45"><strong><em> </em></strong></p>
<p><strong>Fan</strong></td>
<td width="45"><strong>Unload</strong> <strong>Load</strong></td>
<td colspan="2" width="91">3550rpm 3000rpm</td>
<td colspan="2" width="91">3570rpm 3300rpm</td>
<td colspan="2" width="91">3570rpm 3300rpm</td>
<td colspan="2" width="91">3580rpm 3300rpm</td>
<td colspan="2" width="91">3580rpm 3300rpm</td>
<td colspan="2" width="80">3580rpm 3300rpm</td>
<td colspan="2" width="91">3580rpm 3300rpm</td>
</tr>
<tr>
<td colspan="2" width="90"><strong><em> </em></strong><strong>Ignition</strong></td>
<td colspan="2" width="91"><strong><em> </em></strong>Piezo/Manual Spark</td>
<td colspan="2" width="91"><strong><em> </em></strong>Continuous Spark</td>
<td colspan="2" width="91"><strong><em> </em></strong>Continuous Spark</td>
<td colspan="2" width="91"><strong><em> </em></strong>Continuous Spark</td>
<td colspan="2" width="91"><strong><em> </em></strong>Continuous Spark</td>
<td colspan="2" width="80"><strong><em> </em></strong>Continuous Spark</td>
<td colspan="2" width="91"><strong><em> </em></strong>Continuous Spark</td>
</tr>
<tr>
<td colspan="2" width="90"><strong><em> </em></strong><strong>Spark Gap</strong></td>
<td colspan="2" width="91"><strong><em> </em></strong>0.16″ (4mm)</td>
<td colspan="2" width="91"><strong><em> </em></strong>0.16″ (4mm)</td>
<td colspan="2" width="91"><strong><em> </em></strong>0.16″ (4mm)</td>
<td colspan="2" width="91"><strong><em> </em></strong>0.16″ (4mm)</td>
<td colspan="2" width="91"><strong><em> </em></strong>0.16″ (4mm)</td>
<td colspan="2" width="80"><strong><em> </em></strong>0.16″ (4mm)</td>
<td colspan="2" width="91"><strong><em> </em></strong>0.11″ (2.8mm)</td>
</tr>
<tr>
<td colspan="2" width="90"><strong><em> </em></strong><strong>Size (LxWxH)</strong></td>
<td colspan="2" width="91"><strong><em> </em></strong>19.3″x8.3″x15.2″ (49.0×21.1×38.6)cm</td>
<td colspan="2" width="91"><strong><em> </em></strong>19.3″x8.3″x15.2″ (49.0×21.1×38.6)cm</td>
<td colspan="2" width="91"><strong><em> </em></strong>19.3″x8.3″x15.2″ (49.0×21.1×38.6)cm</td>
<td colspan="2" width="91">25.6″x12.7″x15.6″ (65.0×32.3×39.6)cm 25.6″x11.8″x16.1″ (65.0×30.0&#215;40.9)cm</td>
<td colspan="2" width="91">26.6″x13.0″x17.3″ (67.6×33.0&#215;43.9)cm 25.6″x11.8″x16.1″ (65.0×30.0&#215;40.9)cm</td>
<td colspan="2" width="80">26.2″x11.8″x17.2″ (66.6×30.0&#215;43.6)cm 25.6″x11.8″x16.1″ (65.0×30.0&#215;41.0)cm</td>
<td colspan="2" width="91"><strong><em> </em></strong>25.6″x11.8″x16.1″ (65.0×30.0&#215;40.9)cm</td>
</tr>
</tbody>
</table>
<p><strong>PROPANE CONSTRUCTION HEATER</strong></p>
<p>GENERAL SAFETY INSTRUCTION<br />
Accidents are always tragic especially because so many of them could have been prevented with little care and judgment. There are some basic good practices, we hope you will follow for safe use of your heater.</p>
<p><strong>IMPORTANT SAFETY INSTRUCTION</strong></p>
<ul>
<li>Children should be carefully supervised when they are in the area.</li>
<li>Always maintain proper clearance from combustible materials. Minimum clearance from combustibles: Side – 24” (61 cm); Top – 36” (92 cm); Front – 72” (183 cm). Floor – combustible. Not for use on finished floors.</li>
<li>Heater must be placed on a level and stable surface.</li>
<li>Never place anything including clothes or other flammable items on the heater.</li>
<li>The appliance area shall be kept clear and free from combustible materials, gasoline, and other flammable vapors and liquids.</li>
<li>Do not modify or operate a heater that has been modified.</li>
<li>Adequate clearance for accessibility and for combustion &amp; ventilation air supply must be maintained at all times when the heater is operating.</li>
<li>Service and repair should be done by a qualified service person. The heater should be inspected before each use and at least annually by a qualified person. More frequent cleaning may be required as necessary. Do not service while hot or operating.</li>
<li>Never connect the heater to an unregulated gas supply.</li>
<li>The heater is shipped from the factory for LP(Propane) gas. This heater is for use with propane gas only, do not convert the heater to any other gas. Installation must conform to local codes or, in the absence of local codes, with the standard for the Storage and Handling of Liquefied Petroleum Gases ANSI/NFPA 58 and the Natural Gas and Propane Installation Code CSA B149.1</li>
<li>The minimum and maximum inlet pressures to the regulator from the gas tank are 5 psi and bottle pressure, respectively. Use only the regulator &amp; hose assembly provided with the heater. Inspect the regulator/hose assembly prior to each use of the heater. If there is excessive abrasion or wear, or the hose is cut, replace it with the regulator/hose assembly listed on the parts list prior to using this heater.</li>
<li>Gas supply connections should be checked using a 50/50 solution of liquid dish soap and never use a flame to check for gas leaks.</li>
<li>The electrical connection &amp; grounding must comply with National Electrical Code. ANSI/NFPA 70 or in Canada CSA C22.1, Canadian Electrical Code, Part 1. Use only a properly grounded three (3) prong receptacle.</li>
<li>Do not restrict inlet or outlet by any means. The flow of combustion and ventilation air is not to be obstructed.</li>
<li>This heater should not be directed toward any propane-gas container within 20 ft (6M). The heater must be located at least 6 ft. (1.83 m) in the U.S.; or (ii) 10 ft. (3 m) in Canada, from any propane gas container.</li>
<li>The propane cylinder supply system must be arranged to provide for vapor withdrawal from the operating cylinder.</li>
<li>This heater is not to be used with external thermostats, timers, or other devices that control or alter the electrical supply to the heater.</li>
</ul>
<p><strong><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/Dyna-Glo-FA40DGP-01-Propane-Construction-Heater-Warning.webp" />WARNING</strong>: Motor and fan must be running before lighting, during operation, and at shutdown, in order to prevent a flame-out condition that could result in personal injury or property damage.</p>
<p><strong>PRODUCT FEATURES</strong></p>
<ul>
<li>Portable &amp; Stable</li>
<li>Wind Resistant &amp; Rain Protected</li>
<li>Continuous Spark Ignition or  Piezo Electric Spark Ignition</li>
<li>100% Safety Shutoff System</li>
<li>Continuous Adjustable Input Ratings (Except FA40)</li>
</ul>
<p><strong>UNPACKING HEATER</strong></p>
<ol>
<li>Remove the heater from the carton.</li>
<li>Remove all protective packing applied to the heater for shipment.</li>
<li>Retain cartons and packaging material until the unit is operated and found in good condition.</li>
<li>Check the heater for any shipping damage. If the heater shows any external or internal damage, promptly inform the dealer/distributor where you purchased the heater.</li>
</ol>
<p><strong>Assembly Components and Instructions for Steel Base Units:</strong></p>
<table width="1196">
<tbody>
<tr>
<td width="200">Tools required for assembly:<br />
All Models: Adjustable Wrench<br />
FA100 – FA150: Phillips Head Screw Driver</td>
<td width="200">Contents:<br />
All Models: Unit, Manual, Hose and Regulator Assembly<br />
FA100 – FA150 Series Includes: 2 Cord Wrap Attachments, 4 Screws (ST3.5×10)</td>
<td width="200">Assembly Time: 5 Minutes</td>
</tr>
</tbody>
</table>
<p><strong>1. Assembling the Cord Wrap Attachments: (FA100 – FA150 Series Only)</strong></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/Dyna-Glo-FA40DGP-01-Propane-Construction-Heater-UNPACKING-HEATER.webp" /></p>
<p><strong>Parts Required:</strong><br />
4 Screws (ST3.5×10), and 2 Cord Wrap Attachments<br />
Place the cord wrap attachment as shown, then use Phillips screwdriver to tighten the screws and secure the cord wrap attachments.</p>
<p><strong>2. Regulator and Hose Connection: (All Models)</strong></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/Dyna-Glo-FA40DGP-01-Propane-Construction-Heater-Regulator-and-Hose-Connection.webp" /></p>
<p>See figure on right. Connect the hose tightly to the heater using a wrench. Please also refer to page 8 in the manual.</p>
