<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Aeotec &#8211; UseManuals</title>
	<atom:link href="http://usemanuals.com/aeotec/feed/" rel="self" type="application/rss+xml" />
	<link>https://usemanuals.com</link>
	<description>Owner&#039;s manuals for all sorts of products</description>
	<lastBuildDate>Mon, 07 Aug 2023 09:19:13 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.7.2</generator>

<image>
	<url>https://usemanuals.com/wp-content/uploads/2025/02/favicon-32x32-2.png</url>
	<title>Aeotec &#8211; UseManuals</title>
	<link>https://usemanuals.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Aeotec Home Energy Meter C3 60A Manual</title>
		<link>https://usemanuals.com/aeotec/energy-meter-c3-60a/</link>
		
		<dc:creator><![CDATA[ItsManual]]></dc:creator>
		<pubDate>Mon, 24 Apr 2023 10:23:15 +0000</pubDate>
				<category><![CDATA[Aeotec]]></category>
		<guid isPermaLink="false">https://usemanuals.com/?p=85771</guid>

					<description><![CDATA[&#160;                                   This is a Smart Meter for Europe. To run this device please connect it to your mains power supply. To add this device to your network execute the following action: – Push the button on backside Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources. Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section. Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter. This device and every other certified Z-Wave device can be used together with any other certified ZWave device regardless of brand and origin as long as both are suited for the same frequency range. If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility. For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info. Installed in an electricity box, the energy meter will monitor the total consumption of electricity used by an entire building. And its intelligent clamps will report that energy use back to your Z-Wave gateway or controller, in watts or kilowatt-hours, and in real time. So you can see how much electricity you really use and when you use it. Red LED, Action Button, AC Input Wire, Clamps Please read the user manual before installing the product. In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network. Reset to factory default This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable. – Press and hold the button on the backside for 10 seconds Safety Warning for Mains Powered Devices ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the assembly of the product, the voltage network has to be switched off and ensured against re-switching. Unless otherwise stated, the circuit box’s main breaker should be turned off to perform these installation steps. Turn the main breaker off. Open the main circuit box panel. Clip one clamp of the meter around the incoming electricity cable that connects to the main circuit breaker. Connect the clamp to the meter using a Clamp Connector. Connect the AC Wire to the meter using the AC Wire Connector. Wire the AC Wire into one breaker. The brown wire is Live, the blue wire is neutral. Replace the main circuit box panel. Turn the main breaker back on. It is now time to place the main body of the Home Energy Meter. Inside the meter is a radio antenna used for communications, and this must be taken into consideration when selecting a location for the meter. If the circuit boxes is made of metal the radio signal strength may be reduced. In this situation it is recommended that the main body of the meter be affixed outside the circuit box. This will improve the radio signal strength. The Home Energy Meter has been weatherized to the international IP43 standard so that it is resistant to rain and snow when placed vertically with the wires protruding from the bottom of the unit. To place the Home Energy Meter: Unslot the backing plate from the back of your meter. Affix the plate to the selected wall space using the provided screws. Attach your meter to the backing plate. Diagram of EU/AU Version (3 Phases, 4 Wires): Incoming Power Lines 180V to 260V, MAX 60 A, Main Circuit Breaker, Neutral, Bus, Blue, Brown, Phase A, B, C, AC Power, HEM, Clamp Direction On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion. Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device. Inclusion – Push the button on backside Exclusion – Push the button three times on backside Setting Parameter 101 -103 Byte# Decimal Value Output Clamp# HEM Restriction byte 4 1 kWh Total Readings byte 4 2 Watt Total Readings byte 4 4 Voltage Total Readings byte 4 8 Amperage Total Readings byte 4 16 kVarh Total Readings Gen5 Only byte 4 32 kVar Total Readings Gen5 Only byte 4 64 Reserved byte 4 128 Reserved byte 3 256 Watt Clamp 1 byte 3 512 Watt Clamp 2 byte 3 1024 Watt Clamp 3 byte 3 2048 kWh Clamp 1 byte 3 4096 kWh Clamp 2 byte 3 8192 kWh Clamp 3 byte 3 16384 Reserved byte 3 32768 Reserved byte 2 65536 Voltage Clamp 1 byte 2 131072 Voltage Clamp 2 byte 2 262144 Voltage Clamp 3 byte 2 524288 Amperage Clamp 1 byte 2 1048576 Amperage Clamp 2 byte 2 2097152 Amperage Clamp 3 byte 2 4194304 Reserved byte 2 8388608 Reserved byte 1 16777216 kVah Clamp 1 Gen5 Only byte 1 33554432 kVah Clamp 2 Gen5 Only byte 1 67108864 kVah Clamp 3 Gen5 Only byte 1 134217728 kVar Clamp 1 Gen5 Only byte 1 268435456 kVar Clamp 2 Gen5 Only byte 1 536870912 kVar Clamp 3 Gen5 Only byte 1 1073741824 Reserved byte 1 2147483648 Reserved Here are a few hints for network installation if things dont work as expected. Make sure a device is in factory reset state before including. In doubt exclude before include. If inclusion still fails, check if both devices use the same frequency. Remove all dead devices from associations. Otherwise you will see severe delays. Never use sleeping battery devices without a central controller. Dont poll FLIRS devices. Make sure to have enough mains powered device to benefit from the meshing &#160; Z-Wave devices control other Z-Wave devices The relationship between one device controlling another device is called association In order to control a different always related to certain events (e.g. button pressed, sensor triggers, …). