<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>condair &#8211; UseManuals</title>
	<atom:link href="http://usemanuals.com/condair/feed/" rel="self" type="application/rss+xml" />
	<link>https://usemanuals.com</link>
	<description>Owner&#039;s manuals for all sorts of products</description>
	<lastBuildDate>Wed, 28 Jun 2023 09:42:37 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.7.2</generator>

<image>
	<url>https://usemanuals.com/wp-content/uploads/2025/02/favicon-32x32-2.png</url>
	<title>condair &#8211; UseManuals</title>
	<link>https://usemanuals.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>condair CDC-NA 2-10V Duct Humidity Sensor Manual</title>
		<link>https://usemanuals.com/condair/cdc-na-sensor/</link>
		
		<dc:creator><![CDATA[ItsManual]]></dc:creator>
		<pubDate>Wed, 28 Jun 2023 09:42:37 +0000</pubDate>
				<category><![CDATA[condair]]></category>
		<guid isPermaLink="false">https://usemanuals.com/?p=133017</guid>

					<description><![CDATA[CDC-NA 2-10V Duct Humidity Sensor Product Information: CDC-NA – 2-10V Duct Humidity Sensor The CDC-NA – 2-10V Duct Humidity Sensor is a Condair duct humidity sensor that can be configured for either humidity control or as a high limit safety device. The kit includes Component No. 2597926 and Description No. 1509857, which is the 2-10V Duct Humidity Sensor. Product Usage Instructions: Refer to installation overview in section 2 of the user manual. At the place of location, drill a hole with a diameter of 16 mm (5/8) as well as 4 holes for the self-tapping screws into the duct. Loosen the screw on the housing cover and open cover. Lead connecting cable through the cable gland and connect wires to the terminate according to the wiring diagram. Stick gasket on the sensor side centrally on the housing (self-adhesive). Insert the probe into the hole in the duct, then fix the housing to the duct using the 4 self-tapping screws provided. Close the cover and fix it with the screw (do not tighten the screw too much). Note: We recommend using 18-gauge wire, and maximum. View Fullscreen CDC-NA – 2-10V Duct Humidity Sensor 2-10V Duct Humidity Sensor Installation Instructions This document covers the operation and installation instructions for the following Condair duct humidity sensor: Kit No. Component No. Description 2597926 1509857 2-10V Duct Humidity Sensor The humidistat can be configured for either humidity control or as a high limit safety device. 1 ­ Mounting and Installation Location: The Condair CDC-NA is installed directly on the duct. ­ Mounting in the extract air duct (recommended): Mount the CDC-NA in the extract air duct close to the air outlet of the room but downstream from an extract air fan if one is present. ­ Mounting in the supply air duct: Mount the CDC-NA in the supply air duct at least 3 meters downstream from the nearest fan and coil and with a minimum distance of 5x the humidification distance to the steam distribution. Installation: Refer to installation overview in section 2. 