<p><strong>Assembly Components and Instructions for Plastic Base Units:</strong></p>
<p>Tools required for assembly: All Models: Adjustable Wrench FA125 Series: Phillips Head Screw Driver</p>
<p><strong>Contents:</strong><br />
All Models: Unit, Manual, Hose and Regulator Assembly, Adjustable Leg, 2 Height Control Screws FA125 Series Includes: 2 Cord Wrap Attachments, 4 Screws (ST3.5×10)</p>
<p><strong>Assembly Time</strong>: 5 Minutes</p>
<p><strong>1. Assemble the Leg:</strong></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/Dyna-Glo-FA40DGP-01-Propane-Construction-Heater-Assemble-the-Leg.webp" /></p>
<p><strong>2. Assemble the Height Control Screw:</strong></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/Dyna-Glo-FA40DGP-01-Propane-Construction-Heater-Height-Control-Screw.webp" /></p>
<p><strong>Parts Required</strong>: Height Control Screw 2 pcs<br />
Turn the Height Control Screw clockwise to lock it. Turn the Height Control Screw counterclockwise to unlock it.</p>
<p><strong>3. Assembling the Cord Wrap Attachments:</strong></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/Dyna-Glo-FA40DGP-01-Propane-Construction-Heater-Cord-Wrap-Attachments.webp" /><strong>Parts Required:</strong> 4 Screws (ST3.5X10) and 2 Cord Wrap Attachments<br />
Place the cord wrap attachments as shown, then use a Phillips screwdriver to tighten the screws and secure the cord wrap attachments.</p>
<p><strong>4. Regulator and Hose Connection:</strong></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/Dyna-Glo-FA40DGP-01-Propane-Construction-Heater-Regulator.webp" /></p>
<p>See figure on right.<br />
Connect the hose tightly to the heater using a wrench.  Please also refer to page 8 in the manual.</p>
<p><strong>INFORMATION ON SIZE * CAPACITY OF PROPANE GAS CYLINDERS:</strong></p>
<p>The chart below shows the number and size of propane tanks needed to run this heater.<br />
*Less gas is vaporized at lower temperatures.<br />
You may need two or more 100 pounds (45 kg) tanks or one larger tank in colder weather. (See the parts list for your model of heater to get the specified regulator assembly.)</p>
<table width="1123">
<tbody>
<tr>
<td rowspan="2" width="88">Temperature (°F-°C) at tank</td>
<td colspan="3" width="511">Number of Tanks</td>
</tr>
<tr>
<td width="166">40,000-60,000 BTU/h</td>
<td width="169">100,000 -125,000 BTU/h</td>
<td width="176">150,000 BTU/h</td>
</tr>
<tr>
<td width="88">Above</p>
<p>32°F (0°C)</td>
<td width="166">1 – 20lb (9kg)</td>
<td width="169">2 – 100lb (45kg)</td>
<td width="176">2 – 100lb (45kg)</td>
</tr>
<tr>
<td width="88">32°F (0°C)</td>
<td width="166">1 – 20lb (9kg)</td>
<td width="169">2 – 100lb (45kg)</td>
<td width="176">2 – 100lb (45kg)</td>
</tr>
<tr>
<td width="88">20°F (-7°C)</td>
<td width="166">1 – 20lb (9kg)</td>
<td width="169">2 – 100lb (45kg)</td>
<td width="176">3 – 100lb (45kg)</td>
</tr>
<tr>
<td width="88">10°F (-12°C)</td>
<td width="166">1 – 20lb (9kg)</td>
<td width="169">3 – 100lb (45kg)</td>
<td width="176">3 – 100lb (45kg)</td>
</tr>
<tr>
<td width="88">-10°F (-23°C)</td>
<td width="166">2 – 20lb (9kg)</td>
<td width="169">Use Larger Tank</td>
<td width="176">Use Larger Tank</td>
</tr>
<tr>
<td width="88">-20°F (-29°C)</td>
<td width="166">1 – 100lb (45kg)</td>
<td width="169">Use Larger Tank</td>
<td width="176">Use Larger Tank</td>
</tr>
</tbody>
</table>
<p><strong>The propane (LP) gas tank must also be equipped with the following:</strong></p>
<ul>
<li>A collar to protect the Propane gas valve.</li>
<li>A shutoff valve terminating a Propane gas cylinder valve outlet as specified in the American National Standards for Compressed Gas Cylinder Valve  Outlets and Inlet Connections.</li>
<li>A safety relief valve having direct communications with the vapor space of the tank.</li>
<li>An arrangement of vapor withdrawal.</li>
</ul>
<p><strong>The propane (LP) gas pressure regulator and hose assembly supplied with this heater must be used without alteration.</strong></p>
<p>The hose assembly shall be visually inspected prior to each use of the heater. If it is evident that there is excessive abrasion or wear, or the hose is cut, it must be replaced prior to the heater being put into operation. The replacement hose assembly shall be that specified by the manufacturer.</p>
<p><strong>INSTALLATION TO THE PROPANE GAS TANK</strong></p>
<p><strong>IMPORTANT</strong>: You must use a propane/LP gas supply cylinder that is compatible with the connection device provided with the hose and regulator.</p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/Dyna-Glo-FA40DGP-01-Propane-Construction-Heater-propaneLP-gas.webp" /></p>
<ol>
<li>Provide propane/LP supply system. Ensure that the valve on the cylinder is fully closed by turning the knob fully clockwise ( <img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/Dyna-Glo-FA40DGP-01-Propane-Construction-Heater-Icon.webp" /> ). Ensure that the cylinder is fully upright for vapor withdrawal. (see size/capacity, page 7).</li>
<li>Connect a hose to heater inlet. Tighten firmly using a wrench. You must use the regulator supplied with the heater</li>
<li>Connect fuel gas fitting hose/regulator assembly to propane LP tank(s). 3a. For units with a POL fitting (see figure 1) turn fuel fitting counterclockwise into threads on the tank. Tighten firmly using a wrench. Some models have a handwheel that can be used to tighten the fitting. This handwheel can be slid off of the nut so that a wrench can also be used to tighten the fitting. IMPORTANT: Position the regulator so that hose leaving the regulator is in a horizontal position. 3b. For units with a QCC fitting (see figure 2) turn QCC gas fitting clockwise onto threads on the tank. Tighten firmly using your hand (DO NOT USE A WRENCH). IMPORTANT: Position the regulator so that the regulator vent is pointing down toward the floor and the arrow on the regulator is visible.</li>
<li>Open propane/LP supply valve on propane/LP tank(s) slowly. NOTE: If not opened slowly, the excess flow device in the regulator may stop gas flow. If this happens, close the propane/LP supply valve, wait one minute (or until you hear a click), and open again slowly.</li>
<li>Check all connections for leaks. Apply a 50/50 solution of liquid dish soap and water to gas joints. Bubbles forming show a leak that must be corrected.</li>
<li>Close propane / LP supply valve before attempting to repair the connection.</li>
</ol>
<p><strong><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/Dyna-Glo-FA40DGP-01-Propane-Construction-Heater-Warning.webp" />WARNING</strong>: Purging and filling of LP gas tanks must be performed by personnel who has been thoroughly trained in accepted LP gas industry procedures. Failure to follow these instructions may result in an explosion, fire, severe personal injury, or death.</p>
<p><strong>REFILLING THE PROPANE GAS TANK</strong></p>
<p><strong>ALL NEW CYLINDERS MUST BE PURGED BEFORE THE FIRST FILLING.</strong></p>
<ul>
<li>Turn heater gas valve knob and gas tank valve to OFF position.</li>
<li>Propane tank valve equipped with the old style fitting has LEFT HANDED THREADS. Turn POL fitting<br />
CLOCKWISE to loosen. Protect POL fitting when disconnected from the tank. Have tank filled by your local Propane gas supplier.</li>
<li>Fasten full Propane tank and connect POL fitting to tank valve by turning COUNTERCLOCKWISE.</li>
<li>With heater gas valve knob still in the OFF position, turn ON tank valve and check for leaks with soap solution.</li>
</ul>
<p><strong>PROPANE SAFETY</strong></p>
<p>Propane is safe to use when properly handled. Careless handling of the Propane gas tank could result in fire and/or an explosion. Therefore:</p>
<ul>
<li>Always keep tank/cylinder securely fastened in an upright position.</li>
<li>Avoid tipping tank on its side when connected to a regulator since this may cause damage to diaphragm in regulator.</li>
<li>Handle valves with care.</li>
<li>Never connect an unregulated Propane tank to construction heater.</li>
<li>Do not subject Propane tank to excessive heat.</li>
