BALDR – UseManuals https://usemanuals.com Owner's manuals for all sorts of products Sun, 09 Jul 2023 08:26:19 +0000 en-US hourly 1 https://wordpress.org/?v=6.7.2 https://usemanuals.com/wp-content/uploads/2025/02/favicon-32x32-2.png BALDR – UseManuals https://usemanuals.com 32 32 BALDR B0340WST2H2R-V7 Weather Station Manual https://usemanuals.com/baldr/b0340wst2h2r-v7-station/ Thu, 27 Apr 2023 05:39:36 +0000 https://usemanuals.com/?p=92358 Read More...

]]>
 

BALDR B0340WST2H2R-V7 Weather Station
User Manual

[email protected]

1.PRODUCT OVERVIEW

1.1 WEATHER STATION (MAIN UNIT)

  1. Outdoor Sensor Channel Indicator From CH1 ,CH2,CH3 to Circular Channels model
  2. Current Outdoor Temperature and Humidity
  3. “CH/▲” Button Switch channel, re-connect to sensor or increase the value
  4. “RCC/SET” Button RCC function or enter into time setting
  5. “MEM/▼” Button Check or clear MAX/MIN records, decrease the value
  6. Button Check or enter into alarm selling
  7. Low Battery Indicator Remind to replace the new batteries
  8. Current Indoor Temperature and Humidity
  9. Temperature Trend Arrow
  10. Weekday abbreviation in 7 Languages
  11. Calendar Display Month/date or date/month optional
  12. Comfort Level Indicator
  13. Humidity Trend Arrow
  14. Weather Forecast Icon Weather forecast for next 12-24 hours
  15. RCC Function Symbol
  16. Backlight/Snooze Button (at top position) Backlight auto off after 20 seconds, 5 minutes snooze time
  17. Current Time 12/24 hours display format optional
  18. AM/PM for 12H Display Format
  19. Max/Min Records of Indoor/Outdoor Temperature and Humidity Auto update at 0:00 each day
  20. Hanging Hole
  21. Battery Compartment Cover
  22. Removable Stand Stored in the battery compartment
1.2 BUTTONS INTRODUCTION

1.3 REMOTE SENSOR

To get accurate readings, please keep the main unit away from any unusual source of heat or cold and make sure that the outdoor sensor is also protected from direct sunlight, rain, or the heat it may experience from being mounted on a warm wall, or be closed near to a warm wall.

2. PACKAGING INCLUDES

Following contents are included in the packaging:
1 x Weather Station Main Unit (not included 3 x AAA batteries)
1 x Remote Sensor (not included 2x AA batteries)
1 x User Manual

3. QUICK SET-UP GUIDE

NOTE: Prepare new and high quality alkaline batteries. Do not mix old and new batteries. Heavy duty or rechargeable batteries are not recommended.

3.1 POWER UP
  1. Remove the main unit’s battery compartment cover, insert 3 new AAA batteries in the back of the display console (please take note of the battery polarity before inserting the batteries).
    Note: The display will beep once and all of the LCD segments will light up 1 for few seconds to verify all segments are operating properly, then display indoor temperature and humidity immediately.
  2. Take out the metal stand inside the battery compartment and screw it into the hole at the main unit’s backside. Install the battery compartment cover.
  3. Remove the sensor’s battery compartment cover, set the channel to CH1, then insert 2 new AA batteries of sensor within 3 MINUTES.

Notes:

  1.  Make sure outside sensor and weather station main unit at the same channel.
  2. Do not touch any buttons in the 3 MINUTES to avoid sensor searching be terminated.
  3. The main unit will automatically receive sensor’s RF signal in 3 MINUTES after ii powered on. During receiving ,signal icon . will flashing, if no signal received within 3 minutes, it will stop receiving, and  you can press and hold the “CH/▲” Button 3 seconds to receive again.
3.2 RCC FUNCTION

After the 3 MINUTES RF signal receiving, the main unit will start searching WWVB radio signal for 7 minutes.