1. At the place of location drill a hole with a diameter of 16 mm (5/8″) as well as 4 holes for the self-tapping screws into the duct. 2. Loosen the screw on the housing cover and open cover. 3. Lead connecting cable through the cable gland and connect wires to the terminate according to the wiring diagram. 4. Stick gasket on the sensor side centrally on the housing (self-adhesive). 5. Insert the probe into the hole in the duct, then fix the housing to the duct using the 4 self-tapping screws provided. 6. Close the cover and fix it with the screw (do not tighten the screw too much). Note: We recommend using 18-gauge wire, and maximum &#60;100 ft distance from the unit. 2605769-A EN 2304 Page 1 3 ­ Installation overview A mm (inch) 14×157 ( 0.55×6.2) 47 (1.9) B 91 (3.6) CDC-NA 2597926/1509857 68 (2.7) C 4 3 54 (2.1) 75 (2.9) 16 (0.6) D JP3 3 U… 0…10 V 2 I… 0…20 mA 1 3 U… 2…10 V 2 1 I… 4…20 mA OPC-S JP3 1 23 LED OPA-S i 2 1 © Condair Group AG, Switzerland OPC-S 6 (0.02) OPA-S 1 1: 0V GND 2: 24V AC 24 V 50-60 Hz, 24 VDC ±10% 3: RH 0(2)…10VDC, 0(4)…20mA 2 For Wiring Schematic: Get the Condair Sensor Connect App 70-000251/20201202 Page 2 8 ­ Product Specification Power Supply Sensor Probe (Humidity Sensor) Signal Outputs Environment General Operating Voltage Power Consumption Terminal Connections Measuring element Range Accuracy Hysteresis Repeatability Stability Analog Outputs Analog Signal Resolution Maximum Load Operation Temperature Humidity Housing Materials Filter material 24 V AC 50/60 Hz ± 10 % Max. 2 VA For wires 0.34…2.5 mm2 (AWG 24…12) Capacitive measuring element 0…100 % RH ± 3.0 % at 25 °C ± 1% ± 0.1% &#60; 0.5% / Year 0-10V / 2-10V 10 Bit 20 mA, 500 IEC 721-3-3 -40…70°C (-40…158°F) 95 %rH not condensing PC and ABS PTFE coated 1µm pores Page 3 9 ­ Wiring Diagrams Wiring diagram CDC-NA for RS, EL, GS, US and SE CDC-NA 2-10V Duct Humidity Sensor 1509857 123 0V/GND 24V AC/DC 2-10 VDC EL / RS / GS / US / SE 1 2 3 4 5 6 7 8 9 10 11 12 24VAC Safety Loop GND CH1 CH2 GND Wiring diagram CDC-NA for DL and ME ME / DL Driver board ME / DL X1 24/10 V TMP HUM GND 24V E Enable X16 SC1 SC2 JP5: 10V JP4: 24V 0V/GND 24V AC/DC 2-10 VDC CDC-NA 2-10V Duct Humidity Sensor 1509857 123 Page 4 Wiring diagram CDC-NA with CHD-NA and APS for RS, EL, GS, US and SE APS Air Proofing Switch 2598427 CHD-NA On/Off Duct Humidistat / High Limit 2548732 CDC-NA 2-10V Duct Humidity Sensor 1509857 Com NO NC 0V / GND 24V AC/DC DO1 DO1 DO2 DO2 RT RT 0V/GND 24V AC/DC 2-10 VDC 1 234 567 8 123 EL / RS / GS / US / SE 1 2 3 4 5 6 7 8 9 10 11 12 24VAC Safety Loop GND CH1 CH2 GND Wiring diagram CDC-NA with CHD-NA for DL and ME CDC-NA 2-10V Duct Humidity Sensor 1509857 CHD-NA On/Off Duct Humidistat / High Limit 2548732 0V/GND 24V AC/DC 2-10 VDC 0V / GND 24V AC/DC DO1 DO1 DO2 DO2 RT RT ME / DL Driver board ME / DL X1 24/10 V TMP HUM GND 24V E Enable X16 123 1 234 567 8 SC1 SC2 JP5: 10V JP4: 24V Page 5 [...]<p><a class="btn btn-secondary understrap-read-more-link" href="https://usemanuals.com/condair/cdc-na-sensor/">Read More...</a></p>]]></description>
										<content:encoded><![CDATA[<h4>CDC-NA 2-10V Duct Humidity Sensor</h4>