<li>Tightly close the gas shutoff valve on the Propane tank after each use.</li>
<li>The POL fitting must be protected when disconnected from the propane tank.</li>
<li>Never store a Propane gas tank inside a building or in the vicinity of any gas burning appliance.<br />
<strong>THE DISCONNECTED TANK MUST NEVER BE STORED IN A BUILDING, GARAGE OR ANY OTHER ENCLOSED</strong><strong> AREA.</strong></li>
</ul>
<p><strong>LEAK CHECKING</strong><br />
Check all gas connections with a soap solution to be sure they are tight and leak proof.</p>
<ul>
<li>The installation of your heater must meet all local codes and/or gas utility requirements or, in the absence of local codes, with the Storage and Handling of Liquefied Petroleum Gases, ANSI/ NFPA 58 and the Natural and Propane Installation Code, CSA B149.1.</li>
<li>The minimum clearances to combustible construction: Side – 24” (61 cm); Top – 36” (92 cm); Front – 72” (183 cm); Floor – combustible, must be maintained at all times.</li>
<li>The hose assembly should be visually inspected prior to each use of the heater. If it is evident that there is excessive abrasion or wear, or the hose is cut, it must be replaced prior to the heater being put into operation.</li>
<li>The replacement hose assembly shall be that specified by the manufacturer (Refer to parts list).</li>
</ul>
<p><strong>LIGHTING INSTRUCTIONS</strong></p>
<p><strong>WARNING</strong>: Motor and fan must be running before lighting, during operation and shutdown, in order to prevent a flame-out condition which could result in personal injury or property damage.<br />
<strong>NOTE</strong>: This heater uses a continuous spark ignition system. This unit will continue to make a clicking/ ticking sound at all times before ignition, after ignition, and during operation, regardless of valve knob positioning.</p>
<ol>
<li> Connect the power cord to a properly grounded three (3) prong 120V, 60Hz, single-phase receptacle.</li>
<li>Turn gas valve knob clockwise <img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/Dyna-Glo-FA40DGP-01-Propane-Construction-Heater-Icon.webp" /> to OFF position.</li>
<li>Wait five (5) minutes to clear any gas. Then smell for gas, if you don’t smell gas, go to the next step.</li>
<li>Turn gas supply ON by turning Propane tank valve counterclockwise <img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/Dyna-Glo-FA40DGP-01-Propane-Construction-Heater-Icon-2.webp" /> .</li>
<li>Push in and turn gas control knob counterclockwise<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/Dyna-Glo-FA40DGP-01-Propane-Construction-Heater-Icon-2.webp" />  to “LOW/IGN”. This will light the burner. If needed, keep pressing the control knob until the burner lights and keep depressing and turning from OFF to LOW/IGN on Piezoelectric spark models. (“HIGH/IGN”: In case of FA40 series)</li>
<li>Keep the valve knob depressed for at least 30 seconds after lighting the burner. After 30 seconds release the valve knob.</li>
<li>If the burner does not stay lit, repeat the lighting procedure.</li>
<li>When the burner is lit, turn gas valve knob counterclockwise<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/Dyna-Glo-FA40DGP-01-Propane-Construction-Heater-Icon-2.webp" />  to the desired setting. (All models, except FA40 series).</li>
</ol>
<p><strong>SHUTDOWN INSTRUCTIONS</strong></p>
<p><strong><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/Dyna-Glo-FA40DGP-01-Propane-Construction-Heater-Warning.webp" />WARNING</strong>: Motor and fan must be running before lighting, during operation and at shutdown,in order to prevent a flame-out condition that could result in personal injury or property damage.<br />
Turn gas valve knob clockwise <img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/Dyna-Glo-FA40DGP-01-Propane-Construction-Heater-Icon.webp" /> to OFF position.<br />
Turn gas supply OFF by turning Propane tank valve clockwise<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/07/Dyna-Glo-FA40DGP-01-Propane-Construction-Heater-Icon.webp" />  to close.<br />
Disconnect the power cord once the heater has cooled to ambient temperature.</p>
<p><strong>TEST FIRING HEATER</strong></p>
<p>Test fire your construction heater, following the lighting instructions applicable to the gas control system employed. Leak test all gas connections with a soap solution. Soap bubbles indicate gas leakage. DO NOT use a match or flame to test for gas leaks.</p>
<p><strong>STORAGE</strong></p>
<p>Never store a Propane gas tank inside a building or in the vicinity of any gas or oil-burning appliance. When the Propane tank is not disconnected from the construction heater, the gas tank and heater must be stored outdoors in a well-ventilated area, out of the reach of children. If for any reason the heater is to be stored indoors, the tank must be disconnected and stored outdoors in a well-ventilated area out of reach of children, in accordance with the standard for the Storage and Handling of Liquefied Petroleum Gases, ANSI / NFPA 58, and CSA B149.1, Natural Gas and Propane  Installation Code. The plastic tank valve plug supplied with your tank must be tightly installed when the tank is disconnected from the heater.</p>
<p><strong>MAINTENANCE INSTRUCTIONS</strong></p>
<ol>
<li>Turn the unit off, allow the heater to fully cool, and disconnect the propane hose before performing any Maintenance functions. Unplug the unit from the 120V receptacle.</li>
<li>Keep the unit clean and keep the inside of the torpedo housing debris free.</li>
<li>Have the unit checked by a qualified technician at least once a year, preferably prior to the heatin season.</li>
</ol>
<p><strong>REPLACEMENT PARTS</strong></p>
<p>Warning: Use only original replacement parts. This Heater must use design-specific parts. Do not substitute or use generic parts. Improper replacement parts could cause serious or fatal injuries. This will also protect your warranty coverage for parts replaced under warranty. Parts warranty and non-warranty: Contact authorized dealers of this product. If they can not supply original replacement part(s), either contact your nearest Parts  Central or GHP Group Inc., Technical Service Department at 1-877-447-4768.</p>
<p>When calling GHP Group Inc., have ready:</p>
<ul>
<li>your name</li>
<li>your address</li>
<li>how heater was malfunctioning</li>
<li>serial number of heater</li>
<li>model number of heater</li>
<li>replacement part number</li>
</ul>
<p><strong>TROUBLESHOOTING</strong></p>
<table width="1192">
<tbody>
<tr>
<td width="157"><strong>PROBLEM</strong></td>
<td width="212"><strong>POSSIBLE CAUSE</strong></td>
<td width="257"><strong>CORRECTIVE ACTION</strong></td>
</tr>
<tr>
<td width="157">1. Control dial is oﬀ and unit is clicking/ticking</td>
<td width="212">1. This heater uses a continuous spark ignition system. This unit will continue to make a clicking/ticking sound at all times before ignition, after ignition and during operation, regardless of valve knob positioning.</td>
<td width="257">1. No corrective action is needed.</td>
</tr>
<tr>
<td width="157">2. The unit is ticking/clicking while the heater is lit.</td>
<td width="212">1. This heater uses a continuous spark ignition system. This unit will continue to make a clicking/ticking sound at all times before ignition, after ignition and during operation, regardless of valve knob positioning.</td>
<td width="257">1. No corrective action is needed.</td>
</tr>
<tr>
<td width="157">3. Fan does not turn when electrical connection is made.</td>
<td width="212">1. No electric power to heater.<br />
2. Fan blade contacts inside of heater housing.<br />
3. Fan blade(s) bent<br />
4. Fan motor defective.</td>
<td width="257">1. Check current to an electric outlet. If voltage is correct, check the power cord and extension cord for<br />
2. Be sure that housing is not damaged. Make sure there are no obstructions to the fan.<br />
3. Straighten blade(s) to match others.<br />
4. Replace motor.</td>
</tr>
<tr>
<td width="157">4. Heater will not fire.</td>
<td width="212">1.    No spark at ignitor.<br />
2.    Improper spark gap.<br />
3.    Bad electrode.</td>
