<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>ACC-CHEK &#8211; UseManuals</title>
	<atom:link href="http://usemanuals.com/acc-chek/feed/" rel="self" type="application/rss+xml" />
	<link>https://usemanuals.com</link>
	<description>Owner&#039;s manuals for all sorts of products</description>
	<lastBuildDate>Sat, 24 Jun 2023 19:58:18 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.7.2</generator>

<image>
	<url>https://usemanuals.com/wp-content/uploads/2025/02/favicon-32x32-2.png</url>
	<title>ACC-CHEK &#8211; UseManuals</title>
	<link>https://usemanuals.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>ACC-CHEK Performa Blood Glucose Meter Manual</title>
		<link>https://usemanuals.com/acc-chek/performa-meter/</link>
		
		<dc:creator><![CDATA[ItsManual]]></dc:creator>
		<pubDate>Sat, 24 Jun 2023 19:58:18 +0000</pubDate>
				<category><![CDATA[ACC-CHEK]]></category>
		<guid isPermaLink="false">https://usemanuals.com/?p=122192</guid>

					<description><![CDATA[ACC-CHEK Performa Blood Glucose Meter User Guide WARNING This Quick Start Guide does not replace the User’s Manual for your Accu-Chek Performa blood glucose meter. The User’s Manual contains important handling instructions and additional information. WARNING The Accu-Chek FastClix lancing device is intended for patient self-monitoring by an individual person only. It must not be used to collect blood from more than one person as it does not incorporate any features to guard against cross-infection. Meter Overview Setting up the Lancing Device Familiarise yourself with the Accu-Chek FastClix lancing device. Get the lancet drum from the pocket in the carry case. NOTE Each lancet drum contains 6 sterile lancets. Remove the cap by pulling it straight off. Do not twist the cap. WARNING You must not insert the lancet drum into the lancing device and simultaneously press the release button or hold the lancing device with the release button resting on a surface such as a table top. This could release a lancet and inadvertently cause injury Insert the lancet drum, white end first, into the lancing device. Push the lancet drum all the way in until it clicks firmly into place. NOTE Do not remove the lancet drum until all 6 lancets have been used since the lancet drum cannot be reused once it has been removed from the lancing device. Replace the cap on the lancing device. Make sure the notch on the cap lines up with the notch on the lancing device. Adjust the lancet depth to a comfortable penetration level. Start at 2 or 3. For tougher skin, dial to a higher number. Using the Accu-Chek FastClix lancing device: By pressing the release button, the lancing device primes and pricks in 1-Click action. Setting the Time and Date on the Meter You will need to do this the first time you use the meter. Press and release (power/set button) to turn the meter on. The flashing test strip symbol appears on the display Use or to adjust the hour. Press and release to advance through the hour, minutes, day, month and year, adjusting each flashing setting as needed with or . Performing a Blood Glucose Test Wash and dry your hands. Prepare the lancing device. Check the use by date on the test strip container. Do not use test strips past the use by date. Insert the test strip into the meter in the direction of the arrows. The meter turns on and beeps. When the blood drop symbol flashes, perform a fingerstick with the lancing device Gently squeeze your finger to assist the blood flow. This helps you get a blood drop. Touch the blood drop to the front edge of the yellow window of the test strip. Do not put blood on top of the test strip. The meter beeps and flashes when there is enough blood in the test strip. The test result appears on the display. To assign a marker to the test result, leave the test strip in the meter. Remove and discard the used test strip. After a successful test, the meter turns itself off 5 seconds after the test strip is removed If you need any more help or information please contact your Roche representative. © 2019 Roche Diabetes Care Limited. All rights reserved. ACCU-CHEK, ACCU-CHEK PERFORMA and FASTCLIX are trademarks of Roche. All other trademarks are the property of their respective owners. Date of Preparation: December 2019. For healthcare professional use only in the UK and Ireland. Roche Diabetes Care Limited, Charles Avenue, Burgess Hill, RH15 9RY, UK. Company registration number: 9055599 www.accu-chek.co.uk [...]<p><a class="btn btn-secondary understrap-read-more-link" href="https://usemanuals.com/acc-chek/performa-meter/">Read More...</a></p>]]></description>
										<content:encoded><![CDATA[<p><strong>ACC-CHEK Performa Blood Glucose Meter User Guide</p>
<p></strong></p>
<p><strong><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/06/Screenshot_2-593-1.webp" /> WARNING</strong><br />
This Quick Start Guide does not replace the User’s Manual for your Accu-Chek Performa blood glucose meter. The User’s Manual contains important handling instructions and additional information.</p>
<p><strong><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/06/Screenshot_2-593-1.webp" /> WARNING</strong><br />
The Accu-Chek FastClix lancing device is intended for patient self-monitoring by an individual person only. It must not be used to collect blood from more than one person as it does not incorporate any features to guard against cross-infection.</p>
<h4>Meter Overview</h4>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/06/Screenshot_3-571-550x307-1.webp" /><br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/06/232.webp" /><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/06/Screenshot_5-502.webp" /></p>
<h4>Setting up the Lancing Device</h4>
<ul>
<li>Familiarise yourself with the Accu-Chek FastClix lancing device.<br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/06/Screenshot_6-461.webp" /></li>