<h2>Product Information: CDC-NA – 2-10V Duct Humidity Sensor</h2>
<p>The CDC-NA – 2-10V Duct Humidity Sensor is a Condair duct<br />
humidity sensor that can be configured for either humidity control<br />
or as a high limit safety device. The kit includes Component No.<br />
2597926 and Description No. 1509857, which is the 2-10V Duct<br />
Humidity Sensor.</p>
<h2>Product Usage Instructions:</h2>
<ol>
<li>Refer to installation overview in section 2 of the user<br />
manual.</li>
<li>At the place of location, drill a hole with a diameter of 16 mm<br />
(5/8) as well as 4 holes for the self-tapping screws into the<br />
duct.</li>
<li>Loosen the screw on the housing cover and open cover.</li>
<li>Lead connecting cable through the cable gland and connect wires<br />
to the terminate according to the wiring diagram.</li>
<li>Stick gasket on the sensor side centrally on the housing<br />
(self-adhesive).</li>
<li>Insert the probe into the hole in the duct, then fix the<br />
housing to the duct using the 4 self-tapping screws provided.</li>
<li>Close the cover and fix it with the screw (do not tighten the<br />
screw too much).</li>
</ol>
<p>Note: We recommend using 18-gauge wire, and maximum.</p>
<p>View Fullscreen</p>
<p>CDC-NA – 2-10V Duct Humidity Sensor</p>
<p>2-10V Duct Humidity Sensor Installation Instructions</p>
<p>This document covers the operation and installation instructions for the following Condair duct humidity sensor:</p>
<p>Kit No. Component No. Description</p>
<p>2597926 1509857</p>
<p>2-10V Duct Humidity Sensor</p>
<p>The humidistat can be configured for either humidity control or as a high limit safety device.</p>
<p>1 ­ Mounting and Installation<br />
Location: The Condair CDC-NA is installed directly on the duct. ­ Mounting in the extract air duct (recommended):<br />
Mount the CDC-NA in the extract air duct close to the air outlet of the room but downstream from an extract air fan if one is present. ­ Mounting in the supply air duct: Mount the CDC-NA in the supply air duct at least 3 meters downstream from the nearest fan and coil and with a minimum distance of 5x the humidification distance to the steam distribution.<br />
Installation:<br />
Refer to installation overview in section 2. 1. At the place of location drill a hole with a diameter of 16 mm (5/8″) as well as 4 holes for the self-tapping<br />
screws into the duct. 2. Loosen the screw on the housing cover and open cover. 3. Lead connecting cable through the cable gland and connect wires to the terminate according to the wiring<br />
diagram. 4. Stick gasket on the sensor side centrally on the housing (self-adhesive). 5. Insert the probe into the hole in the duct, then fix the housing to the duct using the 4 self-tapping screws provided. 6. Close the cover and fix it with the screw (do not tighten the screw too much). Note: We recommend using 18-gauge wire, and maximum &lt;100 ft distance from the unit.</p>
<p>2605769-A EN 2304</p>
<p>Page 1</p>
<p>3 ­ Installation overview</p>
<p>A mm (inch)<br />
14×157 ( 0.55×6.2)</p>
<p>47 (1.9)</p>