<td width="257">1Check ignitor wire. Re-­‐attach or tighten if loose. Check Spark module. Replace if necessary.<br />
2Set gap (See specifications for gap).<br />
3. Replace Spark Plug.</td>
</tr>
<tr>
<td width="157">5. Heater quits while running.</td>
<td width="212">1. Internal temperature too high causing the limit switch to shut down the operation.<br />
2. Damaged Control Valve.<br />
3. Dust or debris build-­‐up inside of the heater.</td>
<td width="257">1. If the output of the heater is restricted, the internal temperature becomes too high. Move the heater away from any obstructions.<br />
2. Replace Control Valve.<br />
3. Clean the inside of the heater.</td>
</tr>
</tbody>
</table>
<p><strong>Always be sure to follow proper maintenance procedures, by cleaning the heater once per month during regular usage, and check spark gap at least once per season.</strong></p>
<p><strong>WIRING DIAGRAMS</strong></p>
<p>PIEZO/MANUAL SPARK MODELS MANUELLE<br />
MODELOS DE CHISPA MANUAL O PIEZOELCTRICA</p>
<p><img fetchpriority="high" decoding="async" class="attachment-post-thumbnail aligncenter ezlazyloaded" src="images/15.webp" sizes="" srcset="" alt="Dyna-Glo FA40DGP-01 Propane Construction Heater -WIRING DIAGRAMS" width="876" height="586" data-ezsrcset="https://manuals.plus/wp-content/uploads/2021/09/Dyna-Glo-FA40DGP-01-Propane-Construction-Heater-WIRING-DIAGRAMS.jpg?ezimgfmt=ng:webp/ngcb1 733w,https://manuals.plus/wp-content/uploads/2021/09/Dyna-Glo-FA40DGP-01-Propane-Construction-Heater-WIRING-DIAGRAMS-300x201.jpg?ezimgfmt=ng:webp/ngcb1 300w" data-ezsrc="https://manuals.plus/wp-content/uploads/2021/09/Dyna-Glo-FA40DGP-01-Propane-Construction-Heater-WIRING-DIAGRAMS.jpg?ezimgfmt=rs:612x409/rscb1/ng:webp/ngcb1" /></p>
<p><strong>WIRING DIAGRAMS</strong></p>
<p><img decoding="async" class="attachment-post-thumbnail aligncenter ezlazyloaded" src="images/16.webp" sizes="" srcset="" alt="Dyna-Glo FA40DGP-01 Propane Construction Heater -WIRING DIAGRAMS 1" width="963" height="915" data-ezsrcset="https://manuals.plus/wp-content/uploads/2021/09/Dyna-Glo-FA40DGP-01-Propane-Construction-Heater-WIRING-DIAGRAMS-1.jpg?ezimgfmt=ng:webp/ngcb1 535w,https://manuals.plus/wp-content/uploads/2021/09/Dyna-Glo-FA40DGP-01-Propane-Construction-Heater-WIRING-DIAGRAMS-1-300x285.jpg?ezimgfmt=ng:webp/ngcb1 300w" data-ezsrc="https://manuals.plus/wp-content/uploads/2021/09/Dyna-Glo-FA40DGP-01-Propane-Construction-Heater-WIRING-DIAGRAMS-1.jpg?ezimgfmt=rs:612x582/rscb1/ng:webp/ngcb1" /></p>
<h4>REPLACEMENT PARTS LIST</h4>
<p>MODELS:<br />
FA40 Series<br />
FA50 Series<br />
FA60 Series</p>
<p><img decoding="async" class="attachment-post-thumbnail aligncenter ezlazyloaded" src="images/17.webp" sizes="" srcset="" alt="Dyna-Glo FA40DGP-01 Propane Construction Heater - REPLACEMENT PARTS LIST" width="949" height="864" data-ezsrcset="https://manuals.plus/wp-content/uploads/2021/09/Dyna-Glo-FA40DGP-01-Propane-Construction-Heater-REPLACEMENT-PARTS-LIST.jpg?ezimgfmt=ng:webp/ngcb1 553w,https://manuals.plus/wp-content/uploads/2021/09/Dyna-Glo-FA40DGP-01-Propane-Construction-Heater-REPLACEMENT-PARTS-LIST-300x273.jpg?ezimgfmt=ng:webp/ngcb1 300w" data-ezsrc="https://manuals.plus/wp-content/uploads/2021/09/Dyna-Glo-FA40DGP-01-Propane-Construction-Heater-REPLACEMENT-PARTS-LIST.jpg?ezimgfmt=rs:612x557/rscb1/ng:webp/ngcb1" /></p>
<p><strong>REPLACEMENT PARTS LIST</strong></p>
<table width="1214">
<tbody>
<tr>
<td rowspan="2" width="61"><strong><em> </em></strong><strong>ITEM No.</strong></td>
<td rowspan="2" width="279"><strong>DESCRIPTION</strong></td>
<td rowspan="2" width="52"><strong><em> </em></strong><strong>QTY</strong></td>
<td colspan="3" width="298"><strong>PART NUMBER</strong></td>
</tr>
<tr>
<td width="100"><strong>40 SERIES</strong></td>
<td width="99"><strong>50 SERIES</strong></td>
<td width="100"><strong>60 SERIES</strong></td>
</tr>
<tr>
<td width="61">1</td>
<td width="279">INNER SHELL ASSEMBLY</td>
<td width="52">1</td>
<td width="100">2304818</td>
<td width="99">2304818</td>
<td width="100">2304818</td>
</tr>
<tr>
<td width="61">2</td>
<td width="279">NOZZLE</td>
<td width="52">1</td>
<td width="100">*2304829</td>
<td width="99">*2304942</td>
<td width="100">*2325121</td>
</tr>
<tr>
<td width="61">3</td>
<td width="279">FLAME CAP</td>
<td width="52">1</td>
<td width="100">2304819</td>
<td width="99">2304819</td>
<td width="100">2325120</td>
</tr>
<tr>
<td width="61">4</td>
<td width="279">THERMAL SWITCH BRACKET</td>
<td width="52">1</td>
<td width="100">2304826</td>
<td width="99">2304826</td>
<td width="100">2304826</td>
</tr>
<tr>
<td width="61">5</td>
<td width="279">THERMAL SWITCH</td>
<td width="52">1</td>
<td width="100">2201373</td>
<td width="99">2201563</td>
<td width="100">2201599</td>
</tr>
<tr>
<td width="61">6</td>
<td width="279">NOZZLE NUT</td>
<td width="52">1</td>
<td width="100">2304578</td>
<td width="99">2304578</td>
<td width="100">2304578</td>
</tr>
<tr>
<td width="61">7</td>
<td width="279">SPARK PLUG ASSEMBLY</td>
<td width="52">1</td>
<td width="100">2201375</td>
<td width="99">2201375</td>
<td width="100">2206033</td>
</tr>
<tr>
<td width="61">8</td>
<td width="279">THERMOCOUPLE ASSEMBLY (1130/1474-­‐425L)</td>
<td width="52">1</td>
<td width="100">2304885</td>
<td width="99">2304885</td>
<td width="100">2304885</td>
</tr>
<tr>
<td width="61">9</td>
<td width="279">GAS TUBING ASSEMBLY</td>
<td width="52">1</td>
<td width="100">2304830</td>
<td width="99">2304830</td>
<td width="100">2304830</td>
</tr>
<tr>
<td rowspan="4" width="61"><strong><em> </em></strong>10</td>
<td width="279">OUTER SHELL -­‐ ORANGE</td>
<td width="52">1</td>
<td width="100">2305403</td>
<td width="99">2305403</td>
<td width="100">2305403</td>
</tr>
<tr>
<td width="279">OUTER SHELL -­‐ BLACK</td>
<td width="52">1</td>
<td width="100">2315915</td>
<td width="99">2315915</td>
<td width="100">2315915</td>
</tr>
<tr>
<td width="279">OUTER SHELL -­‐ GRAY</td>
<td width="52">1</td>
<td width="100">2315956</td>
<td width="99">2315956</td>
<td width="100">2315956</td>
</tr>
<tr>
<td width="279">OUTER SHELL -­‐ BLUE</td>
<td width="52">1</td>
<td width="100">2315312</td>
<td width="99">2315312</td>
<td width="100">2315312</td>
</tr>
<tr>
<td width="61">11</td>
<td width="279">CORD WRAP (select models only)</td>
<td width="52">2</td>
<td width="100">N/A</td>
<td width="99">N/A</td>
<td width="100">N/A</td>
</tr>
<tr>
<td rowspan="2" width="61">12</td>
<td width="279">HANDLE ASSEMBLY -­‐ BLACK</td>
<td width="52">1</td>
<td width="100">2101447</td>
<td width="99">2101447</td>
<td width="100">2101447</td>
</tr>
<tr>
<td width="279">HANDLE ASSEMBLY -­‐ GRAY</td>
<td width="52">1</td>
<td width="100">2305426</td>
<td width="99">2305426</td>
<td width="100">2305426</td>
</tr>
<tr>
<td width="61">12.1</td>
<td width="279">SCREW -­‐ HANDLE FRONT</td>
<td width="52">1</td>
<td width="100">2001355</td>
<td width="99">2001355</td>
<td width="100">2001355</td>
</tr>
<tr>
<td width="61">12.2</td>
<td width="279">SCREW -­‐ HANDLE FRONT</td>
<td width="52">1</td>
<td width="100">2001077</td>
<td width="99">2001077</td>
<td width="100">2001077</td>
</tr>
<tr>
<td width="61">12.3</td>
<td width="279">NUT -­‐ HANDLE REAR</td>
<td width="52">1</td>
<td width="100">2000384</td>
<td width="99">2000384</td>
<td width="100">2000384</td>
</tr>
<tr>
<td width="61">13</td>
<td width="279">MOTOR SUPPORT</td>
<td width="52">1</td>
<td width="100">2304823</td>
<td width="99">2304823</td>
<td width="100">2304823</td>
</tr>
<tr>
<td width="61">13.1</td>
<td width="279">MOTOR -­‐ MOUNTING BOLT</td>
<td width="52">2</td>
<td width="100">2001332</td>
<td width="99">2001332</td>
<td width="100">2001332</td>
</tr>
<tr>
<td width="61">13.2</td>
<td width="279">SLEEVE</td>
<td width="52">1</td>
<td width="100">2304949</td>
<td width="99">2304949</td>
<td width="100">2304949</td>
</tr>
<tr>
<td width="61">14</td>
<td width="279">MOTOR ASSEMBLY</td>
<td width="52">1</td>
<td width="100">2305909</td>
<td width="99">2305447</td>
<td width="100">2304547</td>
</tr>
<tr>
<td width="61">14.1</td>
<td width="279">MOTOR -­‐ FAN</td>
<td width="52">1</td>
<td width="100">2304821</td>
<td width="99">2304821</td>