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a ‘Basic Set’ Command. Association Groups: 1 5 Send configured Value to devices 2 5 Send configured Value to devices 3 5 Send configured Value to devices Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features. IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 … 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too. Parameter 2: Energy detection mode For parameters of 101, power, energy detection mode Size: 1 Byte, Default Value: 0 0 report power, energy absolute value 1 report positive/negative power, report the algebraic sum energy 2 report positive/negative power, only report energy positive part (consuming electricity) 3 report positive/negative power, only report energy negative part (generating electricity) Parameter 3: Selective reporting Enable selective reporting only when power change reaches a certain threshold or percentage set in 4-11 below. This is used to reduce network traffic. Size: 1 Byte, Default Value: 1 0 disable 1 enable Parameter 4: Threshold change in wattage Threshold change in wattage to induce a automatic report (Whole HEM). Size: 2 Byte, Default Value: 50 0 – 60000                  Watt Parameter 5: Threshold change in wattage (Clamp 1) Threshold change in wattage to induce a automatic report Size: 2 Byte, Default Value: 50 0 – 100                       Valid value Parameter 6: Threshold change in wattage (Clamp 2) Threshold change in wattage to induce a automatic report Size: 2 Byte, Default Value: 50 0 – 100                       Valid value Parameter 7: Threshold change in wattage (Clamp 3) Threshold change in wattage to induce a automatic report Size: 2 Byte, Default Value: 50 0 – 100                       Valid value Parameter 8: Percentage change in wattage (Whole HEM) Percentage change in wattage to induce a automatic report Size: 1 Byte, Default Value: 10 &#160; Parameter 9: Percentage change in wattage (Clamp 1) Percentage change in wattage to induce a automatic report Size: 1 Byte, Default Value: 10 0 – 100                       Valid value Parameter 10: Percentage change in wattage (Clamp 2) Percentage change in wattage to induce a automatic report Size: 1 Byte, Default Value: 10 0 – 100                       Valid value Parameter 11: Percentage change in wattage (Clamp 3) Percentage change in wattage to induce a automatic report Size: 1 Byte, Default Value: 10 0 – 100                       Valid value Parameter 13: Enable /disable reporting Enable /disable reporting CRC-16 Encapsulation Command Size: 1 Byte, Default Value: 0 0 disable 1 enable Parameter 100: Reset parameter 101-103 Size: 1 Byte, Default Value: 0 1                                reset parameter 101-103 Parameter 101: Setting automatic report flags Group 1 Example: 1 + 1024 = Value 1025 If you want to report everthing, you would add the whole table together and set in to 101. Please, see table in usage. Size: 4 Byte, Default Value: 0 1                      Report Total HEM – KWH 2                      Report Total HEM – Watt 4                      Report Total HEM – Voltage 8                      Report Total HEM – Current Parameter 102: Setting automatic report flags Group 2 Example: 1 + 1024 Value 1025 If you want to report everthing you would add the whole table together and set in to 102 1                      Report Total HEM – KWH 2                      Report Total HEM – Watt 4                      Report Total HEM – Voltage 8                      Report Total HEM – Current Parameter 103: Setting automatic report flags Group 3 Example: 1 + 1024 = Value 1025 If you want to report everthing, you would add the whole table together and set in to 103. Please, see table in usage. Size: 4 Byte, Default Value: 0 1                      Report Total HEM – KWH 2                      Report Total HEM – Watt 4                      Report Total HEM – Voltage 8                      Report Total HEM – Current Parameter 110: Reset parameter 111-113 Size: 1 Byte, Default Value: 0 1                        reset parameter 111-113 Parameter 111: Setting an automatic report interval Set the report intervall for Group 1 Size: 4 Byte, Default Value: 0 1 – 2097152                 seconds Parameter 112: Setting an automatic report interval Set the report intervall for Group 1 Size: 4 Byte, Default Value: 0 1 – 2097152                 seconds Parameter 113: Setting an automatic report interval Set the report intervall for Group 1 Size: 4 Byte, Default Value: 0 1 – 2097152                 seconds Parameter 200: Partner ID Size: 1 Byte, Default Value: 0 0                     Aeon Labs Standard Product 1                     others Parameter 252: Enable/disable Configuration Locked Size: 1 Byte, Default Value: 0 0 disable 1 enable Parameter 255: Factory Reset Size: 4 Byte, Default Value: 0 1 Reset to factory default setting 1431655765 