<p>B<br />
91 (3.6)</p>
<p>CDC-NA 2597926/1509857</p>
<p>68 (2.7)</p>
<p>C<br />
4 3</p>
<p>54 (2.1)</p>
<p>75 (2.9) 16 (0.6)</p>
<p>D<br />
JP3 3 U… 0…10 V 2 I… 0…20 mA 1</p>
<p>3 U… 2…10 V</p>
<p>2 1</p>
<p>I… 4…20 mA</p>
<p>OPC-S</p>
<p>JP3</p>
<p>1 23</p>
<p>LED OPA-S</p>
<p>i<br />
2 1 © Condair Group AG, Switzerland</p>
<p>OPC-S</p>
<p>6 (0.02)</p>
<p>OPA-S</p>
<p>1 1: 0V GND 2: 24V AC 24 V 50-60 Hz, 24 VDC ±10% 3: RH 0(2)…10VDC, 0(4)…20mA<br />
2</p>
<p>For Wiring Schematic: Get the Condair<br />
Sensor Connect App<br />
70-000251/20201202<br />
Page 2</p>
<p>8 ­ Product Specification</p>
<p>Power Supply<br />
Sensor Probe (Humidity Sensor)<br />
Signal Outputs Environment General</p>
<p>Operating Voltage Power Consumption Terminal Connections<br />
Measuring element Range Accuracy Hysteresis Repeatability Stability<br />
Analog Outputs Analog Signal Resolution Maximum Load<br />
Operation Temperature Humidity<br />
Housing Materials Filter material</p>
<p>24 V AC 50/60 Hz ± 10 % Max. 2 VA For wires 0.34…2.5 mm2 (AWG 24…12)<br />
Capacitive measuring element 0…100 % RH ± 3.0 % at 25 °C ± 1% ± 0.1% &lt; 0.5% / Year<br />
0-10V / 2-10V 10 Bit 20 mA, 500 IEC 721-3-3 -40…70°C (-40…158°F) 95 %rH not condensing PC and ABS PTFE coated 1µm pores</p>
<p>Page 3</p>
<p>9 ­ Wiring Diagrams<br />
Wiring diagram CDC-NA for RS, EL, GS, US and SE CDC-NA<br />
2-10V Duct Humidity Sensor 1509857<br />
123</p>
<p>0V/GND 24V AC/DC 2-10 VDC</p>
<p>EL / RS / GS / US / SE 1 2 3 4 5 6 7 8 9 10 11 12</p>
<p>24VAC Safety Loop<br />
GND CH1 CH2 GND</p>
<p>Wiring diagram CDC-NA for DL and ME</p>
<p>ME / DL<br />
Driver board ME / DL</p>
<p>X1</p>
<p>24/10 V TMP</p>
<p>HUM</p>
<p>GND</p>
<p>24V E</p>
<p>Enable</p>
<p>X16</p>
<p>SC1 SC2<br />
JP5: 10V JP4: 24V<br />
0V/GND 24V AC/DC 2-10 VDC</p>
<p>CDC-NA<br />
2-10V Duct Humidity Sensor 1509857<br />
123</p>
<p>Page 4</p>
<p>Wiring diagram CDC-NA with CHD-NA and APS for RS, EL, GS, US and SE</p>
<p>APS<br />
Air Proofing Switch 2598427</p>
<p>CHD-NA<br />
On/Off Duct Humidistat / High Limit 2548732</p>
<p>CDC-NA<br />
2-10V Duct Humidity Sensor 1509857</p>
<p>Com NO NC 0V / GND 24V AC/DC DO1 DO1 DO2 DO2 RT RT 0V/GND 24V AC/DC 2-10 VDC</p>
<p>1 234 567 8</p>
<p>123</p>
<p>EL / RS / GS / US / SE 1 2 3 4 5 6 7 8 9 10 11 12</p>
<p>24VAC Safety Loop<br />
GND CH1 CH2 GND</p>
<p>Wiring diagram CDC-NA with CHD-NA for DL and ME<br />
CDC-NA<br />
2-10V Duct Humidity Sensor 1509857</p>
<p>CHD-NA<br />
On/Off Duct Humidistat / High Limit 2548732</p>
<p>0V/GND 24V AC/DC 2-10 VDC 0V / GND 24V AC/DC DO1 DO1 DO2 DO2 RT RT</p>
<p>ME / DL<br />
Driver board ME / DL</p>
<p>X1</p>
<p>24/10 V TMP</p>
<p>HUM</p>
<p>GND</p>
<p>24V E</p>
<p>Enable</p>
<p>X16</p>
<p>123</p>
<p>1 234 567 8</p>
<p>SC1 SC2<br />
JP5: 10V JP4: 24V</p>
<p>Page 5</p>
<h3></h3>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>

<!--
Performance optimized by W3 Total Cache. Learn more: https://www.boldgrid.com/w3-total-cache/

Page Caching using Disk: Enhanced 

Served from: usemanuals.com @ 2026-08-27 12:11:23 by W3 Total Cache
-->