<td width="100">2304821</td>
</tr>
<tr>
<td rowspan="2" width="61">15</td>
<td width="279">FAN GUARD -­‐ BLACK</td>
<td width="52">1</td>
<td width="100">2304828</td>
<td width="99">2304828</td>
<td width="100">2304828</td>
</tr>
<tr>
<td width="279">FAN GUARD -­‐ GRAY</td>
<td width="52">1</td>
<td width="100">2305411</td>
<td width="99">2305411</td>
<td width="100">2305411</td>
</tr>
<tr>
<td width="61">16</td>
<td width="279">MOTOR BRACKET</td>
<td width="52">1</td>
<td width="100">2304937</td>
<td width="99">2304937</td>
<td width="100">2304937</td>
</tr>
<tr>
<td width="61">17</td>
<td width="279">VALVE -­‐ GAS</td>
<td width="52">1</td>
<td width="100">GS22 (FA40)</td>
<td width="99">GS22A(FA60)</td>
<td width="100">GS22A(FA60)</td>
</tr>
<tr>
<td width="61">18</td>
<td width="279">PRESSURE SWITCH</td>
<td width="52">1</td>
<td width="100">N/A</td>
<td width="99">N/A</td>
<td width="100">N/A</td>
</tr>
<tr>
<td width="61">19</td>
<td width="279">VALVE BRACKET</td>
<td width="52">1</td>
<td width="100">2304624</td>
<td width="99">2304624</td>
<td width="100">2304624</td>
</tr>
<tr>
<td rowspan="2" width="61">20</td>
<td width="279">BASE ASSEMBLY -­‐ BLACK</td>
<td width="52">1</td>
<td width="100">2304923</td>
<td width="99">2304923</td>
<td width="100">2304923</td>
</tr>
<tr>
<td width="279">BASE ASSEMBLY -­‐ GREY</td>
<td width="52">1</td>
<td width="100">2305405</td>
<td width="99">2305405</td>
<td width="100">2305405</td>
</tr>
<tr>
<td width="61">21</td>
<td width="279">POWER CORD ASSEMBLY</td>
<td width="52">1</td>
<td width="100">2201368</td>
<td width="99">2101670</td>
<td width="100">2101670</td>
</tr>
<tr>
<td width="61">22</td>
<td width="279">GAS CONNECTOR INLET</td>
<td width="52">1</td>
<td width="100">2304831</td>
<td width="99">2304831</td>
<td width="100">2304831</td>
</tr>
<tr>
<td width="61">23</td>
<td width="279">CAPACITOR</td>
<td width="52">1</td>
<td width="100">2201372</td>
<td width="99">2201372</td>
<td width="100">2201372</td>
</tr>
<tr>
<td rowspan="2" width="61">24</td>
<td width="279">BASE LOWER -­‐BLACK</td>
<td width="52">1</td>
<td width="100">2304925</td>
<td width="99">2304925</td>
<td width="100">2304925</td>
</tr>
<tr>
<td width="279">BASE LOWER -­‐ GREY</td>
<td width="52">1</td>
<td width="100">2305407</td>
<td width="99">2305407</td>
<td width="100">2305407</td>
</tr>
<tr>
<td rowspan="2" width="61">25</td>
<td width="279">KNOB GAS VALVE -­‐ BLACK</td>
<td width="52">1</td>
<td width="100">2101451</td>
<td width="99">2101451</td>
<td width="100">2101451</td>
</tr>
<tr>
<td width="279">KNOB GAS VALVE -­‐ ORANGE</td>
<td width="52">1</td>
<td width="100">2305466</td>
<td width="99">2305466</td>
<td width="100">2305466</td>
</tr>
<tr>
<td rowspan="2" width="61">26</td>
<td width="279">HEIGHT CONTROLLER -­‐ BLACK</td>
<td width="52">1</td>
<td width="100">2304927</td>
<td width="99">2304927</td>
<td width="100">2304927</td>
</tr>
<tr>
<td width="279">HEIGHT CONTROLLER -­‐ GREY</td>
<td width="52">1</td>
<td width="100">2305409</td>
<td width="99">2305409</td>
<td width="100">2305409</td>
</tr>
<tr>
<td rowspan="2" width="61">27</td>
<td width="279">HEIGHT CONTROL SCREW -­‐ BLACK</td>
<td width="52">1</td>
<td width="100">2304510</td>
<td width="99">2304510</td>
<td width="100">2304510</td>
</tr>
<tr>
<td width="279">HEIGHT CONTROL SCREW -­‐ ORANGE</td>
<td width="52">1</td>
<td width="100">2305467</td>
<td width="99">2305467</td>
<td width="100">2305467</td>
</tr>
<tr>
<td width="61">28</td>
<td width="279">LEAD WIRE ASSEMBLY</td>
<td width="52">1</td>
<td width="100">2201371</td>
<td width="99">2201371</td>
<td width="100">2201371</td>
</tr>
<tr>
<td width="61">29</td>
<td width="279">SPARK MODULE</td>
<td width="52">1</td>
<td width="100">N/A</td>
<td width="99">2201391</td>
<td width="100">2201391</td>
</tr>
<tr>
<td width="61">30</td>
<td width="279">PCB ASSEMBLY</td>
<td width="52">1</td>
<td width="100">2201369</td>
<td width="99">2201369</td>
<td width="100">2201369</td>
</tr>
<tr>
<td rowspan="6" width="61"><strong><em> </em></strong></p>
<p><strong><em> </em></strong></p>
<p>31</td>
<td width="279">REG &amp; HOSE ASSEMBLY -­‐ 10FT (3M)</td>
<td width="52">1</td>
<td width="100">KR-­‐106-­‐01(POL-­‐3000)</td>
<td width="99">KR-­‐106-­‐01(POL-­‐3000)</td>
<td width="100">KR-­‐106-­‐01(POL-­‐3000)</td>
</tr>
<tr>
<td width="279">REG &amp; HOSE ASSEMBLY -­‐ 10FT (3M) w/HANDWHEEL</td>
<td width="52">1</td>
<td width="100">KR-­‐106-­‐01(HW-­‐3000)</td>
<td width="99">KR-­‐106-­‐01(HW-­‐3000)</td>
<td width="100">KR-­‐106-­‐01(HW-­‐3000)</td>
</tr>
<tr>
<td colspan="6"></td>
</tr>
<tr>
<td width="279">REG &amp; HOSE ASSEMBLY (QCC) -­‐ 10FT (3M)</td>
<td width="52">1</td>
<td width="100">TYQ-­‐9C-­‐3000</td>
<td width="99">TYQ-­‐10C-­‐3000</td>
<td width="100">TYQ-­‐10C-­‐3000</td>
</tr>
<tr>
<td width="279">REG &amp; HOSE ASSEMBLY -­‐15FT (4.6M)</td>
<td width="52">1</td>
<td width="100">KR-­‐106-­‐01(POL-­‐4600)</td>
<td width="99">KR-­‐106-­‐01(POL-­‐4600)</td>
<td width="100">KR-­‐106-­‐01(POL-­‐4600)</td>
</tr>
<tr>
<td width="279">REG &amp; HOSE ASSEMBLY -­‐15FT (4.6M) w/HAND WHEEL</td>
<td width="52">1</td>
<td width="100">KR-­‐106-­‐01(HW-­‐4600)</td>
<td width="99">KR-­‐106-­‐01(HW-­‐4600)</td>
<td width="100">KR-­‐106-­‐01(HW-­‐4600)</td>
</tr>
<tr>
<td width="279">REG &amp; HOSE ASSEMBLY (QCC) -­‐ 15FT (4.6M)</td>
<td width="52">1</td>
<td width="100">TYQ-­‐9C-­‐4572</td>
<td width="99">TYQ-­‐10C-­‐4572</td>
<td width="100">TYQ-­‐10C-­‐4572</td>
</tr>
</tbody>
</table>
<p>* VERSION NOT SHOWN IN EXPLODED VIEW</p>
<h4>PROPANE CONSTRUCTION HEATER ILLUSTRATED / PARTS BREAKDOWN</h4>
<p><img loading="lazy" decoding="async" class="attachment-post-thumbnail aligncenter ezlazyloaded" src="images/18.webp" sizes="auto, " srcset="" alt="Dyna-Glo FA40DGP-01 Propane Construction Heater -PROPANE CONSTRUCTION HEATER" width="940" height="834" data-ezsrcset="https://manuals.plus/wp-content/uploads/2021/09/Dyna-Glo-FA40DGP-01-Propane-Construction-Heater-PROPANE-CONSTRUCTION-HEATER.jpg?ezimgfmt=ng:webp/ngcb1 561w,https://manuals.plus/wp-content/uploads/2021/09/Dyna-Glo-FA40DGP-01-Propane-Construction-Heater-PROPANE-CONSTRUCTION-HEATER-300x266.jpg?ezimgfmt=ng:webp/ngcb1 300w" data-ezsrc="https://manuals.plus/wp-content/uploads/2021/09/Dyna-Glo-FA40DGP-01-Propane-Construction-Heater-PROPANE-CONSTRUCTION-HEATER.jpg?ezimgfmt=rs:612x543/rscb1/ng:webp/ngcb1" /></p>
<p><strong>REPLACEMENT PARTS LIST</strong></p>
<table width="1251">
<tbody>
<tr>
<td rowspan="2" width="57"><strong><em> </em></strong><strong>ITEM</strong></p>
<p><strong>No.</strong></td>
<td rowspan="2" width="262"><strong><em> </em></strong><strong>DESCRIPTION</strong></td>
<td rowspan="2" width="49"><strong><em> </em></strong><strong>QTY</strong></td>
<td colspan="3" width="275"><strong>PART NUMBER</strong></td>
</tr>
<tr>
<td width="92"><strong>100 SERIES</strong></td>
<td width="92"><strong>125 SERIES</strong></td>
<td width="92"><strong>150 SERIES</strong></td>
</tr>
<tr>
<td width="57">1</td>
<td width="262">INNER SHELL ASSEMBLY</td>
<td width="49">1</td>
<td width="92">2304929</td>
<td width="92">2304929</td>
<td width="92">2304929</td>
</tr>
<tr>
<td width="57">2</td>
<td width="262">NOZZLE</td>
<td width="49">1</td>
<td width="92">*2304943</td>
<td width="92">5030077</td>
<td width="92">2304944</td>
</tr>
<tr>
<td width="57">3</td>
<td width="262">FLAME CAP</td>
<td width="49">1</td>
<td width="92">2304930</td>
<td width="92">2325122</td>
<td width="92">2304931</td>
</tr>
<tr>
<td width="57">4</td>
<td width="262">THERMAL SWITCH BRACKET</td>
<td width="49">1</td>
<td width="92">2304826</td>
<td width="92">2315515</td>
<td width="92">2001355</td>
</tr>
<tr>
<td width="57">5</td>
<td width="262">THERMAL SWITCH</td>
<td width="49">1</td>
<td width="92">2201373</td>
<td width="92">2201373</td>
<td width="92">2201373</td>
</tr>
<tr>
<td width="57">6</td>
<td width="262">NOZZLE NUT</td>
<td width="49">1</td>
<td width="92">2304578</td>
<td width="92">2304945</td>
<td width="92">2304945</td>
</tr>
<tr>
<td width="57">7</td>
<td width="262">SPARK PLUG ASSEMBLY</td>
<td width="49">1</td>
<td width="92">2201392</td>