Reset to factory default setting and removed from the zwave network Dimensions : 0.1000000×0.1900000×0.0750000 mm Weight : 510 gr Hardware Platform : ZM5202 EAN : 1220000015548 IP Class : IP 44 Voltage : 400V Load : 60A Device Type : Smart Meter Firmware Version : 01.02 Z-Wave Version : 04.22 Certification ID : ZC10-16105288 Z-Wave Product Id : 0x0086.0x0002.0x005f Frequency : Europe – 868,4 Mhz Maximum transmission power : 5 mW &#160; Basic Meter Crc 16 Encap Association Grp Info Device Reset Locally Zwaveplus Info Multi Channel Configuration Manufacturer Specific Powerlevel Firmware Update Md Association Version Multi Channel Association Controller — is a Z-Wave device with capabilities to manage the network. Controllers are typically Gateways,Remote Controls or battery operated wall controllers. Slave — is a Z-Wave device without capabilities to manage the network. Slaves can be sensors, actuators and even remote controls. Primary Controller — is the central organizer of the network. It must be a controller. There can be only one primary controller in a Z-Wave network. Inclusion — is the process of adding new Z-Wave devices into a network. Exclusion — is the process of removing Z-Wave devices from the network. Association — is a control relationship between a controlling device and a controlled device. Wakeup Notification — is a special wireless message issued by a Z-Wave device to announces that is able to communicate. Node Information Frame — is a special wireless message issued by a Z-Wave device to announce its capabilities and functions. (c) 2021 Z-Wave Europe GmbH, Antonstr. 3, 09337 Hohenstein-Ernstthal, Germany, All rights reserved, www.zwave.eu. The template is maintained by . The product content is maintained by Z-Wave Europe GmbH , Supportteam, support@zwave.eu. Last update of the product data: 2017-12-27 14:26:40 [...]<p><a class="btn btn-secondary understrap-read-more-link" href="https://usemanuals.com/aeotec/energy-meter-c3-60a/">Read More...</a></p>]]></description>
										<content:encoded><![CDATA[<p>&nbsp;</p>
<h4><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/04/Aeotec-logo.jpeg" />                                 <img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/04/Aeotec-Home-Energy-Meter.webp" /></h4>
<h5></h5>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/04/Zwave-Plus.png" /></p>
<p>This is a <strong>Smart Meter</strong> for <strong>Europe</strong>. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:<br />
– Push the button on backside</p>
<p>Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.</p>
<p>Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.</p>
<p>Z-Wave ensures a reliable communication by reconfirming every message (<strong>two-way communication</strong>) and every mains powered node can act as a repeater for other nodes (<strong>meshed network</strong>) in case the receiver is not in direct wireless range of the transmitter.</p>
<p>This device and every other certified Z-Wave device can be <strong>used together with any other certified ZWave device regardless of brand and origin</strong> as long as both are suited for the same frequency range.</p>
<p>If a device supports <strong>secure communication</strong> it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.</p>
<p>For more information about Z-Wave technology, devices, white papers etc. please refer to <a href="http://www.z-wave.info" target="_blank" rel="noopener">www.z-wave.info</a>.</p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/04/ZWAVE.jpeg" /></p>
<p>Installed in an electricity box, the energy meter will monitor the total consumption of electricity used by an entire building. And its intelligent clamps will report that energy use back to your Z-Wave gateway or controller, in watts or kilowatt-hours, and in real time. So you can see how much electricity you really use and when you use it.</p>
<figure id="attachment_195909" class="wp-caption alignnone" aria-describedby="caption-attachment-195909"><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/04/Aeotec-Home-Energy-Meter-Product-Description-300x129-1.webp" /><figcaption id="caption-attachment-195909" class="wp-caption-text">Red LED, Action Button, AC Input Wire, Clamps</figcaption></figure>
<p>Please read the user manual before installing the product.</p>
<p>In order to include (add) a Z-Wave device to a network it <strong>must be in factory default state</strong>. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.</p>
<p><strong>Reset to factory default</strong><br />
This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.</p>
<p>– Press and hold the button on the backside for 10 seconds</p>
<p><strong>Safety Warning for Mains Powered Devices</strong><br />
ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the assembly of the product, the voltage network has to be switched off and ensured against re-switching.</p>
<p>Unless otherwise stated, the circuit box’s main breaker should be turned off to perform these installation steps.</p>
<ol>
<li>Turn the main breaker off.</li>
<li>Open the main circuit box panel.</li>
<li>Clip one clamp of the meter around the incoming electricity cable that connects to the main circuit breaker.</li>
<li>Connect the clamp to the meter using a Clamp Connector.</li>
<li>Connect the AC Wire to the meter using the AC Wire Connector.</li>
<li>Wire the AC Wire into one breaker. The brown wire is Live, the blue wire is neutral.</li>
<li>Replace the main circuit box panel.</li>