  1. The antenna symbol “▲” will flashing during receiving time, if signal received, the main unit will display the received time/month/date/weekday with symbol ““displaying on screen.
  2. Auto receiving RCC signal at UTC 7:00, 8:00, 9:00, 10:00, and 11 :00 each day. It starts receiving RCC signal at UTC 7:00 everyday, once signal is received at any above time, it will stop receiving signal that day.
  3. Manual receiving: press and hold “RCC/SET” button to enter RCC signal receiving.
  4. During receiving, no response if press other buttons, you can press and hold ”RCC/SET” button to exit RCC receiving.

NOTES:

  1. Make sure the RCC function is ON or you can set it by 3.3 MANUAL SETTINGS —> Detailed Steps —> refers to point 2.
  2. Make sure the time zone is correct (Default time zone is Eastern Standard Time) or you can set the time zone by 3.3 MANUAL SETTINGS —> Detailed Steps —> refers to point 3.
  3. When receiving RCC signal, please keep the weather station close to the window or receive RCC signal outdoors to enhance the signal reception.

*RCC Symbol Display:

  • a. When receiving signal , RCC symbol ” ▲ “will be flashing.
  • b. When signal successfully received, LCD will display the complete RCC symbol “” and exit RCC receiving.
  • c. lf no signal is received, the RCC symbol will disappear.
3.3 MANUAL SETTINGS

NOTE: After RCC signal received, if there is no need for other settings, you can skip the manual settings part. If no RCC signal received or you need to set other settings, please follow the bellow steps to finish setting.

TIPS:

  1. Press and hold ”RCC/SET” button to enter time set mode.
  2. Press “CH/▲” and “MEM/▼” buttons to adjust the value. Hold to adjust quickly.
  3. Press ”RCC/SET” button to confirm and move to the next setting.
  4. Press the top button anytime to exit setting.

Setting Order:

RCC ON/OFF-> Time Zone (if RCC ON)->DST ON/OFF-> 12/24H Time Format->Hour->Minute-> Year ->Month & Date Display->Month->Date-> Weekday abbreviation Language-> Temperature Unit-> Exit.

Detailed Steps:

  1. Press and hold ”RCC/SET” button for 5 seconds to enter setting.
  2. RCC ON/OFF part: Press “CH/ ▲” or “MEM/▼” button to select ON or OFF. (Note: If RCC OFF is selected, it will skip Time Zone setting and move to 12/24 Hour setting.)
  3. Press ”RCC/SET” button to TIME ZONE part. Press “CH/ ▲” or “MEM/▼” button to select: AST, EST, CST, MST, PST, AKST, HST. (Default setting: -5 EST).
  4. Press ”RCC/SET” button to DST ON/OFF part. Default setting: ON. Press “CH/▲” or “MEM/▼” button to select DST ON if you do observe Daylight Saving Time.*DST symbol display:
    a. Select “DST ALWAYS”, means DST function is always ON all the year ‘ round.
    b. Select “DST”, means DST function will be ON during daylight saving time.
    c. Select “DST OFF”, means DST function is OFF.
  5. Press ”RCC/SET” button to 12124H TIME FORMAT part. Default setting :12H format. Press “CH/▲” or “MEM/▼” button to select 12-hour format or 24-hour format.
  6. Press ”RCC/SET” button to HOUR part. Press “CH/▲” or “MEM/▼” button to adjust the value.
  7. Press ”RCC/SET” button to MINUTE part. Press “CH/▲” or “MEM/▼” button to adjust the value.
  8. Press ”RCC/SET” button to YEAR part (year range: 2000-2099). Press “CH/▲” or “MEM/▼” button to adjust the value.
  9. Press ”RCC/SET” button to MONTH & DATE DISPLAY FORMAT part. Press “CH/▲” or “MEM/▼” button to select M/D or D/M format (M: Month ,D: Date).
  10. Press “RCC/SET” button to MONTH part. Press “CH/▲” or “MEM/▼” button to adjust the value.
  11. Press ”RCC/SET” button to DATE part. Press “CH/▲” or “MEM/▼” button to adjust the value.
  12. Press ”RCC/SET” button to WEEKDAY ABBREVIATION LANGUAGE part. Press “CH/▲” or “MEM/▼” button to select the language: ENG(English), DUT(Dutch), DAN (Danish), SPA (Spanish), ITA (Italian), GER(German), FRE (French).
  13. Press ”RCC/SET” button to TEMPERATURE UNIT part. Press “CH/▲” or “MEM/▼” button to select Celsius °C or Fahrenheit °F.
  14. Press “RCC/SET” button to confirm and exit.