<td width="92">2206034</td>
<td width="92">2201393</td>
</tr>
<tr>
<td width="57">8</td>
<td width="262">THERMOCOUPLE ASSEMBLY (1130/1474-­‐425L)</td>
<td width="49">1</td>
<td width="92">2304885</td>
<td width="92">2304885</td>
<td width="92">2304885</td>
</tr>
<tr>
<td width="57">9</td>
<td width="262">GAS TUBING ASSEMBLY</td>
<td width="49">1</td>
<td width="92">2304946</td>
<td width="92">2325138</td>
<td width="92">2304947</td>
</tr>
<tr>
<td rowspan="4" width="57"><strong><em> </em></strong></p>
<p>10</td>
<td width="262">OUTER SHELL -­‐ ORANGE</td>
<td width="49">1</td>
<td width="92">N/A</td>
<td width="92">2305971</td>
<td width="92">N/A</td>
</tr>
<tr>
<td width="262">OUTER SHELL -­‐ BLACK</td>
<td width="49">1</td>
<td width="92">N/A</td>
<td width="92">N/A</td>
<td width="92">N/A</td>
</tr>
<tr>
<td width="262">OUTER SHELL -­‐ GRAY</td>
<td width="49">1</td>
<td width="92">2315916</td>
<td width="92">2315916</td>
<td width="92">2315916</td>
</tr>
<tr>
<td width="262">OUTER SHELL -­‐ BLUE</td>
<td width="49">1</td>
<td width="92">N/A</td>
<td width="92">N/A</td>
<td width="92">N/A</td>
</tr>
<tr>
<td width="57">11</td>
<td width="262">CORD WRAP (select models only)</td>
<td width="49">2</td>
<td width="92">2101423</td>
<td width="92">2101423</td>
<td width="92">2101423</td>
</tr>
<tr>
<td rowspan="2" width="57">12</td>
<td width="262">HANDLE ASSEMBLY -­‐ BLACK</td>
<td width="49">1</td>
<td width="92">2101447</td>
<td width="92">2101447</td>
<td width="92">2101447</td>
</tr>
<tr>
<td width="262">HANDLE ASSEMBLY -­‐ GRAY</td>
<td width="49">1</td>
<td width="92">2305426</td>
<td width="92">2305426</td>
<td width="92">2305426</td>
</tr>
<tr>
<td width="57">12.1</td>
<td width="262">SCREW -­‐ HANDLE FRONT</td>
<td width="49">1</td>
<td width="92">2001355</td>
<td width="92">2001355</td>
<td width="92">2001355</td>
</tr>
<tr>
<td width="57">12.2</td>
<td width="262">SCREW -­‐ HANDLE FRONT</td>
<td width="49">1</td>
<td width="92">2001077</td>
<td width="92">2001077</td>
<td width="92">2001077</td>
</tr>
<tr>
<td width="57">12.3</td>
<td width="262">NUT -­‐ HANDLE REAR</td>
<td width="49">1</td>
<td width="92">2000384</td>
<td width="92">2000384</td>
<td width="92">2000384</td>
</tr>
<tr>
<td width="57">13</td>
<td width="262">MOTOR SUPPORT</td>
<td width="49">1</td>
<td width="92">2304823</td>
<td width="92">2304823</td>
<td width="92">2304823</td>
</tr>
<tr>
<td width="57">13.1</td>
<td width="262">MOTOR -­‐ MOUNTING BOLT</td>
<td width="49">2</td>
<td width="92">2001332</td>
<td width="92">2001332</td>
<td width="92">2001332</td>
</tr>
<tr>
<td width="57">13.2</td>
<td width="262">SLEEVE</td>
<td width="49">1</td>
<td width="92">2304949</td>
<td width="92">2304949</td>
<td width="92">2304949</td>
</tr>
<tr>
<td width="57">14</td>
<td width="262">MOTOR ASSEMBLY</td>
<td width="49">1</td>
<td width="92">2304548</td>
<td width="92">2304548</td>
<td width="92">2304548</td>
</tr>
<tr>
<td width="57">14.1</td>
<td width="262">MOTOR -­‐ FAN</td>
<td width="49">1</td>
<td width="92">2304936</td>
<td width="92">2304936</td>
<td width="92">2304936</td>
</tr>
<tr>
<td rowspan="2" width="57">15</td>
<td width="262">FAN GUARD -­‐ BLACK</td>
<td width="49">1</td>
<td width="92">2304939</td>
<td width="92">2304939</td>
<td width="92">2304939</td>
</tr>
<tr>
<td width="262">FAN GUARD -­‐ GRAY</td>
<td width="49">1</td>
<td width="92">2305412</td>
<td width="92">2305412</td>
<td width="92">2305412</td>
</tr>
<tr>
<td width="57">16</td>
<td width="262">MOTOR BRACKET</td>
<td width="49">1</td>
<td width="92">2304938</td>
<td width="92">2304938</td>
<td width="92">2304938</td>
</tr>
<tr>
<td width="57">17</td>
<td width="262">VALVE -­‐ GAS</td>
<td width="49">1</td>
<td width="92">GS22A(FA125)</td>
<td width="92">GS22A(FA125)</td>
<td width="92">GS22A(FA150)</td>
</tr>
<tr>
<td width="57">18</td>
<td width="262">PRESSURE SWITCH</td>
<td width="49">1</td>
<td width="92">2305976</td>
<td width="92">2305976</td>
<td width="92">2305976</td>
</tr>
<tr>
<td width="57">19</td>
<td width="262">VALVE BRACKET</td>
<td width="49">1</td>
<td width="92">2304624</td>
<td width="92">2304624</td>
<td width="92">2304624</td>
</tr>
<tr>
<td rowspan="2" width="57">20</td>
<td width="262">BASE ASSEMBLY -­‐ BLACK</td>
<td width="49">1</td>
<td width="92">2304924</td>
<td width="92">2304924</td>
<td width="92">2304924</td>
</tr>
<tr>
<td width="262">BASE ASSEMBLY -­‐ GREY</td>
<td width="49">1</td>
<td width="92">N/A</td>
<td width="92">2403354</td>
<td width="92">N/A</td>
</tr>
<tr>
<td width="57">21</td>
<td width="262">POWER CORD ASSEMBLY</td>
<td width="49">1</td>
<td width="92">2101673</td>
<td width="92">2101673</td>
<td width="92">2101673</td>
</tr>
<tr>
<td width="57">22</td>
<td width="262">GAS CONNECTOR INLET</td>
<td width="49">1</td>
<td width="92">2304831</td>
<td width="92">2304831</td>
<td width="92">2304831</td>
</tr>
<tr>
<td width="57">23</td>
<td width="262">CAPACITOR</td>
<td width="49">1</td>
<td width="92">2301390</td>
<td width="92">2301390</td>
<td width="92">2301390</td>
</tr>
<tr>
<td rowspan="2" width="57">24</td>
<td width="262">BASE LOWER -­‐ BLACK</td>
<td width="49">1</td>
<td width="92">2304926</td>
<td width="92">2304926</td>
<td width="92">2304926</td>
</tr>
<tr>
<td width="262">BASE LOWER -­‐ GREY</td>
<td width="49">1</td>
<td width="92">N/A</td>
<td width="92">2403355</td>
<td width="92">N/A</td>
</tr>
<tr>
<td rowspan="2" width="57">25</td>
<td width="262">KNOB GAS VALVE -­‐ BLACK</td>
<td width="49">1</td>
<td width="92">2101451</td>
<td width="92">2101451</td>
<td width="92">2101451</td>
</tr>
<tr>
<td width="262">KNOB GAS VALVE -­‐ ORANGE</td>
<td width="49">1</td>
<td width="92">N/A</td>
<td width="92">2305466</td>
<td width="92">N/A</td>
</tr>
<tr>
<td rowspan="2" width="57">26</td>
<td width="262">HEIGHT CONTROLLER -­‐ BLACK</td>
<td width="49">1</td>
<td width="92">2304928</td>
<td width="92">2304928</td>
<td width="92">2304928</td>
</tr>
<tr>
<td width="262">HEIGHT CONTROLLER -­‐ GREY</td>
<td width="49">1</td>
<td width="92">N/A</td>
<td width="92">2403356</td>
<td width="92">N/A</td>
</tr>
<tr>
<td rowspan="2" width="57">27</td>
<td width="262">HEIGHT CONTROL SCREW -­‐ BLACK</td>
<td width="49">1</td>
<td width="92">2304510</td>
<td width="92">2304510</td>
<td width="92">2304510</td>
</tr>
<tr>
<td width="262">HEIGHT CONTROL SCREW -­‐ ORANGE</td>
<td width="49">1</td>
<td width="92">N/A</td>
<td width="92">2305467</td>
<td width="92">N/A</td>
</tr>
<tr>
<td width="57">28</td>
<td width="262">LEAD WIRE ASSEMBLY</td>
<td width="49">1</td>
<td width="92">2201371</td>
<td width="92">2201371</td>
<td width="92">2201371</td>
</tr>
<tr>
<td width="57">29</td>
<td width="262">SPARK MODULE</td>
<td width="49">1</td>
<td width="92">2201391</td>
<td width="92">2201391</td>
<td width="92">2201391</td>
</tr>
<tr>
<td width="57">30</td>
<td width="262">PCB ASSEMBLY</td>
<td width="49">1</td>
<td width="92">2201369</td>
<td width="92">2201369</td>
<td width="92">2201369</td>
</tr>
<tr>
<td rowspan="6" width="57"><strong><em> </em></strong></p>
<p><strong><em> </em></strong></p>
<p>31</td>
<td width="262">REG &amp; HOSE ASSEMBLY -­‐ 10FT (3M)</td>
<td width="49">1</td>
<td width="92">GR-­‐109(POL-­‐3000)</td>
<td width="92">GR-­‐109(POL-­‐3000)</td>
<td width="92">GR-­‐109(POL-­‐3000)</td>
</tr>
<tr>
<td width="262">REG &amp; HOSE ASSEMBLY -­‐ 10FT (3M) w/HANDWHEEL</td>
<td width="49">1</td>
<td width="92">GR-­‐109(HW-­‐3000)</td>
<td width="92">GR-­‐109(HW-­‐3000)</td>
<td width="92">GR-­‐109(HW-­‐3000)</td>
</tr>
<tr>
<td colspan="6"></td>
</tr>
<tr>
<td width="262">REG &amp; HOSE ASSEMBLY(QCC) -­‐ 10FT (3M)</td>
<td width="49">1</td>
<td width="92">TYQ-­‐6D1-­‐3000</td>
<td width="92">TYQ-­‐6D1-­‐3000</td>
<td width="92">TYQ-­‐6E1-­‐3000</td>
</tr>
<tr>
<td width="262">REG &amp; HOSE ASSEMBLY -­‐15FT (4.6M)</td>
<td width="49">1</td>
<td width="92">GR-­‐109(POL-­‐4600)</td>
<td width="92">GR-­‐109(POL-­‐4600)</td>
<td width="92">GR-­‐109(POL-­‐4600)</td>
</tr>
<tr>
<td width="262">REG &amp; HOSE ASSEMBLY -­‐15FT (4.6M) w/HAND WHEEL</td>
<td width="49">1</td>
<td width="92">GR-­‐109(HW-­‐4600)</td>