<li>Turn the main breaker back on.</li>
</ol>
<p>It is now time to place the main body of the Home Energy Meter. Inside the meter is a radio antenna used for communications, and this must be taken into consideration when selecting a location for the meter.</p>
<p>If the circuit boxes is made of metal the radio signal strength may be reduced. In this situation it is recommended that the main body of the meter be affixed outside the circuit box. This will improve the radio signal strength. The Home Energy Meter has been weatherized to the international IP43 standard so that it is resistant to rain and snow when placed vertically with the wires protruding from the bottom of the unit.</p>
<p>To place the Home Energy Meter:</p>
<ol>
<li>Unslot the backing plate from the back of your meter.</li>
<li>Affix the plate to the selected wall space using the provided screws.</li>
<li>Attach your meter to the backing plate.</li>
</ol>
<h4>Diagram of EU/AU Version (3 Phases, 4 Wires):</h4>
<figure id="attachment_195924" class="wp-caption alignnone" aria-describedby="caption-attachment-195924"><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/04/Aeotec-Home-Energy-Meter-Diagram-300x250-1.webp" /><figcaption id="caption-attachment-195924" class="wp-caption-text">Incoming Power Lines 180V to 260V, MAX 60 A, Main Circuit Breaker, Neutral, Bus, Blue, Brown, Phase A, B, C, AC Power, HEM, Clamp Direction</figcaption></figure>
<p>On factory default the device does not belong to any Z-Wave network. The device needs to be <strong>added to an existing wireless network</strong> to communicate with the devices of this network. This process is called <strong>Inclusion</strong>.</p>
<p>Devices can also be removed from a network. This process is called <strong>Exclusion</strong>. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.</p>
<p><strong>Inclusion</strong><br />
– Push the button on backside</p>
<p><strong>Exclusion</strong><br />
– Push the button three times on backside</p>
<p><strong>Setting Parameter 101 -103</strong></p>
<table width="830">
<tbody>
<tr>
<td width="90">Byte#</td>
<td width="160">Decimal<br />
Value</td>
<td width="125">Output</td>
<td width="125">Clamp#</td>
<td width="125">HEM<br />
Restriction</td>
</tr>
<tr>
<td width="90">byte 4</td>
<td width="160">1</td>
<td width="125">kWh</td>
<td width="125">Total<br />
Readings</td>
<td width="125"></td>
</tr>
<tr>
<td width="90">byte 4</td>
<td width="160">2</td>
<td width="125">Watt</td>
<td width="125">Total<br />
Readings</td>
<td width="125"></td>
</tr>
<tr>
<td width="90">byte 4</td>
<td width="160">4</td>
<td width="125">Voltage</td>
<td width="125">Total<br />
Readings</td>
<td width="125"></td>
</tr>
<tr>
<td width="90">byte 4</td>
<td width="160">8</td>
<td width="125">Amperage</td>
<td width="125">Total<br />
Readings</td>
<td width="125"></td>
</tr>
<tr>
<td width="90">byte 4</td>
<td width="160">16</td>
<td width="125">kVarh</td>
<td width="125">Total<br />
Readings</td>
<td width="125">Gen5<br />
Only</td>
</tr>
<tr>
<td width="90">byte 4</td>
<td width="160">32</td>
<td width="125">kVar</td>
<td width="125">Total<br />
Readings</td>
<td width="125">Gen5<br />
Only</td>
</tr>
<tr>
<td width="90">byte 4</td>
<td width="160">64</td>
<td width="125">Reserved</td>
<td width="125"></td>
<td width="125"></td>
</tr>
<tr>
<td width="90">byte 4</td>
<td width="160">128</td>
<td width="125">Reserved</td>
<td width="125"></td>
<td width="125"></td>
</tr>
<tr>
<td width="90">byte 3</td>
<td width="160">256</td>
<td width="125">Watt</td>
<td width="125">Clamp 1</td>
<td width="125"></td>
</tr>
<tr>
<td width="90">byte 3</td>
<td width="160">512</td>
<td width="125">Watt</td>
<td width="125">Clamp 2</td>
<td width="125"></td>
</tr>
<tr>
<td width="90">byte 3</td>
<td width="160">1024</td>
<td width="125">Watt</td>
<td width="125">Clamp 3</td>
<td width="125"></td>
</tr>
<tr>
<td width="90">byte 3</td>
<td width="160">2048</td>
<td width="125">kWh</td>
<td width="125">Clamp 1</td>
<td width="125"></td>
</tr>
<tr>
<td width="90">byte 3</td>
<td width="160">4096</td>
<td width="125">kWh</td>
<td width="125">Clamp 2</td>
<td width="125"></td>
</tr>
<tr>
<td width="90">byte 3</td>
<td width="160">8192</td>
<td width="125">kWh</td>
<td width="125">Clamp 3</td>
<td width="125"></td>
</tr>
<tr>
<td width="90">byte 3</td>
<td width="160">16384</td>
<td width="125">Reserved</td>
<td width="125"></td>
<td width="125"></td>
</tr>
<tr>
<td width="90">byte 3</td>
<td width="160">32768</td>
<td width="125">Reserved</td>
<td width="125"></td>
<td width="125"></td>
</tr>
<tr>
<td width="90">byte 2</td>
<td width="160">65536</td>
<td width="125">Voltage</td>
<td width="125">Clamp 1</td>
<td width="125"></td>
</tr>
<tr>
<td width="90">byte 2</td>
<td width="160">131072</td>
<td width="125">Voltage</td>
<td width="125">Clamp 2</td>
<td width="125"></td>
</tr>
<tr>
<td width="90">byte 2</td>
<td width="160">262144</td>
<td width="125">Voltage</td>
<td width="125">Clamp 3</td>
<td width="125"></td>
</tr>
<tr>
<td width="90">byte 2</td>
<td width="160">524288</td>
<td width="125">Amperage</td>
<td width="125">Clamp 1</td>
<td width="125"></td>
</tr>
<tr>
<td width="90">byte 2</td>
<td width="160">1048576</td>
<td width="125">Amperage</td>
<td width="125">Clamp 2</td>
<td width="125"></td>
</tr>
<tr>
<td width="90">byte 2</td>
<td width="160">2097152</td>
<td width="125">Amperage</td>
<td width="125">Clamp 3</td>
<td width="125"></td>
</tr>
<tr>