NOTE:

  • When RCC OFF is selected, will move directly to 12/24 hour time setting.
  • Weekday will shows automatically after Year, Month and Date are set.
  • During setting, if no operation for 20 seconds, it will automatically save and exit setting.
3.4 REMOTE SENSOR INSTALLATION

3.5 ALARM SETTING
3.5.1 Set Alarm Clock in Order: Hour> Minute> Exit.

3.5.2 Check Alarm Time

3.5.3 Alarm OFF/ON

3.6 SNOOZE MODE
  1. When alarm is ring. press the TOP BUTTON to enter snooze mode, The alarm will ring again in 5 minutes snooze interval. And the” z’” symbol will be flashing on screen to indicate the snooze mode. Press any other button except top button to exit the snooze mode. And the alarm will restart next day.
  2. When alarm rings, the ascending “Bibi” alarm sound will last for 2 minutes if no operation, or you can press any other button except top button to stop the alarm.
3.7 MAX/MIN TEMPERATURE & HUMIDITY RECORDS
  1. Check: Press “MEM /▼” button to switch MAX or MIN readings. The readings will shows for 5 seconds and then will tum back to normal model.
  2. Manually Clear: Press “MEM /▼” button to enter “MAX/MIN” Record Mode. Then press and hold “MEM ▼” button 3-4 seconds to clear all the Max/Min data.
    The screen of indoor and outdoor temperature & humidity will show”–“.
  3. Automatically Clear: The records will be cleared at 00:00 automatically daily.

4. TEMPERATURE & HUMIDITY TREND ARROWS

The temperature and humidity trend arrows indicates the temperature or humidity’s change trend.

5. COMFORT LEVEL INDICATOR

Indoor comfort level indicator keeps you informed the comfort level in your home, and when to dehumidify or humidify.

6. WEATHER FORECAST

  1. The weather icon, where data hourly calculated from indoor/outdoor temperature and humidity forecasts the weather in the next 12 hours.
  2. IT IS NOT THE CURRENT WEATHER. The accuracy will be 70%-75%.
  3. Please note that this forecast can’t compare with professional weather services supported by satellites and high Performance computers.
  4. It merely provides an approximate indication of current developments. Please give priority to the weather forecast of the local weather forecast service.

Note: “Sunny To Cloudy” is default after power-on.

7. BACKLIGHT FUNCTION

When powered on, press the top button to turn on the backlight, and the backlight will last 20 seconds to save power.

8. LOW BATTERY INDICATOR

  1. When Battery Indicator shows next to the Outdoor Temperature, replace batteries in your remote sensor.
  2. When Battery Indicator shows next to the Indoor Temperature, replace batteries in your weather station main unit.

9. SPECIFICATIONS

9.1 TECHNICAL SPECIFICATIONS
  • Indoor Temperature Range: 14 °F- 122 °F(-10°C~ 50.0°C).
  • Outdoor Temperature Range: -40 °F-140 °F(-40°C~60°C).
  • Humidity Range: 1 % to 99% RH.
  • Transmission Range: 328 ft (100 meters), 433MHZ (open air).
  • Power Requirements:

Main Unit: 3 x AAA Alkaline batteries (not included),
Remote Sensor: 2 x AA Alkaline batteries (not included).

9.2 MEASUREMENT SPECIFICATIONS

The following table provides the specifications of the measurement parameters.