<td width="92">GR-­‐109(HW-­‐4600)</td>
<td width="92">GR-­‐109(HW-­‐4600)</td>
</tr>
<tr>
<td width="262">REG &amp; HOSE ASSEMBLY(QCC) -­‐15FT (4.6M)</td>
<td width="49">1</td>
<td width="92">TYQ-­‐6D1-­‐4572</td>
<td width="92">TYQ-­‐6D1-­‐4572</td>
<td width="92">TYQ-­‐6E1-­‐4572</td>
</tr>
</tbody>
</table>
<p>*  VERSION  NOT  SHOWN  IN  EXPLODED  VIEW</p>
<p><strong>PROPANE CONSTRUCTION HEATER ILLUSTRATED / PARTS BREAKDOWN</strong></p>
<p>MODELS: RMC-FA100/DGP/DGP-01<br />
RMC-FA125/DGP/DGP-01<br />
LPFA125DGD<img loading="lazy" decoding="async" class="attachment-post-thumbnail aligncenter ezlazyloaded" src="images/19.webp" sizes="auto, " srcset="" alt="Dyna-Glo FA40DGP-01 Propane Construction Heater -PROPANE CONSTRUCTION HEATER 2" width="969" height="893" data-ezsrcset="https://manuals.plus/wp-content/uploads/2021/09/Dyna-Glo-FA40DGP-01-Propane-Construction-Heater-PROPANE-CONSTRUCTION-HEATER-2.jpg?ezimgfmt=ng:webp/ngcb1 575w,https://manuals.plus/wp-content/uploads/2021/09/Dyna-Glo-FA40DGP-01-Propane-Construction-Heater-PROPANE-CONSTRUCTION-HEATER-2-300x276.jpg?ezimgfmt=ng:webp/ngcb1 300w" data-ezsrc="https://manuals.plus/wp-content/uploads/2021/09/Dyna-Glo-FA40DGP-01-Propane-Construction-Heater-PROPANE-CONSTRUCTION-HEATER-2.jpg?ezimgfmt=rs:612x563/rscb1/ng:webp/ngcb1" /></p>
<p><strong>REPLACEMENT PARTS LIST</strong></p>
<table width="1206">
<tbody>
<tr>
<td rowspan="2" width="63"><strong><em> </em></strong><strong>ITEM</strong></p>
<p><strong>No.</strong></td>
<td rowspan="2" width="289"><strong>DESCRIPTION</strong></td>
<td rowspan="2" width="54"><strong><em> </em></strong><strong>QTY</strong></td>
<td colspan="3" width="303"><strong>PART NUMBER</strong></td>
</tr>
<tr>
<td width="101"><strong>FA100DGP</strong></td>
<td width="101"><strong>FA125DGP</strong></td>
<td width="101"><strong>LPFA125DGD</strong></td>
</tr>
<tr>
<td width="63">1</td>
<td width="289">INNER SHELL ASSEMBLY</td>
<td width="54">1</td>
<td width="101">2304929</td>
<td width="101">2304929</td>
<td width="101">2304929</td>
</tr>
<tr>
<td width="63">2</td>
<td width="289">NOZZLE</td>
<td width="54">1</td>
<td width="101">*2304943</td>
<td width="101">5030077</td>
<td width="101">5030077</td>
</tr>
<tr>
<td width="63">3</td>
<td width="289">FLAME CAP</td>
<td width="54">1</td>
<td width="101">2304930</td>
<td width="101">2325122</td>
<td width="101">2325122</td>
</tr>
<tr>
<td width="63">4</td>
<td width="289">THERMAL SWITCH BRACKET</td>
<td width="54">1</td>
<td width="101">2304826</td>
<td width="101">2315515</td>
<td width="101">2315515</td>
</tr>
<tr>
<td width="63">5</td>
<td width="289">THERMAL SWITCH</td>
<td width="54">1</td>
<td width="101">2201373</td>
<td width="101">2201373</td>
<td width="101">2201373</td>
</tr>
<tr>
<td width="63">6</td>
<td width="289">NOZZLE NUT</td>
<td width="54">1</td>
<td width="101">2304578</td>
<td width="101">2304945</td>
<td width="101">2304945</td>
</tr>
<tr>
<td width="63">7</td>
<td width="289">SPARK PLUG ASSEMBLY</td>
<td width="54">1</td>
<td width="101">2201392</td>
<td width="101">2206034</td>
<td width="101">2206034</td>
</tr>
<tr>
<td width="63">8</td>
<td width="289">THERMOCOUPLE ASSEMBLY (1130/1474-­‐425L)</td>
<td width="54">1</td>
<td width="101">2304885</td>
<td width="101">2304885</td>
<td width="101">2304885</td>
</tr>
<tr>
<td width="63">9</td>
<td width="289">GAS TUBING ASSEMBLY</td>
<td width="54">1</td>
<td width="101">2305975</td>
<td width="101">2325137</td>
<td width="101">2325137</td>
</tr>
<tr>
<td rowspan="2" width="63">10</td>
<td width="289">OUTER SHELL -­‐ ORANGE</td>
<td width="54">1</td>
<td width="101">2305971</td>
<td width="101">2305971</td>
<td width="101">N/A</td>
</tr>
<tr>
<td width="289">OUTER SHELL -­‐ BLACK</td>
<td width="54">1</td>
<td width="101">N/A</td>
<td width="101">N/A</td>
<td width="101">2403443</td>
</tr>
<tr>
<td width="63">11</td>
<td width="289">CORD WRAP</td>
<td width="54">2</td>
<td width="101">2101423</td>
<td width="101">2101423</td>
<td width="101">2101423</td>
</tr>
<tr>
<td width="63">12</td>
<td width="289">MOTOR SUPPORT</td>
<td width="54">1</td>
<td width="101">2304823</td>
<td width="101">2304823</td>
<td width="101">2304823</td>
</tr>
<tr>
<td width="63">12.1</td>
<td width="289">MOTOR -­‐ MOUNTING BOLT</td>
<td width="54">2</td>
<td width="101">2001332</td>
<td width="101">2001332</td>
<td width="101">2001332</td>
</tr>
<tr>
<td width="63">12.2</td>
<td width="289">SLEEVE</td>
<td width="54">1</td>
<td width="101">2304949</td>
<td width="101">2304949</td>
<td width="101">2304949</td>
</tr>
<tr>
<td width="63">13</td>
<td width="289">MOTOR ASSEMBLY</td>
<td width="54">1</td>
<td width="101">2304548</td>
<td width="101">2304548</td>
<td width="101">2304548</td>
</tr>
<tr>
<td width="63">13.1</td>
<td width="289">MOTOR -­‐ FAN</td>
<td width="54">1</td>
<td width="101">2304936</td>
<td width="101">2304936</td>
<td width="101">2304936</td>
</tr>
<tr>
<td rowspan="2" width="63">14</td>
<td width="289">FAN GUARD -­‐ GRAY</td>
<td width="54">1</td>
<td width="101">2305412</td>
<td width="101">2305412</td>
<td width="101">N/A</td>
</tr>
<tr>
<td width="289">FAN GUARD -­‐ BLACK</td>
<td width="54">1</td>
<td width="101">N/A</td>
<td width="101">N/A</td>
<td width="101">2304939</td>
</tr>
<tr>
<td width="63">15</td>
<td width="289">MOTOR BRACKET</td>
<td width="54">1</td>
<td width="101">2304938</td>
<td width="101">2304938</td>
<td width="101">2304938</td>
</tr>
<tr>
<td width="63">16</td>
<td width="289">BASE RIGHT SIDE</td>
<td width="54">1</td>
<td width="101">2306000</td>
<td width="101">2306000</td>
<td width="101">2306000</td>
</tr>
<tr>
<td width="63">17</td>
<td width="289">LEG HOLDER</td>
<td width="54">2</td>
<td width="101">2315002</td>
<td width="101">2315002</td>
<td width="101">2315002</td>
</tr>
<tr>
<td width="63">18</td>
<td width="289">CAPACITOR</td>
<td width="54">1</td>
<td width="101">2301390</td>
<td width="101">2301390</td>
<td width="101">2301390</td>
</tr>
<tr>
<td width="63">19</td>
<td width="289">PRESSURE SWITCH</td>
<td width="54">1</td>
<td width="101">2305976</td>
<td width="101">2305976</td>
<td width="101">2305976</td>
</tr>
<tr>
<td width="63">20</td>
<td width="289">POWER CORD ASSEMBLY</td>
<td width="54">1</td>
<td width="101">2101673</td>
<td width="101">2101673</td>
<td width="101">2101673</td>
</tr>
<tr>
<td width="63">21</td>
<td width="289">GAS CONNECTOR INLET</td>
<td width="54">1</td>
<td width="101">2304831</td>
<td width="101">2304831</td>
<td width="101">2304831</td>
</tr>
<tr>
<td width="63">22</td>
<td width="289">BASE BOTTOM</td>
<td width="54">1</td>
<td width="101">2315001</td>
<td width="101">2315001</td>
<td width="101">2315001</td>
</tr>
<tr>
<td width="63">23</td>
<td width="289">VALVE BRACKET</td>
<td width="54">1</td>
<td width="101">2305973</td>
<td width="101">2305973</td>
<td width="101">2305973</td>
</tr>
<tr>
<td width="63">24</td>
<td width="289">VALVE -­‐ GAS</td>
<td width="54">1</td>
<td width="101">GS22A(FA125)</td>
<td width="101">GS22A(FA125)</td>
<td width="101">GS22A(FA125)</td>
</tr>
<tr>
<td width="63">25</td>
<td width="289">BASE LEFT SIDE</td>
<td width="54">1</td>
<td width="101">2305999</td>
<td width="101">2305999</td>
<td width="101">2305999</td>
</tr>
<tr>
<td rowspan="2" width="63">26</td>
<td width="289">KNOB GAS VALVE -­‐ ORANGE</td>
<td width="54">1</td>
<td width="101">2101588</td>
<td width="101">2101588</td>
<td width="101">N/A</td>
</tr>
<tr>
<td width="289">KNOB GAS VALVE -­‐ BLACK</td>
<td width="54">1</td>
<td width="101">N/A</td>
<td width="101">N/A</td>
<td width="101">2101451</td>
</tr>
<tr>
<td rowspan="2" width="63">27</td>
<td width="289">HEIGHT CONTROL SCREW -­‐ ORANGE</td>
<td width="54">2</td>
<td width="101">2315003</td>
<td width="101">2315003</td>
<td width="101">N/A</td>
</tr>
<tr>
<td width="289">HEIGHT CONTROL SCREW -­‐ BLACK</td>
<td width="54">2</td>
<td width="101">NA</td>
<td width="101">NA</td>
<td width="101">2403444</td>
</tr>
<tr>
<td rowspan="4" width="63"><strong><em> </em></strong></p>
<p>28</td>
<td width="289">REGULATOR &amp; HOSE ASSEMBLY -­‐ 10FT (3M)</td>
<td width="54">1</td>
<td width="101">GR-109(POL-3000)</td>