<td width="90">byte 2</td>
<td width="160">4194304</td>
<td width="125">Reserved</td>
<td width="125"></td>
<td width="125"></td>
</tr>
<tr>
<td width="90">byte 2</td>
<td width="160">8388608</td>
<td width="125">Reserved</td>
<td width="125"></td>
<td width="125"></td>
</tr>
<tr>
<td width="90">byte 1</td>
<td width="160">16777216</td>
<td width="125">kVah</td>
<td width="125">Clamp 1</td>
<td width="125">Gen5<br />
Only</td>
</tr>
<tr>
<td width="90">byte 1</td>
<td width="160">33554432</td>
<td width="125">kVah</td>
<td width="125">Clamp 2</td>
<td width="125">Gen5<br />
Only</td>
</tr>
<tr>
<td width="90">byte 1</td>
<td width="160">67108864</td>
<td width="125">kVah</td>
<td width="125">Clamp 3</td>
<td width="125">Gen5<br />
Only</td>
</tr>
<tr>
<td width="90">byte 1</td>
<td width="160">134217728</td>
<td width="125">kVar</td>
<td width="125">Clamp 1</td>
<td width="125">Gen5<br />
Only</td>
</tr>
<tr>
<td width="90">byte 1</td>
<td width="160">268435456</td>
<td width="125">kVar</td>
<td width="125">Clamp 2</td>
<td width="125">Gen5<br />
Only</td>
</tr>
<tr>
<td width="90">byte 1</td>
<td width="160">536870912</td>
<td width="125">kVar</td>
<td width="125">Clamp 3</td>
<td width="125">Gen5<br />
Only</td>
</tr>
<tr>
<td width="90">byte 1</td>
<td width="160">1073741824</td>
<td width="125">Reserved</td>
<td width="125"></td>
<td width="125"></td>
</tr>
<tr>
<td width="90">byte 1</td>
<td width="160">2147483648</td>
<td width="125">Reserved</td>
<td width="125"></td>
<td width="125"></td>
</tr>
</tbody>
</table>
<p>Here are a few hints for network installation if things dont work as expected.</p>
<ol>
<li>Make sure a device is in factory reset state before including. In doubt exclude before include.</li>
<li>If inclusion still fails, check if both devices use the same frequency.</li>
<li>Remove all dead devices from associations. Otherwise you will see severe delays.</li>
<li>Never use sleeping battery devices without a central controller.</li>
<li>Dont poll FLIRS devices.</li>
<li>Make sure to have enough mains powered device to benefit from the meshing</li>
</ol>
<p>&nbsp;</p>
<p>Z-Wave devices control other Z-Wave devices The relationship between one device controlling another device is called association In order to control a different always related to certain events (e.g. button pressed, sensor triggers, …). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a ‘Basic Set’ Command.</p>
<h5>Association Groups:</h5>
<table width="824">
<tbody>
<tr>
<td width="129"></td>
<td width="111"></td>
<td width="384"></td>
</tr>
<tr>
<td width="129">1</td>
<td width="111">5</td>
<td width="384">Send configured Value to devices</td>
</tr>
<tr>
<td width="129">2</td>
<td width="111">5</td>
<td width="384">Send configured Value to devices</td>
</tr>
<tr>
<td width="129">3</td>
<td width="111">5</td>
<td width="384">Send configured Value to devices</td>
</tr>
</tbody>
</table>
<p>Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.</p>
<p><strong>IMPORTANT:</strong> Controllers may only allow configuring signed values. In order to set values in the range 128 … 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.</p>
<p><strong>Parameter 2: Energy detection mode</strong><br />
For parameters of 101, power, energy detection mode<br />
Size: 1 Byte, Default Value: 0</p>
<table width="827">
<tbody>
<tr>
<td width="108"></td>
<td width="516"></td>
</tr>
<tr>
<td width="108">0</td>
<td width="516">report power, energy absolute value</td>
</tr>
<tr>
<td width="108">1</td>
<td width="516">report positive/negative power, report the algebraic sum energy</td>
</tr>
<tr>
<td width="108">2</td>
<td width="516">report positive/negative power, only report energy<br />
positive part (consuming electricity)</td>
</tr>
<tr>
<td width="108">3</td>
<td width="516">report positive/negative power, only report energy<br />
negative part (generating electricity)</td>
</tr>
</tbody>
</table>
<p><strong>Parameter 3: Selective reporting</strong><br />
Enable selective reporting only when power change reaches a certain threshold or percentage set in 4-11 below. This is used to reduce network traffic. Size: 1 Byte, Default Value: 1</p>
<table width="824">
<tbody>
<tr>
<td width="114"></td>
<td width="510"></td>
</tr>
<tr>
<td width="114">0</td>
<td width="510">disable</td>
</tr>
<tr>
<td width="114">1</td>
<td width="510">enable</td>
</tr>
</tbody>
</table>
<p><strong>Parameter 4: Threshold change in wattage</strong><br />
Threshold change in wattage to induce a automatic report (Whole HEM).<br />
Size: 2 Byte, Default Value: 50</p>
<p><strong>0 – 60000</strong>                  Watt</p>
<p><strong>Parameter 5: Threshold change in wattage (Clamp 1)</strong><br />
Threshold change in wattage to induce a automatic report<br />
Size: 2 Byte, Default Value: 50</p>
<p><strong>0 – 100</strong>                       Valid value</p>
<p><strong>Parameter 6: Threshold change in wattage (Clamp 2)</strong><br />
Threshold change in wattage to induce a automatic report<br />
Size: 2 Byte, Default Value: 50</p>
<p><strong>0 – 100</strong>                       Valid value</p>
<p><strong>Parameter 7: Threshold change in wattage (Clamp 3)</strong><br />
Threshold change in wattage to induce a automatic report<br />
Size: 2 Byte, Default Value: 50</p>
<p><strong>0 – 100</strong>                       Valid value</p>
<p><strong>Parameter 8: Percentage change in wattage (Whole HEM)</strong><br />
Percentage change in wattage to induce a automatic report<br />