<li>Get the lancet drum from the pocket in the carry case.<br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/06/Screenshot_7-411-550x273-1.webp" /><br />
<strong>NOTE</strong><br />
Each lancet drum contains 6 sterile lancets.</li>
<li>Remove the cap by pulling it straight off.<br />
Do not twist the cap.<br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/06/Screenshot_8-394.webp" /><br />
<strong><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/06/Screenshot_2-593-1.webp" /> WARNING</strong><br />
You must not insert the lancet drum into the lancing device and simultaneously press the release button or hold the lancing device with the release button resting on a surface such as a table top.<br />
This could release a lancet and inadvertently cause injury</li>
<li>Insert the lancet drum, white end first, into the lancing device. Push the lancet drum all the way in until it clicks firmly into place.<br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/06/Screenshot_9-287-550x276-1.webp" /><br />
<strong>NOTE</strong><br />
Do not remove the lancet drum until all 6 lancets have been used since the lancet drum cannot be reused once it has been removed from the lancing device.</li>
<li>Replace the cap on the lancing device.<br />
Make sure the notch on the cap lines up with the notch on the lancing device.<br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/06/Screenshot_10-338.webp" /></li>
<li>Adjust the lancet depth to a comfortable penetration level. Start at 2 or 3. For tougher skin, dial to a higher number.<br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/06/Screenshot_11-315.webp" /></li>
<li>Using the Accu-Chek FastClix lancing device:<br />
By pressing the release button, the lancing device primes and pricks in 1-Click action.<br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/06/Screenshot_12-303.webp" /></li>
</ul>
<h4>Setting the Time and Date on the Meter</h4>
<p>You will need to do this the first time you use the meter.<br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/06/Screenshot_18-189-550x487-1.webp" /></p>
<ol>
<li>Press and release <img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/06/Screenshot_15-228.webp" /> (power/set button) to turn the meter on. The flashing test strip symbol appears on the display<br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/06/Screenshot_13-270.webp" /></li>
<li>Use <img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/06/Screenshot_16-220.webp" /> or <img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/06/Screenshot_17-199.webp" /> to adjust the hour. Press and release <img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/06/Screenshot_15-228.webp" /> to advance through the hour, minutes, day, month and year, adjusting each flashing setting as needed with <img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/06/Screenshot_16-220.webp" /> or <img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/06/Screenshot_17-199.webp" />.<br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/06/Screenshot_14-253.webp" /></li>
</ol>
<h4>Performing a Blood Glucose Test</h4>
<ol>
<li>Wash and dry your hands.<br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/06/Screenshot_19-165.webp" /></li>
<li>Prepare the lancing device.<br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/06/Screenshot_20-152.webp" /></li>
<li>Check the use by date on the test strip container. Do not use test strips past the use by date.<br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/06/Screenshot_21-145.webp" /></li>
<li>Insert the test strip into the meter in the direction of the arrows.<br />
The meter turns on and beeps.<br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/06/Screenshot_22-139.webp" /></li>
<li>When the blood drop symbol flashes, perform a fingerstick with the lancing device<br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/06/Screenshot_23-120.webp" /></li>
<li>Gently squeeze your finger to assist the blood flow. This helps you get a blood drop.<br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/06/Screenshot_24-116.webp" /></li>
<li>Touch the blood drop to the front edge of the yellow window of the test strip.<br />
Do not put blood on top of the test strip.<br />
The meter beeps and flashes when there is enough blood in the test strip.<br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/06/Screenshot_25-109.webp" /></li>
<li>The test result appears on the display. To assign a marker to the test result, leave the test strip in the meter. Remove and discard the used test strip. After a successful test, the meter turns itself off 5 seconds after the test strip is removed<br />
<img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/06/Screenshot_26-104-550x274-1.webp" /></li>
</ol>
<p>If you need any more help or information please contact your Roche representative.</p>
<p>© 2019 Roche Diabetes Care Limited. All rights reserved.</p>
<p>ACCU-CHEK, ACCU-CHEK PERFORMA and FASTCLIX are trademarks of Roche.</p>
<p>All other trademarks are the property of their respective owners.</p>
<p>Date of Preparation: December 2019. For healthcare professional use only in the UK and Ireland.</p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/06/Screenshot_27-95.webp" /><br />
Roche Diabetes Care Limited, Charles Avenue, Burgess Hill, RH15 9RY, UK.<br />
Company registration number: 9055599 <a href="http://www.accu-chek.co.uk/" target="_blank" rel="noopener">www.accu-chek.co.uk</a></p>
<p><img decoding="async" src="https://usemanuals.com/wp-content/uploads/2023/06/Screenshot_1-612-550x54-1.webp" /></p>
<form id="commentform" class="comment-form" action="https://manuals.plus/wp-comments-post.php" method="post" novalidate="">
<p class="form-submit">
</form>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>

<!--
Performance optimized by W3 Total Cache. Learn more: https://www.boldgrid.com/w3-total-cache/

Page Caching using Disk: Enhanced 

Served from: usemanuals.com @ 2026-04-24 23:30:24 by W3 Total Cache
-->