<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>DIKANG &#8211; UseManuals</title>
	<atom:link href="http://usemanuals.com/dikang/feed/" rel="self" type="application/rss+xml" />
	<link>https://usemanuals.com</link>
	<description>Owner&#039;s manuals for all sorts of products</description>
	<lastBuildDate>Tue, 04 Apr 2023 17:11:54 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.7.2</generator>

<image>
	<url>https://usemanuals.com/wp-content/uploads/2025/02/favicon-32x32-2.png</url>
	<title>DIKANG &#8211; UseManuals</title>
	<link>https://usemanuals.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>DIKANG HG03 Medical Infrared Thermometer Manual</title>
		<link>https://usemanuals.com/dikang/hg03-medical-thermometer/</link>
		
		<dc:creator><![CDATA[ItsManual]]></dc:creator>
		<pubDate>Tue, 04 Apr 2023 17:11:54 +0000</pubDate>
				<category><![CDATA[DIKANG]]></category>
		<guid isPermaLink="false">https://usemanuals.com/?p=59572</guid>

					<description><![CDATA[&#160; DIKANG HG03 Medical Infrared Thermometer User Manual Scope of application This product can measure the body temperature by collecting the infrared heat radiation from the human forehead. The user can measure the body temperature by pointing the probe head at the forehead and pressing the measurement, button. Contraindications: none. Product features Adopt infrared sensor, the performance is stable and reliable; Environmental temperature adaptability, in the changing environment can still be used normally; Probe head structure to ensure more accurate measurement : Automatically saves the last measurement Large size LCD screen, high brightness backlight, display clear and soft; Two temperature units of °C and °F are optional, but the °F is not allowed for clinical use; Automatic shutdown. Battery Installation Use 2 AAA batteries, pay attention to the positive and negative of the battery when installing Screen display Model Temperature value Cell symbol Number of sets of memory Memory value Temperature unit Cue note Switch machine Press the ‘measure button to start the machine, and the word ‘LO’ will be displayed to indicate that the machine is in the condition to be tested. The standby time will be 15 seconds, and the machine will automatically shut down after 15 seconds. Measurement model With dual mode, you can choose to measure the temperature of the body and the temperature of the object, Note: please select ‘body temperature’ mode when measuring human body, Thermometry Position the thermometer probe vertically in the middle of your forehead, about 3 to 5 centimeter s away (see figure 1). Press the “measure’ button, about 1 second later “di”, display the measured value (figure 2), the measurement is completed. If the measured value exceeds the high temperature limit (the default value is 38°C), a five-tone prompt of ‘di-di-di-di” will be issued. Figure: 1 Figure: 2 Setting adjustment Temperature unit setting—Fl Press and hold the “set’ button for 2 seconds to display Fl on the screen. Press the ‘ + ” and “– keys to select Celsius or Fahrenheit units respectively. High temperature limit setting—F2 Press ‘set’ button for 2 seconds, the screen shows Fl, press “set” button once to enter F2, then press “+” button to increase the temperature value by 0.1°C (0.1°F), and press “-” button to decrease the temperature value by 0.1°C (0.1°F). The default high temperature limit is 38°C (100.4°F), and the range can be set from 37.2°C to 38.6°C. The calibration set—F3 Default factory Settings, not allowed by the user. Prompt tone switch setting—F4 Press “set” button for 2 seconds, the screen will display Fl, press “set” button for 3 times to enter F4, and press “+” button to turn on buzzer sound (the symbol appears Of; on the screen) or off buzzer sound (the symbol appears OFF on the screen), Matters needing attention Please stay away from the following situations: Extreme temperature Impact and drop Pollution and dust Direct sunlight Hot and cold environment If not used for a long time, please take out the battery and place it Warning: this device is not a complete replacement for a doctor. It sis not waterproof and should not be immersed in liquid. Specifications Model: HG03 Measuring distance: 3 cm -5cm Power supply: d.c.3.0V Display range: 32.0°C-42.4°C Error range: 32.0°C-35.0°C ±0.3°C 35.1°C-42.0°C ±0.2°C 42 1°C-42.4°C ±0.3°C Hunan Honggao Electronic Technology Co.,Ltd. Address: Building 5, Comprehensive Industrial Park, Tenghui Pioneer Park, Nanxian Economic Development Zone, Yiyang City, Hunan Province Permit Number: Hunan Food and Drug Administration Machinery Production Xu No. 20200041 Registration certificate number: Xiang mechanical injection accuracy 20202070605 Model: HG03 [...]<p><a class="btn btn-secondary understrap-read-more-link" href="https://usemanuals.com/dikang/hg03-medical-thermometer/">Read More...</a></p>]]></description>
										<content:encoded><![CDATA[<p>&nbsp;</p>
<p><strong>DIKANG HG03 Medical Infrared Thermometer User Manual<br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/03/0-57-160x300-1.webp" /></strong></p>
<h4>Scope of application</h4>
<p>This product can measure the body temperature by collecting the infrared heat radiation from the human forehead. The user can measure the body temperature by pointing the probe head at the forehead and pressing the measurement, button. Contraindications: none.</p>