Size: 1 Byte, Default Value: 10</p>
<p>&nbsp;</p>
<p><strong>Parameter 9: Percentage change in wattage (Clamp 1)</strong><br />
Percentage change in wattage to induce a automatic report<br />
Size: 1 Byte, Default Value: 10</p>
<p><strong>0 – 100</strong>                       Valid value</p>
<p><strong>Parameter 10: Percentage change in wattage (Clamp 2)</strong><br />
Percentage change in wattage to induce a automatic report<br />
Size: 1 Byte, Default Value: 10</p>
<p><strong>0 – 100</strong>                       Valid value</p>
<p><strong>Parameter 11: Percentage change in wattage (Clamp 3)</strong><br />
Percentage change in wattage to induce a automatic report<br />
Size: 1 Byte, Default Value: 10</p>
<p><strong>0 – 100</strong>                       Valid value</p>
<p><strong>Parameter 13: Enable /disable reporting</strong><br />
Enable /disable reporting CRC-16 Encapsulation Command<br />
Size: 1 Byte, Default Value: 0</p>
<table width="826">
<tbody>
<tr>
<td width="114"></td>
<td width="510"></td>
</tr>
<tr>
<td width="114">0</td>
<td width="510">disable</td>
</tr>
<tr>
<td width="114">1</td>
<td width="510">enable</td>
</tr>
</tbody>
</table>
<p><strong>Parameter 100: Reset parameter 101-103</strong><br />
Size: 1 Byte, Default Value: 0</p>
<p><b>1</b>                                reset parameter 101-103</p>
<p><strong>Parameter 101: Setting automatic report flags Group 1</strong><br />
Example: 1 + 1024 = Value 1025 If you want to report everthing, you would add the whole table together and set in to 101.<br />
Please, see table in usage.<br />
Size: 4 Byte, Default Value: 0</p>
<p><strong>1</strong>                      Report Total HEM – KWH<br />
<strong>2</strong>                      Report Total HEM – Watt<br />
<strong>4</strong>                      Report Total HEM – Voltage<br />
<strong>8</strong>                      Report Total HEM – Current</p>
<p><strong>Parameter 102: Setting automatic report flags Group 2</strong><br />
Example: 1 + 1024 Value 1025 If you want to report everthing you would add the whole table together and set in to 102</p>
<p><strong>1</strong>                      Report Total HEM – KWH<br />
<strong>2</strong>                      Report Total HEM – Watt<br />
<strong>4</strong>                      Report Total HEM – Voltage<br />
<strong>8</strong>                      Report Total HEM – Current</p>
<p><strong>Parameter 103: Setting automatic report flags Group 3</strong><br />
Example: 1 + 1024 = Value 1025 If you want to report everthing, you would add the whole table together and set in to 103.<br />
Please, see table in usage.<br />
Size: 4 Byte, Default Value: 0</p>
<p><strong>1</strong>                      Report Total HEM – KWH<br />
<strong>2</strong>                      Report Total HEM – Watt<br />
<strong>4</strong>                      Report Total HEM – Voltage<br />
<strong>8</strong>                      Report Total HEM – Current</p>
<p><strong>Parameter 110: Reset parameter 111-113</strong></p>
<p>Size: 1 Byte, Default Value: 0</p>
<p><strong>1</strong>                        reset parameter 111-113</p>
<p><strong>Parameter 111: Setting an automatic report interval</strong><br />
Set the report intervall for Group 1<br />
Size: 4 Byte, Default Value: 0</p>
<p>1 – 2097152                 seconds</p>
<p><strong>Parameter 112: Setting an automatic report interval</strong><br />
Set the report intervall for Group 1<br />
Size: 4 Byte, Default Value: 0</p>
<p>1 – 2097152                 seconds</p>
<p><strong>Parameter 113: Setting an automatic report interval</strong><br />
Set the report intervall for Group 1<br />
Size: 4 Byte, Default Value: 0</p>
<p>1 – 2097152                 seconds</p>
<p><strong>Parameter 200: Partner ID</strong></p>
<p>Size: 1 Byte, Default Value: 0</p>
<p><strong>0</strong>                     Aeon Labs Standard Product<br />
<strong>1</strong>                     others</p>
<p><strong>Parameter 252: Enable/disable Configuration Locked</strong></p>
<p>Size: 1 Byte, Default Value: 0</p>
<table width="828">
<tbody>
<tr>
<td width="114"></td>
<td width="510"></td>
</tr>
<tr>
<td width="114">0</td>
<td width="510">disable</td>
</tr>
<tr>
<td width="114">1</td>
<td width="510">enable</td>
</tr>
</tbody>
</table>
<p><strong>Parameter 255: Factory Reset</strong><br />
Size: 4 Byte, Default Value: 0</p>
<table width="826">
<tbody>
<tr>
<td width="114"></td>
<td width="510"></td>
</tr>
<tr>
<td width="114"><strong>1</strong></td>
<td width="510">Reset to factory default setting</td>
</tr>
<tr>
<td width="114"><strong>1431655765</strong></td>
<td width="510">Reset to factory default setting and removed from the zwave network</td>
</tr>
</tbody>
</table>
<p><strong>Dimensions :</strong> 0.1000000×0.1900000×0.0750000 mm<br />
<strong>Weight :</strong> 510 gr<br />
<strong>Hardware Platform :</strong> ZM5202<br />
<strong>EAN :</strong> 1220000015548<br />
<strong>IP Class :</strong> IP 44<br />
<strong>Voltage :</strong> 400V<br />
<strong>Load :</strong> 60A<br />
<strong>Device Type :</strong> Smart Meter<br />
<strong>Firmware Version :</strong> 01.02<br />
<strong>Z-Wave Version :</strong> 04.22<br />
<strong>Certification ID :</strong> ZC10-16105288<br />
<strong>Z-Wave Product Id :</strong> 0x0086.0x0002.0x005f<br />
<strong>Frequency :</strong> Europe – 868,4 Mhz<br />
<strong>Maximum transmission power :</strong> 5 mW</p>
<p>&nbsp;</p>
<ul>
<li>Basic</li>
<li>Meter</li>
<li>Crc 16 Encap</li>