10. TROUBLESHOOTING GUIDE

11. PRECAUTIONS

  • Do not mix old and new batteries.
  • Do not mix Alkaline, Standard, Lithium, or Rechargeable batteries with this product.
  • Remove the batteries if storing this product for a long period of time.
  • Ensure the batteries are installed with correct polarity(+ and-).
  • Do not clean any part of the product with benzene, thinner or other solvent chemicals. Use a soft cloth to clean it when necessary.
  • Never immerse the product in water. This can cause electrical shock and damage the product.
  • Do not expose the product to extreme force, shock or temperature or humidity fluctuations.
  • Do not tamper with internal components.

12. WARRANTY

Dear customer,

Thank you for choosing BALDR. We provide 1-year limited warranty on this product from the date of purchase. This product has undergone thorough quality inspection at the factory to ensure that the product is in good condition. We will remedy all defects in workmanship or materials within the warranty period.

In order for the warranty to be granted, all warranty claims must be accompanied by proof of purchase from an authorized distribution partner. Damages due to improper installation or use, unauthorized removal/modify/ repair are not covered by the warranty.

If you have any problems with this product or during use, please do not hesitate to contact us, we will try our best to solve it and offer you satisfactory service including replacement or refund.

For Full Warranty Details, contact us by:

[email protected]


]]>
BALDR B0340WST2H2R-V7 Outdoor Sensor Manual https://usemanuals.com/baldr/b0340wst2h2r-v7-sensor/ Sun, 09 Jul 2023 08:26:19 +0000 https://usemanuals.com/?p=149597 Read More...

]]>
B0340WST2H2R-V7 Outdoor Sensor

Product Information:

The Outdoor Sensor is a device that provides temperature and
humidity readings for outdoor conditions. It consists of a display
console and a remote sensor. The display console requires 3 AAA
batteries, while the remote sensor requires 2 AA batteries. The
device uses wireless communication to transmit data between the
display console and the remote sensor.

Product Usage Instructions:

  1. Power Up:
    1. Remove the battery door on the back of the display
      console.
    2. Insert 3 new AAA batteries into the back of the display
      console, ensuring correct battery polarity.
    3. Take out the metal stand inside the battery compartment and
      screw it into the hole at the back of the main unit.
    4. Replace the battery door.
    5. Remove the battery door of the remote sensor.
    6. Set the channel of the sensor to CH1.
    7. Insert 2 new AA batteries into the back of the sensor within 3
      minutes.
  2. Troubleshooting Guide:If the outdoor sensor signal is lost or showing dashes (- -) on
    the display, follow these steps:

    1. Resync the unit by pressing and holding the CH/ button for 5-6
      seconds. The sensor search icon will flash while searching and
      become solid when the sensor signal is received. Wait for several
      minutes for the sensor to report in or for the search icon to turn
      off.
    2. If synchronization fails, bring the sensor within 10 feet of
      the weather station and try the following:

      1. Ensure that both the display console and sensor are placed at
        least 3ft/0.9m away from electronics that may interfere with
        wireless communication, such as computers, TVs, microwaves, and
        other wireless transmitters or receivers.
      2. Make sure the sensor is not transmitting through solid metal or
        thick walls, as radio frequency sensors cannot transmit through
        these barriers.
  3. Outdoor Temperature and Humidity:The weather station cycles through the values of 3 channels
    every 10 seconds. To exit the cycle mode, press the CH/ button.
  4. Inaccurate Readings:If the temperature reads too high in the daytime or if indoor
    and outdoor temperature/humidity do not agree, follow these
    steps:

    1. Ensure that both the display console and sensor are placed out
      of direct sunlight and away from any heat sources or vents.
    2. Allow up to two hours for the sensor to stabilize due to signal
      and filtering. The indoor and outdoor temperature should agree
      within 4 units, and indoor and outdoor humidity should agree within
      10%.
  5. Inaccurate Weather Forecast:The weather forecast provided by the device is an estimate or
    generalization of weather changes in the next 12 to 24 hours, with
    an accuracy rate of about 70-75%. It should not be relied upon as
    an accurate method to predict weather.
  6. Display Console Contrast:If the display console contrast is weak, replace the batteries
    with a new set.
  7. Incorrect Weekday:To select the correct year, press and hold the RCC/SET
    button.