<h4>Product features</h4>
<ul>
<li>Adopt infrared sensor, the performance is stable and reliable;</li>
<li>Environmental temperature adaptability, in the changing environment can still be used normally;</li>
<li>Probe head structure to ensure more accurate measurement :</li>
<li>Automatically saves the last measurement</li>
<li>Large size LCD screen, high brightness backlight, display clear and soft;</li>
<li>Two temperature units of °C and °F are optional, but the °F is not allowed for clinical use;</li>
<li>Automatic shutdown.</li>
</ul>
<h4>Battery Installation</h4>
<p>Use 2 AAA batteries, pay attention to the positive and negative of the battery when installing</p>
<h4>Screen display</h4>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/03/01-148-300x208-1.webp" /></p>
<ol>
<li>Model</li>
<li>Temperature value</li>
<li>Cell symbol</li>
<li>Number of sets of memory</li>
<li>Memory value</li>
<li>Temperature unit</li>
<li>Cue note</li>
</ol>
<h4>Switch machine</h4>
<p>Press the ‘measure button to start the machine, and the word ‘LO’ will be displayed to indicate that the machine is in the condition to be tested. The standby time will be 15 seconds, and the machine will automatically shut down after 15 seconds.</p>
<h4>Measurement model</h4>
<p>With dual mode, you can choose to measure the temperature of the body and the temperature of the object, Note: please select ‘body temperature’ mode when measuring human body,</p>
<h4>Thermometry</h4>
<p>Position the thermometer probe vertically in the middle of your forehead, about 3 to 5 centimeter s away (see figure 1). Press the “measure’ button, about 1 second later “di”, display the measured value (figure 2), the measurement is completed. If the measured value exceeds the high temperature limit (the default value is 38°C), a five-tone prompt of ‘di-di-di-di” will be issued.</p>
<p><em><strong><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/03/02-142-300x156-1.webp" />Figure: 1</strong></em></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/03/03-125.jpg" /><em><strong>Figure: 2</strong></em></p>
<h4>Setting adjustment</h4>
<p><strong>Temperature unit setting—Fl</strong><br />
Press and hold the “set’ button for 2 seconds to display Fl on the screen. Press the ‘ + ” and “– keys to select Celsius or Fahrenheit units respectively.<br />
<strong>High temperature limit setting—F2</strong><br />
Press ‘set’ button for 2 seconds, the screen shows Fl, press “set” button once to enter F2, then press “+” button to increase the temperature value by 0.1°C (0.1°F), and press “-” button to decrease the temperature value by 0.1°C (0.1°F). The default high temperature limit is 38°C (100.4°F), and the range can be set from 37.2°C to 38.6°C.<br />
<strong>The calibration set—F3</strong><br />
Default factory Settings, not allowed by the user.<br />
<strong>Prompt tone switch setting—F4<br />
</strong>Press “set” button for 2 seconds, the screen will display Fl, press “set” button for 3 times to enter F4, and press “+” button to turn on buzzer sound (the symbol appears Of; on the screen) or off buzzer sound (the symbol appears OFF on the screen),</p>
<h4>Matters needing attention</h4>
<p><strong>Please stay away from the following situations:</strong></p>
<ol>
<li>Extreme temperature</li>
<li>Impact and drop</li>
<li>Pollution and dust</li>
<li>Direct sunlight</li>
<li>Hot and cold environment</li>
<li>If not used for a long time, please take out the battery and place it</li>
</ol>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/03/04-122-300x175-1.webp" /></p>
<p><strong>Warning:</strong> this device is not a complete replacement for a doctor. It sis not waterproof and should not be immersed in liquid.</p>
<h4>Specifications</h4>
<ul>
<li><strong>Model:</strong> HG03</li>
<li><strong>Measuring</strong> <strong>distance:</strong> 3 cm -5cm</li>
<li><strong>Power supply: </strong>d.c.3.0V</li>
<li><strong>Display range:</strong> 32.0°C-42.4°C</li>
<li><strong>Error range:</strong>
<ul>
<li>32.0°C-35.0°C ±0.3°C</li>
<li>35.1°C-42.0°C ±0.2°C</li>
<li>42 1°C-42.4°C ±0.3°C</li>
</ul>
</li>
</ul>
<p><strong>Hunan Honggao Electronic Technology Co.,Ltd.</strong></p>
<p><strong>Address:</strong> Building 5, Comprehensive Industrial Park, Tenghui Pioneer Park, Nanxian Economic Development Zone, Yiyang City, Hunan Province</p>
<p><strong>Permit Number:</strong> Hunan Food and Drug Administration Machinery Production Xu No. 20200041</p>
<p><strong>Registration certificate number:</strong> Xiang mechanical injection accuracy 20202070605</p>
<p><strong>Model:</strong> HG03</p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/03/05-114-300x96-1.jpg" /></p>
<form id="commentform" class="comment-form" action="https://manuals.plus/wp-comments-post.php" method="post" novalidate="">
<p class="form-submit"><input id="comment_post_ID" name="comment_post_ID" type="hidden" value="838896" /><br />
<input id="comment_parent" name="comment_parent" type="hidden" value="0" /></p>
</form>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>

<!--
Performance optimized by W3 Total Cache. Learn more: https://www.boldgrid.com/w3-total-cache/

Page Caching using Disk: Enhanced 

Served from: usemanuals.com @ 2026-08-27 12:52:49 by W3 Total Cache
-->