<li>Association Grp Info</li>
<li>Device Reset Locally</li>
<li>Zwaveplus Info</li>
<li>Multi Channel</li>
<li>Configuration</li>
<li>Manufacturer Specific</li>
<li>Powerlevel</li>
<li>Firmware Update Md</li>
<li>Association</li>
<li>Version</li>
<li>Multi Channel Association</li>
<li><strong>Controller —</strong> is a Z-Wave device with capabilities to manage the network. Controllers are typically Gateways,Remote Controls or battery operated wall controllers.</li>
<li><strong>Slave —</strong> is a Z-Wave device without capabilities to manage the network. Slaves can be sensors, actuators and even remote controls.</li>
<li><strong>Primary Controller —</strong> is the central organizer of the network. It must be a controller. There can be only one primary controller in a Z-Wave network.</li>
<li><strong>Inclusion —</strong> is the process of adding new Z-Wave devices into a network.</li>
<li><strong>Exclusion —</strong> is the process of removing Z-Wave devices from the network.</li>
<li><strong>Association —</strong> is a control relationship between a controlling device and a controlled device.</li>
<li><strong>Wakeup Notification —</strong> is a special wireless message issued by a Z-Wave device to announces that is able to communicate.</li>
<li><strong>Node Information Frame —</strong> is a special wireless message issued by a Z-Wave device to announce its capabilities and functions.</li>
</ul>
<hr />
<p>(c) 2021 Z-Wave Europe GmbH, Antonstr. 3, 09337 Hohenstein-Ernstthal, Germany, All rights reserved, <a href="https://www.zwave.eu/index.php?id=13&amp;L=0" target="_blank" rel="noopener">www.zwave.eu</a>. The template is maintained by . The product content is maintained by Z-Wave Europe GmbH , Supportteam, <a href="mailto:support@zwave.eu">support@zwave.eu</a>. Last update of the product data: 2017-12-27</p>
<p>14:26:40</p>
<form id="commentform" class="comment-form" action="https://manuals.plus/wp-comments-post.php" method="post" novalidate="">
<p class="form-submit"><input id="comment_post_ID" name="comment_post_ID" type="hidden" value="190975" /><br />
<input id="comment_parent" name="comment_parent" type="hidden" value="0" /></p>
</form>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Aeotec Motion Sensor Manual</title>
		<link>https://usemanuals.com/aeotec/motion-sensor/</link>
		
		<dc:creator><![CDATA[ItsManual]]></dc:creator>
		<pubDate>Mon, 07 Aug 2023 09:19:13 +0000</pubDate>
				<category><![CDATA[Aeotec]]></category>
		<guid isPermaLink="false">https://usemanuals.com/?p=189125</guid>

					<description><![CDATA[Aeotec Motion Sensor user guide Modified on: Tue, 24 Nov 2020 at 2:41 AM Aeotec Motion Sensor was developed to detect motion and temperature while it is connected to Aeotec Smart Home Hub. It is powered by Aeotec Zigbee technology. Aeotec Motion Sensor must be used with a compatible ZigBee Hub, like Aeotec Smart Home Hub, in order to work. Familiarize yourself with Aeotec Motion Sensor Package contents: Aeotec Motion Sensor User manual Health and safety guide Magnetic ball mount 3M adhesive strips 1x CR2 battery Important safety information Read, keep, and follow these instructions. Heed all warnings. Clean only with a dry cloth. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. Only use attachments and accessories specified by the Manufacturer. Connect the Aeotec Motion Sensor Video link: https://youtu.be/hLb-uI0BTFE Steps in SmartThings Connect From the Home screen, tap the Plus (+) icon and select Device. Select Aeotec and then Motion Sensor (IM6001-MTP). Tap Start Choose a Hub for the device. 5. Choose a Room for the device and tap Next. While the Hub searches: •Pull the “Remove when Connecting” tab found in the sensor. •Scan the code on the back of the device. Using Aeotec Motion Sensor Aeotec Motion Sensor is now a part of your Aeotec Smart Home Hub network. It will appear as a motion widget that can display motion status or temperature sensor readings. This section will go over how to display all information in your SmartThings Connect app. Steps in SmartThings Connect Open SmartThings Connect Scroll down to your Aeotec Motion Sensor Then tap the Aeotec Motion Sensor widget. On this screen, it should display: • Motion • Temperature You may use a Motion and Temperature sensor in an Automation to control your Aeotec Smart Home Hub home automation network. How to remove Aeotec Motion Sensor from Aeotec Smart Home Hub. If your Aeotec Motion Sensor is not performing as you expected, you’ll likely need to reset your motion sensor and remove it from Aeotec Smart Home Hub to begin a fresh start. Steps From the Home screen, select Menu Select More Options (3 dot icon) Tap Edit Tap Delete to confirm Factory reset your Aeotec Motion Sensor Aeotec Motion Sensor can be factory reset at any time if you come across any issues, or if you need to re-pair Aeotec Motion Sensor to another hub. Video link: https://youtu.be/4useLYFLJiw Steps in SmartThings Connect. Press and Hold the recessed connect button for five (5) seconds. Release the button when the LED starts blinking red. The LED will blink red and green while attempting to connect. Use the SmartThings app and steps detailed in “Connect the Aeotec Motion Sensor” above. This page lists Aeotec product technical specifications for Aeotec Motion Sensor. Name: Aeotec Motion Sensor Model number: EU: GP-AEOMSSEU US: GP-AEOMSSUS AU: GP-AEOMSSAU Hardware required: Aeotec Smart Home Hub Software required: SmartThings Connect (iOS or Android) Radio protocol: Zigbee3 Power supply: No Battery charger input: No Battery Type: 1 * CR2 Radiofrequency: 2.4 GHz Sensor: Motion Temperature Indoor/Outdoor use: Indoor only Operating distance: 50 – 100 ft 15.2 – 40 m Dimension of Button: 2.19 x 1.98 x 2.19 in 56.6 x 50.2 x 55.7 mm Weight: 95 g 3.36 oz [...]<p><a class="btn btn-secondary understrap-read-more-link" href="https://usemanuals.com/aeotec/motion-sensor/">Read More...</a></p>]]></description>