<td width="101">GR-109(POL-3000)</td>
<td width="101">GR-109(POL-3000)</td>
</tr>
<tr>
<td width="289">REGULATOR &amp; HOSE ASSEMBLY(QCC) -­‐ 10FT (3M)</td>
<td width="54">1</td>
<td width="101">N/A</td>
<td width="101">N/A</td>
<td width="101">TYQ-­‐6D1-­‐3000</td>
</tr>
<tr>
<td width="289">REGULATOR &amp; HOSE ASSEMBLY -­‐15FT (4.6M)</td>
<td width="54">1</td>
<td width="101">GR-109(POL-4600)</td>
<td width="101">GR-109(POL-4600)</td>
<td width="101">GR-109(POL-4600)</td>
</tr>
<tr>
<td width="289">REGULATOR &amp; HOSE ASSEMBLY(QCC) -­‐15FT (4.6M)</td>
<td width="54">1</td>
<td width="101">N/A</td>
<td width="101">N/A</td>
<td width="101">TYQ-­‐6D1-­‐4572</td>
</tr>
<tr>
<td width="63">29</td>
<td width="289">LEG</td>
<td width="54">1</td>
<td width="101">2305972</td>
<td width="101">2305972</td>
<td width="101">2305972</td>
</tr>
<tr>
<td width="63">30</td>
<td width="289">LEAD WIRE ASSEMBLY</td>
<td width="54">1</td>
<td width="101">2201371</td>
<td width="101">2201371</td>
<td width="101">2201371</td>
</tr>
<tr>
<td width="63">31</td>
<td width="289">SPARK MODULE</td>
<td width="54">1</td>
<td width="101">2201391</td>
<td width="101">2201391</td>
<td width="101">2201391</td>
</tr>
<tr>
<td width="63">32</td>
<td width="289">PCB ASSEMBLY</td>
<td width="54">1</td>
<td width="101">2201369</td>
<td width="101">2201369</td>
<td width="101">2201369</td>
</tr>
</tbody>
</table>
<p>*  VERSION  NOT  SHOWN  IN  EXPLODED  VIEW</p>
<h4>WARRANTY</h4>
<p><strong>LIMITED WARRANTY:</strong><br />
This limited warranty is extended to the original retail purchaser of this Forced Air/Convection/Radiant Heater and warrants against any defect in materials and workmanship for a period of one (1) year from the date of retail sale. GHP Group, Inc., at its option, will either provide replacement parts or replace or repair the unit, when properly returned to the retailer where purchased or one of our service centers as directed by GHP Group,  Inc., within one (1) year of retail purchase. (Shipping costs, labor costs, etc. are the responsibility of the purchaser.)</p>
<p><strong>DUTIES OF THE OWNER:</strong><br />
This heating appliance must be operated in accordance with the written instructions furnished with this heater. This warranty shall not excuse the owner from properly maintaining this heater in accordance with the written instructions furnished with this heater. A bill of sale, canceled check or payment record must be kept to verify the purchase date and establish a warranty period. Original carton should be kept in case of warranty return of the unit.</p>
<p><strong>WHAT IS NOT COVERED:</strong></p>
<ol>
<li>Damage resulting from use of improper fuel.</li>
<li>Damage caused by misuse or use contrary to the owners manual and safety guidelines.</li>
<li>Damage caused by a lack of normal maintenance.</li>
<li>Fuses</li>
<li>Use of non-standard parts or accessories.</li>
<li>Damage caused in transit. Freight charges on warranty parts or heaters to and from the factory shall be the responsibility of the owner.</li>
</ol>
<p>This warranty does not imply or assume any responsibility for consequential damages that may result from t he uses, misuse, or lack of routine maintenance of this heating appliance. A cleaning fee and the cost of parts may be charged for appliance failures resulting from lack of maintenance. This warranty does not cover claims which do not involve defective workmanship or materials. <strong>FAILURE TO PERFORM GENERAL MAINTENANCE (INCLUDING CLEANING) WILL VOID THIS WARRANTY.</strong></p>
<p>THIS LIMITED WARRANTY IS GIVEN TO THE PURCHASER IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY OF FITNESS FOR A PARTICULAR PURPOSE. THE REMEDY PROVIDED IN THIS WARRANTY IS EXCLUSIVE AND IS GRANTED IN LIEU OF ALL OTHER REMEDIES. IN NO  EVENT WILL GHP GROUP, INC. BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES.</p>
<p>Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you.</p>
<p><strong>CLAIMS HANDLED AS FOLLOWS:</strong></p>
<ol>
<li>Contact your retailer and explain the problem.</li>
<li>If the retailer is unable to resolve the problem, contact our Customer Service Dept. detailing the heater model, the problem, and proof of date of purchase.</li>
<li>A representative will contact you. DO NOT RETURN THE HEATER TO GHP GROUP,INC. unless instructed by our Representative. This warranty gives you specific legal rights and you may also have other rights which vary from state to state.</li>
</ol>
<p>TO REGISTER THE WARRANTY ON YOUR HEATER, PLEASE FILL OUT THIS CARD COMPLETELY AND MAIL WITHIN 14 DAYS FROM DATE OF PURCHASE OR REGISTER ON-LINE AT <a href="http://www.ghpgroupinc.com/" target="_blank" rel="noopener">www.ghpgroupinc.com</a></p>
<p>NAME: ______________________________________ PHONE: (          ) __________________ EMAIL: ____________________________<br />
ADDRESS: _________________________________ CITY: ______________________________ STATE: __________ ZIP: ____________<br />
MODEL: ____________________ SERIAL #: _______________________________________ DATE PURCHASED: __________________<br />
DEALER PURCHASED FROM: ____________________________________________ TYPE OF STORE: __________________________<br />
CITY &amp; STATE WHERE PURCHASED: ______________________________________________ PRICE PAID: _______________________</p>
<p>Please Take a Minute To Give Us Your Answers To The Following Questions.<br />
All Responses Are Used Solely For Market Research And Are Held In Strict Confidence.</p>
<p>Who primarily decided this purchase? □ Male   □ Female □  18-24   □ 25-39   □ 40-59   □ 60 and over<br />
Purpose of Purchase? _______________________________________________________________________________________________</p>
<p>Do you own any other portable heaters? □ Yes  □ No If yes, type____________________________brand_____________________<br />
How do you intend to use your new heater? □ Construction Site  □ Farm  □Warehouse/Commercial  □ Garage/Outbuilding  □ Other<br />
How did you  become aware of this heater? □ In-Store Display  □ Newspaper Ad  □ Magazine Ad □ Friend/Relative<br />
□  TV Commercial □ Store Salesperson  □ Other  ___________________________ What made you select this heater? □ Style □ Size/Portability<br />
□ Price  □ Package  □ Brand  □ Other ___________________   Do you: □ own □ rent Would you recommend this heater to a friend? □  Yes □ No Please give us your  comments:________________________________________________________________________________________</p>
<p>THANK YOU FOR COMPLETING THIS FORM!<br />
Information will be held confidential.</p>
<p><strong>WARRANTY REGISTRATION</strong><br />
<strong>IMPORTANT</strong>: We urge you to fill out your warranty registration card within fourteen (14) days of date of purchase. You can also register your warranty on the internet at <a href="http://www.ghpgroupinc.com/" target="_blank" rel="noopener">www.ghpgroupinc.com</a>. Complete the entire serial number. Retain this portion of the card for your records.</p>
<p><img loading="lazy" decoding="async" class="attachment-post-thumbnail size-post-thumbnail aligncenter ezlazyloaded" src="images/20.webp" alt="Dyna-Glo FA40DGP-01 Propane Construction Heater - 1" width="204" height="262" data-ezsrc="https://manuals.plus/wp-content/uploads/2021/09/Dyna-Glo-FA40DGP-01-Propane-Construction-Heater-1.jpg?ezimgfmt=rs:204x262/rscb1/ng:webp/ngcb1" /></p>
<p>GHP Group, Inc. 6440 W Howard St<br />
Niles, IL 60714-3302 Tel: (877) 447-4768<br />
<a href="http://www.ghpgroupinc.com/" target="_blank" rel="noopener">www.ghpgroupinc.com</a></p>
<p><strong>SAVE THIS CARD!</strong></p>
<p>Place Postage Stamp Here</p>
<p><strong>GHP Group, Inc. 6440 W Howard St Niles, IL 60714-3302</strong></p>
<form id="commentform" class="comment-form" action="https://manuals.plus/wp-comments-post.php" method="post" novalidate="">
<p class="form-submit">
</form>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>

<!--
Performance optimized by W3 Total Cache. Learn more: https://www.boldgrid.com/w3-total-cache/

Page Caching using Disk: Enhanced 

Served from: usemanuals.com @ 2026-04-22 05:46:10 by W3 Total Cache
-->