View Fullscreen

OUTDOOR SENSOR QUICK SET-UP GUIDE
NOTE: Prepare new and high quality alkaline batteries. Do not mix old and new batteries. Heavy duty or rechargeable batteries are not recommended.
1. POWER UP Please must follow the bellow steps to power on the device, otherwise outdoor sensor may not receive readings.
Step 1: Remove the battery door on the back of the display, insert 3 new AAA batteries in the back of the display console (please take note of the battery polarity before inserting the batteries).
Note: The display will beep once and all of the LCD segments will light up for few seconds to verify all segments are operating properly, then display indoor temperature and humidity immediately.
Step 2: Take out the metal stand inside the battery compartment and screw it into the hole at the main unit backside. Replace the battery door. Step 3: Remove the battery door of remote sensor, and set the channel of sensor to CH1, then insert 2 new AA batteries in the back of the sensor within 3 MINUTES.
Note: Make sure outside sensor and weather station main unit are at the same channel. Do not touch any buttons until the remote sensor reports in, otherwise the remote sensor searching will be terminated. When the remote sensor data has been received, all further settings can be performed. The display main unit will automatically receive remote sensor signal when sensor is powered up. The receiving status will last for max 3 minutes ( signal sensor will flash), if no signal received within 3 minutes, it will stop receiving, now you can press and hold the “CH/” Button 3 seconds to start receiving outside signal again.

2. TROUBLESHOOTING GUIDE

Problem Outdoor sensor signal is lost or showing dashes (- -) on the display

Possible Solution 1. Resync the unit. Press and hold the “CH/” button for 5-6 seconds to resynchronize. The sensor search icon will flash while searching and be solid when sensor signal is received. Please wait several minutes for the sensor to report in or the search icon to turn off. 2. If you regain connection while the sensor is mounted, great. If the the synchronization fails, bring the sensor within 10 feet of the weather station and try the bellow methods:

1) Remove the batteries of Sensor, wait 10 seconds. Then press and hold the “CH/” button for 5-6 seconds, then reinsert the batteries of sensor. (Please make sure the sensor and display console have the same channel.) 2) Factory Restart: Firstly remove all the batteries of sensor and display console. Then set the channel of Sensor to “CH1”. Reinsert the batteries of display console and press “CH/” button to choose “CH1″. Then reinsert the batteries of sensor, allow the whole set device to sit together for 30 minutes to establish a strong connection.

3. Make sure both display console and sensor are placed at least

3ft/0.9m away from electronics that may interfere with the

wireless communication, such as computers, TVs, microwaves,

other wireless transmitters or receivers, etc.

4. Make sure the sensor is not transmitting through solid metal or

thick walls. Radio Frequency (RF) Sensors cannot transmit through

metal barriers or thick walls. (Please refer REMOTE SENSOR

INSTALLATION)

Outdoor temperature ” ” cycle symbol means that weather station enter channels

and humidity always cycle mode, it will display the values of 3 channels in order every

keep cycling/how to 10 seconds.

exit the CYCLE mode

Press the “CH/” button to cancel cycle symbol.

Temperature reads too Make sure both the display console and sensor are placed out of

high in the daytime

direct sunlight and away from any heat sources or vents.

Indoor and outdoor Allow up to two hours for the sensor to stabilize due to signal

temperature

and filtering. The indoor and outdoor temperature sensor should

humidity do not agree agree within 4. And indoor and outdoor humidity sensor should

agree within 10%.

Inaccurate weather The weather forecast is an estimate or generalization of weather

forecast

changes in the next 12 to 24 hours, with an accuracy rate of about

70-75%. It is simply a tool for projecting weather conditions and is

never to be relied upon as an accurate method to predict weather.

Display console contrast Battery is low, replace a new set of batteries.

is weak

Incorrect

weekday Press and hold “RCC/SET” button to select the correct Year (year

display

range: 2000-2099).

If your BALDR weather station still can’t be worked well after trying the above

troubleshooting steps, please contact the seller on your order page or email us by

[email protected], or message us via WhatsApp: +8618664978063 for help.

]]>