										<content:encoded><![CDATA[<p><strong>Aeotec Motion Sensor user guide</strong><br />
<strong>Modified on: Tue, 24 Nov 2020 at 2:41 AM</strong></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/08/Aeotec-Motion-Sensor.webp" /></p>
<p>Aeotec Motion Sensor was developed to detect motion and temperature while it is connected to Aeotec Smart Home Hub. It is powered by Aeotec Zigbee technology.<br />
Aeotec Motion Sensor must be used with a compatible ZigBee Hub, like Aeotec Smart Home Hub, in order to work.</p>
<h4>Familiarize yourself with Aeotec Motion Sensor</h4>
<p><strong>Package contents:</strong></p>
<ol>
<li>Aeotec Motion Sensor</li>
<li>User manual</li>
<li>Health and safety guide</li>
<li>Magnetic ball mount</li>
<li>3M adhesive strips</li>
<li>1x CR2 battery</li>
</ol>
<p><strong>Important safety information</strong></p>
<ul>
<li>Read, keep, and follow these instructions. Heed all warnings.</li>
<li>Clean only with a dry cloth.</li>
<li>Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.</li>
<li>Only use attachments and accessories specified by the Manufacturer.</li>
</ul>
<h4>Connect the Aeotec Motion Sensor</h4>
<p>Video link: <a href="https://youtu.be/hLb-uI0BTFE" target="_blank" rel="noopener">https://youtu.be/hLb-uI0BTFE</a><br />
<strong>Steps in SmartThings Connect</strong></p>
<ol>
<li>From the Home screen, tap the Plus (+) icon and select Device.</li>
<li>Select Aeotec and then Motion Sensor (IM6001-MTP).</li>
<li>Tap Start</li>
<li>Choose a Hub for the device. 5. Choose a Room for the device and tap Next.</li>
<li>While the Hub searches:<br />
•Pull the “Remove when Connecting” tab found in the sensor.<br />
•Scan the code on the back of the device.</li>
</ol>
<h4>Using Aeotec Motion Sensor</h4>
<p>Aeotec Motion Sensor is now a part of your Aeotec Smart Home Hub network. It will appear as a motion widget that can display motion status or temperature sensor readings.<br />
This section will go over how to display all information in your SmartThings Connect app.<br />
<strong>Steps in SmartThings Connect</strong></p>
<ol>
<li>Open SmartThings Connect</li>
<li>Scroll down to your Aeotec Motion Sensor</li>
<li>Then tap the Aeotec Motion Sensor widget.</li>
<li>On this screen, it should display:<br />
• Motion<br />
• Temperature</li>
</ol>
<p>You may use a Motion and Temperature sensor in an Automation to control your Aeotec Smart Home Hub home automation network.</p>
<h4>How to remove Aeotec Motion Sensor from Aeotec Smart Home Hub.</h4>
<p>If your Aeotec Motion Sensor is not performing as you expected, you’ll likely need to reset your motion sensor and remove it from Aeotec Smart Home Hub to begin a fresh start.</p>
<p><strong>Steps</strong></p>
<ol>
<li>From the Home screen, select Menu</li>
<li>Select More Options (3 dot icon)</li>
<li>Tap Edit</li>
<li>Tap Delete to confirm</li>
</ol>
<h4>Factory reset your Aeotec Motion Sensor</h4>
<p>Aeotec Motion Sensor can be factory reset at any time if you come across any issues, or if you need to re-pair Aeotec Motion Sensor to another hub.<br />
Video link: <a href="https://youtu.be/4useLYFLJiw" target="_blank" rel="noopener">https://youtu.be/4useLYFLJiw</a><br />
<strong>Steps in SmartThings Connect.</strong></p>
<ol>
<li><strong>Press and Hold the recessed connect button</strong> for five (5) seconds.</li>
<li><strong>Release the button</strong> when the LED starts blinking red.</li>
<li>The LED will blink red and green while attempting to connect.</li>
<li>Use the SmartThings app and steps detailed in “Connect the Aeotec Motion Sensor” above.</li>
</ol>
<p>This page lists Aeotec product technical specifications for Aeotec Motion Sensor.<br />
<strong>Name</strong>: Aeotec Motion Sensor<br />
<strong>Model number</strong>:<br />
<strong>EU:</strong> GP-AEOMSSEU<br />
<strong>US:</strong> GP-AEOMSSUS<br />
<strong>AU:</strong> GP-AEOMSSAU<br />
<strong>Hardware required:</strong> Aeotec Smart Home Hub<br />
<strong>Software required:</strong> SmartThings Connect (iOS or Android)<br />
<strong>Radio protocol:</strong> Zigbee3<br />
<strong>Power supply:</strong> No<br />
<strong>Battery charger input:</strong> No<br />
<strong>Battery Type:</strong> 1 * CR2<br />
<strong>Radiofrequency:</strong> 2.4 GHz<br />
<strong>Sensor:</strong><br />
Motion<br />
Temperature<br />
<strong>Indoor/Outdoor use:</strong> Indoor only</p>
<p><strong>Operating distance:</strong><br />
50 – 100 ft<br />
15.2 – 40 m<br />
<strong>Dimension of Button:</strong><br />
2.19 x 1.98 x 2.19 in<br />
56.6 x 50.2 x 55.7 mm<br />
<strong>Weight:</strong><br />
95 g<br />
3.36 oz</p>
<form id="commentform" class="comment-form" action="https://manuals.plus/wp-comments-post.php" method="post" novalidate="">
<p class="form-submit">
</form>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>

<!--
Performance optimized by W3 Total Cache. Learn more: https://www.boldgrid.com/w3-total-cache/

Page Caching using Disk: Enhanced 

Served from: usemanuals.com @ 2026-08-30 17:35:07 by W3 Total Cache
-->